PANASONIC-JE1XN-DC6V
| Part # | PANASONIC-JE1XN-DC6V |
| Download | PANASONIC-JE1XN-DC6V |
VDE
COM
P
ACT ECONOMICAL
POWER REL
A
Y
S
JE-X
REL
A
Y
S
FEATURES
• Compact size – Height Max. 18.7 mm
.736 inch
lower than JY relay (22.5 mm)
(.886 inch)
22
.866
14
.551
18.7
.736
• High contact capacity — 5A 125 V AC
• Safety-oriented between coil and contact terminals
• All plastic materials: UL flame retardance 94V-0
• VDE
,
T
ÜV also approved
mm
inch
TERMINAL L
A
YOUT
Distance of 9.16 mm
.360 inch
between common and coil termi-
nals and 8.9 mm
.350 inch
between contacts give room to the
land diameter width when the relay is mounted on PC board, and
allow design of patterns with insulation distances of 6 mm
.236
inch
between common and coil and 5.9 mm
.232 inch
between
contacts.
• 3 mm
.118 inch
or more insulation distance for close
mounting can be kept easily with JE-X relays.
0.9
.035
R1
R2
3 dia.
9.16
.118 dia.
.361
8.9
8.9
3
.350
.350
.118
6.16
3 dia.
N.O.
.243
.118 dia.
Coil
Coil
4.45
.175
In case of 3 mm
.118 inch
land
diameter
3 dia.
N.C.
N.O.
N.C.
N.O.
5.9
.118 dia.
.233
4.45
.175
1.3 dia.
.051 dia.
N.C.
COM
mm
inch
mm
inch
SPECIFICATIONS
Contact
Characteristics
Arrangement
1 Form A
1 Form C
Max. operating speed
Initial insulation resistance*
1
20 cpm (at 70
°
C)
Min. 100 M
Ω
(at 500 V DC)
Initial contact resistance, max.
(By voltage drop 6 V DC 1A)
100 m
Ω
Between open contacts
750 Vrms
Initial
Contact material
Silver alloy
breakdown
Between contacts and
coil
1,500 Vrms
voltage*
2
Nominal switching
capacity
5 A 30 V DC, 5 A 125 V AC,
3A 250 V AC
Surge voltage between coil
and contact*
3
Operate time*
4
(at nominal voltage)
Release time (without diode)*
4
(at nominal voltage)
Rating
Min. 5,000 V
Approx. 10 ms
Approx. 2 ms
Max. switching power
(resistive
750 VA, 150 W
250 V AC, 30 V DC
5 A
load)
Max. switching voltage
Max. switching current
Mechanical (at 180 cpm)
5
×
10
6
Expected
life (min.
operations)
Max. 45
°
C with nominal coil
voltage and at nominal
switching capacity
Electrical (at 20 cpm)
(at rated load)
10
5
T
e
mperature rise (at 70
°
C)
Coil
Functional*
5
Shock resistance
Min. 98 m/s
2
{10 G}
Min. 980 m/s
2
{100 G}
98 m/s
2
{10 G}, 10 to 55 Hz
at double amplitude of 1.6 mm
117.6 m/s
2
{12 G}, 10 to 55 Hz
at double amplitude of 2.0 mm
Destructive*
6
Minimum operating power
Nominal operating power
Remarks
196 mW
400 mW
Functional*
7
Vibration resistance
* Specifications
will vary with foreign standards certification ratings.
*
1
Measurement at same location as “Initial breakdown voltage” section
*
2
Detection current: 10 mA
Destructive
*
3
Wave is standard shock voltage of
1.2
×
50
µ
s according to JEC-212-1981
*
4
Excluding contact bounce time
Conditions for operation,
transport and storage*
8
(Not freezing and condens-
ing at low temperature)
Ambient
temp.
–40
°
C to +70
°
C
–40
°
F to +158
°
F
*
5
Half-wave pulse of sine wave: 6ms; detection time: 10
µ
s
*
6
Half-wave pulse of sine wave: 6ms
Humidity
5 to 85% R.H.
*
7
Detection time: 10
µ
s
Unit weight
Approx. 9.2g
.32 oz
*
8
Refer to
6
. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT.
All Rights Reserved © C
OPYRIGHT
Matsushita Electric Works, Ltd.
JE-X
TYPICAL
ORDERING INFORMATION
APPLICATIONS
Ex. JE
1
X
N
DC12V
H
• Home appliances
Oven, range, dryer, heater,
Air conditioner etc.
Protective
construction
Contact arrangement
Pick-up voltage
Coil voltage
• Automotive
1a: 1 Form A
1:1 Form C
N:70% of nominal voltage
DC 5, 6, 9,
H: Flux-resistant type
12, 24, 48 V
• Garage door opener
• Personal computer
• Programmable controller
(Note) Standard
packing: Carton
100 pcs.
Case 500 pcs.
UL/CSA, VDE approved type is standard.
TYPES
Pick-up 70% V type
Flux-resistant type
JE1aXN-DC5V-H
JE1aXN-DC6V-H
JE1aXN-DC9V-H
JE1aXN-DC12V-H
JE1aXN-DC24V-H
JE1aXN-DC48V-H
JE1XN-DC5V-H
JE1XN-DC6V-H
JE1XN-DC9V-H
JE1XN-DC12V-H
JE1XN-DC24V-H
JE1XN-DC48V-H
Contact arrangement
Coil voltage
5 V DC
6 V DC
9 V DC
12 V DC
24 V DC
48 V DC
5 V DC
6 V DC
9 V DC
12 V DC
24 V DC
48 V DC
1 Form A
1 Form C
COIL DATA (at 20
°
C
68
°
F
)
Nominal operating
currrent,
Nominal operating
Maximum
allowable voltage,
V DC (at 70
°
C)
Nominal voltage,
V DC
Pick-up voltage,
V DC (max.)
Drop-out voltage,
V DC (min.)
Coil resistance,
power,
mW
Ω
( 10%)
mA (
10%)
5
6
3.5
4.2
0.5
0.6
0.9
1.2
2.4
4.8
80
67
44
33
17
8.3
62.5
90
400
400
400
400
400
400
6.5
7.8
9
6.3
202
11.7
15.6
31.2
62.4
12
24
48
8.4
360
16.8
33.6
1,440
5,760
mm
inch
DIMENSIONS
PC board pattern (Bottom view)
14
5-1.3 dia.
.551
5-.051 dia.
7.62
.300
7.62
.300
4.45
.175
4.45
.175
22
.866
10.16
.400
Max.
18.2
.717
T
o
lerance: 0.1
.004
0.5
Schematic (Bottom view)
.020
N.O.
4
3.9
.154
1
COM
3
0.8
0.3
0.8
.031
.031
.012
3.9
5
N.C.
.154
7.62
.300
7.62
.300
2
Note: The above shows 1 Form C type, and No. 5
terminal is eliminated on the 1 Form A type.
N.O.
4
1.2
.047
COM
1
2
4.45
.175
3
10.16
.400
4.45
.175
Dimension:
General tolerance
N.C.
5
Max. 1mm
.039 inch
:
1 to 5mm
.039 to .197 inch
: 0.3
.012
Min. 5mm
.197 inch
: 0.4
.016
0.2
.008
0.4
1.1
.043
.016
All Rights Reserved © C
OPYRIGHT
Matsushita Electric Works, Ltd.
JE-X
REFERENCE DATA
1. Max. switching power
2. Operate and release time
3. Coil temperature rise (at 30
°
C
86
°
F
)
15
5A
5
3A
1.5A
0A
60
50
40
30
20
3
AC resistive load
10
DC resistive
load
1
Operate time
0.5
Max.
Min.
5
0
Release time
Max.
Min.
80
100
120
100 110
130
150
30 50
100
20
0
2
50
Voltage, V
Coil applied voltage, %V
Coil applied voltage, %V
4. Coil temperature rise
5. Life curve
(Contact carrying current: 5 A)
100
70
30
°
C
40
°
C
60
50
40
30
125V AC
resistive load
60
°
C
10
250V AC
resistive load
1
0
1
2
3
4
5
6
100 110
130
150
Contact current, A
Coil applied voltage, %V
NOTE
Soldering should be carried out within 3 s
at 350
°
C
662
°
F
or within 5 s at 250
°
C
482
°
F
.
For Cautions for Use, see Relay Technical Information.