PANASONIC-JJM1-12V

Part #PANASONIC-JJM1-12V
Download 
PANASONIC-JJM1-12V
COMPACT SIZE  
AUTOMOTIVE REL
A
Y  
JJ-M RELAYS  
FEATURES  
TYPICAL APPLICATIONS  
• Compact size  
• Power windows  
• Perfect for automobile electrical  
systems  
Over 2
10

5

openings possible with a  
14 V DC motor load, an inrush current  
of 25 A, and steady state current of 5 A.  
(N.O. side)  
• Auto door lock  
• Electrically powered sun roof  
• Electrically powered mirror  
• Cornerring lamp, etc.  
• Standard terminal pitch employed  
The terminal array used is identical to  
that used in small automotive relays.  
• Plastic sealed type.  
Plastically sealed for automatic  
cleaning.  
• Line-up of 1 Form A and 1 Form C  
ORDERING INFORMATION  
JJM  
Contact arrangement  
1: 1
 
Form C  
1a: 1 Form A  
Coil voltage (DC)  
12 V  
TYPES  
Contact arrangement  
Coil voltage  
12 V DC  
Part No.  
1 Form A  
JJM1a-12V  
JJM1-12V  
1 Form C  
12 V DC  
Standard packing; Carton (tube): 50 pcs.; Case: 1,000 pcs.  
RATING  
1. Coil data  
Nominal operating  
current  
[
10%] (at 20
C
68
F
)  
Nominal operating  
power  
(at 20
C
68
F
)  
Nominal coil  
voltage  
Pick-up voltage  
(at 20
C
68
F
)  
Drop-out voltage  
(at 20
C
68
F
)  
Coil resistance  
[
10%] (at 20
C
68
F
)  
Usable voltage range  
10 to 16V DC  
Max. 7.2 V DC  
(Initial)  
Min. 1.0 V DC  
(Initial)  
12V DC  
53.3 mA  
225
  
640 mW  
Note: Other pick-up voltage types are also available. Please contact us for details.  
ds_61210_en_jjm: 010113J  
1

JJ-M  
2. Specifications  
Characteristics  
Item  
Specifications  
Arrangement  
1 Form A  
1 Form C  
Contact  
Contact resistance (Initial)  
Contact material  
Typ 5m
(By voltage drop 6V DC 1A)  
Ag alloy (Cadmium free)  
Nominal switching capacity  
(resistive load)  
N.O.: 20 A 14V DC  
N.C.: 10 A 14V DC  
20 A 14V DC  
N.O.: 35 A (at 20
C
68
F
for 2 minutes), 25 A (at 20
C
68
F
for 1 hour),  
30 A (at 85
C
185
F
for 2 minutes), 20 A (at 85
C
185
F
for 1 hour)  
Max. carrying current (12V DC)*

3  

Rating  
Nominal operating power  
640 mW  
Min. switching capacity  
(resistive load)*

1  

1 A 12V DC  
Insulation resistance (Initial)  
Between open  
Min. 100 M
(at 500V DC, Measurement at same location as “Break down voltage” section)  
500 Vrms for 1 min. (Detection current: 10mA)  
contacts  
Breakdown  
Electrical  
characteristics  
voltage (Initial)  
Between contacts  
and coil  
500 Vrms for 1 min. (Detection current: 10mA)  
Operate time (at nominal voltage)  
Release time (at nominal voltage)  
Max. 10ms (at 20
C
68
F
, excluding contact bounce time) (Initial)  
Max. 10ms (at 20
C
68
F
, excluding contact bounce time) (Initial)  
Min. 100 m/s

2

{10G} (Half-wave pulse of sine wave: 11ms; detection time: 10
s)  
Min. 1,000 m/s

2

{100G} (Half-wave pulse of sine wave: 6ms)  
10 Hz to 100 Hz, Min. 44.1 m/s

2

{4.5G} (Detection time: 10
s)  
10 Hz to 500 Hz, Min. 44.1 m/s

2

{4.5G},  
Time of vibration for each direction; X, Y direction: 2 hours, Z direction: 4 hours  
Functional  
Shock  
resistance  
Destructive  
Functional  
Mechanical  
characteristics  
Vibration  
resistance  
Destructive  
Mechanical  
Electrical  
Min. 10

7

(at 120 cpm)  
<Resistive load>  
<Resistive load>  
N.O.: Min. 10

5

(at nominal switching capacity)  
N.C.: Min. 10

5

(at nominal switching capacity)  
(operating frequency: 1s ON, 9s OFF)  
<Motor load>  
N.O.: Min. 2
10

5

(at Inrush 25A, Steady 5A 14 V DC),  
Min. 5
10

4

(at 20A 14 V DC motor lock)  
N.C.: Min. 2
10

5

(at 20A 14 V DC brake currect)  
(operating frequency: 0.5s ON, 9.5s OFF)  
Min. 10

5

(at nominal switching capacity)  
(operating frequency: 1s ON, 9s OFF)  
<Motor load>  
Expected life  
Conditions  
Min. 2
10

5

(at Inrush 25A, Steady 5A 14 V DC)  
Min. 5
10

4

(at 20A 14 V DC motor lock)  
(operating frequency: 0.5s ON, 9.5s OFF)  
Conditions for operation, transport and  
storage*

2  

Ambient temperature: –40
C to +85
C
–40
F to +185
F
,  
Humidity: 5% R.H. to 85% R.H. (Not freezing and condensing at low temperature)  
Max. operating speed  
6 cpm (at nominal switching capacity)  
Mass  
Approx. 5g
.176 oz  
Notes:  
*1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load.  
*2. The upper operation ambient temperature limit is the maximum temperature that can satisfy the coil temperature rise value. Refer to “6. Usage, Storage and Transport  
Please inquire if you will be using the relay in a high temperature atmosphere (110
C
230
F
).  
*3. Depends on connection conditions. Also, this does not guarantee repeated switching. We recommend that you confirm operation under actual conditions.  
REFERENCE DATA  
1. Coil temperature rise  
2. Max. switching capability  
(Resistive load, initial)  
3. Ambient temperature and operating voltage  
range  
Sample: JJM1-12
V
, 6pcs  
Point measured: Inside the coil  
Contact current: Non current through  
contact, 5A, 10A, 15A, 20A  
Resistance method, ambient temperature 85
C
185
F  
(N.O. side: room temperature)  
120  
40  
35  
60  
50  
40  
20A  
100  
80  
30  
25  
20  
15  
10  
15A  
10A  
5A  
60  
40  
20  
0
30  
20  
Non current  
through  
contact  
10  
0
5
Pick-up voltage  
(cold start)  
0
−
40
−
20  
0
20 40 60
8085
100 120  
12  
14  
16  
0
10  
20  
30  
40  
50  
Switching current, A  
Ambient temperature,
°
C  
Coil applied voltage, V  
ds_61210_en_jjm: 010113J  
2

JJ-M  
4. Distribution of pick-up and drop-out voltage  
Sample: JJM1-12
V
, 100pcs  
5. Distribution of operate time  
Sample: JJM1-12
V
,
1
00pcs  
6. Distribution of release time  
Sample: JJM1-12V, 100pcs  
* Without diode  
70  
70  
60  
50  
40  
30  
20  
10  
0
70  
60  
50  
40  
30  
20  
10  
0
Pick-up voltage  
Drop-out voltage  
60  
50  
40  
30  
20  
10  
0
0
0.5 1.0 1.5 2.0 2.5 3.0 3.5  
Time, ms  
1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0  
0
0.5 1.
0
1
.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5  
Voltage, V  
Time, ms  
7-(1). Electrical life test (at resistive load)  
Sample: JJM1-12V  
Quantity: n = 6 (NC = 3, NO = 3)  
Load: Resisitive load (NC side: 10A 14 V DC, NO  
side: 20 A 14 V DC); Operating frequency: ON 1s,  
OFF 9s  
Ambient temperature: Room temperature  
7
Contact welding: 0 time  
Miscontact: 0 time  
Max.  
X
Min.  
6
5
4
Pick-up voltage  
3
Drop-out voltage  
Max.  
2
1
0
X
Min.  
0
5
10  
No. of operations,
×
10

4  

7-(2). Electrical life test (Motor free)  
Sample: JJM1-12
V
, 6pcs.  
Change of pick-up and drop-out voltage  
Change of contact resistance  
Load: Inrush 25A, Steady 5A, Brake current 18A 14V  
DC, Power window motor load (Free condition).  
Operating frequency: ON 0.5s, OFF 9.5s  
50  
8
Contact welding: 0 time  
N.C. side  
Ambient temperature: Room temperature  
Miscontact: 0 time  
7
N.O. side  
40  
Max.  
X
6
Min.  
Circuit :  
5
30  
20  
Pick-up voltage  
Tested sample  
4
Max.  
Drop-out voltage  
3
2
1
0
Max.  
X
X(N.C.)  
Min.  
Min.  
Max.  
10  
0
X(N.O.)  
M
Min.  
20  
0
10  
0
5
10  
No. of operations,
×
10

4  

No. of operations,
×
10

4  

7-(3). Electrical life test (Motor lock)  
Change of pick-up and drop-out voltage  
Change of contact resistance  
Sample: JJM1-12
V
, 6pcs.  
Load: 20A, 14VDC,  
50  
40  
30  
7
Power window motor actual load (lock condition).  
Operating frequency: ON 1s, OFF 5s  
Ambient temperature: Room temperature  
Contact welding: 0 time  
N.C. side  
N.O. side  
Miscontact: 0 time  
6
Max.  
X
Min.  
5
4
3
2
Pick-up voltage  
Drop-out voltage  
Circuit :  
Tested sample  
Max.  
X
20  
10  
0
Min.  
Max.  
Max.  
1
0
M
X(N.C.)  
X(N.O.)  
Min.  
0
2.5  
No. of operations,
×
10

4  

5
0
2.5  
5
No. of operations,
×
10

4  

ds_61210_en_jjm: 010113J  
3

JJ-M  
7-(4). Electrical life test (Lamp load)  
Change of pick-up and drop-out voltage  
Change of contact resistance  
Sample: JJM1-12
V
, 6pcs.  
Load: 27W+21W, steady min. 4A, Lamp actual load  
Operating frequency: ON 2s, OFF 13s  
Ambient temperature: Room temperature  
10  
9
50  
40  
N.C. side  
N.O. side  
8
Pick-up voltage  
Drop-out voltage  
7
6
Max.  
X
Circuit :  
30  
20  
Min.  
5
4
3
2
Max.  
Max.  
Max.  
X
10  
0
X(N.O.)  
X(N.C)  
Min.  
Min.  
1
0
Min.  
0
5
10  
0
5
10  
No. of operations,
×
10

4  

No. of operations,
×
10

4  

Load current waveform  
Inrush current: 42A, Steady current: 4.4A  
10A  
10ms  
DIMENSIONS
(mm
inch
)  

Download

from our Web site.  
External dimensions  
Schematic (Bottom view)  
1a  
PC board pattern (Bottom view)  
1a  
15.5  
.610  
12  
.472  
3-1.4 dia.  
NO  
3-.055 dia.  
COM  
13.9  
.547  
COIL  
0.4  
10.0  
.394  
1.5 dia.  
.016  
.059 dia.  
3.5  
.138  
2.5  
.098  
10.2  
.402  
A
2-0.3  
2-0.4  
2-.012  
2-.016  
1c  
1c  
10.0 1.2  
.394 .047  
4-1.4 dia.  
NO  
4-.055 dia.  
COM  
0.3  
.012  
2.5  
.098  
4-1.0  
COIL  
NC  
4-.039  
10.0  
.394  
1.5 dia.  
.059 dia.  
0.3  
10.2  
.402  
1.6  
.012  
.063  
2.5  
.098  
10.2  
.402  
* Dimensions
 
(thickness and width) of terminal is measured before pre-soldering.  
Intervals between terminals is measured at A surface level.  
T
o
lerance:
0.1
.004  
Dimension:  
General tolerance  
Max. 1mm
.039 inch
:  
0.1
.004  
1 to 3mm
.039 to .118 inch
:
0.2
.008  
Min. 3mm
.118 inch
:  
0.3
.012  
Note:  
Marked terminal is only for 1 Form C type  
For Cautions for Use, see
 

ds_61210_en_jjm: 010113J  
4