Omron-Electronics-G6WK-1P-DC12

Part #Omron-Electronics-G6WK-1P-DC12
Download 
Omron-Electronics-G6WK-1P-DC12
DISCONTINUED  
High-frequency Relay  
G6W  
Surface-mountable 5 GHz Band Miniature  
SPDT High-frequency Relay  
• Superior high-frequency characteristics, such as an  
isolation of 35 dB min., insertion loss of 0.5 dB max., and  
V
.
S.W.R. of 1.7 max. at 5 GHz (50
Ω
).  
• High-frequency characteristics obtained by adopting  
tri-plate micro strip line design.  
• Small size at 20 x 9.4 x 8.9 mm (L x W x H).  
•
Y
–
shape terminal structure and reverse contact option  
simplifies wiring to PCBs.  
• RoHS Compliant.  
Ordering Information  
Classification  
Non latching  
Single-coil  
latching  
Dual-coil  
latching  
SPDT  
Fully sealed
 
Through-hole terminal  
Surface-mount terminal  
Y
–
shape terminal  
Y
–
shape terminal  
G6W-1P  
G6W-1F  
G6WU-1P  
G6WK-1P  
G6WK-1F  
G6WU-1F  
Note:
W
hen ordering, add the rated coil
v
oltage to the model n
u
m
b
er.  
Example: G6
W
-1P DC12  
Rated coil
v
oltage  
Model Number Le
g
end:  
G6W  
–
–
1
2
3
4
5
1. Relay
 
function  
N
one:
N
on-latching  
3. Terminal
 
shape  
5. Contact
 
Arran
g
ement  
F:  
P:  
S
u
rface-mo
u
nt terminals  
PCB thro
u
gh-hole terminals  
N
one: Standard
 
contact arrangement  
U:  
K:  
Single-coil latching  
R:  
Re
v
erse contact arrangement  
(A
v
aila
b
le only for
N
on-Latching  
v
ersions)  
D
u
al-coil latching  
4. Terminal
 
Structure  
2. Contact
 
form  
1: SPDT  
N
one: Y-shape
 
terminal  
(standard)  
■
Typical Applications  
•
Mobile phone base station (W-CDMA, UMTS, CDMA-2000, PCS)  
•
Wireless LAN and TV transmitters  
•
T
e
st and Measurement devices  
•
Signal Generators  
High-frequency Relay
 
G6W  
327  

DISCONTINUED  
Specifications  
■
Contact Ratings  
Load type  
Resistive load  
Contact material  
Rated load  
Au clad Cu alloy  
10 mA at 30 VAC; 10 mA at 30 VDC  
2.5 GHz, 50
Ω,
10 W (See note 2)  
0.5 A  
Rated carry current  
Max. switching voltage  
Max. switching current  
30 VDC, 30 VAC  
0.5 A  
■
High-frequency Characteristics  
Frequency  
2.0 GHz  
65 dB min.  
0.2 dB max.  
2.5 GHz  
60 dB min.  
5.0 GHz  
Isolation  
35 dB min.  
Insertion loss  
V
.
S.W.R.  
0.5 dB max.  
1.7 max.  
1.2 max.  
Max. carry power  
Max. switching power  
20 W (See note 2)  
10 W (See note 2)  
Note: 1.
 
The above values are initial values.  
2.
These values are for a load with
V
.
S.W.R.
≤
1.2 at an impedance of 50
Ω
.  
■
Coil Ratings  
Non-latching Relays (G6W-1F, G6W-1P)  
Rated voltage  
3 VDC  
66.7 mA  
45
Ω  
4.5 VDC  
44.4 mA  
101
Ω  
9 VDC  
22.2 mA  
405
Ω  
12 VDC  
16.7 mA  
720
Ω  
24 VDC  
8.3 mA  
2,880
Ω  
Rated current  
Coil resistance  
Must operate voltage  
Must release voltage  
Maximum voltage  
Power consumption  
80% of max. of rated voltage  
10% min. of rated voltage  
150% of rated voltage  
Approx. 200 mW  
Single-coil Latching Relays (G6WU-1F, G6WU-1P)  
Rated voltage  
9 VDC  
12 VDC  
Rated current  
22.2 mA  
16.7 mA  
Coil resistance  
Must set voltage  
Must reset voltage  
Maximum voltage  
Power consumption  
405
Ω  
720
Ω  
80% max. of rated voltage  
80% max of rated voltage  
150% of rated voltage  
Approx. 200 mW  
Dual-coil Latching Relays (G6WK-1F, G6WK-1P)  
Rated voltage  
3 VDC  
120 mA  
25
Ω  
4.5 VDC  
80 mA  
56
Ω  
9 VDC  
12 VDC  
30 mA  
400
Ω  
24 VDC  
15 mA  
Rated current  
40 mA  
Coil resistance  
Must set voltage  
Must reset voltage  
Maximum voltage  
Power consumption  
225
Ω  
1,600
Ω  
80% max. of rated voltage  
80% max. of rated voltage  
150% of rated voltage  
Approx. 360 mW  
Note: 1.
 
The rated current and coil resistance are measured at a coil temperature of 23
°
C with a tolerance of
±
10%.  
2.
The operating characteristics are measured at a coil temperature of 23
°
C.  
3.
The maximum voltage is the highest voltage that can be imposed on the relay coil.  
4.
The voltage measurements for operate/release and set/reset are the values obtained for instantaneous changes in the voltage.  
(Rectangular wave).  
328  
High-frequency Relay
 
G6W  

DISCONTINUED  
■
Characteristics  
Item  
Non-latching  
G6W-1F, G6W-1P  
100 m
Ω
max.  
Single-coil latching  
G6WU-1
F
,
G
6WU-1P  
Dual-coil latching  
G6WK-1
F
,
G
6WK-1P  
Contact resistance (See note 2)  
Operate (set) time (See note 3)  
Release (reset) time (See note 3)  
Minimum set/reset signal width  
Insulation resistance (See note 4)  
10 ms max. (Approx. 3.5 ms)
 
10 ms max. (Approx. 2.5 ms)  
10 ms max. (Approx. 2.5 ms)  
—–  
12 ms  
1,000 M
Ω
min. (at 500 VDC)  
1,000 VAC, 50/60 Hz for 1 min  
500 VAC, 50/60 Hz for 1 min  
Dielectric strength  
Coil and contacts  
Coil and ground,  
contacts and ground  
Contact of same  
polarity  
500 VAC, 50/60 Hz for 1 min  
Vibration resistance  
Shock resistance  
Destruction  
Malfunction  
Destruction  
Malfunction  
Mechanical  
Electrical  
10 to 55 Hz, 1.5-mm double amplitude  
10 to 55 Hz, 2-mm double amplitude  
1,000 m/s

2  

500 m/s

2  

Endurance  
1,000,000 operations min. (at 36,000 operations/hour)  
300,000 operations min. (with a rated load at 1,800 operations/hour)  
100,000 operations min. (2.5GHz, 50
Ω
, 10 W)  
Ambient temperature  
Ambient humidity  
Weight  
Operating: -40
°
C to 70
°
C (with no icing or condensation)  
Operating: 5% to 85%  
Approx. 3 g  
Note: 1.
 
The above values are initial values.  
2.
The contact resistance was measured with 10 mA at 1 VDC with a fall-of-potential method.  
3.
Values in parentheses are typical values.  
4.
The insulation resistance was measured with a 500-VDC Megger
T
e
ster applied to the same parts as those used for checking the dielectric strength.  
Engineering Data  
Ambient Temperature vs.  
Maximum Voltage  
Ambient Temperature vs.  
Must Set or Must Reset Voltage  
Shock Malfunction  
250  
Y
100  
Max. estimated value  
1,000  
Energized  
90  
80  
70  
60  
50  
40  
30  
20  
max.  
avg.  
max.  
avg.  
min.  
min.  
800  
600  
400  
200  
200  
X
Z
Not  
energized  
1,000  
1,000  
150  
100  
200  
400  
600  
800  
1,000  
Z’  
1,000  
X’  
Shock direction  
50  
0
X
X’  
Unit: m/s

2  

Sample: G6WK-1P
 
4.5 VDC  
Number of Relays: 10  
Y
10  
0
Must set voltage  
Must reset voltage  
1,000  
Z
Y’  
Z’  
−
40  
−
20  
0
20  
40  
60  
80 100  
−
60
−
40
−
20  
0
20  
40  
60  
80 100  
Y’  
Ambient temperature (
°
C)  
Ambient temperature (
°
C)  
Conditions: Shock is applied in
±
X,
±
Y
,
a
nd  
±
Z directions three times each with and  
without energizing the relays to check the  
number of contact malfunctions.  
Note:
“Maximum voltage” is the maximum  
voltage that can be applied to the relay  
coil.  
High-frequency Relay
 
G6W  
329  

DISCONTINUED  
Electrical Endurance, DC Load:  
Must Set and Must Reset Voltage  
(See notes 1 and 2)  
Electrical Endurance, AC Load:  
Must Set and Must ResetVoltage  
(See notes 1 and 2)  
100  
100  
80  
80  
Must set voltage  
max.  
max.  
Must set voltage  
60  
max.  
max.  
60  
min.  
min.  
min.  
min.  
Must reset voltage  
40  
Must reset voltage  
40  
Sample: G6WU-1P
 
9 VDC  
Number of Relays: 5  
Sample: G6WU-1P
 
9 VDC  
Number of Relays: 5  
20  
20  
Test conditions: 10-mA resistive load at  
30-VDC with an operation rate of 50%.  
Switching frequency: 1,800 operations/h  
Test conditions: 10-mA resistive load at  
30-VAC with an operation rate of 50%.  
Switching frequency: 1,800 operations/h  
0
0
0.001 0.01  
0.1  
1
10  
100 1,000  
0.001 0.01  
0.1  
1
10  
100 1,000  
Operating frequency (
×
10

3

operations)  
Operating frequency (
×
10

3

operations)  
Electrical Endurance, DC Load:  
Contact Resistance  
(See notes 1 and 2)  
1,000  
Electrical Endurance, AC Load:  
Contact Resistance  
(See notes 1 and 2)  
1,000  
Sample: G6WU-1P
 
9 VDC  
NO contact  
Sample: G6WU-1P
 
9 VDC  
NO contact  
Number of Relays: 5  
Test conditions:  
Number of Relays: 5  
NC contact  
Test conditions:  
NC contact  
10-mA resistive load at 30-VAC  
Switching frequency: 1,800 operations/h  
500  
300  
500  
300  
10-mA resistive load at 30-VDC  
Switching frequency: 1,800 operations/h  
100  
100  
50  
30  
50  
30  
Contact resistance  
Contact resistance  
max.  
max.  
max.  
min.  
min.  
max.  
min.  
min.  
10  
10  
0.001 0.01  
0.1  
1
10  
100 1,000  
0.001 0.01  
0.1  
1
10  
100 1,000  
Operating frequency (
×
10

3

operations)  
Operating frequency (
×
10

3

operations)  
External Magnetic Interference  
(Average value)  
(Average value)  
(Average value)  
N
+30  
+20  
+30  
+20  
+30  
+20  
Sample: G6WK-1P 4.5 VDC  
Number of Relays: 5  
Sample: G6WK-1P 4.5 VDC  
Number of Relays: 5  
Sample: G6WK-1P 4.5 VDC  
Number of Relays: 5  
S
N
S
N
S
+10  
0
+10  
0
+10  
0
−
10  
−
10  
−
10  
−
20  
−
30  
−
20  
−
30  
−
20  
−
30  
Must set voltage  
Must reset voltage  
Must set voltage  
Must reset voltage  
Must set voltage  
Must reset voltage  
−
1,200
−
800  
−
400  
0
400  
800 1,200  
−
1,200
−
800  
−
400  
0
400  
800 1,200  
−
1,200
−
800  
−
400  
0
400  
800 1,200  
External magnetic field (A/m)  
External magnetic field (A/m)  
External magnetic field (A/m)  
Note: 1.
 
The tests were conducted at an ambient temperature of 23
°
C  
2.
The contact resistance data are periodically measured reference values and are not values from monitoring each operation.  
Contact resistance values will vary according to the switching frequency and operating environment. Therefore, be sure to check  
the operation under the actual operating conditions before use.  
330  
High-frequency Relay
 
G6W  

DISCONTINUED  
Isolation  
(See notes 1 and 2)  
Insertion Loss  
(See notes 1 and 2)  
V.S.W.R. / Return Loss  
(See notes 1 and 2)  
[Average (Initial value)]  
[Average (Initial value)]  
[A
v
erage (Initial
v
al
u
e)]  
0
0
0
2.4  
2.2  
N
.O.  
N
.C.  
10  
20  
0.2  
0.4  
0.6  
Ret
u
rn loss  
20  
30  
40  
50  
2.0  
1.
8  
1.6  
1.4  
40  
60  
80  
V
.S.
W
.R.  
0.8  
1.0  
100  
120  
60  
70  
1.2  
1.0  
N.O.  
N.C.  
N.O.  
N.C.  
0
1,000 2,000 3,000 4,000 5,000
 
6,000  
Frequency (MHz)  
0
1,000 2,000 3,000 4,000 5,000
 
6,000  
Frequency (MHz)  
0
1,000 2,000 3,000 4,000 5,000
 
6,000  
Fre
qu
ency (MHz)  
Must Set and Must Reset  
Time Distribution (see note 1).  
Must Set and Must Reset  
Bounce Time Distribution (see note 1).  
20  
30  
Sample:  
G6WK-1P 4.5 VDC  
Number of Relays: 20  
Sample:  
G6WK-1P 4.5 VDC  
Number of Relays:
20  
Must set time  
Must reset time  
Must set bounce time  
Must reset bounce time  
25  
20  
15  
10  
5
15  
10  
5
0
0.5  
1.0  
1.5  
2.0  
2.5  
3.0 3.5  
0
0.5  
1.0  
1.5  
2.0  
2.5  
3.0  
Time (ms)  
Time (ms)  
Note: 1.
 
The tests were conducted at an ambient temperature of 23
°
C.  
2.
High-frequency characteristics depend upon the PCB to which the relay is mounted. Always check these characteristics, including en-  
durance (life expectancy) in the actual application before use.  
Dimensions  
Note:
All units are in millimeters unless otherwise indicated.  
Terminal Arran
g
ement/  
Internal Connections  
(Top View)  
Mountin
g
Pads  
G6W-1F  
G6WU-1F  
(Top View)  
Tolerance: 0.1
 
mm  
G6W-1F  
2.54 2.54 2.54 2.54
 
5.0
8  
Orientation mark  
3.2  
17  
15 14 13  
11  
7
1
8  
10  
+
−
2.7 1.
8  
5.0
8
9.4  
20  
8
1
2
3
5
6
1.1  
20  
9.4  
5.9  
3
2.
8  
1.1  
8
.6  
G6WU-1F  
Orientation mark  
Thro
u
gh-hole  
20.4  
9.2  
17  
15 14 13  
11  
7
1
8  
10  
S
R
+
−
T
w
el
v
e, 0.6  
15.24  
Three,  
0.4  
0.2  
0.2  
−
+
5.0
8  
22.2  
11.6  
20  
8
Note: 1.
Tolerance: 0.3
 
mm
u
nless specified.  
2.
The coplanarity of the terminals is 0.1 mm max.  
1
2
3
5
6
High-frequency Relay
 
G6W  
331  

DISCONTINUED  
Mountin
g
Holes  
(Bottom View)  
Tolerance: 0.1
 
mm  
Terminal Arran
g
ement/  
Internal Connections  
(Bottom View)  
G6W-1P  
G6WU-1P  
G6W-1P  
Orientation mark  
2.54 2.54 2.54 2.54 2.54 2.54  
1.6-dia.  
0.
8
-dia.  
0.
8
-dia.  
1.6-dia.  
1
2
3
5
6
7
20  
8
2.7  
1.
8
5.0
8
7.62  
+
−
1
8  
10  
T
w
el
v
e, 1-dia.  
17  
15 14  
13  
11  
20  
9.4  
T
w
el
v
e, 1.
8
-dia.  
3
5.9  
8
.6  
Thro
u
gh-hole  
G6WU-1P  
Orientation mark  
19  
0.
8
-dia.  
1.6-dia.  
8
.9  
1
2
3
5
6
7
20  
8
S
R
+
−
T
w
el
v
e,  
0.6  
5.0
8  
10.16  
15.24  
19  
Three,  
0.4  
5.0
8  
−
+
7.6  
1
8  
10  
17  
15 14  
13  
11  
Note:
Tolerance: 0.3
 
mm
u
nless specified.  
Mountin
g
Pads  
Terminal Arran
g
ement/  
Internal Connections  
(Top View)  
G6WK-1F  
(Top View)  
Tolerance: 0.1
 
mm  
G6WK-1F  
2.54 2.54 2.54 2.54
 
5.0
8  
Orientation mark  
3.2  
17 16  
1514  
13  
+
11  
7
1
8  
10  
−
R
+
−
S
2.7 1.
8  
5.0
8  
9.4  
20  
9.4  
20  
8
1
2
3
5
6
1.1  
9.2  
5.9  
3
2.
8  
1.1  
8
.6  
Thro
u
gh-  
hole  
20.4  
Thirteen, 0.6  
15.24  
Three,  
0.4  
0.2  
0.2  
5.0
8  
22.2  
11.6  
Note: 1.
Tolerance: 0.3
 
mm
u
nless specified.  
2.
The coplanarity of the terminals is 0.1 mm max.  
Mountin
g
Holes  
Terminal Arran
g
ement/  
Internal Connections  
(Bottom View)  
G6WK-1P  
(Bottom View)  
Tolerance: 0.1
 
mm  
G6WK-1P  
Orientation mark  
2.54 2.54 2.54 2.54 2.54 2.54  
1.6-dia.  
0.
8
-dia.  
0.
8
-dia.  
1.6-dia.  
1
2
3
5
6
7
20  
8
+
−
S
2.7  
1.
8  
5.0
8
7.62  
20  
9.4  
+
−
R
1
8  
10  
Thirteen, 1-dia.  
17 16  
15 14  
13  
11  
Thirteen, 1.
8
-dia.  
8
.9  
3
5.9  
8
.6  
Thro
u
gh-hole  
19  
0.
8
-dia.  
1.6-dia.  
Thirteen,  
0.6  
5.0
8  
10.16  
15.24  
19  
Three,  
0.4  
5.0
8  
7.6  
Note:
Tolerance: 0.3
 
mm
u
nless specified.  
332  
High-frequency Relay
 
G6W  

DISCONTINUED  
Recommended Soldering Method  
■
Temperature Profile According to IRS Method  
When performing reflow-soldering, check the profile on an actual device  
after setting the temperature condition so that the temperatures at the  
relay terminals and the upper surface of the case do not exceed the  
limits specified in the following table.  
The thickness of cream solder to be applied should be within a range  
between 150 and 200
μ
m on OMRON’s recommended PCB pattern.  
Correct Soldering  
Incorrect Soldering  
Relay  
Excessive  
amount of  
solder  
Insufficient  
amount of  
solder  
T4  
T3  
Terminal  
Solder  
PCB  
Land  
T2  
T1  
Visually check that the Relay is properly soldered.  
Bottom Ground Soldering Conditions  
To
s
older the bottom ground, manually solder separately from the  
terminals according to the following conditions.  
•
Soldering iron: 50 W  
•
Iron temperature: 380
°
C to 400
°
C  
•
Soldering time: 10 s max.  
t
2
t
1
Note:
The above conditions are for a PCB with OMRON’s recommended  
patterns and hole perforations. The conditions will depend on the  
PCB being used. Therefore, it is recommended to double-check  
the suitability under actual PCB conditions.  
Preheating  
Soldering  
Time (s)  
Item  
Preheating  
Soldering  
(T3, t

2

)  
Peak value  
(T4)  
Soldering  
Measuring  
position  
(T1 to T2, t

1

)  
Soldering temperature: Approx. 250  
used.)  
°
C (At 260
°
C if the DWS method is  
Terminal  
150
°
C to 180
°
C, 230
°
C min.,  
250
°
C max.  
255
°
C max.  
120 s max.  
30 s max.  
Soldering time: Approx. 5 s max. (approx. 2 s for the first time and  
approx. 3 s for the second time if the DWS method is used.)  
Upper surface
 
—  
of case  
—  
Be sure to adjust the level of the molten solder so that the solder will not  
overflow onto the PCB.  
Precautions  
Claw Securing Force During Automatic Insertion  
■
Correct Use  
During automatic insertion of Relays, make sure to set the securing force  
of the claws to the following values so that the Relay characteristics will  
be maintained.  
Handling  
Use the Relay as soon as possible after opening the moisture-proof  
package. If the Relay is left for a long time after opening the moisture-  
proof package, the appearance may suffer and seal failure may occur  
after the solder mounting process.
T
o
s
tore the Relay after opening the  
moisture-proof package, place it into the original package and sealed the  
package with adhesive tape.  
C
B
A
When washing the product after soldering the Relay to a PCB, use a  
water-based solvent or alcohol-based solvent, and keep the solvent tem-  
perature to less than 40
°
C. Do not put the Relay in a cold cleaning bath  
immediately after soldering.  
Direction A: 4.90 N max.  
Direction B: 9.80 N max.  
Direction C: 9.80 N max.  
Dropping the Relay may cause damage to its functional capabilit
y
.  
Never use the Relay if it is dropped.  
Secure the claws to the area indicated by shading.  
Do not attach them to the center area or to only part of the  
Relay.  
Protect the Relays from direct sunlight during operation, storage, and  
transportation and keep the relays under normal temperature, humidit
y
,  
and pressure.  
Latching Relay Mounting  
Coating  
Make sure that the vibration or shock that is generated from other  
devices, such as relays in operation, on the same panel and imposed on  
the Latching Relay does not exceed the rated value, otherwise the Latch-  
ing Relay that has been set may be reset or vice versa. The Latching  
Relay is reset before shipping. If excessive vibration or shock is imposed,  
however, the Latching Relay may be set accidentall
y
.
B
e sure to apply a  
reset signal before use.  
Do not use silicone coating to coat the Relay when it is mounted to  
the PCB. Do not wash the PCB after the Relay is mounted using  
detergent containing silicone. Otherwise, the detergent may remain  
on the surface of the Rela
y
.  
High-frequency Relay
 
G6W  
333  

DISCONTINUED  
■
High-frequency Characteristics Measurement Method and Substrate to be Measured  
High-frequency Characteristics for G6W are measured as shown below.  
G6W-1  
Vector network analyzer  
(Manufacture:  
Agilent
T
e
chnologies)  
50- termination  
resistances  
HP8753D  
Through-hole substrate  
SMD-type substrate  
Substrate: t-0.8 BT resin (Dielectric constant at 2 GHz: 3.37)  
Substrate: t-0.8 BT resin (Dielectric constant at 2 GHz: 3.37)  
1.5  
1.4  
1.5  
0.5 0.5  
0.4  
0.5  
0.4  
1.8-dia.  
4.5  
Through-  
hole  
Through-hole  
1.8  
1.5  
20  
1.8 5.12  
R0.6  
6
1.5  
45
°
 
45
°  
1.5  
0.5  
0.5  
R2.1  
0.5  
T
w
enty seven,  
0.6-dia.,  
through-hole  
3
3
3
3
Thirty one, 0.6-dia.,  
through-hole  
8.6  
30  
8.6  
15.24  
Undersurface of relay  
Undersurface of relay  
Convex position  
Convex position  
Note:
T
o
o
btain high-frequency characteristics close to those specified in this datasheet, solder the convex point on the undersurface of the relay  
to the ground pattern of the substrate.  
Base plate for high-frequency characteristic compensation  
Twenty four, 0.6-dia.,  
through-hole  
2
13.6  
0.5  
1.5 15  
Note:
The above compensation plate is used to measure the loss by  
the rela
y
.  
The relay loss is determined by subtracting the data measured  
for a compensation base plate from those for a high-frequency  
characteristics measuring substrate mounted with a rela
y
.  
334  
High-frequency Relay
 
G6W  

DISCONTINUED  
MEMO  
High-frequency Relay
 
G6W  

DISCONTINUED  
All sales are subject to Omron Electronic Components LLC standard terms and conditions of sale, which  
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.  
To
c
onvert millimeters into inches, multiply by 0.03937.
T
o
c
onvert grams into ounces, multiply by 0.03527.  
OMRON ON-LINE  
OMRON ELECTRONIC  
COMPONENTS LLC  
55 E. Commerce Drive, Suite B  
Schaumburg, IL 60173  
847-882-2288  
12/10  
Specifications subject to change without notice  
Printed in USA  
Cat. No. X302-E-1  
High-frequency Relay
 