PANASONIC-JK1A-12V
| Part # | PANASONIC-JK1A-12V |
| Download | PANASONIC-JK1A-12V |
VDE
SLIM TYPE POWER REL
A
Y
FEATURES
JK REL
A
Y
S
11
.433
• Compact & Slim design: 11.0 mm (length)
×
21.4 mm (width)
×
15.7 mm (height)
(.433
×
.843
×
.618 inch)
21.4
.843
15.7
.618
• High capacity type (8 A) available
• Surge resistance: Min. 8,000 V between contact and coil
• High sensitivity: 200 mW nominal operating power
• Sealed type available
• VDE
,
T
Ü
V
,
S
EMKO also approved
mm
inch
SPECIFICATIONS
Contact
Characteristics
High capacity
type
Max. operating speed
Initial insulation resistance*
1
20 cpm
T
y
pe
Standard type
Min. 100 M
Ω
at 500 V DC
750 Vrms for 1 min.
Arrangement
1 Form A
Initial
Between open contacts
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A)
breakdown
100 m
Ω
Between contact and coil
2,000 Vrms for 1 min.
voltage*
2
Contact material
Silver alloy
Surge voltage between contact and coil*
3
Operate time*
4
(at nominal voltage)
Min. 8,000 V
Approx. 4 ms
Nominal switching
3 A 30 V DC
5 A 30 V DC
capacity
Rating
3 A 125 V AC
8 A 125 V AC
Release time*
4
(at nominal voltage)
(without diode)
Approx. 2 ms
90 W,
500 VA
150 W,
1,250 V A
Max. switching power
(resistive
load)
Max. 45
°
C with nominal coil
voltage and at maximum
allowable contact current
Min. 98 m/s
2
{10 G}
Min. 980 m/s
2
{100 G}
T
e
mperature rise
(ambient temperature: 70
°
C)
Max. switching voltage
Max. switching current
Mechanical (at 180 cpm)
250 V AC, 110 V DC (0.3 A)
3 A
8 A
Functional*
5
Shock resistance
5
×
10
6
Expected
life (min.
operations)
Destructive*
6
Electrical (at 20 cpm)
(at rated load)
10
5
10 to 55 Hz at double
amplitude of 1.6 mm
Functional*
7
Vibration resistance
Coil
10 to 55 Hz at double
amplitude of 2 mm
Destructive
Nominal operating
power
Standard and high capacity type
200 mW
Conditions for operation,
transport and storage*
8
(Not freezing and condensing
at low temperature)
Ambient
temp.
–40
°
C to +70
°
C
–40
°
F to +158
°
F
Remarks
* Specifications
will vary with foreign standards certification ratings.
*
1
Measurement at same location as “Initial breakdown voltage” section
*
2
Detection current: 10 mA
Humidity
5 to 85% R.H.
*
3
Wave is standard shock voltage of
1.2
×
50
µ
s according to JEC-212-1981
*
4
Excluding contact bounce time
Unit weight
Approx. 7 g
.25 oz
*
5
Half-wave pulse of sine wave: 11ms; detection time: 10
µ
s
*
6
Half-wave pulse of sine wave: 6ms
*
7
Detection time: 10
µ
s
*
8
Refer to 5. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT.
TYPICAL APPLICATIONS
ORDERING INFORMATION
• Home appliances
Ex. JK 1a
P
F
12 V
Microwave ovens, Air conditioners
• Office equipment
Photocopiers, Facsimiles
• Industrial machines
NC machines
Protectiive
constructiion
Coil voltage
(DC)
Contact capacity
Nil: Standard 3 A
P: High capacity
8A
Nil: Sealed type
F: Flux-resis-
tant type
3, 5, 6, 9, 12, 18,
24, 48 V
Notes: 1.
For TV-5 rated type, add sufix “-TV”.
1.
For detailed specifications, please consult us.
2. Standard packing: Carton: 100 pcs.; Case: 500 pcs.
UL/CSA, VDE approved type is standard.
All Rights Reserved
©
C
OPYRIGHT
Matsushita Electric Works, Ltd.
JK
TYPES
1. Standard type (3 A)
2. High capacity type (8 A)
Part No.
Flux-resistant type
Part No.
Flux-resistant type
Coil voltage,
V DC
Coil voltage,
V DC
Sealed type
JK1a-3V
Sealed type
JK1aP-3V
JK1aP-5V
JK1aP-6V
JK1aP-9V
JK1aP-12V
JK1aP-18V
JK1aP-24V
JK1aP-48V
3
5
JK1aF-3V
JK1aF-5V
JK1aF-6V
JK1aF-9V
JK1aF-12V
JK1aF-18V
JK1aF-24V
JK1aF-48V
3
5
JK1aPF-3V
JK1aPF-5V
JK1aPF-6V
JK1aPF-9V
JK1aPF-12V
JK1aPF-18V
JK1aPF-24V
JK1aPF-48V
JK1a-5V
6
JK1a-6V
6
9
JK1a-9V
9
12
18
24
48
JK1a-12V
JK1a-18V
JK1a-24V
JK1a-48V
12
18
24
48
COIL DATA (at 20
°
C
68
°
F
)
Nominal operating
Nominal operating
Max. allowable
voltage at 70
°
C,
V DC
Nominal voltage,
V DC
Pick-up voltage
V DC (max.)
Drop-out voltage,
V DC (min.)
Coil resistance
Ω
( 10%)
current,
power,
mW
mA (
10%)
3
5
2.4
4.0
0.15
0.25
0.3
45
125
67
40
33
22
17
11
8.3
4.2
200
200
200
200
200
200
200
200
3.9
6.5
6
4.8
180
7.8
9
7.2
0.45
0.6
405
11.7
15.6
23.4
31.2
62.4
12
18
24
48
9.6
720
14.4
19.2
38.4
0.9
1,620
2,880
11,520
1.2
2.4
mm
inch
DIMENSIONS
PC board pattern (Bottom view)
21.4
.843
11
2-1.3 dia.
2-.051 dia.
2-0.9 dia.
2-.035 dia.
.433
15.4
.606
0.3
.012
4
.157
T
o
lerance: 0.1
.004
2.54
.100
15.24
.600
1.6
7.62
.300
.063
Dimension:
Max. 1mm
.039 inch
1 to 5mm .
039 to .197 inch
0.3
.012
General tolerance
0.2
.008
N.O.
2
1
COM
Min. 5mm
.197 inch
0.4
.016
REFERENCE DATA
1-(1). Maximum value for switching capacity
(Standard type)
1-(2). Maximum value for switching capacity
(High capacity type)
2. Operate/release time
100
100
8
6
AC resistive load
10
8
10
AC resistive load
3
Operate time
4
Max.
–
x
1
1
Max.
–
Min.
x
Min.
Release time
2
0
10
100 250
10
100 250
80 100
120 140 160 180
Coil applied voltage, %V
Contact voltage, V
Contact voltage, V
All Rights Reserved
©
C
OPYRIGHT
Matsushita Electric Works, Ltd.
JK
3. Coil temperature rise
(High capacity type)
4. Ambient temperature characteristics
(High capacity type)
Measured portion: Inside the coil
Contact current: 8 A
Contact current: 8 A
300
Allowable ambient temperatures
against % coil voltage (max.
inside the coil temperature
set as 115
°
C
239
°
F
)
80
60
40
20
0
Ambient
temperature
25
°
C
200
Ambient
temperature
70
°
C
Pick-up voltage with a hot-start
condition of 100%V on the coil
100
Pick-up voltage
0
80 100
120 140
160 180
Coil applied voltage, %V
20
40
60
80
Ambient temperature,
°
C
5.-(1) Life curve (Standard type)
5.-(2) Life curve (High capacity type)
Operation frequency: 20 times/min.
(ON/OFF = 1.5s:1.5s)
Ambient temperature: Room temperature
Operation frequency: 20 times/min.
(ON/OFF = 1.5s:1.5s)
Ambient temperature: Room temperature
100
100
125V AC
resistive load
125V AC
resistive load
10
10
250V AC
resistive load
250V AC
resistive load
1
1
0
1
2
3
4
2
3
4
5
6
7
8
9
Contact current, A
Contact current, A
For Cautions for Use, see Relay Technical Information.
All Rights Reserved
©
C
OPYRIGHT
Matsushita Electric Works, Ltd.