Automation Controls Catalog
1 Form C / 2 Form C, 2 A,
200 mW Nominal operating
power relays
DS RELAYS
FEATURES
TYPICAL APPLICATIONS
1. 1 Form C / 2 Form C contact
2. Available 2 coil latching type
3. DIL terminal array enables use of IC
sockets
1. Telecommunications and
measuring devices
2.
Office equipment
3.
Computers and related equipment
4.
Industrial equipment
ORDERING INFORMATION
DS
E
Contact arrangement
1: 1 Form C
2: 2 Form C
M: Standard type
S: High
sensitivity type
Operating function
Nil: Single side stable
L2: 2 coil latching
Nominal coil voltage
DC 1.5, 3, 5, 6, 9, 12, 24, 48 V
Note: * Nominal coil voltage 1.5V type are 1 Form C only.
industrial.panasonic.com/ac/e/
© Panasonic Corporation 2019
ASCTB17E 201903
2019.03
1
DS
TYPES
High sensitivity type
Standard type
Single side stable type
Contact
arrangement
Nominal coil
voltage
Single side stable type
2 coil latching type
Part No.
2 coil latching type
Part No.
Part No.
Part No.
1.5 V DC
DS1E-S-DC1.5V
DS1E-S-DC3V
DS1E-S-DC5V
DS1E-S-DC6V
DS1E-S-DC9V
DS1E-S-DC12V
DS1E-S-DC24V
DS1E-S-DC48V
DS2E-S-DC3V
DS2E-S-DC5V
DS2E-S-DC6V
DS2E-S-DC9V
DS2E-S-DC12V
DS2E-S-DC24V
DS2E-S-DC48V
DS1E-SL2-DC1.5V
DS1E-SL2-DC3V
DS1E-SL2-DC5V
DS1E-SL2-DC6V
DS1E-SL2-DC9V
DS1E-SL2-DC12V
DS1E-SL2-DC24V
DS1E-SL2-DC48V
DS2E-SL2-DC3V
DS2E-SL2-DC5V
DS2E-SL2-DC6V
DS2E-SL2-DC9V
DS2E-SL2-DC12V
DS2E-SL2-DC24V
DS2E-SL2-DC48V
DS1E-M-DC1.5V
DS1E-ML2-DC1.5V
3
5
6
9
V DC
V DC
V DC
V DC
DS1E-M-DC3V
DS1E-ML2-DC3V
DS1E-M-DC5V
DS1E-ML2-DC5V
DS1E-M-DC6V
DS1E-ML2-DC6V
1 Form C
DS1E-M-DC9V
DS1E-ML2-DC9V
12 V
DC
24 V
DC
48 V
DC
DS1E-M-DC12V
DS1E-ML2-DC12V
DS1E-M-DC24V
DS1E-ML2-DC24V
DS1E-M-DC48V
DS1E-ML2-DC48V
3
5
6
9
V DC
V DC
V DC
V DC
—
—
—
—
—
—
—
—
—
—
—
—
—
—
2 Form C
12 V
DC
24 V
DC
48 V
DC
Standard packing: Carton: 50 pcs.; Case: 500 pcs.
RATING
1.Coil data
• Operating characteristics such as ‘Operate voltage’ and ‘Release voltage’ are influenced by mounting conditions, ambient
temperature, etc.
Therefore, please use the relay within ± 5% of rated coil voltage.
• ‘Initial’ means the condition of products at the time of delivery.
1) Single side stable type
Nominal operating current
Max. applied
voltage
(at 50°C
122°F
)
Nominal coil
Pick-up voltage
Drop-out voltage
Coil resistance[±10%]
Nominal operating
Type
[±10%]
(at 20°C
68°F
)
voltage
(at 20°C
68°F
)
(at 20°C
68°F
)
(at 20°C
68°F
)
power
1.5
V DC
266.7 mA
133.3 mA
80.0 mA
66.7 mA
44.4 mA
33.3 mA
16.7 mA
8.3 mA
5.63 Ω
22.5 Ω
62.5 Ω
3
5
6
9
V DC
V DC
V DC
V DC
70%V or less of
10%V or more of
1 Form C:
120%V of
nominal voltage
90
203
Ω
Ω
Ω
Ω
Ω
Standard
(M) type
nominal voltage
nominal voltage
400 mW
(Initial)
(Initial)
12 V
DC
24 V
DC
48 V
DC
1.5 V DC
360
1,440
5,760
133.3 mA
66.7 mA
40.0 mA
33.3 mA
22.2 mA
16.7 mA
8.3 mA
11.3 Ω
1 Form C:
3
5
6
9
V DC
V DC
V DC
V DC
45
125
Ω
Ω
Ω
Ω
Ω
Ω
Ω
1 Form C:
160%V of
80%V or less of
nominal voltage
High
10%V or more of
nominal voltage
(Initial)
nominal voltage
180
sensitivity
(S) type
200 mW
2 Form C:
70%V or less of
nominal voltage
(Initial)
405
2 Form C:
220%V of
12 V
DC
24 V
DC
48 V
DC
720
nominal voltage
2,880
11,520
4.2 mA
2) 2 coil latching type
Nominal operating
current
[±10%] (at 20°C
68°F
)
Coil resistance
[±10%] (at 20°C
68°F)
Nominal operating
power
Max. applied
voltage
(at 50°C
122°F
)
Nominal coil
voltage
Set voltage
(at 20°C
68°F
)
Reset voltage
(at 20°C
68°F
)
Type
Set coil
Reset coil
240 mA
120 mA
72 mA
60 mA
40 mA
30 mA
15 mA
7.5 mA
Set coil
6.25 Ω
25
69.4 Ω
Reset coil
Set coil
Reset coil
1.5 V DC
240 mA
120 mA
72 mA
60 mA
40 mA
30 mA
15 mA
7.5 mA
120 mA
60 mA
36 mA
30 mA
20 mA
15 mA
7.5 mA
3.75 mA
6.25 Ω
3
5
6
9
V DC
V DC
V DC
V DC
Ω
25
69.4
100
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
70%V or less of
nominal voltage
(Initial)
70%V or less of
nominal voltage
(Initial)
1 Form C:
120%V of
nominal voltage
100
Ω
Ω
Ω
Ω
Ω
Standard
(M) type
360 mW
360 mW
225
400
225
12 V
DC
24 V
DC
48 V
DC
1.5 V DC
400
1,600
6,400
1,600
6,400
12.5
50
120 mA
60 mA
36 mA
30 mA
20 mA
15 mA
7.5 mA
12.5 Ω
1 Form C:
80%V or less of
nominal voltage
1 Form C:
80%V or less of
nominal voltage
3
5
6
9
V DC
V DC
V DC
V DC
50
139
Ω
Ω
Ω
Ω
Ω
Ω
Ω
1 Form C:
160%V of
nominal voltage
139
High
sensitivity
(S) type
200
200
180 mW
180 mW
2 Form C:
70%V or less of
nominal voltage
(Initial)
2 Form C:
70%V or less of
nominal voltage
(Initial)
450
450
2 Form C:
220%V of
nominal voltage
12 V
DC
24 V
DC
48 V
DC
800
800
3,200
12,800
3,200
12,800
3.75 mA
Panasonic Corporation Electromechanical Control Business Division
industrial.panasonic.com/ac/e/
© Panasonic Corporation 2019
ASCTB17E 201903
2
DS
2. Specifications
Characteristics
Item
Specifications
Arrangement
1 Form C
2 Form C
Contact
Initial contact resistance, max.
Contact material
Max. 50 mΩ (By voltage drop 6 V DC 1A)
Ag + Au clad
Nominal switching capacity
Max. switching power
2 A 30 V DC (resistive load)
60 W, 125 VA (resistive load)
220 V DC, 250 V AC
3 A
Max. switching voltage
Max. carrying current
Rating
Min. switching capacity (Reference value)*
1
10μA 10 mV DC
Single side stable (M type: 400 mW, S type: 200 mW);
latching (M type: 360 mW, S type: 180 mW)
Nominal operating power
Min. 100MΩ (at 500 V DC)
Measurement at same location as “Initial breakdown voltage” section.
Insulation resistance (Initial)
1,000 Vrms for 1min.
(500 Vrms for 1min: 1 Form C type) (Detection current: 10mA.)
Between open contacts
Breakdown voltage (Initial)
T
e
mperature rise
1,500 Vrms for 1min.
(1,000 Vrms for 1min: 1 Form C type) (Detection current: 10mA.)
Between contact and coil
Electrical
characteristics
Max. 65°C
(By resistive method, nominal coil voltage applied to the coil, contact carrying current: 2A.)
Max. 10 ms [10 ms] (Nominal coil voltage applied to the coil, excluding contact bounce
time.)
Operate time [Set time] (at 20°C
68°F
)
Release time [Reset time] (at 20°C
68°F
)
Max. 5 ms [10 ms] (Nominal coil voltage applied to the coil, excluding contact bounce time.)
(without diode)
Functional*
2
Shock resistance
Min. 490 m/s
2
Min. 490 m/s
2
Destructive
Min. 980 m/s
2
(Half-wave pulse of sine wave: 6 ms.)
Mechanical
characteristics
Functional
Vibration resistance
10 to 55 Hz at double amplitude of 3.3 mm (Detection time: 10μs.)
10 to 55 Hz at double amplitude of 5 mm
Destructive
Mechanical
Electrical
Min. 10
8
(10
7
: 1 Form C latching type) (at 600 cpm)
Min. 5×10
5
rated load (at 60 cpm)
Expected life
Ambient temperature: –40°C to +70°C
–40°F to +158°F
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Conditions for operation, transport and storage*
3
Max. operating speed (at rated load)
Conditions
60 cpm
Unit weight
Approx. 3g
.11 oz
Approx. 4g
.14 oz
Notes: *1
This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load. TX/TX-S/TX-D relay AgPd contact type are available for low level load switching (10V DC, 10mA max. level).
*2 Half-wave
pulse of sine wave: 11ms; detection time: 10μs
*3 Refer
to “AMBIENT ENVIRONMENT” in GENERAL APPLICATION GUIDELINES.
Panasonic Corporation Electromechanical Control Business Division
industrial.panasonic.com/ac/e/
© Panasonic Corporation 2019
ASCTB17E 201903
3
DS
REFERENCE DATA
1. Maximum switching capacity
2. Life curve (Resistive load)
3. Contact reliability for AC loads
T
e
sted sample: DS2E-S-DC24V 10 pcs.
Operating speed: 20 cpm.
Detection level: 200 mΩ
1,000V
99.9
99.0
95.0
1,000
70.0
50.0
30 V DC
100
30.0
100V
10V
10.0
5.0
125 V AC
10
2.0
1.0
0.5
Weibull
probability data
0.2
0.1
10mV
10A
100mA
1A
0
1
2
0
10
100
1
,
0
00
No. of operations, ×10
4
Switching current
Switching current, A
4. Operate and release time characteristics
(2 Form C single side stable type)
5-(1). Influence of adjacent mounting
(1 Form C)
5-(2). Influence of adjacent mounting
(2 Form C)
T
e
st condition: Without diode connected to coil in
parallel
4
Pick-up voltage
(1) (2) (3)
Pick-up voltage
(1) (2) (3)
OFF OFF
OFF
OFF
10
0
10
0
3
ON
ON
ON
ON
Operate time (mean)
–10
–10
2
OFF
OFF
OFF
OFF
Drop-out voltage
Drop-out voltage
Release time (mean)
10
0
10
0
1
0
ON
ON
ON
ON
–10
–10
5
.197
10
.394
5
.197
10
.394
80
100
120
Coil applied voltage, %
Inter-relay distance
, mm
inch
Inter-relay distance
, mm
inch
(mm
inch
)
The CAD data of the products with a
CAD Data
mark can be downloaded from https://industrial.panasonic.com/ac/e/
DIMENSIONS
DS (1 Form C)
Single side stable, 2 coil latching
CAD Data
External dimensions
PC board pattern (Bottom view)
Single side stable
2 coil latching
15
.590
9.9
.390
2.54
.100
2.54
.100
5-0.9 dia.
5-.035 dia.
6-0.9 dia.
6-.035 dia.
9.3
.366
2.54
.100
2.54
.100
0.6
.024
9.9
.390
3.4
.134
7.62
.300
7.62
.300
0.3
.012
0.6
.024
5.6
5.08
7.62
.200
.221
.300
7.62
.300
5.08
.200
7.62
.300
5.08
.200
7.62
.300
General tolerance:
±0.3
±.012
Schematic (Bottom view)
Single side stable
2 coil latching
1
3
6
1
6
12 10
7
12 10
7
(Deenergized condition)
(Reset condition)
T
o
lerance: ±0.1
±.004
Panasonic Corporation Electromechanical Control Business Division
industrial.panasonic.com/ac/e/
© Panasonic Corporation 2019
ASCTB17E 201903
4
DS
DS (2 Form C)
Single side stable
CAD Data
External dimensions
PC board pattern (Bottom view)
20
.780
9.9
.390
2.54
.100
8-0.9 dia.
8-.035 dia.
2.54
.100
9.3
.366
0.6
.024
9.9
.390
7.62
.300
3.4
.134
0.3
.012
0.6
.024
5.6
.221
5.08 5.08
.200 .200
5.08 5.08
.200 .200
7.62
.300
7.62
.300
7.62
.300
Schematic (Bottom view)
General tolerance:
±0.3
±.012
9
11
13
16
8
6
4
1
(Deenergized condition)
T
o
lerance: ±0.1
±.004
DS (2 Form C)
2 coil latching
CAD Data
External dimensions
PC board pattern (Bottom view)
20
.780
9.9
.390
2.54
.100
10-0.9 dia.
10-.035 dia.
2.54
.100
9.3
.366
0.6
.024
9.9
.390
7.62
.300
3.4
.134
0.3
.012
0.6
.024
5.6
.221
5.08 5.08 5.08
.200 .200 .200
2.54
.100
5.08 5.08 5.08
.200 .200 .200
7.62
.300
2.54
.100
Schematic (Bottom view)
General tolerance:
±0.3
±.012
9
11
13 15
16
8
6
4
1
2
(Reset condition)
T
o
lerance: ±0.1
±.004
NOTES
1. Coil connection
When connecting coils, refer to the wiring
diagram to prevent mis-operation or
malfunction.
Panasonic Corporation Electromechanical Control Business Division
industrial.panasonic.com/ac/e/
© Panasonic Corporation 2019
ASCTB17E 201903
5
DS
Ambient Environment
Usage, Transport, and Storage Conditions
During usage, storage, or transportation, avoid locations subjected
to direct sunlight and maintain normal temperature, humidity and
pressure conditions.
Temperature/Humidity
When transporting or storing relays while they are tube
packaged, there are cases the temperature may differ
from the allowable range. In this case be sure to check the
individual specifications.
Also allowable humidity level is influenced by temperature,
please check charts shown below and use relays within
mentioned conditions. (Allowable temperature values)
Humidity (%RH)
85
Allowable range
Avoid con-
Avoid icing
densation when
used at tem-
peratures higher
than 0
℃
when used at
temperatures
lower than 0
℃
5
-40
0
70
Temperature(
°C)
Please refer to
“the latest product specifications”
when designing your product.
• Requests to customers :
Panasonic Corporation Electromechanical Control Business Division
industrial.panasonic.com/ac/e/
© Panasonic Corporation 2019
ASCTB17E 201903
6
GUIDELINES FOR SIGNAL REL
A
Y
S USAGE
For cautions for use, please read “GUIDELINES FOR REL
A
Y
U
SAGE”.
Precautions for Coil Input
Temperature rise due to pulse voltage
Long term current carrying
A circuit that will be carrying a current continuously for long periods
without relay switching operation. (circuits for emergency lamps, alarm
devices and error inspection that, for example, revert only during
malfunction and output warnings with form B contacts) Continuous,
long-term current to the coil will facilitate deterioration of coil insulation
and characteristics due to heating of the coil itself.
When a pulse voltage with ON time of less than 2 minutes is used, the
coil temperature rise bares no relationship to the ON time. This varies
with the ratio of ON time to OFF time, and compared with continuous
current passage, it is rather small. The various relays are essentially
the same in this respect.
Current passage time
(%)
For circuits such as these, please use a magnetic-hold type latching
relay. If you need to use a single stable relay, use a sealed type relay
that is not easily affected by ambient conditions and make a failsafe
circuit design that considers the possibility of contact failure or
disconnection.
For continuousu passage
T
e
mpereture rise value is
100
%
ON : OFF =
ON : OFF =
ON : OFF =
3
1
1
:
:
:
1
1
3
About
80
About
50
About
35
%
%
%
DC Coil operating power
ON : OFF = 1 : 1
Steady state DC current should be applied to the coil. The wave form
should be rectangular. If it includes ripple, the ripple factor should be
less than 5%.
However, please check with the actual circuit since the electrical
characteristics may vary. The rated coil voltage should be applied to
the coil and the set/reset pulse time of latching type relay differs for
each relays, please refer to the relay’s individual specifications.
Time
Coil connection
Operate voltage change due to coil temperature rise
(Hot start)
In DC relays, after continuous passage of current in the coil, if the
ꢀ
When connecting coils of polarized relays, please check coil polarity
(+,-) at the internal connection diagram (Schematic). If any wrong
connection is made, it may cause unexpected malfunction, like
abnormal heat, fire and so on, and circuit do not work. Avoid
impressing voltages to the set coil and reset coil at the same time.
ꢀ
current is turned OF
F
,
t
hen immediately turned ON again, due to the
temperature rise in the coil, the pick-up voltage will become somewhat
higher. Also, it will be the same as using it in a higher temperature
atmosphere. The resistance/temperature relationship for copper wire
is about 0.4% for 1°C, and with this ratio the coil resistance increases.
That is, in order to operate of the relay, it is necessary that the voltage
be higher than the pick-up voltage and the pick-up voltage rises in
accordance with the increase in the resistance value. However, for
some polarized relays, this rate of change is considerably smaller.
Maximum allowable voltage and temperature rise
Proper usage requires that the rated coil voltage be impressed on the
coil. Note, however, that if a voltage greater than or equal to the
maximum continuous voltage is impressed on the coil, the coil may
burn or its layers short due to the temperature rise. Furthermore, do
not exceed the usable ambient temperature range listed in the catalog.
Maximum allowable voltage for coil
In addition to being a requirement for relay operation stability, the
maximum continuous impressed coil voltage is an important constraint
for the prevention of such problems as thermal deterioration or
deformity of the insulation material, or the occurrence of fire hazards.
Panasonic Corporation Electromechanical Control Business Division
industrial.panasonic.com/ac/e/
c
Panasonic Corporation 2019
ASCTB414E 201906
GUIDELINES FOR SIGNAL RELAYS USAGE
Ambient Environment
Dew condensation
2) If relays will not be used within 72 hours, please store relays in a
humidity controlled desiccator or in an anti-humidity bag to which
silica gel has been added.
Condensation occurs when the ambient temperature drops suddenly
from a high temperature and humidity, or the relay and microwave
device is suddenly transferred from a low ambient temperature to a
high temperature and humidity. Condensation causes the failures like
insulation deterioration, wire disconnection and rust etc.
Panasonic Corporation does not guarantee the failures caused by
condensation.
*If the relay is to be soldered after it has been exposed to excessive
humidity atmosphere, cracks and leaks can occur. Be sure to mount
the relay under the required mounting conditions
3) The following cautionary label is affixed to the anti-humidity pack.
The heat conduction by the equipment may accelerate the cooling of
device itself, and the condensation may occur.
Please conduct product evaluations in the worst condition of the actual
usage. (Special attention should be paid when high temperature
heating parts are close to the device. Also please consider the
condensation may occur inside of the device.)
Icing
Condensation or other moisture may freeze on relays when the
temperature become lower than 0°C.This icing causes the sticking of
movable portion, the operation delay and the contact conduction failure
etc. Panasonic Corporation does not guarantee the failures caused by
the icing.
The heat conduction by the equipment may accelerate the cooling of
relay itself and the icing may occur. Please conduct product
evaluations in the worst condition of the actual usage.
Low temperature and low humidity
Silicon
When a source of silicone substances (silicone rubber, silicone oil,
silicone coating materials and silicone filling materials etc.) is used
around the relay, the silicone gas (low molecular siloxane etc.) may be
produced.
The plastic becomes brittle if the switch is exposed to a low
temperature, low humidity environment for long periods of time.
High temperature and high humidity
This silicone gas may penetrate into the inside of the relay. When the
relay is kept and used in this condition, silicone compound may adhere
to the relay contacts which may cause the contact failure. Do not use
any sources of silicone gas around the relay (Including plastic seal
types).
Storage for extended periods of time (including transportation periods)
at high temperature or high humidity levels or in atmospheres with
organic gases or sulfide gases may cause a sulfide film or oxide film to
form on the surfaces of the contacts and/or it may interfere with the
functions. Check out the atmosphere in which the units are to be
stored and transported.
NOx Generation
When relay is used in an atmosphere high in humidity to switch a load
which easily produces an arc, the NOx created by the arc and the
water absorbed from outside the relay combine to produce nitric acid.
This corrodes the internal metal parts and adversely affects operation.
Avoid use at an ambient humidity of 85% RH or higher (at 20°C). If use
at high humidity is unavoidable, please contact our sales
representative.
Package
In terms of the packing format used, make every effort to keep the
effects of moisture, organic gases and sulfide gases to the absolute
minimum.
Storage requirements
Since the SMD type is sensitive to humidity it is packaged with tightly
sealed anti-humidity packaging. However, when storing, please be
careful of the following.
1) Please use promptly once the anti-humidity pack is opened.(Signal
relay: within 72 hours, Max. 30°C/70% RH). If left with the pack
open, the relay will absorb moisture which will cause thermal stress
when reflow mounting and thus cause the case to expand. As a
result, the seal may break.
Others
Cleaning
1) Although the environmentally sealed type relay (plastic sealed type,
etc.) can be cleaned, avoid immersing the relay into cold liquid (such
as cleaning solvent) immediately after soldering. Doing so may
deteriorate the sealing performance.
3) Cleaning with the boiling method is recommended (The temperature
of cleaning liquid should be 40°C or lower).
Avoid ultrasonic cleaning on relays. Use of ultrasonic cleaning may
cause breaks in the coil or slight sticking of the contacts due to the
ultrasonic energy.
2) Surface mount terminal type relay is sealed type and it can be
cleaned by immersion. Use pure water or alcohol-based cleaning
solvent.
Please refer to
“the latest product specifications”
when designing your product.
•Requests to customers:
Panasonic Corporation Electromechanical Control Business Division
industrial.panasonic.com/ac/e/
c
Panasonic Corporation 2019
ASCTB414E 201906