Omron-Electronics-G8P-1C4TP-DC24
| Part # | Omron-Electronics-G8P-1C4TP-DC24 |
| Download | Omron-Electronics-G8P-1C4TP-DC24 |
Scheduled to be Discontinued at the end of April 2015
G
Po
w
8
er
P
P
C
B
T
Relay
• Up to 30 A switching capacity in compact package.
•
NEW
G8P-1A4P-BG with 2.0 mm contact gap and high
dielectric strength of 4,000 VAC
• Available with quick-connect contact terminals for easy load
connecting with either QC or PCB coil terminals.
• UL Class F coil insulation standard
• Minimum 6 kV Impulse Surge Withstand.
• Ideal for home and industrial appliances, HVAC and many
other applications.
• UL recognized / CSA certified. VDE approved.
• RoHS Compliant
Ordering Information
To
O
rder: Select the part number and add the desired coil voltage rating, (e.g., G8P-1A4P-
DC12
).
Mounting type
Contact form
Construction
Model
PCB
SPS
T
–
NO
Open frame
G8P-1AP
G8P-1A4P-BG
G8P-1A4P
G8P-1CP
Sealed with ventable nib*
SPDT
Open frame
Sealed with ventable nib*
Open frame
G8P-1C4P
G8P-1
A
T
P
G8P-1A4TP
G8P-1CTP
G8P-1C4TP
G8P-1A2
T
–
F
G8P-1C2
T
–
F
PCB & Quick Connect
load terminals
SPS
T
–
NO
SPDT
Sealed with ventable nib*
Open frame
Sealed with ventable nib*
Vented
Flange mount Quick
Connect terminals
SPS
T
–
NO
SPDT
Vented
Note: 1.
Load terminals are .250” Quick Connect. Coil terminals on Flange Mount versions are .187” Quick Connect.
2.
“-BG” version available with 12 VDC and 24 VDC coils, onl
y
.
3.
Packaged with 50 pcs per tra
y
.
* Sealed and vented optional.
Specifications
■
Contact Data
Type
SPS
T
–
NO
SPDT
Rated load
30 A 250 VAC (-BG: 20 A 250 VAC), 20 A 28 VDC (-BG: – – -)
20/10 A* at 250 VAC, 20/10 A* at 28 VDC
Ag-Alloy (Cd free)
Contact material
Rated Carry current
Max. operating voltage
Max. operating current
Max. switching capacity
Min. permissible load
30 A max. (-BG: 20 A)
20/10 A*
250 VAC, 28 VDC (-BG: 250 VAC)
AC 30 A, DC 20 A (-BG: AC 20 A)
7,500 VA, 560 W (-BG: 5,000 VA)
AC 20/10 A, DC 20/10 A*
5,000/2,500 VA, 560/280 W*
500 mA@ 5 VDC (See note 1), 100 mA @ 5 VDC (See note 2)
* NO contact/NC contact
Note: 1.
Applicable for G8P-1A4T
P
,
G
8P-1C
P
,
G
8P-1C4
P
,
G
8P-1C4TP and G8P-1C2
T
–
F versions.
2.
Applicable for G8P-1A
P
,
G
8P-1A4P(-BG), G8P-1
A
T
P and G8P-1CTP versions.
Power PCB Relay
G8PT
247
Scheduled to be Discontinued at the end of April 2015
■
Coil Data
Rated
voltage
(VDC)
Rated
current
(mA)
Coil
resistance
(
Ω
)
Pick-up
voltage
Dropout
voltage
Maximum
voltage
Power
consumption
(mW)
% of rated voltage
5
185
93
77
36
19
9
27
97
75% max.
10% min.
120% max.
Approx. 900
9
12
24
48
110
155
660
2,480
12,400
Note: 1.
The rated current and coil resistance are measured at a coil temperature of 23
°
C with tolerances of
10%.
2.
The operating characteristics are measured at a coil temperature of 23
°
C.
3.
The “Maximum Voltage is the maximum voltage that can be applied to the relay coil.
■
Characteristics
Contact resistance
100 m
Ω
max. (measured with 5 VDC, 1 A, voltage drop method)
15 ms. max. (-BG: 20 ms max.)
10 ms. max.
Operate time
Release time
Insulation resistance (See note 2)
Dielectric strength
100 M
Ω
min. (at 500 VDC)
2,500 VAC, 50/60 Hz for 1 minute (between coil and contacts), (-BG: 4,000 VAC)
1,500 VAC, 50/60 Hz for 1 minute (between contacts of the same polarity)
6,000 V between coil and contacts (1.2/50
μ
s)
Impulse surge withstand
Vibration resistance
Destruction
10 to 55 Hz, 1.65 mm double amplitude for 2 hours
(-BG: 10 to 55 Hz, 1.5 mm double amplitude for 2 hours)
Malfunction
Destruction
Malfunction
10 to 55 Hz, 1.65 mm double amplitude for 5 minutes
1,000 m/s
2
(approx. 100 G)
100 m/s
2
(approx. 10 G)
Shock resistance
Ambient operating temperature
-55
°
to 105
°
C, cold coil condition (with no icing)
-55
°
to 85
°
C, hot coil condition (hot start) (with no icing)
5% to 85% RH
Ambient operating humidity
Service life
Weight
Mechanical
Electrical
10 million operations minimum at 18,000 ops/hour.
(-BG: 5 million operations min.)
100,000 operations approx. at 360 ops/hr.
(-BG: 40,000 operations min.)
Approx. 24 g to 31 g
Note: 1.
Data shown are of initial value. Operate and release times excluding bounce.
2.
Measurement conditions: Measured at the same points as the dielectric strength using a 500 VDC ohmmeter.
3.
Please vent sealed relays after processing in order to achieve rated electrical service life, by removing the vent nib.
■
Characteristic Data
Maximum switching capacity
SPS
T
–
NO
SPDT
AC resistive load
(-BG type)
Rated operating voltage (V)
Rated operating voltage (V)
248
Power PCB Relay
G8PT
Scheduled to be Discontinued at the end of April 2015
■
Characteristic Data
Electrical service life
SPS
T
–
NO
SPDT
Load current (A)
*Except (-BG) type
Load current (A)
Dimensions
Unit: mm (inch)
■
Relays
G8P-1CP / 1AP
Open frame, PCB terminals
Terminal arrangement/
Internal connections
(Bottom view)
Mounting holes
(Bottom view)
Note:
T
e
rminal #4 is omitted
on G8P-1A
P
.
Power PCB Relay
G8PT
249
Scheduled to be Discontinued at the end of April 2015
Unit: mm (inch)
G8P-1C4P / 1A4P / 1C2P / 1A2P
Sealed/Ventable, PCB terminals
Terminal arrangement/
Internal connections
(Bottom view)
Mounting holes
(Bottom view)
Note:
T
e
rminal #4 is omitted
on G8P-1A4P/1A2
P
.
Pin Dimensions
large = 1.6 x 1.2; 1.2 x 0.8 x 3.3L
small = 0.6 x 0.5 x 3.3L
G8P-1CTP / 1ATP
Open frame, PCB with
Quick Connect terminals
Mounting holes
(Bottom view)
Terminal arrangement/
Internal connections
(Bottom view)
Note:
T
e
rminal #4 is omitted
on G8P-1
A
T
P
.
Pin Dimensions
large = 1.6 x 1.2; 1.2 x 0.8 x 3.3L
small = 0.6 x 0.5 x 3.3L
250
Power PCB Relay
G8PT
Scheduled to be Discontinued at the end of April 2015
Unit: mm (inch)
G8P-1C4TP / 1A4TP / 1C2TP / 1A2TP
Mounting holes
(Bottom view)
Sealed/Ventable, PCB with Quick Connect
terminals
Terminal arrangement/
Internal connections
(Bottom view)
Note:
T
e
rminal #4 is omitted
on G8P-1A4TP/1A2T
P
.
Pin Dimensions
large = 1.6 x 1.2; 1.2 x 0.8 x 3.3L
small = 0.6 x 0.5 x 3.3L
G8P-1C2T-F / 1A2T-F
Flange mount
Terminal arrangement/
Internal connections
(Bottom view)
Mounting holes
(Bottom view)
Note:
T
e
rminal #4 is omitted
on G8P-1A2
T
–
F
.
Note:
Allow air circulation within the sealed type G8PT by removing the ventilation nib from the cover after soldering and cleaning is complete.
Power PCB Relay
G8PT
251
Scheduled to be Discontinued at the end of April 2015
■
Approvals
UL Recognized (File No. E41643), CSA Certified (File No. LR31928)
Model
G8P-1AP
G8P-1A4P
G8P-1
A
T
P
G8P-1A4TP
G8P-1A2
T
–
F
Contact form
SPS
T
–
NO
Coil ratings
Contact ratings
5 to 110 VDC
30 A, 240 VAC (G.
P
.
/Res.), 40
°
C, 50,000 cycles
20 A, 28 VDC (Res.), 40
°
C, 6,000 cycles
20 A, 240 VAC (Res.), 70
°
C, 100,000 cycles
23 A, 240 VAC (Res.), 85
°
C, 100,000 cycles
1 H
P
,
1
25-250 VAC, 40
°
C, 1,000 cycles
2 H
P
,
2
50 VAC, 40
°
C, 1,000 cycles
A300 Pilot Dut
y
,
4
0
°
C, 6,000 cycles
20 FLA, 96 LRA, 125 VAC, 40
°
C, 100,000 cycles
5 A, 250 VAC (
T
u
ngsten), 40
°
C, 6,000 cycles
20 A, 120-277 VAC (Ballast), 40
°
C, 6,000 cycles
TV-5, 40
°
C, 25,000 cycles
G8P-1A4P-BG
30 A, 277 VAC (Res.), 85
°
C, 30,000 cycles
G8P-1CP
SPDT
5 to 110 VDC
NO/NC
G8P-1C4P
G8P-1CTP
G8P-1C4TP
G8P-1C2
T
–
F
30 A/20 A, 277 VAC (Res.), 40
°
C, 100,000 cycles (N.O.) and 30,000 cycles (N.C.)
20 A/15 A, 250 VAC (Res.), 105
°
C, 100,000 cycles (N.O.) and 30,000 cycles (N.C.)
20 A/10 A, 28 VDC (Res.), 40
°
C, 6,000 cycles
30 A/30 A, 277 VAC(Res.), 40
°
C, 10,000 cycles
1/2 HP/1/2 H
P
,
1
25 VAC, 40
°
C, 100,000 cycles
2 HP/ 1/2 H
P
,
2
50 VAC, 40
°
C, 1,000 cycles
1 HP/ 1/4 H
P
,
1
25 VAC, 40
°
C, 1,000 cycles
B150 Pilot Dut
y
,
4
0
°
C, 100,000 cycles
5 A/ 3 A, 250 VAC (
T
u
ngsten), 40
°
C, 6,000 cycles
6 A/ 3 A, 277 VAC (Ballast), 40
°
C, 6,000 cycles
TV-5 (N.O.), 40
°
C, 25,000 cycles
VDE recognized type (Licence No. 40004714)
Note: 1.
The rated values approved by each of the safety standards (e.g., UL, CSA) may be different from the performance characteristics
individually defined in this catalog.
2.
For information on additional ratings not included in this catalog, contact your local Omron Representative.
3.
In the interest of product improvement, specifications are subject to change.
4.
Please contact Omron for details regarding VDE approvals.
5.
Meets requirements of polluiton degree 2 with Material II & III.
Precautions
Recommended soldering condition
Pre-heat at 120
°
C maximum within 120 seconds.
Complete solering at 265
°
C maximum within 6 seconds.
Re: the Electrical Appliance and Material Safety Law (Japan)
The G8P series is not compliant with the Electrical Appliance and
Material Safety Law of Japan.
Pay careful attention to select a suit-
able Relay for the application.
252
Power PCB Relay
G8PT
Scheduled to be Discontinued at the end of April 2015
MEMO
Power PCB Relay
G8PT
Scheduled to be Discontinued at the end of April 2015
All sales are subject to Omron Electronic Components LLC standard terms and conditions of sale, which
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To
c
onvert millimeters into inches, multiply by 0.03937.
T
o
c
onvert grams into ounces, multiply by 0.03527.
OMRON ON-LINE
OMRON ELECTRONIC
COMPONENTS LLC
55 E. Commerce Drive, Suite B
Schaumburg, IL 60173
847-882-2288
Cat. No. X301-E-1d
12/14 (08/12)
Specifications subject to change without notice
Printed in USA
Power PCB Relay
G8PT