PANASONIC-ADW1203HLW
| Part # | PANASONIC-ADW1203HLW |
| Download | PANASONIC-ADW1203HLW |
Automation Controls Catalog
1 Form A 8A/16A,
Small Polarized Power
Relays (latching type)
DW RELAYS (ADW1)
Protective construction
:
Flux-resistant type
FEATURES
TYPICAL APPLICATIONS
10
1.
Low profile type available
(h = 15.8 mm
.622 inch
)
2.
Inrush type available
(TV-8 UL/C-UL approved)
3. IEC60335-1* compliant type
available
1. Lighting control equipment
2. Smart meters
24
15.8
3. Industrial equipment
4. Security equipment
5. Home appliances
Low profile type
(
Inrush type
)
10
10
6. Various power supplies
24
24
(PTI 325V VDE approved)
4.
Reflow possible (pin-in-paste)
5.
Certified by UL/C-UL, VDE
18.8
18.8
Reflow compatible type
IEC60335-1 compliant type
* Common safety standard for major electrical
appliance
(
Standard type
)
(
Standard & Inrush type
)
(
Unit
:
mm
)
ORDERING INFORMATION
ADW 1
W
Contact arrangement
Operating function
Nominal coil voltag
e
(
DC
)
Contact capacity
Type classification
Nil
:
Reflow compatible type
L
:
Low profile type
1
:
1 Form A
1
:
1 coil latching
2
:
2 coil latching
03
:
3
V
,
0
5
:
5
V
,
0
6
:
6V
Nil
:
Standard typ
e
(
8A
)
09
:
9
V
,
1
2
:
12
V
,
2
4
:
24V H
:
Inrush type
(
16A, Inrush current 100A
)
T
:
IEC60335-1 compliant type
Notes
:
1
“
. L
”
an
d
“
T
”
type are non-compliant reflow soldering.
2.Low profile type is availabl
e
(
inrush type only
)
.
3.The suffi
x
“
W
”
on the part number is only displayed on the inner and outer packaging.
It is not displayed on the relay.
industrial.panasonic.com/ac/e/
© Panasonic Corporation 2019
ASCTB8E 201903
2019.03
1
DW (ADW1)
TYPES
1. Standard type (8A) (Reflow compatible type)
Part No.
Contact arrangement
Nominal coil voltage
1 coil latching type
ADW1103W
ADW1105W
ADW1106W
ADW1109W
ADW1112W
ADW1124W
2 coil latching type
ADW1203W
ADW1205W
ADW1206W
ADW1209W
ADW1212W
ADW1224W
3V DC
5V DC
6V DC
9V DC
12V DC
24V DC
1 Form A
Standard packing: Carton: 100 pcs.; Case: 500 pcs.
Note: Carton packing is standard. Tube packing type is also available. Please consult us for details.
2. Standard type (8A) (IEC60335-1 compliant type)
Part No.
Contact arrangement
Nominal coil voltage
1 coil latching type
ADW1103TW
ADW1105TW
ADW1106TW
ADW1109TW
ADW1112TW
ADW1124TW
2 coil latching type
ADW1203TW
ADW1205TW
ADW1206TW
ADW1209TW
ADW1212TW
ADW1224TW
3V DC
5V DC
6V DC
9V DC
12V DC
24V DC
1 Form A
Standard packing: Carton: 100 pcs.; Case: 500 pcs.
Note: Carton packing is standard. Tube packing type is also available. Please consult us for details.
3. Inrush type (16A, Inrush current 100A
IEC60335-1 compliant type)*
1,
*
2
·
Part No.
Contact arrangement
Nominal coil voltage
1 coil latching type
ADW1103HTW
ADW1105HTW
ADW1106HTW
ADW1109HTW
ADW1112HTW
ADW1124HTW
2 coil latching type
ADW1203HTW
ADW1205HTW
ADW1206HTW
ADW1209HTW
ADW1212HTW
ADW1224HTW
3V DC
5V DC
6V DC
9V DC
12V DC
24V DC
1 Form A
Standard packing: 100 pcs.; Case: 500 pcs.
Notes: *1. Carton packing is standard. Tube packing type is also available. Please contact us for details.
*2. Please contact us for the reflow compatible type of inrush type (16A, Inrush current 100A · IEC60335-1 compliant type).
4. Inrush type (16A, Inrush current 100A
Low profile type)
·
Part No.
Contact arrangement
Nominal coil voltage
1 coil latching type
ADW1103HLW
ADW1105HLW
ADW1106HLW
ADW1109HLW
ADW1112HLW
ADW1124HLW
2 coil latching type
ADW1203HLW
ADW1205HLW
ADW1206HLW
ADW1209HLW
ADW1212HLW
ADW1224HLW
3V DC
5V DC
6V DC
9V DC
12V DC
24V DC
1 Form A
Standard packing: 100 pcs.; Case: 500 pcs.
Panasonic Corporation Electromechanical Control Business Division
industrial.panasonic.com/ac/e/
© Panasonic Corporation 2019
ASCTB8E 201903
2
DW (ADW1)
RATING
1.Coil data
• Operating characteristics such as ‘Operate voltage’ and ‘Release voltage’ are influenced by mounting conditions, ambient temperature, etc.
Therefore, please use the relay within ± 5% of rated coil voltage.
• ‘Initial’ means the condition of products at the time of delivery.
1) 1 coil latching type
Nominal operating
current
[±10%] (at 20°C
68°F
)
Nominal coil
voltage
Set voltage
(at 20°C
68°F
)
Reset voltage
(at 20°C
68°F
)
Coil resistance
[±10%] (at 20°C
68°F
)
Nominal operating
Max. applied voltage
(at 20°C
68°F
)
power
3V DC
5V DC
6V DC
9V DC
12V DC
24V DC
66.7mA
40.0mA
33.3mA
22.2mA
16.7mA
8.3mA
45
Ω
125
Ω
*80%V or less of
nominal voltage
(Initial)
*80%V or less of
nominal voltage
(Initial)
180
Ω
110%V of nominal
200mW
voltage
405
Ω
720
Ω
2,880Ω
2) 2 coil latching type
Nominal operating
current
[±10%] (at 20°C
68°F
)
Coil resistance
[±10%] (at 20°C
68°F
)
Nominal operating
Nominal coil
voltage
Set voltage
(at 20°C
68°F
)
Reset voltage
(at 20°C
68°F
)
Max. applied voltage
(at 20°C
68°F
)
power
Set coil
133.3mA
80.0mA
66.7mA
44.4mA
33.3mA
16.7mA
Reset coil
133.3mA
80.0mA
66.7mA
44.4mA
33.3mA
16.7mA
Set coil
22.5
Ω
62.5
Ω
Reset coil
22.5
Ω
Set coil
Reset coil
3V DC
5V DC
6V DC
9V DC
12V DC
24V DC
62.5
Ω
*80%V or less of
nominal voltage
(Initial)
*80%V or less of
nominal voltage
(Initial)
90
Ω
90
Ω
110%V of nominal
400mW
400mW
voltage
202.5
Ω
202.5
Ω
360
Ω
Ω
360
Ω
Ω
1,440
1,440
*Square, pulse drive
2. Specifications
Specifications
Characteristics
Item
Standard type
Inrush type
Arrangement
1 Form A
Contact
Rating
Contact resistance (Initial)
Max. 100 m
Ω
(By voltage drop 6 V DC 1A)
AgSnO type
Contact material
2
Nominal switching capacity (resistive load)
Max. switching power (resistive load)
Max. switching voltage
8A 250V AC
2,000VA
250V AC
8A AC
16A 277V AC
4,432VA
277V AC
16A AC
Max. switching current
Nominal operating power
200mW (1 coil latching type), 400mW (2 coil latching type)
Min. switching capacity (Reference value)*
1
100mA 5 V DC
Insulation resistance (Initial)
Min. 1,000MΩ (at 500V DC, Measurement at same location as “Breakdown voltage” section)
1,000 Vrms for 1min. (Detection current: 10mA)
Between open contacts
Between contact and coil
Breakdown voltage
(Initial)
5,000 Vrms for 1min. (Detection current: 10mA)
Electrical
characteristics
Surge breakdown voltage*
2
(Between contact and coil)
12,000 V (Initial)
Set time (at 20°C
68°F
) (Initial)
Reset time (at 20°C
68°F
) (Initial)
Max. 15 ms (Nominal voltage applied to the coil, excluding contact bounce time)
Max. 15 ms (Nominal voltage applied to the coil, excluding contact bounce time)
100 m/s
2
(Half-wave pulse of sine wave: 11 ms; detection time: 10µs)
1,000 m/s
2
(Half-wave pulse of sine wave: 6 ms)
Functional
Shock resistance
Destructive
Mechanical
characteristics
Functional
Vibration resistance
Destructive
10 to 55 Hz at double amplitude of 2 mm (Detection time: 10µs)
10 to 55 Hz at double amplitude of 3 mm
Mechanical
Min. 10
6
(at 180 times/min.)
Min. 5 × 10
4
(at 8A 250V AC, at 20 times/min.)
Min. 10
5
(at 5A 250V AC, at 20 times/min.)
(IEC60335-1 type only)
Min. 2 × 10
4
(at 16A 277V AC, ON:OFF = 1s:5s)
Min. 5 × 10
4
(at 8A 250V AC, at 20 times/min.)
Resistive load
Electrical
Expected life
Min. 2.5 × 10
4
[Inrush 100A 600W (120V AC)
Tungsten]
Inrush current
—
Cycle rate ON:OFF = 1s:59s
T
e
mperature: –40°C to +85°C
–40°F to +185°F
(8A or less),
T
e
mperature: –40°C to +85°C
–40°F to +185°F
Humidity: 5 to 85% R.H. (Not freezing and
condensing at low temperature)
Conditions for operation, transport and
–40°C to +70°C
–40°F to +158°F
(Over 8A to 16A)
Humidity: 5 to 85% R.H. (Not freezing and
condensing at low temperature)
Conditions
storage*
3
*
4
Unit weight
Approx. 8 g
.28 oz
(Low profile type: Approx. 7.5 g
.26 oz
)
Notes:
*1. Minimum switching load is a guide to the lower current limit of switching under the micro-load. This parameter is changed by the condition, such as switching times,
environment condition, and expected reliability. Therefore, Panasonic Corporation cannot assure the reliability. When the relay is used lower than minimum
switching load, reliability is attrition. Please use the relay over minimum switching load.
*2. Wave is standard shock voltage of ±1.2×50μs according to JEC-212-1981
*3. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage
conditions in NOTES.
*4. Allowable range when in original packaging is –40°C to +70
°C
–40°F to +158°
F
.
Panasonic Corporation Electromechanical Control Business Division
industrial.panasonic.com/ac/e/
© Panasonic Corporation 2019
ASCTB8E 201903
3
DW (ADW1)
REFERENCE DATA
■ Standard type and Inrush type
■ Standard type
1. Set time (1 coil latching type)
1. Max. switching capacity (AC resistive load)
2. Reset time (1 coil latching type)
Tested sample
:
ADW1106, 15 pcs.
Ambient temperature
:
28
℃
Contact load
:
5V DC, 10mA
Tested sample
:
ADW1106, 15 pcs.
Ambient temperature
:
28
℃
Contact load
:
5V DC, 10mA
100
7.0
6.0
5.0
4.0
3.0
2.0
7.0
6.0
5.0
4.0
3.0
2.0
Inrush type
16
10
8
Max.
Min.
Max.
Min.
Standard type
1.0
0
1.0
0
1
1
10
100 250
Contact voltag
e
(
V
)
1,000
70
80
90
100
110
120
130
70
80
90
100
110
120
130
Coil applied voltag
e
(
%V
)
Coil applied voltag
e
(
%V
)
■ Inrush type
1. Set time (1 coil latching type)
3.Ambient temperature characteristics
2. Reset time (1 coil latching type)
Tested sample
:
ADW1105HL, 6 pcs.
Ambient temperature
:-
40 to
+
85
℃
Tested sample
:
ADW1112HL, 30 pcs.
Ambient temperature
:
28
℃
Contact load
:
5V DC, 10mA
Tested sample
:
ADW1112HL, 30 pcs.
Ambient temperature
:
28
℃
Contact load
:
5V DC, 10mA
7.0
7.0
30
20
6.0
6.0
Release
voltage
Ave.
Ave.
5.0
4.0
3.0
2.0
5.0
4.0
3.0
2.0
10
Operate voltage
ー
60
ー
40
ー
20
0
20 40
60 80
100
Max.
Min.
Ambient
Max.
Min.
temperatur
(
e
℃
)
ー
10
ー
20
ー
30
1.0
0
1.0
0
70 80
90 100
110 120 130 140 150 160
70 80
90 100
110 120 130 140 150 160
Coil applied voltag
e
(
%V
)
Coil applied voltag
e
(
%V
)
3. Set time (2 coil latching type)
4. Reset time (2 coil latching type)
5. Reset time (2 coil latching type)
Tested sample
:
ADW1212HL, 30 pcs.
Ambient temperature
:
28
℃
Contact load
:
5V DC, 10mA
Tested sample
:
ADW1212HL, 30 pcs.
Ambient temperature
:
28
℃
Contact load
:
5V DC, 10mA
Tested sample
:
ADW1105HL, 6 pcs.
Ambient temperature
:-
40 to
+
85
℃
7.0
7.0
6.0
5.0
4.0
3.0
30
20
6.0
Release
voltage
Ave.
Ave.
5.0
4.0
3.0
2.0
10
Operate voltage
ー
60
ー
40
ー
20
0
20 40
60 80
100
Ambient
temperatur
(
e
℃
)
Max.
Min.
ー
10
Max.
Min.
2.0
1.0
ー
20
ー
30
1.0
0
0
70 80 90
100 110 120 130 140 150 160
70 80 90
100 110 120 130 140 150 160
Coil applied voltag
e
(
%V
)
Coil applied voltag
e
(
%V
)
Panasonic Corporation Electromechanical Control Business Division
industrial.panasonic.com/ac/e/
© Panasonic Corporation 2019
ASCTB8E 201903
4
DW (ADW1)
(mm)
CAD
The CAD data of the products with a “CAD” mark can be downloaded from our Website.
DIMENSIONS
1. Standard height type
CAD
PC board pattern (Bottom view)
External dimensions
17.5
3.5
24
4 o
r
5
ー
1.2dia.
2 coil latching
type only
Tolerance
±
0.1
Schematic (Bottom view)
1 coil latching type
2 coil latching type
2 coil latching
type only
ー
1
3
ー
1
3
+7
0.2
0.27
0.4dia.
1.5
0.8
0.8
+
6
5
ー
6
5
7.5
17.5
3.5
General tolerance
±
0.3
(Reset condition)
(Reset condition)
2. Low profile type
PC board pattern (Bottom view)
External dimensions
CAD
17.5
3.5
24
4 o
r
5
ー
1.2dia.
2 coil latching
type only
Tolerance
±
0.1
Schematic (Bottom view)
1 coil latching type
2 coil latching type
2 coil latching
type only
ー
1
3
ー
1
3
0.4dia.
1.5
0.8
0.2
0.27
+7
0.8
17.5
3.5
7.5
+
6
5
ー
6
5
General tolerance
±
0.3
(Reset condition)
(Reset condition)
SAFETY STANDARDS
UL/C-UL (Recognized)
VDE (Recognized)
Contact rating
TV rating (UL/C-UL)
File No.
Contact rating
Item
File No.
Contact rating
File No.
Standard type
E43149 8A
250V AC R 85°C
185°F
5×10
4
40032254
8A 250V AC (cosφ =1.0) 85°C
185°F
5×10
4
—
—
(8A)
5A 30V DC R 85°C
185°F
5×10
4
5A 30V DC (0ms) 85°C
185°F
5×10
4
E43149 16A
277V AC R 60°C
140°F
5×10
4
8A 250V AC R 85°C
185°F
5×10
4
5A 30V DC R 85°C
185°F
5×10
4
40032254
16A 277V AC (cosφ =1.0) 70°C
158°F
5×10
4
E43149
TV-8 rating 240V AC
8A 250V AC (cosφ =1.0) 85°C
185°F
5×10
4
40°C
104°F
2.5×10
4
5A 30V DC (0ms) 85°C
185°F
5×10
4
1200W Standard ballast 277V AC 50°C
122°F
6×10
3
Inrush type
(16A)
1200W Tungsten, 240V AC 50°C
122°F
6×10
3
600W Tungsten, 120V AC 50°C
122°F
2.5×10
4
5A 347V AC R 85°C
185°F
(UL standards only)
5×10
4
Notes: 1. CSA standards: Certified by C-UL
2. CQC standard: Application pending, Please contact us.
Panasonic Corporation Electromechanical Control Business Division
industrial.panasonic.com/ac/e/
© Panasonic Corporation 2019
ASCTB8E 201903
5
DW (ADW1)
NOTES
1. For cautions for use, please read
“GENERAL APPLICATION
GUIDELINES”.
3.
Max. applied voltage
It is not allowed to apply the
continuous maximum voltage to the
coil.
In order to obtain the specified
performance, please apply nominal
coil voltage.
2. Solder and cleaning conditions
1) Flow solder mounting conditions
Please obey the following conditions
when soldering automatically.
(1) Preheating: within 120°C
248°F
(solder surface terminal portion)
and within 120 seconds
4. Set/reset pulse time of latching type relay
Regarding the set/reset pulse time of
the latching type relay, it is
(2) Soldering iron: 260°C±5°C
500°F±41°F
(solder
recommended to apply nominal coil
voltage for minimum 30ms pulse
across the coil to secure the sure
operation considering the ambient
temperature and condition change
through service life.
temperature) and within 6
seconds (soldering time)
*Furthermore, because the type
of PC board used and other
factors may influence the
relays, test that the relays
function properly on the actual
PC board on which they are
mounted.
2) Reflow solder mounting (Pin-in-
Paste mounting) conditions
3) Since this is not a sealed type relay,
4
t
3
T
t
1
=60 to 120 seconds
t
2
=within 20 seconds
t
3
=within 30 seconds
t
4
=within 10 seconds
(
245
~
250
℃)
T
1
=150 to 180
℃
2
T
1
T
T
2
=230
℃
1
2
3
t
t
t
T
3
=250
℃
•
Cautions to observe when
mounting temperature increases in
the relay are greatly dependent on
the way different parts are located
a PC board and the heating
method of the reflow device.
Therefore, please conduct testing
on the actual device beforehand
after making sure the parts
soldered on the relay terminals
and the top of the relay case are
within the temperature conditions
given above.
do not clean it as is. Also, be careful
not to allow flux to overflow above
the PC board or enter the inside of
the relay.
Please refer to
“the latest product specifications”
when designing your product.
• Requests to customers :
Panasonic Corporation Electromechanical Control Business Division
industrial.panasonic.com/ac/e/
© Panasonic Corporation 2019
ASCTB8E 201903
6
GUIDELINES FOR POWER REL
A
Y
S AND HIGH-CAPACITY DC CUT OFF RELAYS USAGE
For cautions for use, please read “GUIDELINES FOR REL
A
Y
U
SAGE”.
Precautions for Coil Input
Long term current carrying
Maximum allowable voltage and temperature rise
Proper usage requires that the rated coil voltage be impressed on the
coil. Note, however, that if a voltage greater than or equal to the
maximum continuous voltage is impressed on the coil, the coil may
burn or its layers short due to the temperature rise. Furthermore, do
not exceed the usable ambient temperature range listed in the catalog.
A circuit that will be carrying a current continuously for long periods
without relay switching operation. (circuits for emergency lamps, alarm
devices and error inspection that, for example, revert only during
malfunction and output warnings with form B contacts)
Continuous,
long-term current to the coil will facilitate deterioration of coil insulation
and characteristics due to heating of the coil itself.
Operate voltage change due to coil temperature rise
(Hot start)
For circuits such as these, please use a magnetic-hold type latching
relay. If you need to use a single stable relay, use a sealed type relay
that is not easily affected by ambient conditions and make a failsafe
circuit design that considers the possibility of contact failure or
disconnection.
In DC relays, after continuous passage of current in the coil, if the
current is turned OF
F
,
t
hen immediately turned ON again, due to the
temperature rise in the coil, the pick-up voltage will become somewhat
higher. Also, it will be the same as using it in a higher temperature
atmosphere. The resistance/temperature relationship for copper wire
is about 0.4% for 1°C, and with this ratio the coil resistance increases.
That is, in order to operate of the relay, it is necessary that the voltage
be higher than the pick-up voltage and the pick-up voltage rises in
accordance with the increase in the resistance value. However, for
some polarized relays, this rate of change is considerably smaller.
DC Coil operating power
Steady state DC current should be applied to the coil. The wave form
should be rectangular. If it includes ripple, the ripple factor should be
less than 5%.
However, please check with the actual circuit since the electrical
characteristics may vary. The rated coil voltage should be applied to
the coil and the set/reset pulse time of latching type relay differs for
each relays, please refer to the relay’s individual specifications.
Coil connection
When connecting coils of polarized relays, please check coil polarity
(+,-) at the internal connection diagram (Schematic). If any wrong
connection is made, it may cause
unexpected malfunction, like
abnormal heat, fire and so on, and circuit do not work. Avoid
impressing voltages to the set coil and reset coil at the same time.
Ambient Environment
Usage, Transport, and Storage Conditions
Dew condensation
During usage, storage, or transportation, avoid locations
subjected to direct sunlight and maintain normal temperature,
humidity and pressure conditions.
Condensation occurs when the ambient temperature drops
suddenly from a high temperature and humidity, or the relay is
suddenly transferred from a low ambient temperature to a high
temperature and humidity. Condensation causes the failures like
insulation deterioration, wire disconnection and rust etc.
Panasonic Corporation does not guarantee the failures caused
by condensation.
Temperature/Humidity/Pressure
When transporting or storing relays while they are tube
packaged, there are cases the temperature may differ from the
allowable range. In this case be sure to check the individual
specifications. Also allowable humidity level is influenced by
temperature, please check charts shown below and use relays
within mentioned conditions. (Allowable temperature values
differ for each relays, please refer to the relay’s individual
specifications.)
The heat conduction by the equipment may accelerate the
cooling of device itself, and the condensation may occur.
Please conduct product evaluations in the worst condition of
the actual usage. (Special attention should be paid when high
temperature heating parts are close to the device. Also please
consider the condensation may occur inside of the device.)
Icing
1)
T
e
mperature:
Condensation or other moisture may freeze on relays when the
temperature become lower than 0°C.This icing causes the sticking of
movable portion, the operation delay and the contact conduction failure
etc. Panasonic Corporation does not guarantee the failures caused by
the icing.
The tolerance temperature range differs for each relays,
please refer to the relay’s individual specifications
2) Humidity:
5 to 85 % RH
3) Pressure:
86 to 106 kPa
The heat conduction by the equipment may accelerate the cooling of
relay itself and the icing may occur. Please conduct product
evaluations in the worst condition of the actual usage.
Low temperature and low humidity
Humidity, %R.H.
85
The plastic becomes brittle if the switch is exposed to a low
temperature, low humidity environment for long periods of time.
High temperature and high humidity
Allowable range
(Avoid
(Avoid icing
condensation
when used at
when used at
temperatures
Storage for extended periods of time (including transportation periods)
at high temperature or high humidity levels or in atmospheres with
organic gases or sulfide gases may cause a sulfide film or oxide film to
form on the surfaces of the contacts and/or it may interfere with the
functions. Check out the atmosphere in which the units are to be
stored and transported.
temperatures
lower than 0
°
C)
higher than
)
0
°
C
5
–40
0
85
Ambient temperature,
°
C
Panasonic Corporation Electromechanical Control Business Division
industrial.panasonic.com/ac/e/
c
Panasonic Corporation 2019
ASCTB412E 201903
-1-
GUIDELINES FOR POWER RELAYS AND HIGH-CAPACITY DC CUT OFF RELAYS USAGE
Package
NOx Generation
In terms of the packing format used, make every effort to keep the
effects of moisture, organic gases and sulfide gases to the absolute
minimum.
When relay is used in an atmosphere high in humidity to switch a load
which easily produces an arc, the NOx created by the arc and the
water absorbed from outside the relay combine to produce nitric acid.
This corrodes the internal metal parts and adversely affects operation.
Avoid use at an ambient humidity of 85%RH or higher (at 20°C). If use
at high humidity is unavoidable, please contact our sales
representative.
Silicon
When a source of silicone substances (silicone rubber, silicone oil,
silicone coating materials and silicone filling materials etc.) is used
around the relay, the silicone gas (low molecular siloxane etc.) may be
produced.
This silicone gas may penetrate into the inside of the relay. When the
relay is kept and used in this condition, silicone compound may adhere
to the relay contacts which may cause the contact failure. Do not use
any sources of silicone gas around the relay (Including plastic seal
types).
Others
Cleaning
1) Although the environmentally sealed type relay (plastic sealed type,
etc.) can be cleaned, avoid immersing the relay into cold liquid (such
as cleaning solvent) immediately after soldering. Doing so may
deteriorate the sealing performance.
2) Cleaning with the boiling method is recommended(The temperature
of cleaning liquid should be 40°C or lower ).
Avoid ultrasonic cleaning on relays. Use of ultrasonic cleaning may
cause breaks in the coil or slight sticking of the contacts due to
ultrasonic energy.
Please refer to
“the latest product specifications”
when designing your product.
•Requests to customers:
Panasonic Corporation Electromechanical Control Business Division
industrial.panasonic.com/ac/e/
c
Panasonic Corporation 2019
ASCTB412E 201903
-2-
2019