PANASONIC-DS2Y-S-DC24V

Part #PANASONIC-DS2Y-S-DC24V
Download 
PANASONIC-DS2Y-S-DC24V
Miniature Relay  
DS2Y REL
A
Y
S  
FEATURES  
TYPICAL APPLICATIONS  
1. 2 Form C contact  
1. Telecommunication equipment  
2. Office equipment  
2. High sensitivity-200 mW nominal  
operating power  
3. High breakdown voltage  
1500 V FCC surge between open  
contacts  
3. Computer peripherals  
4. Security alarm systems  
5. Medical equipment  
4. DIP-2C type matching 16 pin IC  
socket  
5. Sealed construction  
RoHS compliant  
ORDERING INFORMATION  
DS2Y-S  
Operating function  
Nil: Single side stable  
Nominal coil voltage  
DC 3, 5, 6, 9, 12, 24, 48 V  
Note: UL/CSA approved type is standard.  
TYPES  
Single side stable type  
Part No.  
Contact arrangement  
Nominal coil voltage  
3 V DC  
5 V DC  
DS2
Y
–
S-DC3V  
DS2
Y
–
S-DC5V  
DS2
Y
–
S-DC6V  
DS2
Y
–
S-DC9V  
DS2
Y
–
S-DC12V  
DS2
Y
–
S-DC24V  
DS2
Y
–
S-DC48V  
6 V DC  
2 Form C  
9 V DC  
12 V DC  
24 V DC  
48 V DC  
Standard packing:
T
u
be: 50 pcs.; Case: 500 pcs.  
ASCTB16E 201407-T  
–1–  

DS2Y  
RATING  
1. Coil data  
Single side stable type  
Nominal operating  
current  
[ 10%]
 
(at 20
°
C
68
°
F
)  
Nominal coil  
voltage  
Pick-up voltage  
(at 20
°
C
68
°
F
)  
Drop-out voltage  
(at 20
°
C
68
°
F
)  
Coil resistance  
[ 10%]
 
(at 20
°
C
68
°
F
)  
Nominal operating  
power  
Max. applied voltage  
(at 50
°
C
122
°
F
)  
3 V DC  
5 V DC  
66.7 mA  
40 mA  
33.3 mA  
22.2 mA  
16.7 mA  
8.3 mA  
45
Ω  
125
Ω  
180
Ω  
405
Ω  
720
Ω  
6 V DC  
70%V or less of  
nominal voltage  
(Initial)  
10%V or more of  
nominal voltage  
(Initial)  
200 mW  
300 mW  
200%V of  
nominal voltage  
9 V DC  
12 V DC  
24 V DC  
48 V DC  
2,880
Ω  
7,680
Ω  
6.3 mA  
2. Specifications  
Characteristics  
Item  
Specifications  
Arrangement  
2 Form C  
Contact  
Initial contact resistance, max.  
Contact material  
Max. 50 m
Ω
(By voltage drop 6 V DC 1A)  
Ag+Au clad  
Max. switching power  
Max. switching voltage  
Max. switching current  
Max. carrying current  
Minimum operating power  
Nominal operating power  
60 W, 62.5 VA (resistive load)  
220 V DC, 250 V AC  
2 A  
Rating  
3 A  
Approx. 98 mW (147 mW: 48 V)  
Approx. 200 mW (300 mW: 48 V)  
Min. 100M
Ω
(at 500V DC)  
Insulation resistance (Initial)  
Measurement at same location as “Initial breakdown voltage” section.  
Between open contacts  
750 Vrms for 1min. (Detection current: 10mA.)  
Breakdown voltage  
(Initial)  
Between contact sets  
1,000 Vrms for 1min. (Detection current: 10mA.)  
Between contact and coil  
1,000 Vrms for 1min. (Detection current: 10mA.)  
Electrical  
characteristics  
FCC surge breakdown voltage between contacts  
and coil  
1,500 V  
T
e
mperature rise (at 20
°
C
68
°
F
)  
Max. 65
°
C with nominal coil voltage across coil and at nominal switching capacity  
Approx. 4 ms [approx. 3 ms]  
(Nominal coil voltage applied to the coil, excluding contact bounce time.)  
Operate time [Set time] (at 20
°
C
68
°
F
)  
Approx. 3 ms [approx. 3 ms]  
(Nominal coil voltage applied to the coil, excluding contact bounce time.) (without diode)  
Release time [Reset time] (at 20
°
C
68
°
F
)  
Functional  
Shock resistance  
Min. 490 m/s

2

(Half-wave pulse of sine wave: 11 ms; detection time: 10
μ
s.)  
Min. 980 m/s

2

(Half-wave pulse of sine wave: 6 ms.)  
10 to 55 Hz at double amplitude of 3.3 mm (Detection time: 10
μ
s.)  
10 to 55 Hz at double amplitude of 5 mm  
Destructive  
Mechanical  
characteristics  
Functional  
Vibration resistance  
Destructive  
Mechanical  
Electrical  
Min. 10

8  

Expected life  
Min. 5
×
10

5

(1 A 30 V DC), Min. 10

5

(2 A 30 V DC)  
Ambient temperature: –40
°
C to +70
°
C
–40
°
F to +158
°
F  
Conditions for operation, transport and storage*  
Max. operating speed (at rated load)  
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)  
Conditions  
Unit weight  
60 cpm  
Approx. 4g
.14oz  
Notes: *1
 
This value can change due to the switching frequenc
y
,
e
nvironmental conditions, and desired reliability level, therefore it is recommended to check this with the  
actual load. TX/TX-S/TX-D relay AgPd contact type are available for low level load switching (10V DC, 10mA max. level).  
*2 Half-wave
 
pulse of sine wave: 11ms; detection time: 10
μ
s  
*3 Refer
 
to “AMBIENT ENVIRONMENT” in GENERAL APPLIC
A
T
ION GUIDELINES.  
ASCTB16E 201407-T  
–2–  

DS2Y  
REFERENCE DATA  
1. Maximum switching capacity  
2. Coil temperature rise (Single side stable)  
T
e
sted sample: DS2
Y
–
S-DC12
V
, 5
p
cs.  
Measured portion: Inside the coil  
3. Operate/release time for single side stable  
(Without diode)  
T
e
sted sample: DS2
Y
–
S-DC12
V
,
1
0 pcs.  
Ambient temperature: 21
°
C to 25
°
C
70
°
F to 77
°
F  
Ambient temperature: 20
°
C
68
°
F  
1,000 V  
100 V  
Operate time  
Release time  
5
4
3
2
1
3 A  
30  
2 A  
Mean value  
Mean value  
0 A  
10 V  
20  
10 mA  
0
80  
100  
120  
100  
110  
10
μ
A  
100 mA  
1 A  
Coil applied voltage, %V  
Coil applied voltage, %V  
Switching current  
4-(1) Influence of adjacent mounting  
4-(2) Influence of adjacent mounting  
T
e
sted sample: DS2
Y
–
S-DC12
V
,
1
0 pcs.  
Ambient temperature: 20
°
C
68
°
F  
T
e
sted sample: DS2
Y
–
S-DC12
V
,
1
0 pcs.  
Ambient temperature: 20
°
C
68
°
F  
TEST METHOD  
1. Apply nominal voltage to No. (1) and (3) DS2Y  
relays.  
TEST METHOD  
1. Apply nominal voltage to No. (1) and (3) DS2Y  
relays.  
2. Measure pick-up voltage and drop-out voltage of  
No. (2) relay when inter-relay distance (
 
) changes.  
2. Measure pick-up voltage and drop-out voltage of  
No. (2) relay when inter-relay distance (
 
) changes.  
(1)  
(2)  
(3)  
OFF  
OFF  
10  
8
10  
(1)  
(2)  
(3)  
OFF  
OFF  
8
6
4
2
0
ON  
OFF  
ON  
ON  
OFF  
ON  
Pick-up voltage  
Drop-out voltage  
Pick-up voltage  
Drop-out voltage  
ON  
OFF  
ON  
ON  
OFF  
ON  
6
4
2
0
5
10  
.197 .394 .591  
Inter-relay distance, mm
inch  
15  
5
10  
.197 .394 .591  
Inter-relay distance, mm
inch  
15  
The CAD data of the products with a
 
CAD Data
 

DIMENSIONS
(mm
inch
)  
Single side stable  
CAD Data  
External dimensions  
PC board pattern (Copper-side view)  
Schematic (Bottom view)  
(Deenergized position)  
8-0.9 dia.  
8-.035 dia.  
20  
9.9  
.390  
.787  
9
11  
13  
16  
–
N.O. N.C.
 
COM  
2.54  
.100  
2.54  
.100  
9.3  
.366  
0.6  
.024  
7.62  
.300  
3.4  
.134  
0.6  
N.O. N.C.
 
COM  
+
1
.024  
2.0  
8
6
4
0.3  
.012  
.078  
5.6  
.220  
7.62  
.300  
0.6  
.024  
matching 16 pin IC socket  
Direction indication*  
5.08 5.08  
.200 .200  
7.62  
.300  
*A polarity bar shows the relay direction.  
T
o
lerance: 0.1
.004  
General tolerance:
 
0.3
.012  
For general cautions for use,  
please refer to the “Cautions for  
use of Signal Relays” or “General  
Application Guidelines”.  
ASCTB16E 201407-T  