PANASONIC-DS2Y-S-DC5V
| Part # | PANASONIC-DS2Y-S-DC5V |
| Download | PANASONIC-DS2Y-S-DC5V |
Miniature Relay
DS2Y REL
A
Y
S
FEATURES
TYPICAL APPLICATIONS
1. 2 Form C contact
1. Telecommunication equipment
2. Office equipment
2. High sensitivity-200 mW nominal
operating power
3. High breakdown voltage
1500 V FCC surge between open
contacts
3. Computer peripherals
4. Security alarm systems
5. Medical equipment
4. DIP-2C type matching 16 pin IC
socket
5. Sealed construction
RoHS compliant
ORDERING INFORMATION
DS2Y-S
Operating function
Nil: Single side stable
Nominal coil voltage
DC 3, 5, 6, 9, 12, 24, 48 V
Note: UL/CSA approved type is standard.
TYPES
Single side stable type
Part No.
Contact arrangement
Nominal coil voltage
3 V DC
5 V DC
DS2
Y
–
S-DC3V
DS2
Y
–
S-DC5V
DS2
Y
–
S-DC6V
DS2
Y
–
S-DC9V
DS2
Y
–
S-DC12V
DS2
Y
–
S-DC24V
DS2
Y
–
S-DC48V
6 V DC
2 Form C
9 V DC
12 V DC
24 V DC
48 V DC
Standard packing:
T
u
be: 50 pcs.; Case: 500 pcs.
ASCTB16E 201407-T
–1–
DS2Y
RATING
1. Coil data
Single side stable type
Nominal operating
current
[ 10%]
(at 20
°
C
68
°
F
)
Nominal coil
voltage
Pick-up voltage
(at 20
°
C
68
°
F
)
Drop-out voltage
(at 20
°
C
68
°
F
)
Coil resistance
[ 10%]
(at 20
°
C
68
°
F
)
Nominal operating
power
Max. applied voltage
(at 50
°
C
122
°
F
)
3 V DC
5 V DC
66.7 mA
40 mA
33.3 mA
22.2 mA
16.7 mA
8.3 mA
45
Ω
125
Ω
180
Ω
405
Ω
720
Ω
6 V DC
70%V or less of
nominal voltage
(Initial)
10%V or more of
nominal voltage
(Initial)
200 mW
300 mW
200%V of
nominal voltage
9 V DC
12 V DC
24 V DC
48 V DC
2,880
Ω
7,680
Ω
6.3 mA
2. Specifications
Characteristics
Item
Specifications
Arrangement
2 Form C
Contact
Initial contact resistance, max.
Contact material
Max. 50 m
Ω
(By voltage drop 6 V DC 1A)
Ag+Au clad
Max. switching power
Max. switching voltage
Max. switching current
Max. carrying current
Minimum operating power
Nominal operating power
60 W, 62.5 VA (resistive load)
220 V DC, 250 V AC
2 A
Rating
3 A
Approx. 98 mW (147 mW: 48 V)
Approx. 200 mW (300 mW: 48 V)
Min. 100M
Ω
(at 500V DC)
Insulation resistance (Initial)
Measurement at same location as “Initial breakdown voltage” section.
Between open contacts
750 Vrms for 1min. (Detection current: 10mA.)
Breakdown voltage
(Initial)
Between contact sets
1,000 Vrms for 1min. (Detection current: 10mA.)
Between contact and coil
1,000 Vrms for 1min. (Detection current: 10mA.)
Electrical
characteristics
FCC surge breakdown voltage between contacts
and coil
1,500 V
T
e
mperature rise (at 20
°
C
68
°
F
)
Max. 65
°
C with nominal coil voltage across coil and at nominal switching capacity
Approx. 4 ms [approx. 3 ms]
(Nominal coil voltage applied to the coil, excluding contact bounce time.)
Operate time [Set time] (at 20
°
C
68
°
F
)
Approx. 3 ms [approx. 3 ms]
(Nominal coil voltage applied to the coil, excluding contact bounce time.) (without diode)
Release time [Reset time] (at 20
°
C
68
°
F
)
Functional
Shock resistance
Min. 490 m/s
2
(Half-wave pulse of sine wave: 11 ms; detection time: 10
μ
s.)
Min. 980 m/s
2
(Half-wave pulse of sine wave: 6 ms.)
10 to 55 Hz at double amplitude of 3.3 mm (Detection time: 10
μ
s.)
10 to 55 Hz at double amplitude of 5 mm
Destructive
Mechanical
characteristics
Functional
Vibration resistance
Destructive
Mechanical
Electrical
Min. 10
8
Expected life
Min. 5
×
10
5
(1 A 30 V DC), Min. 10
5
(2 A 30 V DC)
Ambient temperature: –40
°
C to +70
°
C
–40
°
F to +158
°
F
Conditions for operation, transport and storage*
Max. operating speed (at rated load)
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Conditions
Unit weight
60 cpm
Approx. 4g
.14oz
Notes: *1
This value can change due to the switching frequenc
y
,
e
nvironmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load. TX/TX-S/TX-D relay AgPd contact type are available for low level load switching (10V DC, 10mA max. level).
*2 Half-wave
pulse of sine wave: 11ms; detection time: 10
μ
s
*3 Refer
to “AMBIENT ENVIRONMENT” in GENERAL APPLIC
A
T
ION GUIDELINES.
ASCTB16E 201407-T
–2–
DS2Y
REFERENCE DATA
1. Maximum switching capacity
2. Coil temperature rise (Single side stable)
T
e
sted sample: DS2
Y
–
S-DC12
V
, 5
p
cs.
Measured portion: Inside the coil
3. Operate/release time for single side stable
(Without diode)
T
e
sted sample: DS2
Y
–
S-DC12
V
,
1
0 pcs.
Ambient temperature: 21
°
C to 25
°
C
70
°
F to 77
°
F
Ambient temperature: 20
°
C
68
°
F
1,000 V
100 V
Operate time
Release time
5
4
3
2
1
3 A
30
2 A
Mean value
Mean value
0 A
10 V
20
10 mA
0
80
100
120
100
110
10
μ
A
100 mA
1 A
Coil applied voltage, %V
Coil applied voltage, %V
Switching current
4-(1) Influence of adjacent mounting
4-(2) Influence of adjacent mounting
T
e
sted sample: DS2
Y
–
S-DC12
V
,
1
0 pcs.
Ambient temperature: 20
°
C
68
°
F
T
e
sted sample: DS2
Y
–
S-DC12
V
,
1
0 pcs.
Ambient temperature: 20
°
C
68
°
F
TEST METHOD
1. Apply nominal voltage to No. (1) and (3) DS2Y
relays.
TEST METHOD
1. Apply nominal voltage to No. (1) and (3) DS2Y
relays.
2. Measure pick-up voltage and drop-out voltage of
No. (2) relay when inter-relay distance (
) changes.
2. Measure pick-up voltage and drop-out voltage of
No. (2) relay when inter-relay distance (
) changes.
(1)
(2)
(3)
OFF
OFF
10
8
10
(1)
(2)
(3)
OFF
OFF
8
6
4
2
0
ON
OFF
ON
ON
OFF
ON
Pick-up voltage
Drop-out voltage
Pick-up voltage
Drop-out voltage
ON
OFF
ON
ON
OFF
ON
6
4
2
0
5
10
.197 .394 .591
Inter-relay distance, mm
inch
15
5
10
.197 .394 .591
Inter-relay distance, mm
inch
15
The CAD data of the products with a
CAD Data
mark can be downloaded from: http://industrial.panasonic.com/ac/e/
DIMENSIONS
(mm
inch
)
Single side stable
CAD Data
External dimensions
PC board pattern (Copper-side view)
Schematic (Bottom view)
(Deenergized position)
8-0.9 dia.
8-.035 dia.
20
9.9
.390
.787
9
11
13
16
–
N.O. N.C.
COM
2.54
.100
2.54
.100
9.3
.366
0.6
.024
7.62
.300
3.4
.134
0.6
N.O. N.C.
COM
+
1
.024
2.0
8
6
4
0.3
.012
.078
5.6
.220
7.62
.300
0.6
.024
matching 16 pin IC socket
Direction indication*
5.08 5.08
.200 .200
7.62
.300
*A polarity bar shows the relay direction.
T
o
lerance: 0.1
.004
General tolerance:
0.3
.012
For general cautions for use,
please refer to the “Cautions for
use of Signal Relays” or “General
Application Guidelines”.
ASCTB16E 201407-T
–3–