PANASONIC-ALQ3F48
| Part # | PANASONIC-ALQ3F48 |
| Download | PANASONIC-ALQ3F48 |
Power Relays ( Over 2A )
LQ RELAYS
Product Catalog
2023.6
Power Relays ( Over 2 A )
LQ RELAYS
1
2
3
Compliant with IEC/EN60335-1* *
/EN60079-15* (
VDE approved ) 1 Form A/1 Form C 10 A small power relays
FEATURES
Protective construction: Sealed
●
S
mall and slim:
10 mm ( W ) × 20 mm ( L ) × 16 mm ( H )
●
C
ompact with high capacity:
1 Form A / 1 Form C, 10 A
10
20
●
C
lass ” F ” coil is available.
16
●
C
ontact rating at 105 ℃ is approved by
UL/C-UL ( Class ” F ” coil only )
Please refer to ” SAFETY STANDARDS ” about the detail of contact
rating.
●
S
urge withstand voltage
( Between contact and coil ) : 8,000 V
●
H
igh Dielectric strength voltage
( Between contact and coil ) : 4,000 V rms
(
Unit
:
mm
)
●
C
ompliant with IEC/EN60335-1 *
1
*
2
( VDE approved )
*1: Common safety standard for major electrical appliance
*2: 1 Form A type is compatible except for the bottom surface
●
C
ompliant with IEC/EN60079-15 *
3
( VDE approved )
*3: Explosion-proof certification
TYPICAL APPLICATIONS
●
H
ome appliance
●
I
ndustrial equipment
ORDERING INFORMATION ( PART NO. )
ALQ
Contact arrangement
Coil insulation class
Rated coil voltag
e
(
DC
)
05
:
5
V
,
0
6
:
6
V
,
0
9
:
9
V
,
1
2
:
12
V
,
1
8
:
18
V
,
2
4
:
24 V
18
:
18
V
,
2
4
:
24 V
Packing style
Nil
:
Carton
S
:
Tube
1
:
1 Form C
3
:
1 Form A
Nil
:
Class B insulation
F
:
Class F insulation
Note) 1: The “S” at the end of the part number only appears on the inner and outer packing.
It does not appear on the relay itself.
2: 48V DC types is also available. Please contact our sales representative for details.
3: Reflow mounting compatible products (Flux-resistant type) are also available.
4: Inrush type / Reinforced insulation compatible products are also available.
Panasonic Industry Co., Ltd. Electromechanical Control Business Division
industrial.panasonic.com/ac/e/
Panasonic Industry Co., Ltd. 2023
ASCTB92E 202306
ー 1 ー
Power Relays ( Over 2 A ) LQ RELAYS
TYPES
■ PC board terminal
Part No. *
Class B insulation
Standard packing
Contact arrangement
Rated coil volatage
Class F insulation
ALQ3F05
ALQ3F06
ALQ3F09
ALQ3F12
ALQ3F18
ALQ3F24
ALQ1F05
ALQ1F06
ALQ1F09
ALQ1F12
ALQ1F18
ALQ1F24
Inner carton
Outer carton
5 V DC
6 V DC
ALQ305
ALQ306
ALQ309
ALQ312
ALQ318
ALQ324
ALQ105
ALQ106
ALQ109
ALQ112
ALQ118
ALQ124
9 V DC
1 Form A
12 V DC
18 V DC
24 V DC
5 V DC
Carton: 100 pcs.
Tube: 50
pcs.
Carton: 500
pcs.
Tube: 1,000 pcs.
6 V DC
9 V DC
1 Form C
12 V DC
18 V DC
24 V DC
* Tube packing types available. When ordering, please add suffix ” S “.
Reflow mounting compatible products ( Flux-resistant type ) and Inrush type/Reinforced insulation compatible products,please contact our sales representative for
details.
RATING
■ Coil data
• Operating
characteristics such as ” Operate voltage ” and ” Release voltage ” are influenced by mounting conditions or
ambient temperature, etc.
Therefore, please use the relay within ±5 % of rated coil voltage.
• “
Initial ” means the condition of products at the time of delivery.
Operate
Release
Rated operating
current
( ±10 %, at 20 ℃ )
Rated
operating
power
Contact
arrangement
Rated coil
voltage
Coil resistance
( ±10 %, at 20 ℃ )
Max. allowable
voltage
1
1
voltage*
voltage*
( at 20 ℃ )
( at 20 ℃ )
5 V DC
6 V DC
9 V DC
12 V DC
18 V DC
24 V DC
5 V DC
6 V DC
9 V DC
12 V DC
18 V DC
24 V DC
40 mA
33.3 mA
22.2 mA
16.7 mA
11.1 mA
8.3 mA
80 mA
66.7 mA
44.4 mA
33.3 mA
22.2 mA
16.7 mA
125
180
405
720
1,620
2,880
62.5 Ω
90
202.5 Ω
360
810
Ω
Ω
Ω
Ω
Ω
Ω
Max. 75 % V
of rated coil
voltage
Min. 5 % V
of rated coil
voltage
130 % of rated coil
2
voltage ( at 85 ℃ )
*
1 Form A
1 Form C
200 mW
400 mW
180 % of rated coil
voltage ( at 20 ℃ )
( initial )
( initial )
Ω
Max. 75 % V
of rated coil
voltage
Min. 5 % V
of rated coil
voltage
110 % of rated coil
2
voltage ( at 85 ℃ )
*
150 % of rated coil
voltage ( at 20 ℃ )
Ω
Ω
Ω
( initial )
( initial )
1,440
*1: Square, pulse drive
*2: When using relays in a high ambient temperature, consider the operate voltage rise due to the high temperature ( a rise of approx. 0.4 % V for each 1 ℃ with 20 ℃
as a reference ) and use a coil impressed voltage that is within the maximum applied voltage range.
Panasonic Industry Co., Ltd. Electromechanical Control Business Division
industrial.panasonic.com/ac/e/
Panasonic Industry Co., Ltd. 2023
ASCTB92E 202306
ー 2 ー
Power Relays ( Over 2 A ) LQ RELAYS
■ Specifications
Item
Specifications
Contact arrangement
1 Form A
1 Form C
Contact resistance
( initial )
Contact material
Max. 100 mΩ ( by voltage drop 6 V DC 1 A )
AgNi type
Form A contact:
10 A 125 V AC, 5 A 250 V AC, 5 A 30 V DC
Contact rating
( resistive )
5 A 30 V DC, 10 A 125 V AC, 5 A 250 V AC
Form B contact:
3 A 125 V AC, 2 A 250 V AC, 1 A 30 V DC
Contact data
Form A contact: 1,250 VA, 150 W
Form B contact:
500 VA,
30 W
Max. switching power
( resistive )
1,250 VA, 150 W
250 V AC, 30 V DC
Max. switching voltage
Max. switching current
Min. switching load
Form A contact:
10 A ( 125 V AC ) , 5 A ( 30 V DC )
Form B contact:
3 A ( 125 V AC ) , 1 A ( 30 V DC )
10 A ( 125 V AC ) , 5 A ( 30 V DC )
100 mA 5 V DC
1
( reference value ) *
Insulation resistance ( initial )
Min. 1,000 MΩ ( at 500 V DC, Measured portion is the same as the case of dielectric strength )
1,000 V rms for 1 min ( detection current: 10 mA )
750 V rms for 1 min ( detection current: 10 mA )
Between open contacts
Dielectric
strength
( initial )
Between contact and
coil
4,000 V rms for 1 min ( detection current: 10 mA )
Surge
withstand
voltage
Between contact and
coil
8,000 V
2
( initial ) *
Time
Operate time
Release time
Max. 20 ms ( at rated coil voltage, at 20 ℃, without bounce )
characteristics
( initial )
Max. 20 ms ( at rated coil voltage, at 20 ℃, without bounce, with diode )
2
2
294 m/s
( half-sine shock pulse: 11 ms,
196 m/s
( half-sine shock pulse: 11 ms,
Functional
Shock
resistance
detection time: 10 µs )
detection time: 10 µs )
2
Destructive
Functional
Destructive
Mechanical life
Conditions for usage,
transport and storage*
980 m/s
( half-sine shock pulse: 6 ms )
10 to 55 Hz ( at double amplitude of 1.6 mm, detection time: 10 µs )
10 to 55 Hz ( at double amplitude of 2 mm )
Vibration
resistance
6
Expected life
Conditions
Unit weight
Min. 10 × 10
ope. ( at 180 times/min )
4
Ambient temperature: -40 to +85 ℃*
3
Humidity: 5 to 85 % RH ( Avoid icing and condensation )
Approx. 7 g
Notes) Specifications will vary with foreign standards certification ratings.
*1: This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load.
*2: Wave is standard shock voltage of ±1.2 × 50 µs according to JEC-212-1981
*3: For ambient temperature, please read ” GUIDELINES FOR RELAY USAGE “.
*4: When using relays in a high ambient temperature, consider the operate voltage rise due to the high temperature ( a rise of approx. 0.4 % V for each 1 ℃ with 20 ℃
as a reference ) and use a coil impressed voltage that is within the maximum applied voltage range.
■ Expected electrical life
Condition: Resistive load, at 20 ℃, at 20 times/min, with diode
Type
Switching capacity
5 A
30 V DC
10 A 125 V AC
5 A 250 V AC
5 A
30 V DC
10 A 125 V AC
5 A 250 V AC
3 A 125 V AC
2 A 250 V AC
1 A
30 V DC
Number of operations
3
100 × 10
ope.
3
1 Form A
50 × 10
ope.
3
50 × 10
ope.
3
100 × 10
ope.
Form A
contact
3
50 × 10
ope.
3
50 × 10
ope.
1 Form C
3
200 × 10
ope.
Form B
contact
3
200 × 10
ope.
3
100 × 10
ope.
Panasonic Industry Co., Ltd. Electromechanical Control Business Division
industrial.panasonic.com/ac/e/
Panasonic Industry Co., Ltd. 2023
ASCTB92E 202306
ー 3 ー
Power Relays ( Over 2 A ) LQ RELAYS
REFERENCE DATA
1-1. Max. switching capacity
1-2. Max. switching capacity
( 1 Form C )
2. Switching life curve
( Form A contact )
( 1 Form A )
Ambient temperature
:
room temperature
Ambient temperature
:
room temperature
100
100
100
AC resistive load Form A contact
AC resistive load
10
10
5
3
2
125V AC
5
resistive load
10
AC resistive load Form B contact
1
1
250V AC
resistive load
1
10
100
1,000
0
2
4
6
8
10
10
100
1,000
Contact voltag
e
(
V
)
Contact voltag
e
(
V
)
Contact curre
n
(
t A
)
3-1. Coil temperature characteristics
( 1 Form A )
3-2. Coil temperature characteristics
( 1 Form C )
Measured portion
:
Coil inside
Contact carrying current
:
5A, 10A
Measured portion
:
Coil inside
Contact carrying current
:
5A, 10A
70
70
10A 85
℃
60
60
10A 85
℃
10A 70
℃
50
50
10A 70
℃
5A 70
℃
40
40
5A 85
℃
5A 70
℃
30
30
5A 85
℃
20
20
10
10
0
0
100
120
140
160
180
100 110 120 130 140 150 160
Coil applied voltag
e
(
%V
)
Coil applied voltag
e
(
%V
)
4-1. Ambient temperature characteristics
4-2. Ambient temperature characteristics
( 1 Form A )
( 1 Form C )
Contact carrying current
:
5A, 10A
Measured portion
:
Coil inside
①
Allowable ambient temperature against %
coil voltag
e
(
max. inside the coil tempera-
ture set as 130
℃
)
(
Carrying curren
t
:
5 A
)
Contact carrying current
:
5A, 10A
400
400
①
②
Allowable ambient temperature against %
coil voltag
e
(
max. inside the coil tempera-
ture set as 130
℃
(
Carrying curren
t
:
10 A
)
②
300
300
③
Allowable ambient temperature against %
coil voltag
e
(
max. inside the coil tempera-
ture set as 115
℃
)
(
Carrying curren
t
:
5 A
)
④
Allowable ambient temperature against %
coil voltag
e
(
max. inside the coil tempera-
ture set as 115
℃
)
(
Carrying curren
t
:
10 A
)
⑤
Operate voltage with a hot-start condition of
100%V on the coi
l
(
Carrying curren
t
:
10 A
)
⑥
Operate voltage with a hot-start condition of
100%V on the coi
l
(
Carrying curren
t
:
5 A
)
①
②
③
③
200
100
200
④
④
⑥
⑥
100
⑦
⑤
⑤
⑦
0
20 30 40 50 60 70 80 90
0
20 30 40 50 60 70 80 90
⑦
Operate voltage
Ambient temperatur
e
(
°
C
)
Ambient temperatur
e
(
°
C
)
Panasonic Industry Co., Ltd. Electromechanical Control Business Division
industrial.panasonic.com/ac/e/
Panasonic Industry Co., Ltd. 2023
ASCTB92E 202306
ー 4 ー
Power Relays ( Over 2 A ) LQ RELAYS
DIMENSIONS ( Unit: mm )
CAD
The CAD data of the products with a ꢀꢁCAD ꢀ mark can be downloaded from our Website.
■ 1
Form A
External dimensions
Recommended
PC board pattern
( BOTTOM VIEW )
Schematic
( BOTTOM VIEW )
CAD
10.16
7.62
4
ー
φ
1.3
20
Tolerance
±
0.1
φ
0.5
1.11
0.3
10.16
0.3
0.8
7.62
7.62
General tolerance
Less than 1 m
m
:
±
0.2
Min. 1 mm less than 5 m
m
:
±
0.3
Min. 5 m
m
:
±
0.4
■ 1
Form C
External dimensions
Recommended
PC board pattern
( BOTTOM VIEW )
Schematic
( BOTTOM VIEW )
CAD
10.16 5.08
2.54
20
5
ー
φ
1.3
Tolerance
±
0.1
0.3
0.3
0.8
φ
0.5
0.3
7.62
5.08
10.16
1.11
2.54
General tolerance
Less than 1 m
m
:
±
0.2
Min. 1 mm less than 5 m
m
:
±
0.3
Min. 5 m
m
:
±
0.4
Panasonic Industry Co., Ltd. Electromechanical Control Business Division
industrial.panasonic.com/ac/e/
Panasonic Industry Co., Ltd. 2023
ASCTB92E 202306
ー 5 ー
Power Relays ( Over 2 A ) LQ RELAYS
SAFETY STANDARDS
Each standard may be updated at any time, so please check our Website for the latest information.
■ UL/C-UL ( Approved )
1 Form A ( ALQ3** )
1 Form C ( ALQ1** )
Ambient
Ambient
File No.
Contact rating
Operations
File No.
Contact
Contact rating
Operations
temperature
temperature
3
3
10 A 277 V AC General use
5 A 277 V AC General use
5 A 277 V AC General use
5 A 240 V AC General use
10 A 125 V AC General use
10 A 125 V AC General use
5 A
30 V DC General use
5 A
30 V DC General use
4 A 125 V AC Resistive
7 A 125 V AC Resistive
8.75 A 240 V AC Resistive
HP 277 V AC
HP 125 V AC
4 FLA/4 LRA 277 V AC
2 FLA/12 LRA 120 V AC
2.3 A 240 V AC Pilot Duty
1.5 A 125 V AC Pilot Duty
1 A 125 V AC Pilot Duty
1 A 240 V AC Pilot Duty
0.5 A 30 V DC Pilot Duty
2 A 120 V AC Tungsten
1 A 240 V AC Tungsten
6 × 10
40 ℃
40 ℃
85 ℃
105 ℃
40 ℃
85 ℃
40 ℃
85 ℃
105 ℃
75 ℃
85 ℃
40 ℃
40 ℃
105 ℃
105 ℃
75 ℃
80 ℃
105 ℃
105 ℃
75 ℃
105 ℃
75 ℃
10 A 277 V AC General use
5 A 277 V AC General use
100 × 10
5 A 277 V AC General use
10 A 125 V AC General use
10 A 125 V AC General use
5 A
30 V DC General use
100 × 10
5 A
30 V DC General use
5 A 240 V AC Resistive
HP 277 V AC
HP 125 V AC
4 FLA/
4 LRA 277 V AC
3 FLA/18 LRA 240 V AC
1 A 240 V AC Pilot Duty
3 A 120 V AC Pilot Duty
10 A 277 V AC General use
( Class F only )
3 A 125 V AC General use
100 × 10
2 A 277 V AC General use
100 × 10
1 A
30 V DC General use
100 × 10
2 A
30 V DC Resistive
3 A 240 V AC Resistive
2 A 120 V AC Pilot Duty
6 × 10
40 ℃
40 ℃
85 ℃
40 ℃
85 ℃
40 ℃
85 ℃
80 ℃
40 ℃
40 ℃
105 ℃
85 ℃
80 ℃
85 ℃
3
3
100 × 10
3
3
3
3
3
3
3
50 × 10
50 × 10
50 × 10
10 × 10
3
6 × 10
3
50 × 10
3
10 × 10
3
100 × 10
50 × 10
3
50 × 10
100 × 10
N.O.
3
1
1
3
100 × 10
/
6
10
3
3
100 × 10
/
6
10
3
3
3
3
3
100 × 10
100 × 10
100 × 10
100 × 10
100 × 10
E43028
1
3
/
/
6
10
10
1
3
6
3
100 × 10
3
6 × 10
E43028
3
6 × 10
105 ℃
3
3
3
3
3
3
3
6 × 10
100 × 10
100 × 10
100 × 10
100 × 10
6 × 10
3
3
3
3
3
3
85 ℃
85 ℃
85 ℃
40 ℃
80 ℃
80 ℃
N.C.
100 × 10
100 × 10
100 × 10
6 × 10
1.5 A 24 V AC Inductive
( pf 0.35 )
1 A 250 V AC Inductive
( pf 0.35 )
1.5 A 125 V AC Inductive
( pf 0.5 )
10 A 277 V AC General use
( Class F only )
3
3
3
3
500 × 10
500 × 10
500 × 10
6 × 10
25 ℃
25 ℃
25 ℃
105 ℃
* Pilot Duty comply with UL508 conditions
Inrush type / Reinforced insulation type ( 1 Form A )
Ambient
File No.
Contact rating
Operations
temperature
3
8 A 277 V AC General use
6 × 10
105 ℃
40 ℃
E43028
1
3
/
2
HP 250 V AC
10
Note) Inrush type/Reinforced insulation type, please contact our sales
representative for details.
■ CSA ( Approved )
CSA standard approved by C-UL
■ VDE ( Approved )
1 Form A ( ALQ 3** )
1 Form C ( ALQ 1** )
Ambient
Ambient
File No.
Contact rating
Operations
File No.
Contact
Contact rating
Operations
temperature
temperature
3
3
10 A 250 V AC ( cosφ = 1.0 )
10 A 250 V AC ( cosφ = 0.4 )
5 A 250 V AC ( cosφ = 1.0 )
5 A
30 V DC ( 0 ms )
10 × 10
10 × 10
85 ℃
85 ℃
85 ℃
85 ℃
10 A 250 V AC ( cosφ = 1.0 )
10 × 10
10 A 250 V AC ( cosφ = 0.4 )
10 × 10
5 A 250 V AC ( cosφ = 1.0 )
50 × 10
5 A
30 V DC ( 0 ms )
3 A 250 V AC ( cosφ = 0.4 )
10 × 10
85 ℃
85 ℃
85 ℃
85 ℃
85 ℃
3
3
3
3
3
40032836
N.O.
N.C.
3
50 × 10
40032836
3
10 × 10
10 × 10
Inrush type / Reinforced insulation type ( 1 Form A )
Ambient
File No.
Contact rating
Operations
temperature
3
40032836
8 A 250 V AC ( cosφ = 1.0 )
10
105 ℃
Note) Inrush type/Reinforced insulation type, please contact our sales
representative for details.
Panasonic Industry Co., Ltd. Electromechanical Control Business Division
industrial.panasonic.com/ac/e/
Panasonic Industry Co., Ltd. 2023
ASCTB92E 202306
ー 6 ー
Power Relays ( Over 2 A ) LQ RELAYS
■ TV rating
Inrush type / Reinforced insulation type ( 1 Form A )
File No.
Contact rating
E43028
TV-3
Note) Inrush type/Reinforced insulation type, please contact our sales
representative for details.
■ CQC ( Approved )
1 Form A ( ALQ 3** )
1 Form C ( ALQ 1** )
File No.
File No.
Contact rating
Contact
N.O.
N.C.
Contact rating
5 A 250 V AC
2 A 250 V AC
CQC14002108384
5 A 250 V AC
CQC14002108384
INSULATION CHARACTERISTICS ( IEC61810-1 )
Item
Characteristic
Clearance/Creepage distance ( IEC61810-1 ) *
Category of protection ( IEC61810-1 )
Tracking resistance ( IEC60112 )
Insulation material group
Min. 4.0/4.0 mm
RTIII
PTI 175
III a
Over voltage category
III
Rated voltage
250 V
Pollution degree
2
Type of insulation ( Between contact and coil )
Type of insulation ( Between open contacts )
Note) Actual value.
Basic insulation
Micro disconnection
* For Min. 5.5/5.5 mm ( Reinforced insulation ) , please contact our sales representative for details.
GUIDELINES FOR USAGE
■ For cautions for use, please read ” GUIDELINES FOR RELAY USAGE “.
Panasonic Industry Co., Ltd. Electromechanical Control Business Division
industrial.panasonic.com/ac/e/
Panasonic Industry Co., Ltd. 2023
ASCTB92E 202306
ー 7 ー
GUIDELINES FOR POWER, HIGH-CAPACITY DC CUT OFF AND SAFETY RELAYS USAGE
■ For cautions for use, please read ” GUIDELINES FOR RELAY USAGE “.
Precautions for Coil Input
■ Long term current carrying
■ Coil connection
A circuit that will be carrying a current continuously for
long periods without relay switching operation. ( circuits
for emergency lamps, alarm devices and error inspection
that, for example, revert only during malfunction and
output warnings with form B contacts ) Continuous, long-
term current to the coil will facilitate deterioration of coil
insulation and characteristics due to heating of the coil itself.
For circuits such as these, please use a magnetic-hold type
latching relay. If you need to use a single stable relay, use
a sealed type relay that is not easily affected by ambient
conditions and make a failsafe circuit design that considers
the possibility of contact failure or disconnection.
When connecting coils of polarized relays, please check coil
polarity ( +, - ) at the internal connection diagram
( Schematic ). If any wrong connection is made, it may
cause unexpected
malfunction, like abnormal heat, fire and
so on, and circuit do not work. Avoid impressing voltages to
the set coil and reset coil at the same time.
■ Maximum allowable voltage and temperature
rise
Proper usage requires that the rated coil voltage be
impressed on the coil. Note, however, that if a voltage
greater than or equal to the maximum continuous voltage
is impressed on the coil, the coil may burn or its layers short
due to the temperature rise. Furthermore, do not exceed the
usable ambient temperature range listed in the catalog.
■ DC Coil operating power
Steady state DC current should be applied to the coil. The
wave form should be rectangular. If it includes ripple, the
ripple factor should be less than 5 %.
●Operate voltage change due to coil temperature rise
In DC relays, after continuous passage of current in
the coil, if the current is turned OFF, then immediately
turned ON again, due to the temperature rise in the
coil, the operate voltage will become somewhat
higher. Also, it will be the same as using it in a higher
temperature atmosphere. The resistance/temperature
relationship for copper wire is about 0.4 % for 1 ℃,
and with this ratio the coil resistance increases. That
is, in order to operate of the relay, it is necessary that
the voltage be higher than the operate voltage and the
operate voltage rises in accordance with the increase
in the resistance value. However, for some polarized
relays, this rate of change is considerably smaller.
However, please check with the actual circuit since the
electrical characteristics may vary. The rated coil voltage
should be applied to the coil and the set/reset pulse time of
latching type relay differs for each relays, please refer to the
relay’s individual specifications.
Panasonic Industry Co., Ltd. Electromechanical Control Business Division
industrial.panasonic.com/ac/e/
Panasonic Industry Co., Ltd. 2023
ASCTB412E 202301
ー 8 ー
GUIDELINES FOR POWER, HIGH-CAPACITY DC CUT OFF AND SAFETY RELAYS USAGE
Ambient Environment
■ Usage, Transport, and Storage Conditions
During usage, storage, or transportation, avoid locations
subjected to direct sunlight and maintain normal
temperature, humidity and pressure conditions.
●Temperature/Humidity/Pressure
●Icing
Condensation or other moisture may freeze on relays
when the temperature become lower than 0 ℃.This
icing causes the sticking of movable portion, the
operation delay and the contact conduction failure etc.
Panasonic Industry Co., Ltd. does not guarantee the
failures caused by the icing.
The heat conduction by the equipment may accelerate
the cooling of relay itself and the icing may occur.
Please conduct product evaluations in the worst
condition of the actual usage.
When transporting or storing relays while they are tube
packaged, there are cases the temperature may differ
from the allowable range. In this case be sure to check
the individual specifications.
Also allowable humidity level is influenced by
temperature, please check charts shown below and
use relays within mentioned conditions. ( Allowable
temperature values differ for each relays, please refer
to the relay’s individual specifications. )
●Low temperature and low humidity
The plastic becomes brittle if the relay is exposed to a
low temperature, low humidity environment for long
periods of time.
1) Temperature:
The tolerance temperature range differs for
each relays, please refer to the relay’s individual
specifications
2) Humidity: 5 to 85 % RH
●High temperature and high humidity
Storage for extended periods of time ( including
transportation periods ) at high temperature or high
humidity levels or in atmospheres with organic gases
or sulfide gases may cause a sulfide film or oxide film
to form on the surfaces of the contacts and/or it may
interfere with the functions. Check out the atmosphere
in which the units are to be stored and transported.
Humidity (% RH)
85
Allowable range
Avoid icing
Avoid con-
when used at
temperatures
lower than 0
°
C
densation when
used at tem-
peratures higher
than 0
°
C
●Package
In terms of the packing format used, make every effort
to keep the effects of moisture, organic gases and
sulfide gases to the absolute minimum.
5
-40
0
85
Ambient temperature (℃)
3) Pressure: 86 to 106 kPa
●Silicon
When a source of silicone substances ( silicone rubber,
silicone oil, silicone coating materials and silicone filling
materials etc. ) is used around the relay, the silicone gas
( low molecular siloxane etc. ) may be produced.
This silicone gas may penetrate into the inside of the
relay. When the relay is kept and used in this condition,
silicone compound may adhere to the relay contacts
which may cause the contact failure. Do not use any
sources of silicone gas around the relay ( Including
plastic sealed types ).
●Dew condensation
Condensation occurs when the ambient temperature
drops suddenly from a high temperature and humidity,
or the relay is suddenly transferred from a low ambient
temperature to a high temperature and humidity.
Condensation causes the failures like insulation
deterioration, wire disconnection and rust etc.
Panasonic Industry Co., Ltd. does not guarantee the
failures caused by condensation.
The heat conduction by the equipment may accelerate
the cooling of device itself, and the condensation may
occur.
Please conduct product evaluations in the worst
condition of the actual usage. ( Special attention should
be paid when high temperature heating parts are close
to the device. Also please consider the condensation
may occur inside of the device. )
●NOx Generation
When relay is used in an atmosphere high in humidity
to switch a load which easily produces an arc, the NOx
created by the arc and the water absorbed from outside
the relay combine to produce nitric acid.
This corrodes the internal metal parts and adversely
affects operation.
Avoid use at an ambient humidity of 85 % RH or higher
( at 20 ℃ ). If use at high humidity is unavoidable,
please contact our sales representative.
Panasonic Industry Co., Ltd. Electromechanical Control Business Division
industrial.panasonic.com/ac/e/
Panasonic Industry Co., Ltd. 2023
ASCTB412E 202301
ー 9 ー
GUIDELINES FOR POWER, HIGH-CAPACITY DC CUT OFF AND SAFETY RELAYS USAGE
Others
■ Cleaning
• Cleaning
with the boiling method is recommended ( The
temperature of cleaning liquid should be 40 ℃ or lower ).
Avoid ultrasonic cleaning on relays. Use of ultrasonic
cleaning may cause breaks in the coil or slight sticking of
the contacts due to ultrasonic energy.
• Although
the environmentally sealed type relay ( plastic
sealed type, etc. ) can be cleaned, avoid immersing
the relay into cold liquid ( such as cleaning solvent )
immediately after soldering. Doing so may deteriorate the
sealing performance.
Please refer to
“the latest product specifications”
when designing your product.
•Requests to customers:
Panasonic Industry Co., Ltd. Electromechanical Control Business Division
Panasonic Industry Co., Ltd. 2023
ASCTB412E 202301
ー 10 ー
industrial.panasonic.com/ac/e/
■
Global Sales Network Information: industrial.panasonic.com/ac/e/salesnetwork
Electromechanical Control Business Division
1006, Oaza Kadoma, Kadoma-shi, Osaka 571-8506, Japan
industrial.panasonic.com/ac/e/
Specifications are subject to change without notice.
2023.6
©Panasonic Industry Co., Ltd. 2023
モヴヤヵャペビユチチチビパビピパプ