Omron-Electronics-MY3F-AC24
| Part # | Omron-Electronics-MY3F-AC24 |
| Download | Omron-Electronics-MY3F-AC24 |
General-purpose Relay
MY
An Improved Miniature Power Relay with
Many Models for Sequence Control and
Power Applications
ꢀ A wide range of relay variations including ones with operation
indicators, built-in diodes, etc.
ꢀ Arc barrier standard on 3- and 4-pole Relays.
ꢀ Dielectric strength: 2,000 VAC.
LR
Ordering Information
List of Models
Type
Contact form
Plug-in socket/solder terminals
PCB terminals
Upper-mounting/
solder terminals
W
ith indicator
Standard
DPDT
MY2
MY2N
MY2-02
MY2F
MY2ZF
MY3F
MY4F
MY4ZF
–––
DPDT (bifurcated)
3PDT
MY2Z
MY2ZN
MY3N
MY2Z-02
MY3-02
MY4-02
MY4Z-02
–––
MY3
4PDT
MY4
MY4N
4PDT (bifurcated)
DPDT
MY4Z
MY4ZN
MY2N-D2
MY2ZN-D2
MY3N-D2
MY4N-D2
MY4ZN-D2
MY2N-CR
–––
W
ith built-in diode
MY2-D
MY2Z-D
MY3-D
MY4-D
MY4Z-D
MY2-CR
MY2Z-CR
MY3-CR
MY4-CR
MY4Z-CR
MY2I4
(DC only)
DPDT (bifurcated)
3PDT
–––
–––
–––
–––
4PDT
–––
–––
4PDT (bifurcated)
DPDT
–––
–––
With built-in CR
(AC only)
–––
Not available.
DPDT (bifurcated)
3PDT
–––
–––
–––
4PDT
MY4N-CR
–––
–––
4PDT (bifurcated)
DPDT
–––
W
ith test button
MY2I4N
MY4I4N
–––
–––
–––
4PDT
MY4I4
–––
Note:
1.
When ordering, add the rated coil voltage to the model number
. Rated coil voltages are given in the coil ratings table.
Example: MY2, 6 V
AC
Rated coil voltage
2.
The standard contacts for MY2Z-series Relays and for the MY4Z are gold-plated.
1
MY
MY
Accessories (Order Separately)
Sockets
Poles
Front-mounting
socket
Back-mounting socket
(DIN-rail/screw mounting)
Solder terminals
W/ clip
W/o clip
W
W/ clip
ire-wrap terminals
PCB
terminals
W/o clip
2
PYF08A
PYF08A-E (finger protection)
PYF08A-N (finger protection)
PY08
PY08-Y1
PY08QN
PY08QN-Y1
PY08–02
3
4
PYF1
1A
PY11
PY11-Y1
PY14-Y1
PY11QN
PY14QN
PY11QN-Y1
PY14QN-Y1
PY11-02
PY14-02
PYF14A
PYF14A-N (finger protection)
PYF14A-E (finger protection)
PY14
PY14-3*
Note:
*1
.
Equipped with operation check terminal.
2.
The PYF08A(-E), PYF1
1A, and PYF14A(-E) have been approved as individual sockets by UL S08 and CSA C22.2.
Mounting Plates for Sockets
Socket
model
For 1 socket
For 18 sockets
For 36 sockets
PY08, PY1
1, PY14, PY08QN(2),
PYP-1
PY11QN(2), PY14QN(2)
PYP-18
PYP-36
Note:
PYP-18 and PYP-36 can be cut into any desired length in accordance with the number of sockets.
Socket Hold-down Clip Pairing
Relay
type
Poles
Front-connecting
sockets
Back-connecting sockets
Solder/wire-wrap
terminals
(rail-/screw-mounted)
PCB
terminals
Socket Clip
Socket
Clip
Socket
PY08(QN)
Clip
PYC-P
Standard, bifurcated contacts, operation
indicator,
built-in diode.
2
PYF08A-N, PYC-A1
PYF08A-E,
PYF08A
PY08(QN)
PYC-P
PYC-P2
PYC-1
3
4
PYF11A
PY11(QN)
PY14(QN)
PY11(QN)
PY14(QN)
PYF14A-N,
PYF14A-E,
PYF14A
T
est button
2
PYF08A-N, PYC-A1
PYF08A-E,
PYF08A
PY08(QN)
PYC-P2
PYC-1
PY08(QN)
3
4
PYF11A
PY11(QN)
PY14(QN)
PY11(QN)
PY14(QN)
PYF14A-N,
PYF14A-E,
PYF14A
CR circuit
2
PYF08A-N, Y92H-3
PYF08A-E,
PYF08A
PY08(QN)
PY08(QN)
3
4
PYF11A
PY11(QN)
PY14(QN)
PY11(QN)
PY14(QN)
PYF14A-N,
PYF14A-E,
PYF14A
2
MY
MY
Specifications
Coil Ratings
Rated
voltage
Rated current
Inductance
Must
Must
Max.
Coil
Power
(reference value)
operate release voltage
% of rated voltage
resistance
consum.
(Approx.)
50 Hz
60 Hz
Arm.
OFF
Arm. ON
1.0 to
AC
6 V
12 V
24 V
50 V
214.1 mA
106.5 mA
53.8 mA
25.7 mA
183 mA
91 mA
46 mA
22 mA
12.2
ꢀ
0.04 H
0.17 H
0.69 H
3.22 H
14.54 H
19.20 H
54.75 H
83.50 H
0.17 H
0.73 H
3.20 H
10.60 H
45.60 H
0.08 H
0.33 H
1.30 H
5.66 H
24.6 H
32.1 H
94.07 H
136.40 H
0.33 H
1.37 H
5.72 H
21.00 H
86.20 H
80%
max.
30%
min.
110%
1.2 V
A
46
ꢀ
(60 Hz)
180
788
ꢀ
ꢀ
0.9 to
100/1
10 V
1
1.7/12.9 mA
10/1
1 mA
3,750
4,430
12,950
18,790
ꢀ
ꢀ
1.1 V
A
1
10/120 V
9.9/10.8 mA
8.4/9.2 mA
5.3/5.8 mA
4.2/4.6 mA
(60 Hz)
200/220 V
6.2/6.8 mA
220/240 V
4.8/5.3 mA
ꢀ
ꢀ
DC
6 V
150 mA
75 mA
40
ꢀ
10%
min.
0.9 W
12 V
24 V
48 V
160
650
ꢀ
ꢀ
36.9 mA
18.5 mA
2,600
ꢀ
100/1
10 V
9.1/10 mA
1
1,000
ꢀ
Note:
1. The
rated current and coil resistance are measured at a coil temperature of 23
and
ꢂ
15% for DC coil resistance.
ꢁ
C with tolerances
of +15%/–20% for rated currents
2.
Performance characteristic data are measured at a coil temperatures of 23
ꢁ
C.
3.
AC coil resistance and impedance are provided as reference values (at 60 Hz).
4. Power
consumption drop was measured for the above data. When
driving transistors, check leakage current and connect a bleeder
resistor
if required.
Contact Ratings
Item
Double- or three-pole
Four-pole
Resistive load
(cosf
= 1)
Inductive load
(cosf
=0.4,
L/R=7 ms)
Resistive load
(cosf
= 1)
Inductive load
(cosf
=0.4,
L/R=7 ms)
Rated load
5 A, 220 V
AC
5 A, 24 VDC
5 A
2 A, 220 V
AC
2 A, 24 VDC
3 A, 220 V
AC
3 A, 24 VDC
3 A
0.8 A, 220 V
1.5 A, 24 VDC
Carry
current
Max.
250 VAC
125 VDC
250 V
AC
125 VDC
switching
voltage
Max.
5 A
5 A
3 A
3 A
switching
current
Max.
1,100 VA
120 W
440 VA
48 W
660 VA
72 W
176 VA
36 W
switching
capacity
Min.
Standard type: 100 mA, 5 VDC
Bifurcated type: 100
A, 1 VDC
Standard type: 1
mA, 1 VDC
Bifurcated type: 100
ꢃ
A, 1 VDC
permissible
load*
ꢃ
*Note:
P level:
ꢄ
60
= 0.1 x 10
-6
/operation, reference value
3
MY
MY
Characteristics
Item
All
relays
Contact resistance
Operate time
50 m
ꢀ
max.
20 ms max.
Release time
20 ms max.
Max. operating frequency
Mechanical:
18,000 operations/hr
Electrical:
1,800 operations/hr (under rated load)
Insulation resistance
Dielectric strength
1,000 M
ꢀ
min. (at 500 VDC)
2,000 V
AC, 50/60 Hz for 1 min (1,000 V
AC
between contacts of same polarity)
V
ibration resistance
Destruction:
10 to 55 Hz, 1.0-mm double amplitude
Malfunction:
10 to 55 Hz, 1.0-mm double amplitude
2
Shock resistance
Destruction:
1,000 m/s
(approx. 100G)
2
Malfunction:
200 m/s
(approx. 20G)
Life expectancy
See following table.
Ambient operating temperature*
Single- and double-pole standard, bifurcated-contact, test-button, relays:
–55
ꢁ
C to 70
ꢁ
C (with no icing)
All other relays: –55
ꢁ
C to 60
ꢁ
C (with no icing)
Ambient operating humidity
Weight
35% to 85%
Approx. 85 g
Note:
The values given above are initial values.
Life Expectancy Characteristics
Relays
Mechanical
life
(at 18,000 operations/hr)
Electrical life
(at 1,800 operations/hr under rated load)
1-,2-,3-pole:
500,000 operations min.
Normal,
With test button (except relays
with operation
AC
50,000,000 operations min.
indicator), With CR
DC:
100,000,000 operations min.
4-pole:
200,000 operations min.
With operation indicator or built-in diode
AC
50,000,000 operations min.
DC:
100,000,000 operations min.
1-,2-,3-pole:
500,000 operations min.
4-pole:
200,000 operations min.
With bifurcated contacts
2-pole:
50,000,000 operations min.
2-pole:
200,000 operations min.
4-pole: 4-pole:
100,000 operations min.
Note:
See following tables for real load life expectancies.
Life Expectancies Under Real Loads
MY2
Rated
voltage
100 V
AC
Load type
AC motor
Conditions
Operating frequency
ON for 2 s, OFF for 30 s
Electrical life
100,000 operations
50 W
, 100 V
AC single-phase with
2.8-A inrush current, 0.4-A carry
current
50 W
, 100 V
AC single-phase with
ON for 1 s, OFF for 30 s
300,000 operations
4,000,000 operations
1.6-A inrush current, 1-A carry current
AC solenoid
24 W with 1-A carry current
ON for 1.5 s, OFF for 1.5 s
MY4
Rated voltage
Load type
Conditions
Operating frequency
Electrical life
100 V
AC
AC solenoid
50 V
A with 2-A inrush current, 0.7A
carry current
ON for 1 s, OFF for 3 s
25,000 operations
DC magnetic
switch
25 W with L/R = 40 ms , 0.2-A carry
current
AC magnetic
switch
DC solenoid
35 V
A with 1.5-A inrush current,
0.35-A carry current
40 W with L/R = 10 ms, 1.6-A carry
current
30 W with L/R = 10 ms with 0.34-A
carry current
500,000 operations
5,000,000 operations
6,000,000 operations
24 VDC
ON for 0.5 s, OFF for 1.5 s
ON for 0.5 s, OFF for 1.5 s
4
MY
MY
Approved by Standards
Some MY Relays are available in models meeting various safety
standards.
When ordering, you must specify
the desired standards.
Refer
to
Ordering Information
for specific models. Note that the rat
–
ing recognized by the various standards sometimes vary from the
ratings
of the individual relays.
UL 508 Recognitions (File No. 41515)
LR (No. 563KOB-204524)
No.
of poles
Coil ratings
Contact ratings
Model
No.
of
Coil
Contact ratings
poles
ratings
2
6 to 240 V
AC
5 A, 120 V
AC resistive load
6 to 125 VDC
5 A, 28 VDC resistive load
5 A, 240 V
AC inductive load
MY -LR
2
4
6 to 240
VAC
6 to 120
VDC
2 A, 30 VDC inductive
load
2 A, 200 V
AC inductive
load
3
4
5 A, 28 VDC resistive load
5 A, 240 V
AC inductive load
1.5 A, 30 VDC
inductive load
0.8 A, 200 V
AC
inductive load
1.5 A, 1
15 V
AC
inductive load
6 to 240 V
AC
3 A 28 VDC resistive load
6 to 125 VDC
3 A 120 V
AC inductive load
1.5 A, 240 V
AC inductive load
5 A, 240 V
AC inductive load
(between contacts of same
polarity)
5 A, 28 VDC resistive load
(between contacts of same
polarity)
0.2 A, 120 VDC
CSA 22.2 No. 0 and No.14 (File No. LR31928)
Model
No.
of
Coil
Contact ratings
poles
ratings
MY
2, 3
6 to 240
VAC
6 to 120
VDC
5 A, 28 VDC resistive
load
5 A, 240 V
AC inductive
load
4
3 A, 28VDC resistive
load
3 A, 240 V
AC inductive
load
5 A, 240 V
AC inductive
load (between contacts
of same polarity)
5 A, 28 VDC resistive
load (between contacts
of same polarity)
0.2 A, 120 VDC
Engineering Data
Maximum Switching Capacity
MY2, MY3
AC resistive load
AC inductive load
(cos
f
= 0.4)
DC resistive
load
DC inductive
load (L/R = 7 ms)
Switching
voltage (V)
5
MY
MY
MY4, MY4Z
AC resistive
load
AC inductive load
(cos
f
= 0.4)
DC resis-
tive load
DC Inductive
load
L/R = 7 ms
Switching
voltage (V)
Life Expectancy
MY2, MY3 (Resistive
Loads)
MY2, MY3 (Inductive Loads)
5,000
5,000
110 VAC resistive load
110 VAC inductive
load (cos
f
= 0.4)
220 VAC
resistive load
1,000
500
1,000
500
220 VAC in-
ductive load
(cos
f
= 0.4)
24 VDC inductive load
(L/R = 7 ms)
24 VDC resistive
load
100
100
Switching current (A)
Switching current (A)
MY4 (Inductive Loads)
MY4 (Resistive Loads)
5,000
5,000
110 VAC resistive
load
220 VAC resis-
tive load
110 VAC Inductive
load
1,000
500
1,000
500
30 VDC resistive
load
220 VAC Inductive
load
30 VDC Inductive
load
100
100
Switching current (A)
Switching current (A)
MY4Z (Resistive Loads)
MY4Z (Inductive Loads)
5,000
5,000
1,000
1,000
110 VAC (cos
f
= 0.4)
220 VAC resis-
tive load
500
100
500
100
24 VDC
L/R = 7 ms
24 VDC resistive load
220 VAC (cos
f
= 0.4)
Switching current (A)
6
MY
MY
Dimensions
Note:
All
units are in millimeters unless otherwise indicated.
Relays with Solder Terminals
MY2, MY2N, MY2N-D2
MY2N
DC
type
AC type
2.6
Standard
Eight, 1.2 dia. x 2.2 ellipse holes
0.5
28 max.
6.3
21.5
max.
0.5
36
max.
6.4
Note:
1. AC type is equipped with a coil disconnection
self–diagnostic
function.
2.
Pay due attention as DC type has polarity
.
MY2N-D2
MY3, MY3N, MY3N-D2,
MY3N
2.6
DC
type
AC type
Standard
Eleven, 1.2 dia. x 2.2
ellipse holes
28 max
6.3
0.5
36
max.
21.5
max.
6.4
Note:
1. AC
type is equipped with a coil disconnection self–
diagnostic
function.
2.
Do not reverse the polarity of DC relays.
MY3N-D2
7
MY
MY
MY4
2.6
Fourteen, 1.2 dia. x 2.2
ellipse holes.
0.5
28 max.
6.3
0.5
21.5
max.
36
6.4
max.
Terminal arrangement/internal connections
(bottom view)
MY4N
MY4N-D2
DC
type
AC type
Standard
Note:
1. AC
type is equipped with a coil disconnection self-
diagnostic function.
2.
Do not reverse the polarity of DC relays.
MY I4
Note:
1. Mount
the relay with a socket.
2. T
est button
I4:
AC with red push button
DC with blue push button
Note:
The terminal arrangement and internal connections of the above relays are as same as these of MY
relays.
8
MY
MY
MY (N)-CR,
MY (Z)-CR
MY (N)-C
R
MY (Z)-C
R
2.6
Fourteen, 1.2 dia. x 2.2 ellipse holes
0.5
CR
CR
28 max.
6.3
0.5
21.5
max.
53
max.
6.4
Relays with PCB Terminals
MY -02
PC Board Mounting Holes
MY4-02 (4PDT)
3.5
1
DPDT
3PDT
13.2
4PDT
13.2
13.2
3.3 (2.6)
4.4
4.3
4.1
12.65
0.5
28 max.
6.35
6.3
6.3
Fourteen,
1.3
ꢂ
0.1
holes
Eleven,
Eight,
21.5
3.75
1.3
ꢂ
0.1
0.5
36 max.
1.3
ꢂ
0.1
max.
holes
holes
4
Note:
The tolerance is
ꢂ
0.1.
Note:
1. The
figures in the parentheses are for MY4-02.
2. The
above dimensions also apply to the DPDT and
3PDT Relays.
3. The
internal connections of the above Relays are as
same as these of MY
@
Relays.
9
MY
MY
Upper-mounting Relays
MY F
Mounting holes
MY4F
2.6
Two 3.5 dia holes or M3 holes
Fourteen, 1.2 dia. x 2.2
ellipse holes
4.35
2
38
29 max.
38
0.5
44 max.
6.4
0.5
36
max
.
3.5
22.5 max.
Note:
1. The above dimensions also apply to the
DPD
T
,
and 3PDT relays.
2. The
internal connections of
the above relays are as
same
as these of MY
relays.
Mounting Height with Socket
DIN Track/Surface-mounting Socket
Back-mounting Socket
MY
70 (87)
66 (83)
MY
39 (56)
PYF A(-E)
PY
@
Note:
1. The
PTF-A can be rail–mounted or screw-mounted.
2. For
the MY
-CR (CR circuit built-in type) model, figure
in
the parentheses apply
.
3.
PYC-P hold down clip should be used with PYF08M.
10
MY
MY
Sockets
PYF08A-E
PYF08A-N
PYF08A
PY08
PY08-Y1
PY08QN
PY08-02
PYF14A-E
PYF14A-N
PY14
PY11
PY14-Y1
PY14QN(2)
PY11QN(2)-Y1
PY14QN(2)-Y1
PY14-02
PYF11A
PY11QN(2)
PY11-02
9
MY
MY
Mounting Plates for Sockets
PYP-1
PYP-18
PYP-36
492
17 x 27.4 = 465.8
ꢂ
0.6
13.1
492
+0.2
0
R1.7
21.4
4.5
3.4
72 wide el-
lipse hole
17 x 27.4 = 465.8
ꢂ
0.6
13.1
4.5
3.4
Two, 3.4 dia. holes
39.7
ꢂ
0.2
86.4
Square
hole
42
ꢂ
0.1
42
ꢂ
0.1
49
49
39.7
ꢂ
0.2
+0.2
0
28
t = 1.6
21.4
13.1
17 x 27.4 = 465.8
ꢂ
0.6
21.6
t = 1.6
t = 1.6
Hold-down Clips
Hold-down
clips are used to hold relays to sockets and prevent them from coming loose due to vibration or shock.
Connection to socket
Connection to
mounting plate
For relays with test
buttons
For relays with CR circuits
PYC-A1
PYC-P
PYC-S
PYC–P2
Y92H-3
PYC-1
PY14-3 (for 4PDT)
Mounting holes
with operation check terminal
9(7.7)
2
81
+0.3
78
56
28
38.5
0.3
3
34.5+0.4
Operation check terminal
Operation checklamp can be built-in.
Short-circuit lead wire
Three, 1.2 dia holes Two dia. holes
Safety Standards for Sockets
Item
Standards
UL508
CSA22.2
File No.
E87929
LR31928
PYF08A (-E), PYF1
1A
PYF14A (-E)
12
MY
MY
Precautions
Connections
Do not reverse polarity when connecting DC-operated relays with
built-in
diodes or indicators DC-operated relays.
Mounting
t
t
Whenever possible, mount relays so that it is not subject to
vibration or shock in the same direction as that of contact
movement.
The test button should be be pointed upwards when mounting
(refer
to the right figure).
T
est button
13
Singapore Office:
Australia Offices:
India Offices:
OMRON ELECTRONICS PTE. LTD.
438A Alexandra Road, #05-05/08
(Lobby 2) Alexandra Technopark
Singapore 119967
Sydney Office:
Bangalore Office:
OMRON ELECTRONICS PTY. LTD.
Omron House
71 Epping Road, North Ryde
Sydney, New South Wales 2113
Australia
Tel: (61-2)
9878 6377
Fax: (61-2) 9878 6981
Toll Free: 1800 678838
E-mail: au_enquiry@ap.omron.com
OMRON AUTOMATION PVT. LTD.
No. 43, G.N. Complex
St.Johns Road
Bangalore – 560 042
India
Tel: (91-80)
4072 6400/401
Fax: (91-80) 4146 6403
E-mail: in_enquiry@ap.omron.com
Tel: (65)
6547 6789
Fax: (65) 6547 6769
E-mail: mktg_sg@ap.omron.com
Malaysia Office:
OMRON ELECTRONICS SDN. BHD.
1101 Level 11 Uptown 1
1 Jalan SS21/58 Damansara Uptown
47400 Petaling Jaya, Selangor
Malaysia
Noida Office:
OMRON AUTOMATION PVT. LTD.
212 & 213, 2nd Floor
Melbourne Office:
OMRON ELECTRONICS PTY. LTD.
Axxess Corporate Park
Unit 98, 45 Gilby Road
Mt Waverley Victoria 3149
Australia
International Home Deco Park (IHDP)
Plot No.7, Sector 127, Taj Express Way
Noida 201301
Tel: (60-3)
7688 2888
Fax: (60-3) 7688 2833
India
E-mail: my_enquiry@ap.omron.com
Tel: (61-3)
8588 2600
Fax: (61-3) 8588 2690
E-mail: au_enquiry@ap.omron.com
Tel: (91-120) 4745 800
Fax:(91-120) 4745 801
Thailand Office:
E-mail: newdelhi_enquiry@ap.omron.com
OMRON ELECTRONICS CO. LTD.
Rasa Tower 20th Floor
555 Phaholyothin Road
Chatuchak, Bangkok
Brisbane Office:
Mumbai Office:
OMRON ELECTRONICS PTY. LTD.
Unit 14, 1378 Lytton Road
Hemmant 4174, Queensland
Australia
OMRON AUTOMATION PVT. LTD.
102 & 103, Meadows, Sahar Plaza,
Andheri-Kurla Road, Andheri East
Mumbai – 400 059
10900, Thailand
Tel: (66-2)
937 0500
Fax: (66-2) 937 0501
CRM Call Centre: (66-2) 942 6700
E-mail: th_enquiry@ap.omron.com
Tel: (61-7)
3859 3900
India
Fax: (61-7) 3348 8701
Tel: (91-22)
4275 5600
Fax: (91-22) 4275 5602
E-mail: mumbai_enquiry@ap.omron.com
E-mail: au_enquiry@ap.omron.com
Adelaide Office:
Indonesia Office:
OMRON ELECTRONICS PTY. LTD.
Suite 12, 18 Humpheries Terrace
Kilkenny, SA 5009
PT. OMRON ELECTRONICS
Graha Pratama Building, 3A Floor
Jl. M.T. Haryono Kav 15
Jakarta Selatan 12810
Indonesia
Vietnam Offices:
OMRON ASIA PACIFIC PTE. LTD.
HANOI REPRESENTATIVE OFFICE
6th Floor, 92 Hoang Ngan Street
Trung Hoa, Cau Giay
Australia
Tel: (61-8)
8440 6412
Fax: (61-8) 8345 1204
E-mail: au_enquiry@ap.omron.com
Tel: (62-21)
8370 9555
Fax: (62-21) 8370 9550
E-mail: id_enquiry@ap.omron.com
Hanoi, SR Vietnam
Tel: (84-4)
3556 3444
Fax: (84-4) 3556 3443
New Zealand Office:
E-mail: hn_enquiry@ap.omron.com
OMRON ELECTRONICS LTD.
65 Boston Road, Mt Eden
Private Bag 92620
Philippines Office:
HO CHI MINH REPRESENTATIVE OFFICE
99 Nguyen Thi Minh Khai Street
District 1, Ho Chi Minh City
SR Vietnam
OMRON ASIA PACIFIC PTE. LTD.
MANILA REPRESENTATIVE OFFICE
2nd Floor, Kings Court II Building
2129 Do Chino Roces Avenue
Corner Dela Rosa Street
Symonds Street, Auckland
New Zealand
Tel: (64-9)
358 4400
Tel: (84-8)
3839 6666
Fax: (64-9) 358 4411
Fax: (84-8) 3830 1279
E-mail: hcm_enquiry@ap.omron.com
1231 Makati City, Metro Manila
Philippines
E-mail: nz_enquiry@ap.omron.com
Tel: (63-2)
811 2831
Fax: (63-2) 811 2583
E-mail: ph_enquiry@ap.omron.com
Asia Pacific Head Office:
Authorized Distributor
OMRON ASIA PACIFIC PTE. LTD.
438A Alexandra Road
#05-05/08
(Lobby 2) Alexandra Technopark
Singapore 119967
Tel: (65) 6835 3011
Fax: (65) 6835 2711
E-mail: ask@ap.omron.com
Cat. No. J01P-E-01
Singapore
0410
In the interest of product improvement, specifications are subject to change without notice.