Omron-Electronics-G9YA-12S-45-P-DC24

Part #Omron-Electronics-G9YA-12S-45-P-DC24
Download 
Omron-Electronics-G9YA-12S-45-P-DC24
DISCONTINUED  
Coaxial Switch  
G9YA  
High-frequency, High-capacity Coaxial  
Switch Supporting Bandwidths to 26.5 GHz  
• Isolation of 60 dB min., insertion loss of 0.8 dB max., and  
V
.
S.W.R. of 1.7 max. at 26.5 GHz (50
Ω
).  
• Contact carry power of 120 W at 3 GHz.  
• High sensitivity with rated power consumption of 700 mW  
for failsafe models and 500 mW for dual coil latching models  
• Models with TTL-driven dual coil latching and indicator  
terminals are available  
• Models available with 26.5 GHz or 18 GHz operation.  
• RoHS Compliant  
Ordering Information  
■
Model Number Legend:  
G9YA
@
–
@@
–
@@
–
@@@  
1
2 3
 
4 5
 
6 7
8
 
1. Relay
 
Function  
5. Characteristic
 
Impedance  
5: 50
 
Ω  
None: Failsafe  
K:  
T:  
Dual coil latching  
TTL-driven dual coil latching (with self cut-off function)  
6. Operating
 
Terminals  
None
:
S
oldering terminals  
2. Contact
 
Form  
12: SPDT  
P:  
C:  
Pin terminals (See note 1.)  
Connector cable  
3. Terminal
 
Shape  
7. Auxiliary
 
Indicator Terminals  
S:  
SMA  
None
:
N
o indicator terminals  
4. Frequency  
N:  
Indicator terminals  
4:  
3:  
26.5 GHz  
18 GHz  
8. Data
 
Package  
None
:
N
o data package  
D:  
Data package  
Note: 1.
 
T
o
o
rder, select the part number and add the desired coil voltage rating (e.g. G9
Y
A
K-12S-45-PND
DC12
).  
2.
Refer to “List of Models” for available part numbers  
Application Examples  
•
Mobile communications infrastructure equipment, mobile phone base station equipment, and antenna devices  
•
Wireless devices, wireless LAN, and disaster prevention wireless equipment  
•
T
e
st and measurement equipment  
•
Broadcasting equipment (digital T
V
,
c
able T
V
,
a
nd satellite broadcasting)  
Coaxial Switch
 
G9YA  
357  

DISCONTINUED  
■
List of Models  
Standard SPDT Models with Soldering Terminals  
Classification Indicator
 
terminals Data
 
package  
Rated coil voltage  
Minimum packaging unit  
Model  
G9
Y
A
-12S-45  
Failsafe  
No  
No  
4.5, 12, 15, 24, and 28 VDC
 
One per box  
4.5, 12, 15, 24, and 28 VDC  
Y
e
s  
No  
G9
Y
A
-12S-45-D  
G9
Y
A
-12S-45-N  
G9
Y
A
-12S-45-ND  
G9
Y
A
K-12S-45  
Y
e
s  
No  
4.5, 12, 15, 24, and 28 VDC  
Y
e
s  
No  
4.5, 12, 15, 24, and 28 VDC  
Dual coil  
latching  
4.5, 12, 15, 24, and 28 VDC
 
One per box  
4.5, 12, 15, 24, and 28 VDC  
Y
e
s  
No  
G9
Y
A
K-12S-45-D  
G9
Y
A
K-12S-45-N  
G9
Y
A
K-12S-45-ND  
G9
Y
AT
–
12S-45  
Y
e
s  
4.5, 12, 15, 24, and 28 VDC  
Y
e
s  
No  
4.5, 12, 15, 24, and 28 VDC  
TTL-driven dual
 
No  
coil latching  
5, 12, 15, and 24 VDC  
5, 12, 15, and 24 VDC  
5, 12, 15, and 24 VDC  
5, 12, 15, and 24 VDC  
One per box  
Y
e
s  
No  
G9
Y
AT
–
12S-45-D  
G9
Y
AT
–
12S-45-N  
G9
Y
AT
–
12S-45-ND  
(with self cut-off  
Y
e
s  
function)  
Y
e
s  
Standard SPDT Models with Pin Terminals  
Classification Indicator
 
terminals Data
 
package  
Rated coil voltage  
Minimum packaging unit  
Model  
Failsafe  
No  
No  
4.5, 12, 15, 24, and 28 VDC
 
One per box  
G9
Y
A
-12S-45-P  
Y
e
s  
No  
4.5, 12, 15, 24, and 28 VDC  
4.5, 12, 15, 24, and 28 VDC  
4.5, 12, 15, 24, and 28 VDC  
4.5, 12, 15, 24, and 28 VDC
 
One per box  
4.5, 12, 15, 24, and 28 VDC  
4.5, 12, 15, 24, and 28 VDC  
4.5, 12, 15, 24, and 28 VDC  
G9
Y
A
-12S-45-PD  
G9
Y
A
-12S-45-PN  
G9
Y
A
-12S-45-PND  
G9
Y
A
K-12S-45-P  
G9
Y
A
K-12S-45-PD  
G9
Y
A
K-12S-45-PN  
G9
Y
A
K-12S-45-PND  
G9
Y
AT
–
12S-45-P  
G9
Y
AT
–
12S-45-PD  
G9
Y
AT
–
12S-45-PN  
G9
Y
AT
–
12S-45-PND  
Y
e
s  
No  
Y
e
s  
No  
Dual coil  
latching  
Y
e
s  
No  
Y
e
s  
Y
e
s  
No  
TTL-driven dual
 
No  
coil latching  
5, 12, 15, and 24 VDC  
5, 12, 15, and 24 VDC  
5, 12, 15, and 24 VDC  
5, 12, 15, and 24 VDC  
One per box  
Y
e
s  
No  
(with self cut-off  
function)  
Y
e
s  
Y
e
s  
Standard SPDT Models with Connector Cables  
Classification Indicator
 
terminals Data
 
package  
Rated coil voltage  
Minimum packaging unit  
Model  
Failsafe  
No  
No  
4.5, 12, 15, 24, and 28 VDC
 
One per box  
4.5, 12, 15, 24, and 28 VDC  
G9
Y
A
-12S-45-C  
Y
e
s  
No  
G9
Y
A
-12S-45-CD  
G9
Y
A
-12S-45-CN  
G9
Y
A
-12S-45-CND  
G9
Y
A
K-12S-45-C  
G9
Y
A
K-12S-45-CD  
G9
Y
A
K-12S-45-CN  
G9
Y
A
K-12S-45-CND  
G9
Y
AT
–
12S-45-C  
G9
Y
AT
–
12S-45-CD  
G9
Y
AT
–
12S-45-CN  
G9
Y
AT
–
12S-45-CND  
Y
e
s  
No  
4.5, 12, 15, 24, and 28 VDC  
Y
e
s  
No  
4.5, 12, 15, 24, and 28 VDC  
Dual coil  
latching  
4.5, 12, 15, 24, and 28 VDC
 
One per box  
4.5, 12, 15, 24, and 28 VDC  
Y
e
s  
No  
Y
e
s  
4.5, 12, 15, 24, and 28 VDC  
Y
e
s  
No  
4.5, 12, 15, 24, and 28 VDC  
TTL-driven dual
 
No  
coil latching  
(with self cut-off  
5, 12, 15, and 24 VDC  
5, 12, 15, and 24 VDC  
5, 12, 15, and 24 VDC  
5, 12, 15, and 24 VDC  
One per box  
Y
e
s  
No  
Y
e
s  
function)  
Y
e
s  
Note:
Versions with 18-GHz operation are available. Replace “-45” with “-35” when ordering.  
— Example: Order G9
Y
A
-12S
-35
-PND DC12 instead of G9
Y
A
-12S
-45
-PND DC12.  
358  
Coaxial Switch
 
G9YA  

DISCONTINUED  
Specifications  
■
Indicator Ratings, SPDT Models  
Rating  
100 mA max. at 30 V  
Contact resistance  
1
Ω
max. (See note 2.)  
Note: 1.
 
The above values are initial values.  
2.
The contact resistance was measured with 10 mA at 1 VDC with a voltage drop method.  
■
High-frequency Characteristics  
Frequency  
1 GHz max.  
4 GHz max.  
8 GHz max.  
12.4 GHz max.  
18 GHz max.  
26.5 GHz max.  
Item  
Insertion loss  
Isolation  
0.2 dB max.  
80 dB min.  
1.15 max.  
0.3 dB max.  
0.4 dB max.  
65 dB min.  
1.35 max.  
0.5 dB max.  
0.8 dB max.  
1.7 max.  
85 dB min.  
1.1 max.  
70 dB min.  
1.25 max.  
60 dB min.  
V
.
S.W.R.  
1.5 max.  
Note: 1.
 
The above values are initial values.  
2.
Of the above values, the rated values are 18 GHz max. for the 18-GHz models and 26.5 GHz max. for the 26.5-GHz models.  
■
Coil / Input Ratings  
Note:
An extra 140 to 300 mW of power consumption is added to models with indicator terminals, due to the operating coil and voltage specifications.  
Failsafe Models (G9
Y
A
-12S-45(35))  
Rated voltage
 
Rated current
 
Coil resistance
 
Must operate voltage
 
Must release voltage
 
Maximum voltage
 
Power consumption  
(VDC)  
(mA)  
155.2  
(
W
)  
(V)  
(V)  
10% min. of  
rated voltage  
(V)  
(mW)  
4.5  
12  
15  
24  
28  
29  
80% max. of  
rated voltage  
150% of rated voltage
 
Approx. 700  
58.5  
46.7  
29.2  
25.0  
205  
321  
822  
1,118  
Note: 1.
 
The rated current and coil resistance are measured at a coil temperature of 23
°
C with a tolerance of
±
10%.  
2.
The operating characteristics are measured at a coil temperature of 23
°
C.  
3.
The maximum voltage is the highest voltage that can be imposed on the relay coil instantaneousl
y
.  
Dual Coil Latching Models (G9
Y
A
K-12S-45(35))  
Rated voltage
 
Rated current
 
Coil resistance
 
Must operate voltage
 
Must release voltage
 
Maximum voltage
 
Power consumption  
(VDC)  
(mA)  
109.8  
(
W
)  
(V)  
(V)  
(V)  
(mW)  
4.5  
12  
15  
24  
28  
41  
80% max. of  
rated voltage  
80% max. of  
rated voltage  
150% of  
rated voltage  
Approx. 500 mW  
41.7  
33.3  
20.8  
17.9  
288  
450  
1,152  
1,568  
Note: 1.
 
The rated current and coil resistance are measured at a coil temperature of 23
°
C with a tolerance of
±
10%.  
2.
The operating characteristics are measured at a coil temperature of 23
°
C.  
3.
The maximum voltage is the highest voltage that can be imposed on the relay coil instantaneousl
y
.  
TTL-driven Dual Coil Latching Models (G9
Y
AT
–
12S-45(35))  
Rated voltage  
(VDC)  
TTL logic level  
Electronic self cut-off  
Switching frequency  
ON  
OFF  
5 VDC  
2.4 to 5.5 V  
0 to 0.5 V  
Y
e
s  
180 operations per  
minute max.  
(ON time: OFF time = 1:1)  
12 VDC  
15 VDC  
24 VDC  
Coaxial Switch
 
G9YA  
359  

DISCONTINUED  
■
Characteristics  
Type  
Failsafe models  
Dual coil latching models  
G9
Y
A
K-12S-45(35)  
TTL-driven dual coil  
latching models  
Item  
Model  
G9
Y
A
-12S-45(35)  
100 m
Ω
max.  
G9
Y
AT
–
12S-45(35)  
Contact resistance (See note 3.)  
Operating (set) time  
Release (reset) time  
Minimum set/reset pulse time  
15 ms max.  
15 ms max.  
—  
100 ms  
Insulation resistance (See note 4.)  
1,000 M
Ω
min. (at 500 VDC)  
500 VAC, 50/60 Hz for 1 min  
500 VAC, 50/60 Hz for 1 min  
Dielectric  
strength  
Coil and contacts  
Coil and ground,  
contacts and ground  
Contacts of same  
polarity  
500 VAC, 50/60 Hz for 1 min  
Vibration  
Destruction  
Malfunction  
Destruction  
Malfunction  
Mechanical  
Electrical  
10 to 55 Hz, 5.0-mm double amplitude  
10 to 55 Hz, 3.0-mm double amplitude  
1,000 m/s

2  

resistance  
Shock  
resistance  
500 m/s

2  

Endurance  
5,000,000 operations min. (at 36,000 operations/hour)  
5,000,000 operations min. (3 GHz, 5 W, 50
Ω,
V
.
S.W.R. 1.2 max.) at a switching frequency of 1,800  
operations/hour  
Contact carry power  
Ambient operating temperature  
Ambient operating humidity  
Weight  
120 W (at 3 GHz, 50
Ω
,
V
.
S.W.R.
≤
1.15) with an ambient temperature of 40
°
C  
−
55 to 85
°
C (with no icing or condensation)  
5% to 85%  
Approx. 50 g  
Note: 1.
 
The above values are initial values.  
2.
Rated and characteristic (initial) values are for a standard temperature of 23
°
C and a humidity of 65% unless otherwise indicated.  
3.
The contact resistance was measured with 10 mA at 1 VDC with a voltage drop method.  
4.
The insulation resistance was measured with a 500-VDC megohmmeter applied to the same parts as those used for checking the dielec-  
tric strength.  
Engineering Data  
High-frequency Characteristics  
(Isolation)  
High-frequency Characteristics  
(Insertion Loss)  
High-frequency Characteristics  
(Return Loss, V.S.W.R.)  
(A
v
erage
v
al
u
e [initial
v
al
u
e])  
(A
v
erage
v
al
u
e [initial
v
al
u
e])  
(A
v
erage
v
al
u
e [initial
v
al
u
e])  
0
0
1.9  
0
Sample: G9YA-12S-45 12
V
DC  
Meas
u
ring de
v
ice:  
Agilent
N
et
w
ork Analyzer
8
722ES  
Sample: G9YA-12S-45 12
V
DC  
Meas
u
ring de
v
ice:  
Agilent
N
et
w
ork Analyzer
8
722ES  
1.
8
 
10  
0.2  
0.4  
0.6  
0.
8
 
1.0  
1.2  
20  
40  
60  
Ret
u
rn loss  
1.7  
1.6  
1.5  
1.4  
1.3  
1.2  
20  
30  
40  
50  
60  
70  
V
.S.
W
.R.  
8
0  
Sample: G9YA-12S-45 12
V
DC  
1.4  
1.1  
1
8
0  
Meas
u
ring de
v
ice:  
Agilent
N
et
w
ork Analyzer
8
722ES  
1.6  
100  
90  
0
0
4
8
12  
16  
20  
24  
2
8  
0
4
8
12  
16  
20  
24  
2
8  
4
8
12  
16  
20  
24  
2
8  
Fre
qu
ency (GHz)  
Fre
qu
ency (GHz)  
Fre
qu
ency (GHz)  
Note: 1.
 
The tests were conducted at an ambient temperature of 23
°
C.  
2.
The high-frequency characteristics will vary according to the connectors. Be sure to check operation including durability at the actual de-  
vice before use.  
360  
Coaxial Switch
 
G9YA  

DISCONTINUED  
Dimensions  
Note:
All units are in millimeters unless otherwise indicated.  
■
Models with Soldering Terminals  
G9
Y
A
-12S-45(35)-
@
 
G9
Y
A
K-12S-45(35)-
@  
G9
Y
AT
–
12S-45(35)-
@  
13.4  
4 4  
4
7
Solderin
g
terminals  
2
0.5  
4
39  
Two, 3.1 dia.  
Two, 2.4 dia.  
4.6 2.2  
7.3  
8.7  
11.2  
13.2  
Three SMA jack connectors  
22.4  
30.0  
34.0  
Note:
Each value has a tolerance of
±
0.3 mm.  
Soldering Terminal Arrangement  
Model  
G9
Y
A
-12S-45(35)-
@  
G9
Y
A
K-12S-45(35)-
@  
Dual coil latching  
G9
Y
AT
–
12S-45(35)-
@  
Indicator terminals  
Type  
Failsafe  
TTL-driven dual coil latching  
Without indicator terminals  
GND  
GND  
1
2
R
+
+
V
GND
Lo
g
ic 1 Lo
g
ic 2  
+
S
With indicator terminals  
NC COM NO  
1
COM  
2
1
COM  
2
GND  
1
+
2
GND  
R
+
V
GND
Lo
g
ic 1 Lo
g
ic 2  
+
S
Coaxial Switch
 
G9YA  
361  

DISCONTINUED  
■
Models with Pin Terminals  
G9
Y
A
-12S-45(35)-P
@  
G9
Y
A
K-12S-45(35)-P
@  
G9
Y
AT
–
12S-45(35)-P
@  
ABCD  
EFGH  
Pin No.  
2.54  
2.54  
2.54  
5.2  
Pin terminals  
2.54  
7.4  
39  
Two, 3.1 dia.  
Two, 2.4 dia.  
4.6 2.2  
7.3  
8.7  
Three SMA jack connectors  
11.2  
13.2  
22.4  
30.0  
34.0  
Note:
Each value has a tolerance of
±
0.3 mm.  
Pin Terminal Arrangement  
Indicator  
Coil  
Pin number  
A
B
C
D
E
V
F
G
H
Without indicator
 
Failsafe  
terminals  
GND  
GND  
GND  
GND  
GND  
GND  
+
Dual coil latching  
1
2
Logic 2  
+
TTL-driven dual coil latching  
Failsafe  
Logic 1  
With indicator  
terminals  
NC  
1
COM  
COM  
COM  
NO  
2
Dual coil latching  
1
2
TTL-driven dual coil latching  
1
2
V
Logic 1  
Logic 2  
362  
Coaxial Switch
 
G9YA  

DISCONTINUED  
■
Models with Connector Cables  
D-sub connector  
pin-contact type  
Pin No.  
G9
Y
A
-12S-45(35)-C
@  
G9
Y
A
K-12S-45(35)-C
@  
G9
Y
AT
–
12S-45(35)-C
@  
12.6  
Two, 3.05 dia.  
24.99  
30.8  
6
1.2  
Polyvinyl chloride wire  
10  
110  
39  
Two, 3.1 dia.  
Two, 2.4 dia.  
4.6 2.2  
7.3  
8.7  
Three SMA jack connectors  
11.2  
22.4  
30.0  
34.0  
13.2  
Note:
Each value has a tolerance  
of
±
0.3 mm.  
Pin Terminal Arrangement  
Indicator  
Coil  
Pin number  
A
B
C
D
E
F
V
G
H
+
I
Without  
Failsafe  
GND  
GND  
GND  
GND  
GND  
GND  
indicator  
terminals  
Dual coil latching  
TTL-driven dual coil latching  
1
2
Logic 1
 
Logic 2  
+
With indicator
 
Failsafe  
terminals  
NC  
1
COM  
COM  
COM  
NO  
2
Dual coil latching  
1
2
TTL-driven dual coil latching  
1
2
V
Logic 1
 
Logic 2  
Coaxial Switch
 
G9YA  
363  

DISCONTINUED  
Precautions  
■
Precautions for Correct Use  
Relay Handling  
Using Relays in an Atmosphere Containing  
•
Relays are precision components. Do not subject the Relay to  
vibration or shock in excess of the standard values, whether before  
or after mounting. The original performance cannot be maintained if  
the Relay is subjected to abnormal vibration or shock or dropped.  
Also, do not subject the Relay to vibration or shock in excess of the  
rated values when it is still packaged.  
Corrosive Gas (Silicon, Sulfuric, or Organic Gas)  
Do not use Relays in a location where silicon gas, sulfuric gas  
(SO

2

, H

2

S), or organic gas is present. If Relays are used for a long  
period in an atmosphere of sulfuric gas or organic gas, contact sur-  
faces may become corroded and cause contact instability and  
obstruction, and terminal soldering characteristics may be degraded.  
If Relays are stored or used for a long time in an atmosphere of sili-  
con gas, a silicon coating will be generated on contact surfaces,  
causing contact failure.  
•
Avoid subjecting the Relay to direct sunlight when it is being used,  
stored or transported. Keep the Relay at conditions of normal tem-  
perature, humidit
y
,
a
nd pressure.  
•
The Relay is not sealed. It cannot be washed.  
•
Be absolutely sure not to wire the Relay incorrectl
y
.
I
ncorrect wiring  
will result in failure of Relay functions and damage or fire in the  
Relay, in addition to affecting external circuits.  
•
Recommended torque for mounting the SMA connectors is the  
MIL-C-39012 standard of 0.90
±
0.1 N·m. The conditions, however,  
depend on the compatibility with the material of the connectors.  
•
Use of two or more Relays may result in change in the Relay char-  
acteristics due to interference in the magnetic fields generated by  
the Relays. Be sure to check operation using the actual devices  
before use.  
Connecting to Coil and Indicator Terminals  
I. Models with Soldering Terminals  
Perform manual soldering under the following conditions.  
Soldering iron tip temperature: 280 to 300
°
C  
Soldering time: Approx. 3 s max.  
II. Models with Pin Terminals  
Heed the following precautions when using models with pin terminals.  
•
Use a power supply for the coil operating power supply with a max-  
imum ripple of 5%. Be sure to check operation using the actual  
devices before use.  
•
Operation in excess of the coil ratings, contact ratings, switching  
service life or other specifications may result in abnormal heat gen-  
eration, smoke, or fire.  
1.
Connectors for use: Straight dip type for panels  
Male connectors: HKP-8M29 (Honda Tsushin Kogyo)  
Refer to the general catalog of Honda Tsushin Kogyo for connec-  
tor models and specifications.  
2.
The sockets do not have a lock mechanism. Pulling the lead  
wires, shock, or long-term vibration may cause the connectors to  
become disconnected. Heed the following precautions.  
Latching Relay Mounting  
•
Securely fix the Relay and connectors and make sure that no  
force is pulling on the lead wires during use.  
Make sure that the vibration or shock generated from other devices  
(e.g., Relays) on the same panel during operation or resetting do not  
exceed the values provided in the catalog, otherwise the latching  
Relay that has been set may be reset or vice versa. The latching  
Relay is reset before shipping. If excessive vibration or shock is  
imposed, however, the latching Relay may be set accidentall
y
.
B
e  
sure to apply a reset signal before use.  
•
Fully insert the socket into the Relay connector.  
3.
Do not solder the lead wires directly to the pin connectors.  
Long-term Continuously ON Contacts  
Using the Relay in a circuit where the Relay will be ON continuously  
for long periods (without switching) can lead to unstable contacts  
because the heat generated by the coil itself will deteriorate the insu-  
lation, causing a film to develop on the contact surfaces. We recom-  
mend using a latching Relay (magnetic-holding Relay) in this kind of  
circuit. If a failsafe Relay must be used in this kind of circuit, use a  
full-loop circuit design to provide protection against possible poor  
connections and coil disconnection.  
364  
Coaxial Switch
 
G9YA  

DISCONTINUED  
MEMO  
Coaxial Switch
 
G9YA  

DISCONTINUED  
All sales are subject to Omron Electronic Components LLC standard terms and conditions of sale, which  
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.  
To
c
onvert millimeters into inches, multiply by 0.03937.
T
o
c
onvert grams into ounces, multiply by 0.03527.  
OMRON ON-LINE  
OMRON ELECTRONIC  
COMPONENTS LLC  
55 E. Commerce Drive, Suite B  
Schaumburg, IL 60173  
847-882-2288  
12/10  
Specifications subject to change without notice  
Printed in USA  
Cat. No. X302-E-1  
Coaxial Switch
 
G9YA