PANASONIC-APAN3105
| Part # | PANASONIC-APAN3105 |
| Download | PANASONIC-APAN3105 |
1 Form A 5A
slim power relay
complies with IEC61010
reinforced insulation
P
A
-N REL
A
Y
S
FEATURES
TYPICAL APPLICATIONS
w
Ne
1. High density mounting
5mm(W)
×
20mm(L)
×
12.5mm(H)
.197inch(W)
×
.787inch(L)
×
.492inch(H)
1. Output relays for programmable
controllers and temperature
controllers
2. Industrial equipment, office
equipment
2. Low operating power
Nominal operating power: 110mW
3. Complies with IEC61010 reinforced
insulation standards
3. Measuring devices and test
equipment
4. Long Insulation distance
• Clearance: 5.29mm
.208inch
Creepage distance: 5.35mm
.211inch
(Between contact and coil)
• 3,000 V breakdown voltage and
6,000V surge breakdown voltage
5. Complies with Standard for
Hazardous Location (ANSI/ISA
12.12.01)
RoHS compliant
Protective construction: Sealed type
(RTIII)
ORDERING INFORMATION
APAN 3
1
Contact arrangement
3: 1 Form A (Bifurcated)
Terminals and Nominal operating power
1: PC board terminal (110 mW)
Nominal coil voltage (DC)
03: 3V, 4H: 4.5V, 05: 5V, 06: 6V, 09: 9V, 12: 12V, 18: 18V, 24: 24V
Note: Certified by UL/C-UL and TÜV
TYPES
Contact arrangement
Nominal coil voltage
3 V DC
Part No.
A
P
A
N3103
A
P
A
N314H
A
P
A
N3105
A
P
A
N3106
A
P
A
N3109
A
P
A
N3112
A
P
A
N3118
A
P
A
N3124
4.5 V DC
5 V DC
6 V DC
1 Form A
9 V DC
12 V DC
18 V DC
24 V DC
Standard packing:
T
u
be: 25 pcs.; Case: 1,000 pcs.
*
T
e
rminal sockets available.
ASCTB368E 201604-T
–1–
P
A
-N (A
P
A
N3)
RATING
1. Coil data
Nominal operating
current
[ 10%]
(at 20
°
C
68
°
F
)
Nominal coil
voltage
Pick-up voltage
(at 20
°
C
68
°
F
)
Drop-out voltage
(at 20
°
C
68
°
F
)
Coil resistance
[ 10%]
(at 20
°
C
68
°
F
)
Nominal operating
power
Max. applied voltage
(at 20
°
C
68
°
F
)
3 V DC
4.5 V DC
5 V DC
36.7 mA
24.4 mA
22.0 mA
18.3 mA
12.2 mA
9.2 mA
82
Ω
184
Ω
227
Ω
327
Ω
736
Ω
1,309
Ω
2,945
Ω
5,236
Ω
70%V or less of
nominal voltage*
(Initial)
5%V or more of
nominal voltage*
(Initial)
6 V DC
120%V of
nominal voltage
110mW
9 V DC
12 V DC
18 V DC
24 V DC
6.1 mA
4.6 mA
Note: *Pulse drive (JIS C 5442)
2. Specifications
Characteristics
Item
Specifications
Arrangement
Contact resistance (Initial)
1 Form A (Bifurcated)
Contact
Max. 30 m
Ω
(By voltage drop 6 V DC 1A)
AgNi type + Au
Contact material
Nominal switching capacity (resistive load)
Max. switching power (resistive load)
Max. switching voltage
5 A 250 V AC, 5 A 30 V DC
1,250 VA, 150 W
250 V (AC), 110 V (DC) (0.4 A)
5 A (AC, DC)
Rating
Max. switching current
Nominal operating power
110 mW
Min. switching capacity (Reference value)*
1
1 mA 5 V DC
Insulation resistance (Initial)
Min. 1,000M
Ω
(at 500V DC) Measurement at same location as “Breakdown voltage” section.
1,000 Vrms for 1min. (Detection current: 10mA.)
Between open contacts
Between contact and coil
Breakdown voltage
(Initial)
3,000 Vrms for 1min. (Detection current: 10mA.)
Surge breakdown voltage (Initial)
(Between contacts and coil)*
2
Electrical
characteristics
6,000 V
Operate time (at nominal voltage) (at 20
°
C
68
°
F
)
Max. 10 ms (excluding contact bounce time)
Max. 5 ms (excluding contact bounce time and without diode)
(Initial)
Release time (at nominal voltage) (at 20
°
C
68
°
F
)
(Initial)
Functional
Shock resistance
Min. 147 m/s
2
(Half-wave pulse of sine wave: 11 ms; detection time: 10
μ
s.)
Min. 980 m/s
2
(Half-wave pulse of sine wave: 6 ms.)
10 to 55 Hz at double amplitude of 2.5 mm (Detection time: 10
μ
s.)
10 to 55 Hz at double amplitude of 3.5 mm
Destructive
Mechanical
characteristics
Functional
Vibration resistance
Destructive
Mechanical
Min. 2
×
10
7
(at 180 times/min.)
Min. 10
5
(3 A 250 V AC, 30 V DC, resistive load)
Expected life
Conditions
Electrical
Min. 5
×
10
4
(5 A 250 V AC, 30 V DC, resistive load) (at 20 times/min.)*
4
Ambient temperature: –40
°
C to 90
°
C
–40
°
F to 194
°
F
;
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
20 times/min. (at nominal switching capacity)*
4
Conditions for operation, transport and storage*
3
Max. operating speed
Unit weight
Approx. 3 g
.15 oz
Notes: *1. This value can change due to the switching frequenc
y
,
e
nvironmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load.
*2. Wave is standard shock voltage of
1.2
×
50
μ
s according to JEC-212-1981
*3. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage
conditions in NOTES.
*4. Operating frequency of 5 A 250 V AC is 6 times/min. (ON : OFF = 1 s : 9 s)
ASCTB368E 201604-T
–2–
P
A
-N (A
P
A
N3)
REFERENCE DATA
1. Max. switching capacity
2. Life curve
3. Coil temperature rise
T
e
sted sample: A
P
A
N3124, 6 pcs.
Measured portion: Inside the coil
Ambient temperature: 20
°
C
68
°
F
, 90
°
C
194
°
F
(No
contact current)
10
40
35
30
AC250V resistive load
DC30V resistive load
DC30V L/R=7ms
AC resistive load
5
100
50
40
30
20
10
5
25
5A (20
°
C)
3A (20
°
C)
0A (20
°
C)
DC resistive load
1
AC250V cos
φ
=0.4
20
15
0.4
0.1
0A (90
°
C)
10
5
0
1
1
10
100
1000
0.1
0.5
1
3
5
10
90
100 110 120 130 140 150
Coil applied voltage, %V
Contact voltage, V
Switching capacit
y
, A
4. Operate & release time
T
e
sted sample: A
P
A
N3124, 20 pcs.
Measured direction: Upright
5. Ambient temperature characteristics
T
e
sted sample: A
P
A
N3124, 6 pcs.
6. Malfunctional shock
T
e
sted sample: A
P
A
N3124, 6 pcs.
10.0
9.0
8.0
7.0
6.0
30
Deenergized
condition
Energized
condition
Y
1000
Drop-out voltage
20
800
600
X
Z
400
200
10
Pick-up voltage
Operate time
0
5.0
4.0
3.0
2.0
1.0
0.0
0
-60 -40 -20
0
20 40
60 80
100
Ambient
Max.
Ave.
Min.
-10
-20
-30
temperature,
°
C
Z’
X’
Y’
Z’
Y
Z
Release time
100 110
Max.
Ave.
Min.
X
Y’
X’
70
80
90
120 130
Coil applied voltage, %V
The CAD data of the products with a
CAD Data
mark can be downloaded from: http://industrial.panasonic.com/ac/e/
DIMENSIONS
(mm
inch
)
External dimensions
PC board pattern (Bottom view)
CAD Data
0.5
.020
1.2 dia.
.047 dia.
1 dia.
.039 dia.
1 dia.
.039 dia.
1.2
1.2 dia.
.047 dia.
.047
2.9
.114
2.54
.100
10.16
.400
5.08
.200
0.5
0.8
1.2
5.0
.197
.020
.031
.047
T
o
lerance: 0.1
.004
2.54
.100
10.16
.400
20
5.08
.200
1.1
.043
0.25
.010
Schematic (Bottom view)
.787
1
2
5
6
General tolerance:
0.3
.012
NO COM
Coil
ASCTB368E 201604-T
–3–
P
A
-N (A
P
A
N3)
SAFETY STANDARDS
UL/C-UL (Recognized)
TÜV (Certified)
Contact ratings
File No.
Contact ratings
T
e
mp.
Cycles
File No.
T
e
mp.
Cycles
E43149 5
A 250 V AC Resistive
5 A 250 V AC Resistive
40
°
C
104
°
F
90
°
C
194
°
F
40
°
C
104
°
F
90
°
C
194
°
F
40
°
C
104
°
F
40
°
C
104
°
F
40
°
C
104
°
F
5
×
10
4
B16 01 13461 348
5 A 250 V AC (cos
φ
=1.0)
5 A 250 V AC (cos
φ
=1.0)
5 A 30 V DC (0 ms)
40
°
C
104
°
F
90
°
C
194
°
F
40
°
C
104
°
F
90
°
C
194
°
F
40
°
C
104
°
F
40
°
C
104
°
F
5
×
10
4
10
4
10
4
5 A 30 V DC General use
5 A 30V DC, 3 A 250 V AC General use
3 A 250 V AC Resistive
3 A 30 V DC General use
B300, R300 Pilot duty
5
×
10
4
10
4
5
×
10
4
10
4
5 A 30 V DC (0 ms)
3 A 250 V AC (cos
φ
=1.0)
3 A 30 V DC (0 ms)
10
5
10
5
10
5
10
5
—
E479891 Class
I, Division 2, Groups A, B, C, D Hazardous Location
(ANSI/ISA 12.12.01-2015, CAN/CSA C22.2 No.213-15)
Insulation distance (between contact and coil)
• UL/C-UL: Clearance distance: 5.29 mm
.208 inch
, Creepage distance: 5.35 mm
.211 inch
• TÜV: Clearance distance: 5.29 mm
.208 inch
, Creepage distance: 5.35 mm
.211 inch
NOTES
1. For cautions for use, please read
“GENERAL APPLICATION
4. When mounting the relays within
1 mm
.039 inch
, please notice the
condition below.
GUIDELINES”.
2. If it includes ripple, the ripple factor
should be less than 5%.
1) Mount the relays in the same
direction.
3. Specification values for pick-up and
drop-out voltages are for the relay
mounting with its terminals below.
Within 1 mm
.039 inch
T
e
sted sample: A
P
A
N3124, 6 pcs.
Ambient temperature: 20
°
C
68
°
F
Measured direction: 6 direction
100
90
80
Pick-up voltage
70
2) Coil terminals (
T
e
rminal No. 1 & 2)
polarity should be arranged in the
same direction.
Max.
Ave.
Min.
60
50
40
30
20
10
0
Drop-out voltage
Max.
Ave.
Min.
–. –. –. –. –.
+. +. +. +. +.
+. +. +. +. +.
–. –. –. –. –.
Mounting