Omron-Electronics-G9TA-U1AP-DC12
| Part # | Omron-Electronics-G9TA-U1AP-DC12 |
| Download | Omron-Electronics-G9TA-U1AP-DC12 |
G9TA
AC Power Latching Relay
60 A High power latching relay
• High power switching, Compact size
• High magnetic latching force provides vibration resistance
• Low contact resistance
• PCB terminals type available
• Conforms to UL 508 (Except PCB terminals type)
RoHS Compliant
Model Number Structure
Application Examples
• Smart Meter
• Lighting control
G9TA
–
1 A
• PV Inverter
• EV Charger
1 2 3
4
2. Number
of poles
1: 1-Pole
1. Relay
Function
U: Single-winding latching
K: Double-winding latching
G
9
T
A
3. Contact
Form
A: SPST-NO
4. Terminal
shape
TH: M5 securing screw
TW: Welding terminals
P: PCB terminals
Ordering Information
Classification
Contact Form
Terminal Shape
M5 securing screw
Welding terminals
PCB terminals
M5 securing screw
Welding terminals
PCB terminals
Enclosure rating
Flux protection
Model
Rated coil voltage
Minimum packing unit
G9TA-U1ATH
G9TA-U1ATW
G9TA-U1AP
G9TA-K1ATH
G9TA-K1ATW
G9TA-K1AP
Single coil
12 VDC
12 VDC
SPST-NO
25 pcs/tray
Double coils
Note. When ordering, add the rated coil voltage to the model number.
Example: G9TA-U1ATH DC12
Rated coil voltage
However, the notation of the coil voltage on the product case as well as on the packing will be marked as[][] VDC.
Ratings
Coil
Single-winding Latching Type
Must reset
voltage
% of rated voltage
80% max.
Item
Must set voltage
80% max.
Max. voltage
Power consumption
Rated current (mA)
83
Coil resistance (
Ω
)
Rated Voltage
DC
(V)
Set coil (W)
Reset coil (W)
12
145
110% max.
Approx. 1.0
Double-winding Latching Type
Must reset
voltage
% of rated voltage
80% max.
Item Rated
current (mA)
(V) Set
coil Reset
coil Set
coil Reset
coil
217 217
55 55
Coil resistance (
Ω
) Must
set voltage
Max. voltage
110% max.
Power consumption
Rated Voltage
DC
Set coil (W)
Approx. 2.6
Reset coil (W)
Approx. 2.6
12
80% max.
Note 1. The rated current and coil resistance were measured at a coil temperature of 23°C with tolerances of ± 10%.
Note 2. The operating characteristics are measured at a coil temperature of 23°C.
Note 3. The maximum permissible voltage is the maximum value of the fluctuation range for the Relay coil operating power supply and was measured at an ambient
temperature of 23°C.
Contacts
Model
Load
G9TA-U1A
/G9TA-K1A
Resistive load
Inductive load (PF=0.5)
Item
Contact type
Contact material
Rated load
SPST-NO
Ag Alloy
60 A at 250 VAC
Rated carry current
Max. switching voltage
Max. switching current
60 A
250 VAC
60 A
1
G9TA
AC Power Latching Relay
Characteristics
Item
G9TA-U1A
G9TA-K1A
Contact resistance *1
Set time *2
2 m
Ω
max.
30 ms max.
30 ms max.
100 ms
20 ms max.
20 ms max.
Reset time *2
Minimum pulse width
Maximum pulse width
Insulation resistance *3
1,000 ms
1,000 M
Ω
min.
Between coil and contacts
4,000 VAC, 50/60 Hz for 1 min
Dielectric strength
Between contacts of the
same polarity
1,500 VAC, 50/60 Hz for 1 min
Impulse withstand
voltage
Between coil and contacts
6 kV
Destruction
Malfunction
Destruction
Malfunction
Mechanical
10 to 150 to 10 Hz, f < 60 Hz: Constant amplitude 0.075 mm, f > 60 Hz: Constant acceleration 9.8 m/s
2
Vibration resistance
Shock resistance
10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
1,000 m/s
2
100 m/s
2
100,000 operations min. (at 7,200 operations/h)
Durability
5,000 operations, resistive load and then
5,000 operations, inductive load (PF=0.5) (operation: ON for 10 sec, OFF for 20 sec) *5
Electrical *4
Ambient operating temperature
Ambient operating humidity
Weight
-40 to 85°C (with no icing or condensation)
5 to 85%
G
9
T
A
Approx. 42 g
Note. The values given above are initial values.
*1. Measurement
conditions: 24 VDC, 1 A, voltage drop method.
*2. Measurement
conditions: Rated operating voltage applied, not including contact bounce.
Ambient temperature: 23°C
*3. Measurement
conditions: The insulation resistance was measured with a 500 VDC megohm meter at the same locations as the dielectric strength was measured.
*4. Contact
your OMRON sales representative for Electrical Durability technical data.
*5. The
characteristic meets IEC62055-31 test requirement.
2
G9TA
Dimensions
AC Power Latching Relay
Please visit our website, which is noted on the last page.
CAD Data
(Unit: mm)
G9TA-U1ATH
39.1 max.
Terminal arrangement/Internal Connections
(TOP VIEW)
34.5 max.
4
S
R
–
30
–
3
4
1
2
4.95
9.9
4
5
10
5
Check carefully the coil polarity of the Relay.
6.7
10
4.65
9.3
Two,
ꢀ
5.5 dia.
5
0.05
7.7
18.55
Two,
ꢀ
0.64 0.01
18 max.
14.2
3.7
1
1
3.7
CAD Data
G
9
T
A
G9TA-U1ATW
39.1 max.
Terminal arrangement/Internal Connections
(TOP VIEW)
S
R
–
34.5 max.
30
–
1
2
3
4
4
8.8
Check carefully the coil polarity of the Relay.
5
0.05
7.7
Two,
ꢀ
0.64 0.01
18.55
10.6
12
18 max.
14.2
1
1
CAD Data
G9TA-U1AP
PCB Mounting Holes
(BOTTOM VIEW)
39.1 max.
18 max.
5
0.1
8.7 0.1
19.05 0.1
(2.8)
(3.4)
36.7 max.
30
0.6 0.1
4
4
0.1
0.1
Two,
ꢀ
1.2 0.1
5.5
Two,
ꢀ
0.64
4
4
19.05
1
8.7
5
Six,
ꢀ
2 0.1
1
6-1.5
Terminal arrangement/Internal Connection
(BOTTOM VIEW)
1
2
3
–
4
–
S
R
Check carefully the coil polarity of the Relay.
CAD Data
3
G9TA
AC Power Latching Relay
(Unit: mm)
G9TA-K1ATH
39.1 max.
Terminal arrangement/Internal Connections
(TOP VIEW)
34.5 max.
30
S
–
4
R
1
2
3
5
4
5
4
6.7
Check carefully the coil polarity of the Relay.
10
5
10
4.65
9.3
Two,
ꢀ
5.5 dia.
4.95
9.9
5
0.05
5 0.05
7.7
Three,
ꢀ
0.64 0.01
13.55
18 max.
14.2
3.7
3.7
1
1
CAD Data
G9TA-K1ATW
G
9
T
A
39.1 max.
Terminal arrangement/Internal Connections
(TOP VIEW)
34.5 max.
30
4
S
–
4
R
1
2
3
5
8.8
Check carefully the coil polarity of the Relay.
5
0.05
5
0.05
7.7
Three,
ꢀ
0.64 0.01
13.55
10.6
12
18 max.
14.2
CAD Data
1
1
G9TA-K1AP
PCB Mounting Holes
(BOTTOM VIEW)
18 max.
39.1 max.
5
0.1 5 0.1
8.7 0.1
14.05 0.1
(2.8)
(3.4)
36.7 max.
30
0.6 0.1
4
4
0.1
0.1
Three,
ꢀ
1.2 0.1
5.5
Three,
ꢀ
0.64
4
4
5
5
8.7
Six,
ꢀ
2 0.1
14.05
1
6-1.5
1
Terminal arrangement/Internal Connections
(BOTTOM VIEW)
1
2
3
4
–
5
S
R
Check carefully the coil polarity of the Relay.
CAD Data
Note 1. Relay is delivered as “reset” status unless specified otherwise. However, the status may change due to the shock from transportation or mounting operations.
Therefore, it is recommended the relay should be set to the expected status via a power supply before being used.
Note 2. In order to maintain “set” or “reset” status, the energizing voltage to coil & the pulse width shouldn’t lower then the rated value.
Note 3. Do not energize both of set and reset coil simultaneously.
Note 4. Energizing time longer than 1,000 ms should be avoided.
4
G9TA
AC Power Latching Relay
Engineering Data
Maximum Switching Capacity
G9TA-U1A
G9TA-K1A
1000
1000
100
100
60
AC Resistive Load
AC Inductive Load (PF=0.5)
60
10
10
1
1
1
10
100 250
1000
1
10
100 250
1000
Switching voltage (V)
Switching voltage (V)
Approved Standards
The approval rating values for overseas standards are different from the performance values determined individually. Confirm the values
before use.
UL Recognized:
(File No. E41515)
Model
Contact form
Coil ratings
Contact ratings
60 A, 277 V AC (Resistive) 70°C
Number of test operations
6,000
G
9
T
A
G9TA-U1ATH
G9TA-U1ATW
G9TA-K1ATW
G9TA-K1ATH
60 A, 250 V AC (Resistive) and then 60 A,
250 V (PF=0.5), 10 sec. ON / 20 sec. OFF,
40°C
SPST-NO (1a)
12V DC
5,000 for resistive and then
5,000 for PF=0.5
Safety Precautions
• Please refer to “PCB Relays Common Precautions” for correct use.
Correct Use
Installation
Relay Service Life
• The relay contacts are polarized. Incorrect wiring may cause a
failure to break the circuit. Wire the Relay with care.
• Install
the Relays in locations that are as dry as possible and
have as little dust, dirt, and harmful gas.
• The electrical durability of these Relays is specified as the
number of load switching operations under a resistive load and
OMRON-specified standard testing conditions.
The coil drive circuit, ambient environment, switching
frequency, or load conditions (e.g., inductive load or capacitor
load) may reduce the service life and possibly lead to failure to
break. Always confirm the service life in the actual equipment.
• Using the Relay under high temperature, high humidity, or
harmful gas may deteriorate its performance characteristics
due to condensation or corrosive materials, resulting in failure
or burn damage to the Relay.
Wiring
• Be sure to tighten all screws to the appropriate torque given below.
• Loose screws may result in burning due to abnormal heat generation during energization.
• M5 screws: 1.57 to 2.35 N·m
• Use a spring washer in order to prevent deformation and looseness.
• Allow suitable slack on leads when wiring, and do not apply excessive force to the terminals.
Please check each region’s Terms & Conditions by region website.
OMRON Corporation
Electronic and Mechanical Components Company
Regional Contact
Americas
Europe
Asia-Pacific
China
Korea
Japan
© OMRON Corporation 2018-2020
All Rights Reserved.
In the interest of product improvement, specifications are subject to change without notice.
Cat. No. J220-E1-03
0120(0318)
5