PANASONIC-DS2E-S-DC3V

Part #PANASONIC-DS2E-S-DC3V
Download 
PANASONIC-DS2E-S-DC3V
Automation Controls Catalog  
1 Form C / 2 Form C, 2 A,  
200 mW Nominal operating  
power relays  
DS RELAYS  
FEATURES  
TYPICAL APPLICATIONS  
1. 1 Form C / 2 Form C contact  
2. Available 2 coil latching type  
3. DIL terminal array enables use of IC  
sockets  
1. Telecommunications and  
measuring devices  
2.
Office equipment  
3.
Computers and related equipment  
4.
Industrial equipment  
ORDERING INFORMATION  
DS  
E
Contact arrangement  
1: 1 Form C  
2: 2 Form C  
M: Standard type  
S: High
 
sensitivity type  
Operating function  
Nil: Single side stable  
L2: 2 coil latching  
Nominal coil voltage  
DC 1.5, 3, 5, 6, 9, 12, 24, 48 V  
Note: * Nominal coil voltage 1.5V type are 1 Form C only.  
industrial.panasonic.com/ac/e/  
© Panasonic Corporation 2019  
ASCTB17E 201903  
2019.03  
1

DS  
TYPES  
High sensitivity type  
Standard type  
Single side stable type  
Contact  
arrangement  
Nominal coil  
voltage  
Single side stable type  
2 coil latching type  
Part No.  
2 coil latching type  
Part No.  
Part No.  
Part No.  
1.5 V DC  
DS1E-S-DC1.5V  
DS1E-S-DC3V  
DS1E-S-DC5V  
DS1E-S-DC6V  
DS1E-S-DC9V  
DS1E-S-DC12V  
DS1E-S-DC24V  
DS1E-S-DC48V  
DS2E-S-DC3V  
DS2E-S-DC5V  
DS2E-S-DC6V  
DS2E-S-DC9V  
DS2E-S-DC12V  
DS2E-S-DC24V  
DS2E-S-DC48V  
DS1E-SL2-DC1.5V  
DS1E-SL2-DC3V  
DS1E-SL2-DC5V  
DS1E-SL2-DC6V  
DS1E-SL2-DC9V  
DS1E-SL2-DC12V  
DS1E-SL2-DC24V  
DS1E-SL2-DC48V  
DS2E-SL2-DC3V  
DS2E-SL2-DC5V  
DS2E-SL2-DC6V  
DS2E-SL2-DC9V  
DS2E-SL2-DC12V  
DS2E-SL2-DC24V  
DS2E-SL2-DC48V  
DS1E-M-DC1.5V  
DS1E-ML2-DC1.5V  
3
5
6
9
V DC  
V DC  
V DC  
V DC  
DS1E-M-DC3V  
DS1E-ML2-DC3V  
DS1E-M-DC5V  
DS1E-ML2-DC5V  
DS1E-M-DC6V  
DS1E-ML2-DC6V  
1 Form C  
DS1E-M-DC9V  
DS1E-ML2-DC9V  
12 V
 
DC  
24 V
 
DC  
48 V
 
DC  
DS1E-M-DC12V  
DS1E-ML2-DC12V  
DS1E-M-DC24V  
DS1E-ML2-DC24V  
DS1E-M-DC48V  
DS1E-ML2-DC48V  
3
5
6
9
V DC  
V DC  
V DC  
V DC  
—
—
—
—
—
—
—
—
—
—
—
—
—
—
2 Form C  
12 V
 
DC  
24 V
 
DC  
48 V
 
DC  
Standard packing: Carton: 50 pcs.; Case: 500 pcs.  
RATING  
1.Coil data  
• Operating characteristics such as ‘Operate voltage’ and ‘Release voltage’ are influenced by mounting conditions, ambient  
temperature, etc.  
Therefore, please use the relay within ± 5% of rated coil voltage.  
• ‘Initial’ means the condition of products at the time of delivery.  
1) Single side stable type  
Nominal operating current  
Max. applied  
voltage  
(at 50°C
122°F
)  
Nominal coil
 
Pick-up voltage
 
Drop-out voltage  
Coil resistance[±10%]  
Nominal operating  
Type  
[±10%]  
(at 20°C
68°F
)  
voltage  
(at 20°C
68°F
)  
(at 20°C
68°F
)  
(at 20°C
68°F
)  
power  
1.5
V DC  
266.7 mA  
133.3 mA  
80.0 mA  
66.7 mA  
44.4 mA  
33.3 mA  
16.7 mA  
8.3 mA  
5.63 Ω  
22.5 Ω  
62.5 Ω  
3
5
6
9
V DC  
V DC  
V DC  
V DC  
70%V or less of
 
10%V or more of  
1 Form C:  
120%V of  
nominal voltage  
90  
203  
Ω
Ω
Ω
Ω
Ω
Standard  
(M) type  
nominal voltage  
nominal voltage  
400 mW  
(Initial)  
(Initial)  
12 V
 
DC  
24 V
 
DC  
48 V
 
DC  
1.5 V DC  
360  
1,440  
5,760  
133.3 mA  
66.7 mA  
40.0 mA  
33.3 mA  
22.2 mA  
16.7 mA  
8.3 mA  
11.3 Ω  
1 Form C:  
3
5
6
9
V DC  
V DC  
V DC  
V DC  
45  
125  
Ω
Ω
Ω
Ω
Ω
Ω
Ω
1 Form C:  
160%V of  
80%V or less of  
nominal voltage  
High  
10%V or more of  
nominal voltage  
(Initial)  
nominal voltage  
180  
sensitivity  
(S) type  
200 mW  
2 Form C:  
70%V or less of  
nominal voltage  
(Initial)  
405  
2 Form C:  
220%V of  
12 V
 
DC  
24 V
 
DC  
48 V
 
DC  
720  
nominal voltage  
2,880  
11,520  
4.2 mA  
2) 2 coil latching type  
Nominal operating  
current  
[±10%] (at 20°C
68°F
)  
Coil resistance  
[±10%] (at 20°C
68°F)  
Nominal operating  
power  
Max. applied  
voltage  
(at 50°C
122°F
)  
Nominal coil  
voltage  
Set voltage  
(at 20°C
68°F
)  
Reset voltage  
(at 20°C
68°F
)  
Type  
Set coil  
Reset coil  
240 mA  
120 mA  
72 mA  
60 mA  
40 mA  
30 mA  
15 mA  
7.5 mA  
Set coil  
6.25 Ω  
25  
69.4 Ω  
Reset coil  
Set coil
 
Reset coil  
1.5 V DC  
240 mA  
120 mA  
72 mA  
60 mA  
40 mA  
30 mA  
15 mA  
7.5 mA  
120 mA  
60 mA  
36 mA  
30 mA  
20 mA  
15 mA  
7.5 mA  
3.75 mA  
6.25 Ω  
3
5
6
9
V DC  
V DC  
V DC  
V DC  
Ω
25  
69.4  
100  
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
70%V or less of  
nominal voltage  
(Initial)  
70%V or less of  
nominal voltage  
(Initial)  
1 Form C:  
120%V of  
nominal voltage  
100  
Ω
Ω
Ω
Ω
Ω
Standard  
(M) type  
360 mW
 
360 mW  
225  
400  
225  
12 V
 
DC  
24 V
 
DC  
48 V
 
DC  
1.5 V DC  
400  
1,600  
6,400  
1,600  
6,400  
12.5  
50  
120 mA  
60 mA  
36 mA  
30 mA  
20 mA  
15 mA  
7.5 mA  
12.5 Ω  
1 Form C:  
80%V or less of  
nominal voltage  
1 Form C:  
80%V or less of  
nominal voltage  
3
5
6
9
V DC  
V DC  
V DC  
V DC  
50  
139  
Ω
Ω
Ω
Ω
Ω
Ω
Ω
1 Form C:  
160%V of  
nominal voltage  
139  
High  
sensitivity  
(S) type  
200  
200  
180 mW
 
180 mW  
2 Form C:  
70%V or less of  
nominal voltage  
(Initial)  
2 Form C:  
70%V or less of  
nominal voltage  
(Initial)  
450  
450  
2 Form C:  
220%V of  
nominal voltage  
12 V
 
DC  
24 V
 
DC  
48 V
 
DC  
800  
800  
3,200  
12,800  
3,200  
12,800  
3.75 mA  
Panasonic Corporation Electromechanical Control Business Division  
industrial.panasonic.com/ac/e/  
© Panasonic Corporation 2019  
ASCTB17E 201903  
2

DS  
2. Specifications  
Characteristics  
Item  
Specifications  
Arrangement  
1 Form C  
2 Form C  
Contact  
Initial contact resistance, max.  
Contact material  
Max. 50 mΩ (By voltage drop 6 V DC 1A)  
Ag + Au clad  
Nominal switching capacity  
Max. switching power  
2 A 30 V DC (resistive load)  
60 W, 125 VA (resistive load)  
220 V DC, 250 V AC  
3 A  
Max. switching voltage  
Max. carrying current  
Rating  
Min. switching capacity (Reference value)*

1  

10μA 10 mV DC  
Single side stable (M type: 400 mW, S type: 200 mW);  
latching (M type: 360 mW, S type: 180 mW)  
Nominal operating power  
Min. 100MΩ (at 500 V DC)  
Measurement at same location as “Initial breakdown voltage” section.  
Insulation resistance (Initial)  
1,000 Vrms for 1min.  
(500 Vrms for 1min: 1 Form C type) (Detection current: 10mA.)  
Between open contacts  
Breakdown voltage (Initial)  
T
e
mperature rise  
1,500 Vrms for 1min.  
(1,000 Vrms for 1min: 1 Form C type) (Detection current: 10mA.)  
Between contact and coil  
Electrical  
characteristics  
Max. 65°C  
(By resistive method, nominal coil voltage applied to the coil, contact carrying current: 2A.)  
Max. 10 ms [10 ms] (Nominal coil voltage applied to the coil, excluding contact bounce  
time.)  
Operate time [Set time] (at 20°C
68°F
)  
Release time [Reset time] (at 20°C
68°F
)  
Max. 5 ms [10 ms] (Nominal coil voltage applied to the coil, excluding contact bounce time.)  
(without diode)  
Functional*

2  

Shock resistance  
Min. 490 m/s

2  

Min. 490 m/s

2  

Destructive  
Min. 980 m/s

2

(Half-wave pulse of sine wave: 6 ms.)  
Mechanical  
characteristics  
Functional  
Vibration resistance  
10 to 55 Hz at double amplitude of 3.3 mm (Detection time: 10μs.)  
10 to 55 Hz at double amplitude of 5 mm  
Destructive  
Mechanical  
Electrical  
Min. 10

8

(10

7

: 1 Form C latching type) (at 600 cpm)  
Min. 5×10

5

rated load (at 60 cpm)  
Expected life  
Ambient temperature: –40°C to +70°C
–40°F to +158°F  
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)  
Conditions for operation, transport and storage*

3  

Max. operating speed (at rated load)  
Conditions  
60 cpm  
Unit weight  
Approx. 3g
 
.11 oz  
Approx. 4g
 
.14 oz  
Notes: *1
 
This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the  
actual load. TX/TX-S/TX-D relay AgPd contact type are available for low level load switching (10V DC, 10mA max. level).  
*2 Half-wave
 
pulse of sine wave: 11ms; detection time: 10μs  
*3 Refer
 
to “AMBIENT ENVIRONMENT” in GENERAL APPLICATION GUIDELINES.  
Panasonic Corporation Electromechanical Control Business Division  
industrial.panasonic.com/ac/e/  
© Panasonic Corporation 2019  
ASCTB17E 201903  
3

DS  
REFERENCE DATA  
1. Maximum switching capacity  
2. Life curve (Resistive load)  
3. Contact reliability for AC loads  
T
e
sted sample: DS2E-S-DC24V 10 pcs.  
Operating speed: 20 cpm.  
Detection level: 200 mΩ  
1,000V  
99.9  
99.0  
95.0  
1,000  
70.0  
50.0  
30 V DC  
100  
30.0  
100V  
10V  
10.0  
5.0  
125 V AC  
10  
2.0  
1.0  
0.5  
Weibull  
probability data  
0.2  
0.1  
10mV  
10A  
100mA  
1A  
0
1
2
0
10  
100
1
,
0
00  
No. of operations, ×10

4  

Switching current  
Switching current, A  
4. Operate and release time characteristics  
(2 Form C single side stable type)  
5-(1). Influence of adjacent mounting  
(1 Form C)  
5-(2). Influence of adjacent mounting  
(2 Form C)  
T
e
st condition: Without diode connected to coil in  
parallel  
4
Pick-up voltage  
(1) (2) (3)  
Pick-up voltage  
(1) (2) (3)  
OFF OFF  
OFF  
OFF  
10  
0
10  
0
3
ON  
ON  
ON  
ON  
Operate time (mean)  
–10  
–10  
2
OFF  
OFF  
OFF  
OFF  
Drop-out voltage  
Drop-out voltage  
Release time (mean)  
10  
0
10  
0
1
0
ON  
ON  
ON  
ON  
–10  
–10  
5
.197  
10  
.394  
5
.197  
10  
.394  
80  
100  
120  
Coil applied voltage, %  
Inter-relay distance
 
, mm
inch  
Inter-relay distance
 
, mm
inch  
(mm
inch
)  
The CAD data of the products with a
 
CAD Data
 

DIMENSIONS  
DS (1 Form C)  
Single side stable, 2 coil latching  
CAD Data  
External dimensions  
PC board pattern (Bottom view)  
Single side stable  
2 coil latching  
15  
.590  
9.9  
.390  
2.54  
.100  
2.54  
.100  
5-0.9 dia.  
5-.035 dia.  
6-0.9 dia.  
6-.035 dia.  
9.3  
.366  
2.54  
.100  
2.54  
.100  
0.6  
.024  
9.9  
.390  
3.4  
.134  
7.62  
.300  
7.62  
.300  
0.3  
.012  
0.6  
.024  
5.6  
5.08  
7.62  
.200  
.221  
.300  
7.62  
.300  
5.08  
.200  
7.62  
.300  
5.08  
.200  
7.62  
.300  
General tolerance:
 
±0.3
±.012  
Schematic (Bottom view)  
Single side stable  
2 coil latching  
1
3
6
1
6
12 10  
7
12 10  
7
(Deenergized condition)  
(Reset condition)  
T
o
lerance: ±0.1
±.004  
Panasonic Corporation Electromechanical Control Business Division  
industrial.panasonic.com/ac/e/  
© Panasonic Corporation 2019  
ASCTB17E 201903  
4

DS  
DS (2 Form C)  
Single side stable  
CAD Data  
External dimensions  
PC board pattern (Bottom view)  
20  
.780  
9.9  
.390  
2.54  
.100  
8-0.9 dia.  
8-.035 dia.  
2.54  
.100  
9.3  
.366  
0.6  
.024  
9.9  
.390  
7.62  
.300  
3.4  
.134  
0.3  
.012  
0.6  
.024  
5.6  
.221  
5.08 5.08  
.200 .200  
5.08 5.08  
.200 .200  
7.62  
.300  
7.62  
.300  
7.62  
.300  
Schematic (Bottom view)  
General tolerance:
 
±0.3
±.012  
9
11  
13  
16  
8
6
4
1
(Deenergized condition)  
T
o
lerance: ±0.1
±.004  
DS (2 Form C)  
2 coil latching  
CAD Data  
External dimensions  
PC board pattern (Bottom view)  
20  
.780  
9.9  
.390  
2.54  
.100  
10-0.9 dia.  
10-.035 dia.  
2.54  
.100  
9.3  
.366  
0.6  
.024  
9.9  
.390  
7.62  
.300  
3.4  
.134  
0.3  
.012  
0.6  
.024  
5.6  
.221  
5.08 5.08 5.08  
.200 .200 .200  
2.54  
.100  
5.08 5.08 5.08  
.200 .200 .200  
7.62  
.300  
2.54  
.100  
Schematic (Bottom view)  
General tolerance:
 
±0.3
±.012  
9
11  
13 15
 
16  
8
6
4
1
2
(Reset condition)  
T
o
lerance: ±0.1
±.004  
NOTES  
1. Coil connection  
When connecting coils, refer to the wiring  
diagram to prevent mis-operation or  
malfunction.  
Panasonic Corporation Electromechanical Control Business Division  
industrial.panasonic.com/ac/e/  
© Panasonic Corporation 2019  
ASCTB17E 201903  
5

DS  
Ambient Environment  
Usage, Transport, and Storage Conditions  
During usage, storage, or transportation, avoid locations subjected  
to direct sunlight and maintain normal temperature, humidity and  
pressure conditions.  
Temperature/Humidity  
When transporting or storing relays while they are tube  
packaged, there are cases the temperature may differ  
from the allowable range. In this case be sure to check the  
individual specifications.  
Also allowable humidity level is influenced by temperature,  
please check charts shown below and use relays within  
mentioned conditions. (Allowable temperature values)  
Humidity (%RH)  
85  
Allowable range  
Avoid con-  
Avoid icing  
densation when  
used at tem-  
peratures higher  
than 0
℃
 
when used at  
temperatures  
lower than 0
℃  
5
-40  
0
70  
Temperature(
°C)  
Please refer to
“the latest product specifications”  
when designing your product.  
• Requests to customers :  
Panasonic Corporation Electromechanical Control Business Division  
industrial.panasonic.com/ac/e/  
© Panasonic Corporation 2019  
ASCTB17E 201903  
6

GUIDELINES FOR SIGNAL REL
A
Y
S USAGE  
For cautions for use, please read “GUIDELINES FOR REL
A
Y
U
SAGE”.  
Precautions for Coil Input  
Temperature rise due to pulse voltage  
Long term current carrying  
A circuit that will be carrying a current continuously for long periods  
without relay switching operation. (circuits for emergency lamps, alarm  
devices and error inspection that, for example, revert only during  
malfunction and output warnings with form B contacts) Continuous,  
long-term current to the coil will facilitate deterioration of coil insulation  
and characteristics due to heating of the coil itself.  
When a pulse voltage with ON time of less than 2 minutes is used, the  
coil temperature rise bares no relationship to the ON time. This varies  
with the ratio of ON time to OFF time, and compared with continuous  
current passage, it is rather small. The various relays are essentially  
the same in this respect.  
Current passage time  
(%)  
For circuits such as these, please use a magnetic-hold type latching  
relay. If you need to use a single stable relay, use a sealed type relay  
that is not easily affected by ambient conditions and make a failsafe  
circuit design that considers the possibility of contact failure or  
disconnection.  
For continuousu passage  
T
e
mpereture rise value is
100
%  
ON : OFF =  
ON : OFF =  
ON : OFF =  
3
1
1
:
:
:
1
1
3
About
80  
About
50  
About
35  
%
%
%
DC Coil operating power  
ON : OFF = 1 : 1  
Steady state DC current should be applied to the coil. The wave form  
should be rectangular. If it includes ripple, the ripple factor should be  
less than 5%.  
However, please check with the actual circuit since the electrical  
characteristics may vary. The rated coil voltage should be applied to  
the coil and the set/reset pulse time of latching type relay differs for  
each relays, please refer to the relay’s individual specifications.  
Time  
Coil connection  
Operate voltage change due to coil temperature rise  
(Hot start)  
In DC relays, after continuous passage of current in the coil, if the  
ꢀ
When connecting coils of polarized relays, please check coil polarity  
(+,-) at the internal connection diagram (Schematic). If any wrong  
connection is made, it may cause unexpected malfunction, like  
abnormal heat, fire and so on, and circuit do not work. Avoid  
impressing voltages to the set coil and reset coil at the same time.  
ꢀ
current is turned OF
F
,
t
hen immediately turned ON again, due to the  
temperature rise in the coil, the pick-up voltage will become somewhat  
higher. Also, it will be the same as using it in a higher temperature  
atmosphere. The resistance/temperature relationship for copper wire  
is about 0.4% for 1°C, and with this ratio the coil resistance increases.  
That is, in order to operate of the relay, it is necessary that the voltage  
be higher than the pick-up voltage and the pick-up voltage rises in  
accordance with the increase in the resistance value. However, for  
some polarized relays, this rate of change is considerably smaller.  
Maximum allowable voltage and temperature rise  
Proper usage requires that the rated coil voltage be impressed on the  
coil. Note, however, that if a voltage greater than or equal to the  
maximum continuous voltage is impressed on the coil, the coil may  
burn or its layers short due to the temperature rise. Furthermore, do  
not exceed the usable ambient temperature range listed in the catalog.  
Maximum allowable voltage for coil  
In addition to being a requirement for relay operation stability, the  
maximum continuous impressed coil voltage is an important constraint  
for the prevention of such problems as thermal deterioration or  
deformity of the insulation material, or the occurrence of fire hazards.  
Panasonic Corporation Electromechanical Control Business Division  
industrial.panasonic.com/ac/e/  
c
Panasonic Corporation 2019  
ASCTB414E 201906  

GUIDELINES FOR SIGNAL RELAYS USAGE  
Ambient Environment  
Dew condensation  
2) If relays will not be used within 72 hours, please store relays in a  
humidity controlled desiccator or in an anti-humidity bag to which  
silica gel has been added.  
Condensation occurs when the ambient temperature drops suddenly  
from a high temperature and humidity, or the relay and microwave  
device is suddenly transferred from a low ambient temperature to a  
high temperature and humidity. Condensation causes the failures like  
insulation deterioration, wire disconnection and rust etc.  
Panasonic Corporation does not guarantee the failures caused by  
condensation.  
*If the relay is to be soldered after it has been exposed to excessive  
humidity atmosphere, cracks and leaks can occur. Be sure to mount  
the relay under the required mounting conditions  
3) The following cautionary label is affixed to the anti-humidity pack.  
The heat conduction by the equipment may accelerate the cooling of  
device itself, and the condensation may occur.  
Please conduct product evaluations in the worst condition of the actual  
usage. (Special attention should be paid when high temperature  
heating parts are close to the device. Also please consider the  
condensation may occur inside of the device.)  
Icing  
Condensation or other moisture may freeze on relays when the  
temperature become lower than 0°C.This icing causes the sticking of  
movable portion, the operation delay and the contact conduction failure  
etc. Panasonic Corporation does not guarantee the failures caused by  
the icing.  
The heat conduction by the equipment may accelerate the cooling of  
relay itself and the icing may occur. Please conduct product  
evaluations in the worst condition of the actual usage.  
Low temperature and low humidity  
Silicon  
When a source of silicone substances (silicone rubber, silicone oil,  
silicone coating materials and silicone filling materials etc.) is used  
around the relay, the silicone gas (low molecular siloxane etc.) may be  
produced.  
The plastic becomes brittle if the switch is exposed to a low  
temperature, low humidity environment for long periods of time.  
High temperature and high humidity  
This silicone gas may penetrate into the inside of the relay. When the  
relay is kept and used in this condition, silicone compound may adhere  
to the relay contacts which may cause the contact failure. Do not use  
any sources of silicone gas around the relay (Including plastic seal  
types).  
Storage for extended periods of time (including transportation periods)  
at high temperature or high humidity levels or in atmospheres with  
organic gases or sulfide gases may cause a sulfide film or oxide film to  
form on the surfaces of the contacts and/or it may interfere with the  
functions. Check out the atmosphere in which the units are to be  
stored and transported.  
NOx Generation  
When relay is used in an atmosphere high in humidity to switch a load  
which easily produces an arc, the NOx created by the arc and the  
water absorbed from outside the relay combine to produce nitric acid.  
This corrodes the internal metal parts and adversely affects operation.  
Avoid use at an ambient humidity of 85% RH or higher (at 20°C). If use  
at high humidity is unavoidable, please contact our sales  
representative.  
Package  
In terms of the packing format used, make every effort to keep the  
effects of moisture, organic gases and sulfide gases to the absolute  
minimum.  
Storage requirements  
Since the SMD type is sensitive to humidity it is packaged with tightly  
sealed anti-humidity packaging. However, when storing, please be  
careful of the following.  
1) Please use promptly once the anti-humidity pack is opened.(Signal  
relay: within 72 hours, Max. 30°C/70% RH). If left with the pack  
open, the relay will absorb moisture which will cause thermal stress  
when reflow mounting and thus cause the case to expand. As a  
result, the seal may break.  
Others  
Cleaning  
1) Although the environmentally sealed type relay (plastic sealed type,  
etc.) can be cleaned, avoid immersing the relay into cold liquid (such  
as cleaning solvent) immediately after soldering. Doing so may  
deteriorate the sealing performance.  
3) Cleaning with the boiling method is recommended (The temperature  
of cleaning liquid should be 40°C or lower).  
Avoid ultrasonic cleaning on relays. Use of ultrasonic cleaning may  
cause breaks in the coil or slight sticking of the contacts due to the  
ultrasonic energy.  
2) Surface mount terminal type relay is sealed type and it can be  
cleaned by immersion. Use pure water or alcohol-based cleaning  
solvent.  
Please refer to
“the latest product specifications”  
when designing your product.  
•Requests to customers:  
Panasonic Corporation Electromechanical Control Business Division  
industrial.panasonic.com/ac/e/  
c
Panasonic Corporation 2019  
ASCTB414E 201906  

Please contact ……….  
Electromechanical Control Business Division  
1006, Oaza Kadoma, Kadoma-shi, Osaka 571-8506, Japan  
industral.panasonic.com/ac/e/  
©Panasonic Corporation 2019  
Specifications are subject to change without notice.  
ASCTB17E 201907