PANASONIC-AHE62X1N
| Part # | PANASONIC-AHE62X1N |
| Download | PANASONIC-AHE62X1N |
Power Relays ( Over 2A )
HE-N RELAYS
Product Catalog
2022.4
Power Relays (Over 2A)
REL
A
Y
S
HE-N
High capacity 120A 490V AC 1 Form A power relay
FEATURES
〈
Protective construction
〉
Flux-resistant type
1. High capacity : Max. switching current 120A
2. Compact Size : W (50mm) x L (40mm) x H (43mm)
3. Contact GAP : Min.3.6 mm (Initial)
4. Insulation
distance (Initial) : Min.10.5mm (Clearance & Creepage)
5. Contributes to energy saving in devices by reducing
40
coil holding voltage*. Coil holding power : 400mW
*Coil holding voltage : the coil voltage after applying 100ms of the reted coil voltage
43
APPLICATIONS
1. Inverter
2. Battery storage system
3. Stationary charging stand
4. Industrial equipment
(
Unit
:
mm
)
ORDERING INFORMATION (PART NO. : Ordering part number for Japanese market)
AHE 6 2 X
N
Operate voltage
Rated coil voltag
e
(
DC
)
Part No.
Rated coil voltag
e
(
V
)
6 12 24 9
Contact material
N
:
AgNi type
Terminal shape
X
:
PC board termin
a
(
l wide
blade
)
2
:
Max.75
%
V of rated coil voltage
0
1 2 5
Contact arrangement, Contact rating
6
:
1 Form A, 120A
ORDERING INFORMATION (TYPE NO. : Ordering part number for non Japanese market)
HE
DC
1a N W
Y7
Operate voltage
N
:
Max.75
%
V of rated coil voltage
Rated coil voltag
e
(
DC
)
6, 9, 12, 24V
Contact arrangement
1a
:
1 Form A
Terminal shape
:
PC board termin
a
(
l wide
blade
)
Contact material, Contact rating
Y7
:
AgNi type, 120A
W
TYPES
” Type No. ” is ordering part number for non Japanese market. ” Part No. ” is ordering part number for Japanese market.
Standard packing
Contact arrangement
Rated coil voltage
Type No.
Part No.
Inner carton
Outer carton
6
9
V DC
V DC
HE
HE
1
aN-W-DC
aN-W-DC
6
V-Y
7
7
AHE
62
AHE
62
AHE
62
AHE
62
X
0
N
X
5
N
X
1
N
X
2
N
1
9
V-Y
1
Form A
10
pcs.
50
pcs.
12
V DC
24
V DC
HE
HE
1
aN-W-DC
12
V-Y
7
7
1
aN-W-DC
24
V-Y
Panasonic Industry Co., Ltd. Electromechanical Control Business Division
Panasonic Industry Co., Ltd. 2022
ASCTB405E 202
204
ー 1 ー
industrial.panasonic.com/ac/e/
•
Operatingꢀcharacteristicsꢀsuchꢀasꢀ‘Operateꢀvoltage’ꢀandꢀ‘Releaseꢀvoltage’ꢀareꢀinfluencedꢀbyꢀmountingꢀconditions,ꢀambientꢀtemperature,ꢀ
Power Relays (Over 2A) HE-N RELAYS
RATING
Coil data
etc.ꢀTherefore,ꢀpleaseꢀuseꢀtheꢀrelayꢀwithinꢀ±ꢀ5%ꢀofꢀratedꢀcoilꢀvoltage.
•‘Initial’ means the condition of products at the time of delivery.
Operate voltage
*
Release voltage
*
Rated operating current
Coil resistance
(±
10
%,ꢀatꢀ
20
°C)
Max.ꢀallowableꢀvoltage
Rated coil voltage
Ratedꢀoperatingꢀpower
(at
20
°C)
(at
20
°C)
(±
10
%,ꢀatꢀ
20
°C)
(at
55
°C)
6
9
V DC
V DC
417
mA
14
32
57
.
.
.
4
4
6
ꢀΩ
ꢀΩ
ꢀΩ
Max.
75
%ꢀVꢀofꢀ
Rated coil voltage
Rated coil voltage
(Initial)
(Initial)
Min.
%ꢀVꢀof
5
278
mA
110
%ꢀVꢀof
Rated coil voltage
2
,
500
mW
12
V DC
24
V DC
208
mA
104
mA
230
ꢀΩ
*square,ꢀpulseꢀdrive
Specifications
Item
Contact arrangement
Contact resistance (initial)
Max.
10
ꢀmΩꢀ(byꢀvoltageꢀdropꢀ
Contact material
AgNi type
Specifications
1
Form A
5
V DC
20
A)
Contact rating (resistive)
120
A
490
V A
C,ꢀ
120
A
60
V DC
Max.
ꢀ
s
witching
ꢀ
p
owerꢀ
(resistive)
Contact data
58
,
800
VA,ꢀ
7
,
200
W
Max.ꢀswitchingꢀvoltage
800
ꢀVꢀAC,ꢀ
60
V DC
Max.ꢀswitchingꢀcurrent
120
100
mA
Min.
000
ꢀMΩꢀ(Atꢀ
500
ꢀVꢀDC,ꢀMeasuredꢀportionꢀisꢀtheꢀsameꢀasꢀtheꢀcaseꢀofꢀdielectricꢀstrength.)
A
Min.ꢀswitchingꢀloadꢀ
5
V DC
(reference value)
*
1
Insulation resistance (initial)
1
,
Betweenꢀopenꢀcontacts
Betweenꢀcontactꢀandꢀcoil
2
5
,
000
Vrms for
000
Vrms for
1
1
min. (detection current:
10
mA)
min. (detection current:
10
mA)
Dielectric strength
(initial)
,
Surgeꢀwithstandꢀ
Betweenꢀcontactꢀandꢀcoil
10
,
000
V
voltage (initial)
*
2
40
to
100
%ꢀVꢀ(atꢀ-
40
to
55
°C)
50
to
60
%ꢀVꢀ(atꢀꢀ
55
to
85
°C)
Coil holding voltage
*
3
Operate time
Release time
Functional
Max.
30
ms (at rated coil voltage at
20
°C,ꢀwithoutꢀbounce)
Max.
10
ms (at rated coil voltage at
20
°C,ꢀwithoutꢀbounce,ꢀwithoutꢀdiode)
98
m/s
2
(half-sine shock pulse:
11
ꢀms,ꢀdetectionꢀtime:ꢀ
10
ꢀμs)
Time characteristics
(initial)
Shock resistance
980
m/s
2
(half-sine shock pulse:
6
ms)
Destructive
Functional
10
to
55
Hz (at double amplitude of
10
to
55
Hz (at double amplitude of
Min.
10
6
ope. (at
180
times/min.)
1
.
.
0
ꢀmm,ꢀdetectionꢀtime:ꢀ
10
ꢀμs)
Vibration resistance
Expected life
Destructive
Mechanical
1
5
mm)
Ambient temperature: –
40
to
85
°C
Conditionꢀforꢀuse,ꢀ
transportation and
storage
*
4
Conditions
(When using at
55
°Cꢀorꢀhigher,ꢀtheꢀcoilꢀholdingꢀvoltageꢀshouldꢀbeꢀ
50
%ꢀVꢀtoꢀ
60
%ꢀV)
Humidity:
5
to
85
%ꢀR.H.ꢀ(Avoidꢀicingꢀwhenꢀusingꢀatꢀtemperaturesꢀlowerꢀthanꢀ
0
°C.)
Unitꢀweight
Approx.
115
g
*1.Thisꢀvalueꢀcanꢀchangeꢀdueꢀtoꢀtheꢀswitchingꢀfrequency,ꢀenvironmentalꢀconditions,ꢀandꢀdesiredꢀreliabilityꢀlevel,ꢀthereforeꢀitꢀisꢀrecommendedꢀtoꢀcheckꢀthisꢀwithꢀtheꢀactualꢀload.
*2.Waveꢀisꢀstandardꢀshockꢀvoltageꢀofꢀ±1.2×50μsꢀaccordingꢀtoꢀJEC-212-1981.
*3.Coilꢀholdingꢀvoltageꢀisꢀtheꢀcoilꢀvoltageꢀafterꢀ100ꢀmsꢀfollowingꢀapplicationꢀofꢀtheꢀratedꢀcoilꢀvoltage.
*4.The upper operation ambient temperature limit is the maximum temperature that can satisfy the coil temperature rise value.
Referꢀtoꢀ”1.ꢀUsage,ꢀtransportꢀandꢀstorageꢀconditions”ꢀinꢀNOTES.
Expected electrical life
Conditions: Resistive load
Type
Switchingꢀcapacity
Number of operations
10
3
ope. (at
85
°C,ꢀON:OFFꢀ=ꢀ
10
3
ope. (at
85
°C,ꢀON:OFFꢀ=ꢀ
55
90
A
A
A
A
800
V AC
490
V AC
490
V AC
60
V DC
Min.
10
Min.
10
10
x
x
1
1
s:
9
9
s)
s)
s)
s:
1
Form A
120
120
Min.
3
ope.
(at
85
°C,ꢀON:OFFꢀ=ꢀ
1
s:
9
Min.
10
3
ope.
(ON:OFFꢀ=ꢀ
s: s)
1
9
Panasonic Industry Co., Ltd. Electromechanical Control Business Division
Panasonic Industry Co., Ltd. 2022
ASCTB405E 202
204
ー 2 ー
industrial.panasonic.com/ac/e/
Power Relays (Over 2A) HE-N RELAYS
REFERENCE DATA
1-1.Max.ꢀswitchingꢀcapacityꢀ
1-2.Max.ꢀswitchingꢀcapacity
2.Coil temperature characteristics
(Average)
(AC resistive load)
(DC resistive load)
Tested sample
:
HE1aN-W-DC12-Y7, 6pcs.
Measured portion
:
Coil inside
Contact carrying current
, 55
, 85
:
120A Ambient
temperature
:
20
℃ ℃ ℃
1,000
500
1,000
500
80
20
℃
55
℃
85
℃
70
60
50
40
30
20
100
50
100
50
10
10
1
1
0.5
0.5
10
0
30
100
500 1,000
30
100
500 1,000
40
50
60
70
80
90 100
110
Contact voltage, V
Contact voltage, V
Coil applied voltage, %V
3.Ambient temperature characteristics
Tested sample
:
HE-N, 6 pcs.
30
20
10
ー
60
ー
40
ー
20
0
20 40
60 80
100
Ambient
temperature,
°
C
ー
10
Operate
voltage
ー
20
ー
30
Release
voltage
4.Electrical life test
(Resistiveꢀloadꢀ490VꢀACꢀ120A,ꢀatꢀ85°C)
Tested sample
:
HE1aN-W-DC12-Y7, 6 pcs.
Operation frequency
:
6 times/min.
(
ON
:
OFF=1s
:
9s
)
Change of Operate and release voltage
12
Change of contact resistance
10
Circuit
:
9
8
7
6
5
4
3
2
1
10
Operate voltage
8
Max.
Ave.
Min.
6
490V AC
4
12V DC
Release voltage
Max.
Ave.
Min.
2
Max.
Ave.
Min.
0
0
0
0
1
1
No. of operations
,
×
10
3
No. of operations
,
×
10
3
Panasonic Industry Co., Ltd. Electromechanical Control Business Division
Panasonic Industry Co., Ltd. 2022
ASCTB405E 202
204
ー 3 ー
industrial.panasonic.com/ac/e/
Power Relays (Over 2A) HE-N RELAYS
CAD
ꢀTheꢀCADꢀdataꢀofꢀtheꢀproductsꢀwithꢀaꢀ“CAD”ꢀmarkꢀcanꢀbeꢀdownloadedꢀfromꢀourꢀWebsite.
DIMENSIONS
CAD
Unit: mm
External dimensions
Recommended PC board pattern
(BOTTOM VIEW)
40
25.9
50
19.4
R0.3
1.2
(
R
)
32
7.7
18
±
0.2
TOLERANCE:
±
0.1
32
0.8
Schematic
(BOTTOM VIEW)
1
4
TOLERANCE;
less than 10mm:
±
0.3
min.10mm~ :
±
0.5
(
7.9
)
25.9
6
5
Note: Terminal dimension is a value without pre-soldering thickness.
Eachꢀstandardꢀmayꢀbeꢀupdatedꢀatꢀanyꢀtime,ꢀsoꢀpleaseꢀcheckꢀourꢀWebsiteꢀforꢀtheꢀlatestꢀinformation.
SAFETY STANDARDS
UL/C-UL (Approved)
CSA (Approved)
CSAꢀstandardꢀcertifiedꢀbyꢀC-UL
Ambient
temperature
File No.
Contact rating
Operations
Making
55
A Carrying
133
A
6
×
10
3
10
3
Breaking
55
Use
A
600
V AC General
85
°C
E43028
10
×
90
A
490
V AC Resistive
85
°C
VDE (Approved)
Ambient
temperature
File No.
Contact rating
Operations
10
3
120
Making
40
A Carrying
120
Breaking
40 480
V AC
A
800
ꢀVꢀACꢀ(cosφ=
1
.
0
)
85
°C
40006681
A
10
×
10
3
85
°C
A
INSULATION CHARACTERISTICS (IEC61810-1)
Item
Characteristics
Clearance / Creepage distance (IEC61810-
1
)
Min.
5
.
5
mm /
8
mm
Category of protection (IEC61810-
Tracking resistance (IEC60112)
Insulation material group
Over voltage category
Rated voltage
1
)
RT II
PTI
175
III a
III
800
2
V
Pollution degree
Typeꢀofꢀinsulationꢀ(Betweenꢀcontactꢀandꢀcoil)
Typeꢀofꢀinsulationꢀ(Betweenꢀopenꢀcontact)
Basic insulation
micro disconnection
Note: Actual value
Panasonic Industry Co., Ltd. Electromechanical Control Business Division
Panasonic Industry Co., Ltd. 2022
ASCTB405E 202
204
ー 4 ー
industrial.panasonic.com/ac/e/
Note:ꢀ
In
ꢀ
a
ddition
ꢀ
t
he
ꢀ
h
umidity
ꢀ
r
ange
ꢀ
d
epends
ꢀ
o
n
ꢀ
t
emperature.The
ꢀ
a
llowable
ꢀ
r
angesꢀ
areꢀasꢀshownꢀinꢀtheꢀfigure.
Power Relays (Over 2A) HE-N RELAYS
NOTES
For cautions for use, please read “GENERAL APPLICATION GUIDELINES”.
Cautions for usage of HE-PV relay
Usage,ꢀtransportꢀandꢀstorageꢀconditions
1. Ambient temperature: -40 to 85°C
[
T
e
mperatureꢀandꢀhumidityꢀrangeꢀforꢀusage,ꢀtransportꢀandꢀstorage]
Humidity (% RH)
(Whenꢀusingꢀatꢀ55°Cꢀorꢀhigher,ꢀtheꢀcoilꢀholdingꢀvoltageꢀshouldꢀ
beꢀ50%ꢀVꢀtoꢀ60%ꢀV)
2.ꢀHumidity:ꢀ5ꢀtoꢀ85%RH
85
(Avoidꢀicingꢀwhenꢀusingꢀatꢀtemperaturesꢀlowerꢀthanꢀ0°C.)
Allowable range
Avoid con
Avoid icing
densation when
used at tem
peratures higher
than 0
°
C
when used at
temperatures
lower than 0
°
C
5
ー40
0
55
85
Ambient temperature (℃)
When using 55 ~ 85℃
Coil holding Voltag
e
:
50 ~ 60% V
Panasonic Industry Co., Ltd. Electromechanical Control Business Division
Panasonic Industry Co., Ltd. 2022
ASCTB405E 202
204
ー 5 ー
industrial.panasonic.com/ac/e/
Power Relays (Over 2A) HE-N RELAYS
DC load guidelines
About parallel relay connections
InꢀcaseꢀtheꢀrelayꢀisꢀusedꢀasꢀaꢀDCꢀhighꢀvoltageꢀswitch,ꢀtheꢀfinalꢀ
failureꢀmodeꢀmayꢀbeꢀuninterruptible.Inꢀtheꢀeventꢀthatꢀtheꢀpowerꢀ
supplyꢀcannotꢀbeꢀcutꢀoff,ꢀinꢀtheꢀworstꢀcase,theꢀfireꢀmayꢀspreadꢀ
toꢀtheꢀsurroundingꢀarea.ꢀTherefore,ꢀconfigureꢀtheꢀpowerꢀsupplyꢀ
soꢀthatꢀitꢀcanꢀbeꢀturnedꢀoffꢀwithinꢀoneꢀsecond.ꢀAlso,considerꢀaꢀ
fail safe circuit for your equipment.
Whenꢀmultipleꢀrelaysꢀareꢀconnectedꢀinꢀparallel,ꢀdesignꢀtheꢀ
equipmentꢀsoꢀthatꢀtheꢀloadꢀappliedꢀtoꢀeachꢀrelayꢀisꢀwithinꢀtheꢀ
specifiedꢀrange.
(Concentration of load on one relay leads to early failure.)
Ambient Atmosphere
Whenꢀusingꢀanꢀinductiveꢀloadꢀ(Lꢀload)ꢀwithꢀL/Rꢀ>ꢀ1ꢀms,ꢀtakeꢀ
surgeꢀabsorptionꢀmeasuresꢀinꢀparallelꢀwithꢀtheꢀinductiveꢀload.
If the relay is used or stored in an atmosphere of corrosive
gas (Sulfurous acid gas: SO
2
,ꢀhydrogenꢀsulfideꢀgas:ꢀH S),ꢀ
2
corrosiveꢀgasꢀcomponentsꢀmayꢀadhereꢀtoꢀtheꢀcontacts,ꢀ
resulting in contact failure. Do not use or store the relay in
such an atmosphere.
Coil surge absorber
PleaseꢀuseꢀaꢀVaristorꢀ(ZNR)ꢀorꢀZenerꢀdiodeꢀ(ZD)ꢀwhichꢀtheꢀ
clamp voltage is at least 3 times larger than the rated voltage for
the purpose of the coil surge absorber.
Method for reducing coil holding voltage
If the clamp voltage is less than 3 times larger than the rated
voltage,ꢀelectricalꢀlifeꢀofꢀtheꢀrelayꢀspecifiedꢀinꢀtheꢀspecificationsꢀ
shall not be secured because the contact release speed
becomesꢀslower.
WhenꢀtheꢀcoilꢀholdingꢀvoltageꢀisꢀusedꢀbyꢀPWMꢀcontrol,ꢀtheꢀ
release voltage varies depending on the operating temperature
andꢀoperatingꢀconditions.ꢀTherefore,ꢀpleaseꢀevaluateꢀtheꢀcoilꢀ
holdingꢀvoltageꢀunderꢀtheꢀworstꢀoperatingꢀconditions.
Recommended operating condition:
[Exampleꢀ1:ꢀWhenꢀVaristorꢀ(ZNR)ꢀisꢀuse]
Periods:ꢀ20ꢀkHzꢀtoꢀ100ꢀkHz,ꢀDutyꢀRatio:ꢀ50%
Energy capability: Min.
1
J
Recommended
Varistor
(However,ꢀpleaseꢀsetꢀupꢀtheꢀvalueꢀwithꢀ
considerationꢀofꢀtheꢀworstꢀvalueꢀinꢀuse
condition.)
About conductor cross-sectional area during mounting
Whenꢀdesigningꢀaꢀprintedꢀcircuitꢀboard,ꢀensureꢀthatꢀthereꢀ
isꢀsufficientꢀmarginꢀinꢀtheꢀconductorꢀwidthꢀandꢀconductorꢀ
spacing.ꢀ
T
o
ꢀreduceꢀtheꢀtemperatureꢀrise,ꢀreferꢀtoꢀtheꢀcross-
sectionalꢀareaꢀofꢀtheꢀconductorꢀofꢀULꢀ508.
Min.
300
%ꢀofꢀratedꢀvoltage
(Recommended Varistor voltage is at
36
V or
moreꢀwhenꢀtheꢀcoilꢀratedꢀvoltageꢀisꢀatꢀ
12
V
.
)
Varistor Voltage
[Exampleꢀ2:ꢀWhenꢀZenerꢀdiodeꢀ(circuit)ꢀisꢀuse]
(Setꢀtheꢀclampꢀvoltageꢀatꢀ36ꢀVꢀorꢀmoreꢀwhenꢀtheꢀcoilꢀ1ꢀratedꢀ
voltage is at 12 V.)
[ꢀ1ꢀ]
12V
ZD
36V
Relay
Clamp voltage
ZD36V Zener Voltage
Coil
D
[ꢀ2ꢀ]
12V
ZD48V Zener
Voltage
Relay
Coil
Clamp voltage
48V
-
12V=36V
ZD
48V
Panasonic Industry Co., Ltd. Electromechanical Control Business Division
Panasonic Industry Co., Ltd. 2022
ASCTB405E 202
204
ー 6 ー
industrial.panasonic.com/ac/e/
GUIDELINES FOR POWER, HIGH-CAPACITY DC CUT OFF AND SAFETY RELAYS USAGE
For cautions for use, please read “GUIDELINES FOR REL
A
Y
U
SAGE”.
Precautions for Coil Input
Long term current carrying
Maximum allowable voltage and temperature rise
Proper usage requires that the rated coil voltage be impressed on
the coil. Note, however, that if a voltage greater than or equal to the
maximum continuous voltage is impressed on the coil, the coil may
burn or its layers short due to the temperature rise. Furthermore, do
not exceed the usable ambient temperature range listed in the
catalog.
A circuit that will be carrying a current continuously for long periods
without relay switching operation. (circuits for emergency lamps,
alarm devices and error inspection that, for example, revert only
during malfunction and output warnings with form B contacts)
Continuous, long-term current to the coil will facilitate deterioration
of coil insulation and characteristics due to heating of the coil itself.
For circuits such as these, please use a magnetic-hold type latching
relay. If you need to use a single stable relay, use a sealed type
relay that is not easily affected by ambient conditions and make a
failsafe circuit design that considers the possibility of contact failure
or disconnection.
Operate voltage change due to coil temperature rise
In DC relays, after continuous passage of current in the coil, if the
current is turned OF
F
,
t
hen immediately turned ON again, due to the
temperature rise in the coil, the operate voltage will become
somewhat higher. Also, it will be the same as using it in a higher
temperature atmosphere. The resistance/temperature relationship
for copper wire is about 0.4% for 1°C, and with this ratio the coil
resistance increases. That is, in order to operate of the relay, it is
necessary that the voltage be higher than the operate voltage and
the operate voltage rises in accordance with the increase in the
resistance value. However, for some polarized relays, this rate of
change is considerably smaller.
DC Coil operating power
Steady state DC current should be applied to the coil. The wave
form should be rectangular. If it includes ripple, the ripple factor
should be less than 5%.
However, please check with the actual circuit since the electrical
characteristics may vary. The rated coil voltage should be applied to
the coil and the set/reset pulse time of latching type relay differs for
each relays, please refer to the relay’s individual specifications.
Coil connection
When connecting coils of polarized relays, please check coil polarity
(+,-) at the internal connection diagram (Schematic). If any wrong
connection is made, it may cause
unexpected malfunction, like
abnormal heat, fire and so on, and circuit do not work. Avoid
impressing voltages to the set coil and reset coil at the same time.
Ambient Environment
Dew condensation
Usage, Transport, and Storage Conditions
During usage, storage, or transportation, avoid locations subjected
to direct sunlight and maintain normal temperature, humidity and
pressure conditions.
Condensation occurs when the ambient temperature drops suddenly
from a high temperature and humidity, or the relay is suddenly
transferred from a low ambient temperature to a high temperature
and humidity. Condensation causes the failures like insulation
deterioration, wire disconnection and rust etc.
Temperature/Humidity/Pressure
When transporting or storing relays while they are tube packaged,
there are cases the temperature may differ from the allowable
range. In this case be sure to check the individual specifications.
Also allowable humidity level is influenced by temperature, please
check charts shown below and use relays within mentioned
conditions. (Allowable temperature values differ for each relays,
please refer to the relay’s individual specifications.)
Panasonic Industry Co., Ltd. does not guarantee the failures caused
by condensation.
The heat conduction by the equipment may accelerate the cooling
of device itself, and the condensation may occur.
Please conduct product evaluations in the worst condition of the
actual usage. (Special attention should be paid when high
temperature heating parts are close to the device. Also please
consider the condensation may occur inside of the device.)
Icing
1)
T
e
mperature:
The tolerance temperature range differs for each relays, please
refer to the relay’s individual specifications
2) Humidity: 5 to 85 % RH
Condensation or other moisture may freeze on relays when the
temperature become lower than 0°C.This icing causes the sticking
of movable portion, the operation delay and the contact conduction
failure etc. Panasonic Industry Co., Ltd. does not guarantee the
failures caused by the icing.
3) Pressure: 86 to 106 kPa
Humidity (% RH)
The heat conduction by the equipment may accelerate the cooling
of relay itself and the icing may occur. Please conduct product
evaluations in the worst condition of the actual usage.
Low temperature and low humidity
85
The plastic becomes brittle if the switch is exposed to a low
temperature, low humidity environment for long periods of time.
High temperature and high humidity
Allowable range
Avoid icing
Avoid con
when used at
temperatures
lower than 0
°
C
densation when
used at tem
peratures higher
than 0
°
C
Storage for extended periods of time (including transportation
periods) at high temperature or high humidity levels or in
atmospheres with organic gases or sulfide gases may cause a
sulfide film or oxide film to form on the surfaces of the contacts and/
or it may interfere with the functions. Check out the atmosphere in
which the units are to be stored and transported.
5
40
0
85
Ambient temperature (℃)
Panasonic Industry Co., Ltd. Electromechanical Control Business Division
Panasonic Industry Co., Ltd. 2022
ASCTB412E 202204
ー 7 ー
industrial.panasonic.com/ac/e/
GUIDELINES FOR POWER, HIGH-CAPACITY DC CUT OFF AND SAFETY RELAYS USAGE
Package
NOx Generation
In terms of the packing format used, make every effort to keep the
effects of moisture, organic gases and sulfide gases to the absolute
minimum.
When relay is used in an atmosphere high in humidity to switch a
load which easily produces an arc, the NOx created by the arc and
the water absorbed from outside the relay combine to produce nitric
acid.
Silicon
When a source of silicone substances (silicone rubber, silicone oil,
silicone coating materials and silicone filling materials etc.) is used
around the relay, the silicone gas (low molecular siloxane etc.) may
be produced.
This corrodes the internal metal parts and adversely affects
operation.
Avoid use at an ambient humidity of 85%RH or higher (at 20°C). If
use at high humidity is unavoidable, please contact our sales
representative.
This silicone gas may penetrate into the inside of the relay. When
the relay is kept and used in this condition, silicone compound may
adhere to the relay contacts which may cause the contact failure.
Do not use any sources of silicone gas around the relay (Including
plastic seal types).
Others
Cleaning
• Although the environmentally sealed type relay (plastic sealed type,
etc.) can be cleaned, avoid immersing the relay into cold liquid (such
as cleaning solvent) immediately after soldering. Doing so may
deteriorate the sealing performance.
• Cleaning with the boiling method is recommended(The temperature
of cleaning liquid should be 40°C or lower ).
Avoid ultrasonic cleaning on relays. Use of ultrasonic cleaning may
cause breaks in the coil or slight sticking of the contacts due to
ultrasonic energy.
Please refer to
“the latest product specifications”
when designing your product.
•Requests to customers:
Panasonic Industry Co., Ltd. Electromechanical Control Business Division
Panasonic Industry Co., Ltd. 2022
ASCTB412E 202204
ー 8 ー
industrial.panasonic.com/ac/e/
Electromechanical Control Business Division
1006, Oaza Kadoma, Kadoma-shi, Osaka 571-8506, Japan
industral.panasonic.com/ac/e/
Specifications are subject to change without notice.
2022.4
©Panasonic Industry Co., Ltd. 2022
ASCTB405E 202204