PANASONIC-DSP1-DC3V-F

Part #PANASONIC-DSP1-DC3V-F
Download 
PANASONIC-DSP1-DC3V-F
Automation Controls Catalog  
1a 8A, 1a1b/2a 5A  
small polarized power  
relays  
DSP RELAYS  
3. High sensitivity  
TYPICAL APPLICATIONS  
Using the same type of highperformance  
polar magnetic circuits as DS relays, by  
matching the spring load to the magnetic  
force of attraction, greater sensitivity  
has been achieved. The resultant pick  
up sensitivity of about 190 mW makes  
possible direct driving of transistors and  
chips.  
1.
Office and industrial electronic  
devices  
2. Terminal devices of information  
processing equipment, such as  
printer, data recorder  
3.
Office equipment (copier, facsimile)  
4. Measuring instruments  
5. NC machines, temperature  
controllers and programmable logic  
controllers  
4. High breakdown voltage  
Breakdown voltage has been raised by  
keeping the coil and contacts separate.  
Between contact and  
Between contacts  
coil  
Protective construction: Sealed type  
3,000 Vrms for 1 min.  
5,000 V surge  
1,000 Vrms for 1 min.  
1,500 V surge  
breakdown voltage  
breakdown voltage  
Conforms with FCC Part 68  
5. Latching types available  
6. Wide variation  
Three types of contact arrangement  
are offered: 1a, 2a, and 1a1b. In  
addition, each is available in standard  
and reversed polarity types.  
7. Sealed construction allows  
automatic washing  
8. Complies with safety standards  
Complies with Japan Electrical  
Appliance and Material Safety Law  
requirements for operating 200 V  
power supply circuits, and complies  
with UL, CSA, and TÜV safety  
standards.  
FEATURES  
1. Compact with high contact rating  
Even with small 10 mm
.394 inch
(H) x  
11 mm
.433 inch
(W) x 20 mm
.787  
inch
(L) (dimensions, high capacity  
switching is provided: 1a, 8 A 250 V  
AC; 2a and 1a1b, 5 A 250 V AC.  
2. High switching capability  
High contact pressure, low contact  
bounce, and wiping operation improve  
resistance to weld bonding. Resistant  
against lamp load and dielectric  
loading: 1a achieves maximum  
switching capacity of 2,000 VA (8A 250  
V AC).  
9. Sockets are available  
ORDERING INFORMATION  
DSP  
Contact arrangement  
Operating function  
Nominal coil voltag
e
(
DC
)
Polarity  
Contact material  
1a
:
1 Form A  
Nil
:
Single side stable
 
3, 5, 6, 9, 12, 24 V  
Nil
:
Standard polarity
 
• AgSnO
 
type  
2
1
:
1 Form A 1 Form B
 
L2
:
2 coil latching  
2a
:
2 Form A  
R
:
Reverse polarity  
F
:
1 Form A 1 Form B  
Nil
:
1 Form A, 2 Form A  
Notes
:
1. Reverse
 
polarity types availabl
e
(
add suffix-R
)  
2. Certified
 
by UL, CSA and TÜV  
industrial.panasonic.com/ac/e/  
© Panasonic Corporation 2019  
ASCTB180E 201903  
2019.03  
1

DSP  
TYPES  
Single side stable  
Part No.  
2 coil latching  
Contact  
Nominal coil  
voltage  
arrangement  
Part No.  
3V DC  
5V DC  
6V DC  
9V DC  
12V DC  
24V DC  
3V DC  
5V DC  
6V DC  
9V DC  
12V DC  
24V DC  
3V DC  
5V DC  
6V DC  
9V DC  
12V DC  
24V DC  
DSP1a-DC3V  
DSP1a-DC5V  
DSP1a-DC6V  
DSP1a-DC9V  
DSP1a-DC12V  
DSP1a-DC24V  
DSP1-DC3V-F  
DSP1-DC5V-F  
DSP1-DC6V-F  
DSP1-DC9V-F  
DSP1-DC12V-F  
DSP1-DC24V-F  
DSP2a-DC3V  
DSP2a-DC5V  
DSP2a-DC6V  
DSP2a-DC9V  
DSP2a-DC12V  
DSP2a-DC24V  
DSP1a-L2-DC3V  
DSP1a-L2-DC5V  
DSP1a-L2-DC6V  
DSP1a-L2-DC9V  
DSP1a-L2-DC12V  
DSP1a-L2-DC24V  
DSP1-L2-DC3V-F  
DSP1-L2-DC5V-F  
DSP1-L2-DC6V-F  
DSP1-L2-DC9V-F  
DSP1-L2-DC12V-F  
DSP1-L2-DC24V-F  
DSP2a-L2-DC3V  
DSP2a-L2-DC5V  
DSP2a-L2-DC6V  
DSP2a-L2-DC9V  
DSP2a-L2-DC12V  
DSP2a-L2-DC24V  
1 Form A  
1 Form A  
1 Form B  
2 Form A  
Standard packing: Carton: 50 pcs.; Case: 500 pcs.  
Note: Reverse polarity type are manufactured by lot upon receipt of order.  
* Sockets available.  
RATING  
1.Coil data  
• Operating characteristics such as ‘Operate voltage’ and ‘Release voltage’ are influenced by mounting conditions, ambient temperature, etc.  
Therefore, please use the relay within ± 5% of rated coil voltage.  
• ‘Initial’ means the condition of products at the time of delivery.  
1) Single side stable  
Nominal operating  
current  
[±10%] (at 20°C
68°F
)  
Nominal coil  
voltage  
Pick-up voltage  
(at 20°C
68°F
)  
Drop-out voltage  
(at 20°C
68°F
)  
Coil resistance  
[±10%] (at 20°C
68°F
)  
Nominal operating  
power  
Max. applied voltage  
(at 20°C
68°F
)  
3V DC  
5V DC  
6V DC  
9V DC  
12V DC  
24V DC  
100 mA  
60 mA  
50 mA  
33.3mA  
25 mA  
12.5mA  
30Ω  
83Ω  
80%V or less of  
nominal voltage  
(Initial)  
10%V or more of  
nominal voltage  
(Initial)  
120Ω  
270Ω  
480Ω  
1,920Ω  
130%V of  
nominal voltage  
300mW  
2) 2 coil latching  
Nominal operating  
current  
[±10%] (at 20°C
68°F
)  
Coil resistance  
[±10%] (at 20°C
68°F
)  
Nominal operating  
power  
Nominal coil  
voltage  
Set voltage  
(at 20°C
68°F
)  
Reset voltage  
(at 20°C
68°F
)  
Max. applied voltage  
(at 20°C
68°F
)  
Set coil  
100 mA  
60 mA  
50 mA  
33.3mA  
25 mA  
12.5mA  
Reset coil  
100 mA  
60 mA  
50 mA  
33.3mA  
25 mA  
12.5mA  
Set coil  
30Ω  
Reset coil  
30Ω  
Set coil  
Reset coil  
3V DC  
5V DC  
6V DC  
9V DC  
12V DC  
24V DC  
83Ω  
83Ω  
80%V or less of  
nominal voltage  
(Initial)  
80%V or less of  
nominal voltage  
(Initial)  
120Ω  
270Ω  
480Ω  
1,920Ω  
120Ω  
270Ω  
480Ω  
1,920Ω  
130%V of  
nominal voltage  
300mW  
300mW  
Panasonic Corporation Electromechanical Control Business Division  
industrial.panasonic.com/ac/e/  
© Panasonic Corporation 2019  
ASCTB180E 201903  
2

DSP  
2. Specifications  
Characteristics  
Item  
Specifications  
1 Form A 1 Form B  
Arrangement  
1 Form A  
2 Form A  
Contact  
Contact resistance (Initial)  
Max. 30 mΩ (By voltage drop 6 V DC 1A)  
Au-flashed AgSnO2 type  
Contact material  
Nominal switching capacity (resistive load)  
Max. switching power (resistive load)  
Max. switching voltage  
8 A 250 V AC, 5A 30V DC  
2,000 VA, 150 W  
5 A 250 V AC, 5 A 30 V DC  
1,250 VA, 150 W  
250 V AC, 125 V DC (0.2 A)  
5 A (AC, DC)  
Rating  
Max. switching current  
8 A (AC), 5 A (DC)  
Nominal operating power  
300 mW  
Min. switching capacity (Reference value)*

1  

10m A 5 V DC  
Min. 1,000MΩ (at 500V DC) Measurement at same location as “Breakdown voltage”  
Insulation resistance (Initial)  
section.  
Between open contacts  
1,000 Vrms for 1min. (Detection current: 10mA.)  
Breakdown voltage (Initial)
 
Between contact sets  
2,000 Vrms (1 Form A 1 Form B, 2 Form A) (Detection current: 10mA.)  
3,000 Vrms for 1min. (Detection current: 10mA.)  
Between contact and coil  
Surge breakdown voltage*

2  

between contacts and coil  
(Initial)  
Electrical  
characteristics  
5,000 V  
Operate time [Set time] (at 20°C
68°F
) (Initial)  
Max. 10 ms [10 ms] (Nominal coil voltage applied to the coil, excluding contact bounce time.)  
Max. 5 ms [10 ms] (Nominal coil voltage applied to the coil, excluding contact bounce time.)  
(without diode)  
Release time [Reset time] (at 20°C
68°F
) (Initial)  
Functional  
Shock resistance  
Min. 196 m/s

2

(Half-wave pulse of sine wave: 11 ms; detection time: 10µs.)  
Min. 980 m/s

2

(Half-wave pulse of sine wave: 6 ms.)  
10 to 55 Hz at double amplitude of 2 mm (Detection time: 10µs.)  
10 to 55 Hz at double amplitude of 3.5 mm  
Destructive  
Mechanical  
characteristics  
Functional  
Vibration resistance  
Destructive  
Mechanical  
Electrical  
Min. 5×10

7

(at 180 times/min.)  
Expected life  
Min. 10

5

(resistive load)  
Ambient temperature:  
–40°C to +60°C  
–40°F to +140°F  
Ambient temperature:  
–40°C to +65°C  
–40°F to +149°F  
Ambient temperature:  
–40°C to +60°C  
–40°F to +140°F  
Conditions for operation, transport and storage*

3

(Not  
freezing and condensing at low temperature)  
Conditions  
Unit weight  
Max. operating speed  
3 cps  
Approx. 4.5 g
.16 oz  
Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the  
actual load.  
*2. Wave is standard shock voltage of ±1.2×50μs according to JEC-212-1981  
*3. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage  
conditions in NOTES.  
REFERENCE DATA  
1. Max. switching capacity  
2.-(1) Life curve (1 Form A 1 Form B)  
2.-(2) Life curve (1 Form A 1 Form B)  
10  
30V DC  
resistive load  
AC resistive  
100  
loa
d
(
1a
)  
100  
50  
AC resistive  
loa
d
(
1a1b,2a
)  
DC resistive  
265
V
・
130V AC  
(
co
s
φ
=
1
)  
loa
d
(
1a
)  
1
30V DC  
265
V
・
130V AC  
(
L/R
=
7ms
)  
10  
(
co
s
φ
=
0.4
)  
DC resistive  
loa
d
(
1a1b, 2a
)  
10  
0.1  
10  
100  
Contact voltag
e
(
V
)  
1,000  
0
1
2
3
4
5
6
7
0.5  
1
5
10  
Switching capacit
(
y A
)  
Switching capacit
(
y A
)  
3.-(1) Coil temperature rise (1 Form A)  
3.-(2) Coil temperature rise  
(1 Form A 1 Form B)  
3.-(3) Coil temperature rise (2 Form A)  
Tested sample
:
DSP1a-12V DC, 5 pcs.  
Tested sample
:
DSP1-12V DC, 5 pcs.  
Tested sample
:
DSP2a-12V DC, 5 pcs.  
60  
60  
60  
5A  
0A  
8A  
0A  
50  
40  
30  
20  
10  
0
50  
40  
30  
20  
10  
0
50  
40  
30  
20  
10  
0
5A  
0A  
80  
100  
120  
80  
100  
120  
80  
100  
120  
Coil applied voltag
e
(
%V
)  
Coil applied voltag
e
(
%V
)  
Coil applied voltag
e
(
%V
)  
Panasonic Corporation Electromechanical Control Business Division  
industrial.panasonic.com/ac/e/  
© Panasonic Corporation 2019  
ASCTB180E 201903  
3

DSP  
4.-(1) Operate & release time  
(without diode, 1 Form A)  
4.-(2) Operate & release time  
(without diode, 1 Form A 1 Form B)  
4.-(3) Operate & release time  
(without diode, 2 Form A)  
Tested sample
:
DSP1a-12V DC, 5 pcs.  
Tested sample
:
DSP1-12V DC, 5 pcs.  
Tested sample
:
DSP2a-12V DC, 5 pcs.  
7
9
9
8
7
6
8
7
6
6
5
Operate time  
Operate time  
4
3
2
1
0
5
5
4
3
2
1
0
Max.  
Operate time  
4
Ave.  
Min.  
Max.  
Ave.  
Min.  
Max.  
Ave.  
3
2
1
0
Min.  
Max.  
Ave.  
Min.  
Release time  
100  
Release time  
Max.  
Ave.  
Min.  
Release time  
100  
Max.  
Ave.  
Min.  
80  
120  
80  
100  
110  
80  
120  
Coil applied voltag
e
(
%V
)  
Coil applied voltag
e
(
%V
)  
Coil applied voltag
e
(
%V
)  
4.-(4) Operate & release time  
(with diode, 1 Form A)  
4.-(5) Operate & release time  
(with diode, 1 Form A 1 Form B)  
4.-(6) Operate & release time  
(with diode, 2 Form A)  
Tested sample
:
DSP1a-12V DC, 5 pcs.  
Tested sample
:
DSP1-12V DC, 5 pcs.  
Tested sample
:
DSP2a-12V DC, 5 pcs.  
9
9
9
8
7
6
8
8
7
Max.  
7
6
6
Operate time  
Ave.  
Operate time  
5
4
3
2
1
0
5
4
3
2
1
0
Operate time  
Release time  
5
4
3
2
Min.  
Max.  
Ave.  
Min.  
Max.  
Ave.  
Min.  
Max.  
Ave.  
Min.  
Max.  
Ave.  
Min.  
Max.  
Ave.  
Min.  
Release time  
100  
Release time  
1
0
80  
120  
80  
100  
110  
80  
100  
120  
Coil applied voltag
e
(
%V
)  
Coil applied voltag
e
(
%V
)  
Coil applied voltag
e
(
%V
)  
5.-(1) Change of pick-up and drop-out voltage  
(1 Form A)  
5.-(2) Change of pick-up and drop-out voltage  
(1 Form A 1 Form B)  
5.-(3) Change of pick-up and drop-out voltage  
(2 Form A)  
Tested sample
:
DSP1a-12V DC, 5 pcs.  
Tested sample
:
DSP1-12V DC, 5 pcs.  
Tested sample
:
DSP2a-12V DC, 5 pcs.  
30  
30  
30  
20  
20  
20  
10  
Release voltage  
Operate voltage  
10  
10  
Operate voltage  
ー
60
ー
40
ー
20  
0
ー
60
ー
40
ー
20  
0
ー
60
ー
40
ー
20  
0
Release voltage  
Release voltage  
20 40
 
60 80
 
100  
20 40
 
60 80
 
100  
20 40
 
60 80
 
100  
Ambient  
Ambient  
Ambient  
temperatur
(
e
℃
)  
temperatur
(
e
℃
)  
temperatur
(
e
℃
)  
Operate voltage  
ー
10  
ー
20  
ー
30  
ー
10  
ー
20  
ー
30  
ー
10  
ー
20  
ー
30  
6.-(1) Influence of adjacent mounting  
6.-(2) Influence of adjacent mounting  
6.-(3) Influence of adjacent mounting  
(1 Form A)  
(1 Form A 1 Form B)  
(2 Form A)  
Tested sample
:
DSP1a-12V DC, 5 pcs.  
Tested sample
:
DSP1-12V DC, 5 pcs.  
Tested sample
:
DSP2a-12V DC, 5 pcs.  
15  
15  
10  
8
A
B
C
A
B
C
A B C  
10  
10  
ℓ
ℓ
ℓ
ℓ
ℓ ℓ  
6
4
2
A, C  
A, C  
A, C  
5
Operate voltage  
Operate voltage  
Release voltage  
5
Operate voltage  
relays  
relays  
relays  
are not  
are not  
are not  
energized  
energized  
energized  
0
15  
10  
5
15  
10  
5
0
A, C  
A, C  
A, C  
relays  
are  
relays  
are  
relays  
are  
ー
2  
ー
4  
energized  
energized  
energized  
ー
6  
Release voltage  
5
Release voltage  
5
ー
8  
ー
10  
0
0
10  
1
2
3
4
5
6
10  
Inter-relay distanc
e
(
ℓ
)
, mm  
Inter-relay distanc
e
(
ℓ
)
, mm  
Inter-relay distanc
e
(
ℓ
)
, mm  
Panasonic Corporation Electromechanical Control Business Division  
industrial.panasonic.com/ac/e/  
© Panasonic Corporation 2019  
ASCTB180E 201903  
4

DSP  
(mm)  
CAD  
The CAD data of the products with a “CAD” mark can be downloaded from our Website.  
DIMENSIONS  
1. 1 Form A type  
CAD  
External dimensions  
Single side stable  
20.2  
2 coil latching  
20.2  
4
ー
0.8  
4
ー
0.3  
6
ー
0.8  
.
6
ー
0 3  
7.62  
1.21  
7.62 7.62  
2.54  
7.62  
1.21  
7.62  
10.16  
PC board pattern (Bottom view)  
Schematic (Bottom view)  
Single side stable  
2 coil latching  
Single side stable  
2 coil latching  
7.62  
10.16  
7.62 7.62  
2.54  
16  
-
15 16  
-
-
+
1
+
2
+
1
8
5
8
5
(Deenergized condition)  
(Reset condition)  
4
ー
1.2dia.  
6
ー
1.2dia.  
Tolerance
±
0.1  
Tolerance
±
0.1  
2. 1 Form A 1 Form B type  
CAD  
External dimensions  
Single side stable  
20.2  
2 coil latching  
20.2  
6
ー
0.8  
6
ー
0.3  
8
ー
0.8  
8
ー
0.3  
1.21  
7.62  
10.16  
7.62  
1.21  
7.62 7.62  
2.54  
7.62  
General tolerance
±
0.3  
General tolerance
±
0.3  
PC board pattern (Bottom view)  
Schematic (Bottom view)  
Single side stable  
2 coil latching  
Single side stable  
2 coil latching  
7.62  
10.16  
7.62 7.62  
2.54  
9
12  
16  
-
9
12  
15 16  
-
-
+
1
+
2
+
1
8
5
8
5
(Deenergized condition)  
(Reset condition)  
6
ー
1.2dia.  
8
ー
1.2dia.  
Tolerance
±
0.1  
Tolerance
±
0.1  
3. 2 Form A type  
CAD  
External dimensions  
Single side stable  
20.2  
2 coil latching  
20.2  
6
ー
0.8  
6
ー
0.3  
8
ー
0.8  
8
ー
0.3  
1.21  
7.62  
10.16  
7.62  
1.21  
7.62 7.62  
2.54  
7.62  
General tolerance
±
0.3  
General tolerance
±
0.3  
PC board pattern (Bottom view)  
Schematic (Bottom view)  
Single side stable  
2 coil latching  
Single side stable  
2 coil latching  
7.62  
10.16  
7.62 7.62  
2.54  
9
12  
16  
-
9
12  
15 16  
-
-
+
1
+
2
+
1
8
5
8
5
(Deenergized condition)  
(Reset condition)  
6
ー
1.2dia.  
8
ー
1.2dia.  
Tolerance
±
0.1  
Tolerance
±
0.1  
Panasonic Corporation Electromechanical Control Business Division  
industrial.panasonic.com/ac/e/  
© Panasonic Corporation 2019  
ASCTB180E 201903  
5

DSP  
SAFETY STANDARDS  
UL (Recognized)  
CSA (Certified)  
Contact rating  
TÜV (Certified)  
Contact rating  
Item  
File No.  
E43028  
Contact rating  
File No.  
File No.  
B 13 11  
13461 342  
8A 125/250V AC General use  
1/6HP 125/250V AC  
5A 30V DC Resistive  
B300  
LR26550  
8A 125/250V AC General use  
1/6HP 125/250V AC  
5A 30V DC Resistive  
B300  
8A 250V AC (cosφ =1.0)  
5A 250V AC (cosφ =0.4)  
5A 30V DC (0 ms)  
1 Form A  
E43028  
5A 125/250V AC General use  
1/6HP 125/250V AC  
5A 30V DC Resistive  
30W Max.: 1A 30V DC-0.24A  
125V DC  
LR26550  
5A 125/250V AC General use  
1/6HP 125/250V AC  
5A 30V DC Resistive  
30W Max.: 1A 30V DC-0.24A  
125V DC  
B 13 11  
13461 342  
5A 250V AC (cosφ =1.0)  
3A 250V AC (cosφ =0.4)  
5A 30V DC (0 ms)  
1 Form A  
1 Form B  
B300  
E43028  
5A 125/250V AC General use  
1/10HP 125/250V AC  
5A 30V DC Resistive  
LR26550  
5A 125/250V AC General use  
1/10HP 125/250V AC  
5A 30V DC Resistive  
B 13 11  
13461 342  
5A 250V AC (cosφ =1.0)  
3A 250V AC (cosφ =0.4)  
5A 30V DC (0 ms)  
2 Form A  
* Remarks: The standard certified for may differ depending on where the product was manufactured.  
NOTES  
1. For cautions for use, please read  
“GENERAL APPLICATION  
GUIDELINES”.  
4. External magnetic field  
Since DSP relays are highly sensitive  
polarized relays, their characteristics will  
be affected by a strong external magnetic  
field. Avoid using the relay under that  
condition.  
2. Soldering conditions  
Please obey the following conditions  
when soldering automatically.  
1) Preheating: Within 120°C
248°F
and  
within 120 seconds  
2) Soldering iron: 260°C±5°C  
500°F±41°F
and within 6 seconds  
3. Cleaning  
For automatic cleaning, the boiling  
method is recommended. Avoid  
ultrasonic cleaning which subjects the  
relays to high frequency vibrations, which  
may cause the contacts to stick.  
It is recommended that a fluorinated  
hydrocarbon or other alcoholic solvents  
be used.  
5. Coil operating power  
Pure DC current should be applied to the  
coil. The wave form should be  
rectangular. If it includes ripple, the ripple  
factor should be less than 5%.  
However, check it with the actual circuit  
since the characteristics may be slightly  
different.  
6. When using, please be aware that  
the a contact and b contact sides of  
1 Form A 1 Form B type may go on  
simultaneously at operate time and  
release time.  
Please refer to
“the latest product specifications”  
when designing your product.  
• Requests to customers :  
Panasonic Corporation Electromechanical Control Business Division  
industrial.panasonic.com/ac/e/  
© Panasonic Corporation 2019  
ASCTB180E 201903  
6

DSP RELAYS  
ACCESSORIES  
TYPES  
PC BOARD SOCKETS  
Part No.  
Product name  
For Single side stable  
DSP1a-PS  
For 2 coil latching  
DSP1a-PSL2  
For DSP1a  
For DSP1a, DSP1, DSP2a  
DSP2a-PS  
DSP2a-PSL2  
Standard packing: Carton: 50 pcs.; Case: 500 pcs.  
TYPES AND APPLICABLE REL
A
Y
S  
SPECIFICATIONS  
Type No.  
Item  
Specifications  
For DSP1a  
For DSP1a, DSP1, DSP2a  
3,000 Vrms between terminals  
(Except for the portion between coil terminals)  
Breakdown voltage  
Applicable  
relays  
DSP1a-PS DSP1a-PSL2 DSP2a-PS DSP2a-PSL2  
Insulation resistance  
Heat resistance  
1,000 MΩ between terminals at 500 V  
DSP1a relays  
DSP1a-L2 relays  
DSP1 relays  
OK  
OK  
OK  
OK  
OK  
OK  
OK  
OK  
OK  
OK  
OK  
OK  
150°C
302°F
for 1 hour  
8 A (DSP1a-PS and DSP1a-PSL2),  
5 A (DSP2a-PS and DSP2a-PSL2)  
Max. continuous current  
DSP1-L2 relays  
DSP2a relays  
DSP2a-L2 relays  
(mm)  
CAD  
The CAD data of the products with a “CAD” mark can be downloaded from our Website.  
DIMENSIONS  
External dimensions  
PC board pattern (Bottom view)  
CAD  
DSP1a-PS, DSP1a-PSL2  
DSP2a-PS, DSP2a-PSL2  
23
±
0.6  
2 coil latching type only  
2 coil latching type only  
15  
16  
1
9
12 15  
5
16  
1
2 coil latching type only  
8
5
2
8
2
1.2dia. 2.54  
1.2dia. 2.54  
2 coil latching type only  
2 coil latching type only  
Tolerance
±
0.1  
Tolerance
±
0.1  
Not
e
:
Terminal No.2 and 15 are for  
Not
e
:
Terminal No.2 and 15 are for  
DSP1a-PSL2 only.  
DSP2a-PSL2 only.  
4
ー
0.8
±
0.1  
0.65
±
0.1  
2.61  
7.62  
10.16  
7.62  
7.62  
2.54  
General tolerance
±
0.3  
FIXING AND REMOVAL METHOD  
1. Match the direction of relay and socket.  
3. Remove the relay, applying force in the  
direction shown below.  
4. In case there is not enough space for  
finger to pick relay up, use screw drivers  
in the way shown below.  
2. Both ends of relays are fixed so tightly  
that the socket hooks on the top surface  
of relays.  
Notes: 1. Exercise care when removing relays. If  
greater than necessary force is applied at  
the socket hooks, deformation may alter the  
dimensions so that the hook will no longer  
catch, and other damage may also occur.  
2. It is hazardous to use IC chip sockets.  
industrial.panasonic.com/ac/e/  
© Panasonic Corporation 2019  
ASCTB266E 201903  
2019.03  
1

GUIDELINES FOR POWER REL
A
Y
S AND HIGH-CAPACITY DC CUT OFF RELAYS USAGE  
For cautions for use, please read “GUIDELINES FOR REL
A
Y
U
SAGE”.  
Precautions for Coil Input  
Long term current carrying  
Maximum allowable voltage and temperature rise  
Proper usage requires that the rated coil voltage be impressed on the  
coil. Note, however, that if a voltage greater than or equal to the  
maximum continuous voltage is impressed on the coil, the coil may  
burn or its layers short due to the temperature rise. Furthermore, do  
not exceed the usable ambient temperature range listed in the catalog.  
A circuit that will be carrying a current continuously for long periods  
without relay switching operation. (circuits for emergency lamps, alarm  
devices and error inspection that, for example, revert only during  
malfunction and output warnings with form B contacts)
 
Continuous,  
long-term current to the coil will facilitate deterioration of coil insulation  
and characteristics due to heating of the coil itself.  
Operate voltage change due to coil temperature rise  
(Hot start)  
For circuits such as these, please use a magnetic-hold type latching  
relay. If you need to use a single stable relay, use a sealed type relay  
that is not easily affected by ambient conditions and make a failsafe  
circuit design that considers the possibility of contact failure or  
disconnection.  
In DC relays, after continuous passage of current in the coil, if the  
current is turned OF
F
,
t
hen immediately turned ON again, due to the  
temperature rise in the coil, the pick-up voltage will become somewhat  
higher. Also, it will be the same as using it in a higher temperature  
atmosphere. The resistance/temperature relationship for copper wire  
is about 0.4% for 1°C, and with this ratio the coil resistance increases.  
That is, in order to operate of the relay, it is necessary that the voltage  
be higher than the pick-up voltage and the pick-up voltage rises in  
accordance with the increase in the resistance value. However, for  
some polarized relays, this rate of change is considerably smaller.  
DC Coil operating power  
Steady state DC current should be applied to the coil. The wave form  
should be rectangular. If it includes ripple, the ripple factor should be  
less than 5%.  
However, please check with the actual circuit since the electrical  
characteristics may vary. The rated coil voltage should be applied to  
the coil and the set/reset pulse time of latching type relay differs for  
each relays, please refer to the relay’s individual specifications.  
Coil connection  
When connecting coils of polarized relays, please check coil polarity  
(+,-) at the internal connection diagram (Schematic). If any wrong  
connection is made, it may cause
 
unexpected malfunction, like  
abnormal heat, fire and so on, and circuit do not work. Avoid  
impressing voltages to the set coil and reset coil at the same time.  
Ambient Environment  
Usage, Transport, and Storage Conditions  
Dew condensation  
During usage, storage, or transportation, avoid locations  
subjected to direct sunlight and maintain normal temperature,  
humidity and pressure conditions.  
Condensation occurs when the ambient temperature drops  
suddenly from a high temperature and humidity, or the relay is  
suddenly transferred from a low ambient temperature to a high  
temperature and humidity. Condensation causes the failures like  
insulation deterioration, wire disconnection and rust etc.  
Panasonic Corporation does not guarantee the failures caused  
by condensation.  
Temperature/Humidity/Pressure  
When transporting or storing relays while they are tube  
packaged, there are cases the temperature may differ from the  
allowable range. In this case be sure to check the individual  
specifications. Also allowable humidity level is influenced by  
temperature, please check charts shown below and use relays  
within mentioned conditions. (Allowable temperature values  
differ for each relays, please refer to the relay’s individual  
specifications.)  
The heat conduction by the equipment may accelerate the  
cooling of device itself, and the condensation may occur.  
Please conduct product evaluations in the worst condition of  
the actual usage. (Special attention should be paid when high  
temperature heating parts are close to the device. Also please  
consider the condensation may occur inside of the device.)  
Icing  
1)
T
e
mperature:  
Condensation or other moisture may freeze on relays when the  
temperature become lower than 0°C.This icing causes the sticking of  
movable portion, the operation delay and the contact conduction failure  
etc. Panasonic Corporation does not guarantee the failures caused by  
the icing.  
The tolerance temperature range differs for each relays,  
please refer to the relay’s individual specifications  
2) Humidity:  
5 to 85 % RH  
3) Pressure:  
86 to 106 kPa  
The heat conduction by the equipment may accelerate the cooling of  
relay itself and the icing may occur. Please conduct product  
evaluations in the worst condition of the actual usage.  
Low temperature and low humidity  
Humidity, %R.H.  
85  
The plastic becomes brittle if the switch is exposed to a low  
temperature, low humidity environment for long periods of time.  
High temperature and high humidity  
Allowable range  
(Avoid  
(Avoid icing  
condensation  
when used at  
when used at  
temperatures  
Storage for extended periods of time (including transportation periods)  
at high temperature or high humidity levels or in atmospheres with  
organic gases or sulfide gases may cause a sulfide film or oxide film to  
form on the surfaces of the contacts and/or it may interfere with the  
functions. Check out the atmosphere in which the units are to be  
stored and transported.  
temperatures  
lower than 0
°
C)  
higher than  
)
0
°
C  
5
–40  
0
85  
Ambient temperature,
°
C  
Panasonic Corporation Electromechanical Control Business Division  
industrial.panasonic.com/ac/e/  
c
Panasonic Corporation 2019  
ASCTB412E 201903  
-1-  

GUIDELINES FOR POWER RELAYS AND HIGH-CAPACITY DC CUT OFF RELAYS USAGE  
Package  
NOx Generation  
In terms of the packing format used, make every effort to keep the  
effects of moisture, organic gases and sulfide gases to the absolute  
minimum.  
When relay is used in an atmosphere high in humidity to switch a load  
which easily produces an arc, the NOx created by the arc and the  
water absorbed from outside the relay combine to produce nitric acid.  
This corrodes the internal metal parts and adversely affects operation.  
Avoid use at an ambient humidity of 85%RH or higher (at 20°C). If use  
at high humidity is unavoidable, please contact our sales  
representative.  
Silicon  
When a source of silicone substances (silicone rubber, silicone oil,  
silicone coating materials and silicone filling materials etc.) is used  
around the relay, the silicone gas (low molecular siloxane etc.) may be  
produced.  
This silicone gas may penetrate into the inside of the relay. When the  
relay is kept and used in this condition, silicone compound may adhere  
to the relay contacts which may cause the contact failure. Do not use  
any sources of silicone gas around the relay (Including plastic seal  
types).  
Others  
Cleaning  
1) Although the environmentally sealed type relay (plastic sealed type,  
etc.) can be cleaned, avoid immersing the relay into cold liquid (such  
as cleaning solvent) immediately after soldering. Doing so may  
deteriorate the sealing performance.  
2) Cleaning with the boiling method is recommended(The temperature  
of cleaning liquid should be 40°C or lower ).  
Avoid ultrasonic cleaning on relays. Use of ultrasonic cleaning may  
cause breaks in the coil or slight sticking of the contacts due to  
ultrasonic energy.  
Please refer to
“the latest product specifications”  
when designing your product.  
•Requests to customers:  
Panasonic Corporation Electromechanical Control Business Division  
industrial.panasonic.com/ac/e/  
c
Panasonic Corporation 2019  
ASCTB412E 201903  
-2-  

2019  
ASCTB180E-2 201903