PANASONIC-JK1A-12V

Part #PANASONIC-JK1A-12V
Download 
PANASONIC-JK1A-12V
VDE  
SLIM TYPE POWER REL
A
Y  
FEATURES  
JK REL
A
Y
S  
11  
.433  
• Compact & Slim design: 11.0 mm (length)
×
21.4 mm (width)
×
15.7 mm (height)  
(.433
×
.843
×
.618 inch)  
21.4  
.843  
15.7  
.618  
• High capacity type (8 A) available  
• Surge resistance: Min. 8,000 V between contact and coil  
• High sensitivity: 200 mW nominal operating power  
• Sealed type available  
• VDE
,
T
Ü
V
,
S
EMKO also approved  
mm
inch  
SPECIFICATIONS  
Contact  
Characteristics  
High capacity  
type  
Max. operating speed  
Initial insulation resistance*

1  

20 cpm  
T
y
pe  
Standard type  
Min. 100 M
Ω
at 500 V DC  
750 Vrms for 1 min.  
Arrangement  
1 Form A  
Initial  
Between open contacts  
Initial contact resistance, max.  
(By voltage drop 6 V DC 1 A)  
breakdown  
100 m
Ω  
Between contact and coil  
2,000 Vrms for 1 min.  
voltage*

2  

Contact material  
Silver alloy  
Surge voltage between contact and coil*

3  

Operate time*

4

(at nominal voltage)  
Min. 8,000 V  
Approx. 4 ms  
Nominal switching  
3 A 30 V DC  
5 A 30 V DC  
capacity  
Rating  
3 A 125 V AC
 
8 A 125 V AC  
Release time*

4

(at nominal voltage)  
(without diode)  
Approx. 2 ms  
90 W,  
500 VA  
150 W,  
1,250 V A  
Max. switching power  
(resistive  
load)  
Max. 45
°
C with nominal coil  
voltage and at maximum  
allowable contact current  
Min. 98 m/s

2

{10 G}  
Min. 980 m/s

2

{100 G}  
T
e
mperature rise  
(ambient temperature: 70
°
C)  
Max. switching voltage  
Max. switching current  
Mechanical (at 180 cpm)  
250 V AC, 110 V DC (0.3 A)  
3 A  
8 A  
Functional*

5  

Shock resistance  
5
×
10

6  

Expected  
life (min.  
operations)  
Destructive*

6  

Electrical (at 20 cpm)  
(at rated load)  
10

5  

10 to 55 Hz at double  
amplitude of 1.6 mm  
Functional*

7  

Vibration resistance  
Coil  
10 to 55 Hz at double  
amplitude of 2 mm  
Destructive  
Nominal operating  
power  
Standard and high capacity type  
200 mW  
Conditions for operation,  
transport and storage*

8  

(Not freezing and condensing  
at low temperature)  
Ambient  
temp.  
–40
°
C to +70
°
C  
–40
°
F to +158
°
F  
Remarks  
* Specifications
 
will vary with foreign standards certification ratings.  
*

1

Measurement at same location as “Initial breakdown voltage” section  
*

2

Detection current: 10 mA  
Humidity  
5 to 85% R.H.  
*

3

Wave is standard shock voltage of
 
1.2
×
50
µ
s according to JEC-212-1981  
*

4

Excluding contact bounce time  
Unit weight  
Approx. 7 g
.25 oz  
*

5

Half-wave pulse of sine wave: 11ms; detection time: 10
µ
s  
*

6

Half-wave pulse of sine wave: 6ms  
*

7

Detection time: 10
µ
s  
*

8

Refer to 5. Conditions for operation, transport and storage mentioned in  
AMBIENT ENVIRONMENT.  
TYPICAL APPLICATIONS  
ORDERING INFORMATION  
• Home appliances  
Ex. JK 1a  
P
F
12 V  
Microwave ovens, Air conditioners  
• Office equipment  
Photocopiers, Facsimiles  
• Industrial machines  
NC machines  
Protectiive  
constructiion  
Coil voltage  
(DC)  
Contact capacity  
Nil: Standard 3 A  
P: High capacity  
8A  
Nil: Sealed type  
F: Flux-resis-  
tant type  
3, 5, 6, 9, 12, 18,  
24, 48 V  
Notes: 1.
 
For TV-5 rated type, add sufix “-TV”.  
1.
For detailed specifications, please consult us.  
2. Standard packing: Carton: 100 pcs.; Case: 500 pcs.  
UL/CSA, VDE approved type is standard.  
All Rights Reserved
©
C
OPYRIGHT
Matsushita Electric Works, Ltd.  

JK  
TYPES  
1. Standard type (3 A)  
2. High capacity type (8 A)  
Part No.  
Flux-resistant type  
Part No.  
Flux-resistant type  
Coil voltage,  
V DC  
Coil voltage,  
V DC  
Sealed type  
JK1a-3V  
Sealed type  
JK1aP-3V  
JK1aP-5V  
JK1aP-6V  
JK1aP-9V  
JK1aP-12V  
JK1aP-18V  
JK1aP-24V  
JK1aP-48V  
3
5
JK1aF-3V  
JK1aF-5V  
JK1aF-6V  
JK1aF-9V  
JK1aF-12V  
JK1aF-18V  
JK1aF-24V  
JK1aF-48V  
3
5
JK1aPF-3V  
JK1aPF-5V  
JK1aPF-6V  
JK1aPF-9V  
JK1aPF-12V  
JK1aPF-18V  
JK1aPF-24V  
JK1aPF-48V  
JK1a-5V  
6
JK1a-6V  
6
9
JK1a-9V  
9
12  
18  
24  
48  
JK1a-12V  
JK1a-18V  
JK1a-24V  
JK1a-48V  
12  
18  
24  
48  
COIL DATA (at 20
°
C
68
°
F
)  
Nominal operating
 
Nominal operating  
Max. allowable  
voltage at 70
°
C,  
V DC  
Nominal voltage,  
V DC  
Pick-up voltage  
V DC (max.)  
Drop-out voltage,  
V DC (min.)  
Coil resistance  
Ω
( 10%)  
current,  
power,  
mW  
mA (
 
10%)  
3
5
2.4  
4.0  
0.15  
0.25  
0.3  
45  
125  
67  
40  
33  
22  
17  
11  
8.3  
4.2  
200  
200  
200  
200  
200  
200  
200  
200  
3.9  
6.5  
6
4.8  
180  
7.8  
9
7.2  
0.45  
0.6  
405  
11.7  
15.6  
23.4  
31.2  
62.4  
12  
18  
24  
48  
9.6  
720  
14.4  
19.2  
38.4  
0.9  
1,620  
2,880  
11,520  
1.2  
2.4  
mm
inch  
DIMENSIONS  
PC board pattern (Bottom view)  
21.4  
.843  
11  
2-1.3 dia.  
2-.051 dia.  
2-0.9 dia.  
2-.035 dia.  
.433  
15.4  
.606  
0.3  
.012  
4
.157  
T
o
lerance: 0.1
.004  
2.54  
.100  
15.24  
.600  
1.6  
7.62  
.300  
.063  
Dimension:  
Max. 1mm
.039 inch  
1 to 5mm .
039 to .197 inch
 
0.3
.012  
General tolerance  
0.2
.008  
N.O.  
2
1
COM  
Min. 5mm
.197 inch  
0.4
.016  
REFERENCE DATA  
1-(1). Maximum value for switching capacity  
(Standard type)  
1-(2). Maximum value for switching capacity  
(High capacity type)  
2. Operate/release time  
100  
100  
8
6
AC resistive load  
10  
8
10  
AC resistive load  
3
Operate time  
4
Max.  
–
x
1
1
Max.  
–
Min.  
x
Min.  
Release time  
2
0
10  
100 250  
10  
100 250  
80 100
 
120 140 160 180  
Coil applied voltage, %V  
Contact voltage, V  
Contact voltage, V  
All Rights Reserved
©
C
OPYRIGHT
Matsushita Electric Works, Ltd.  

JK  
3. Coil temperature rise  
(High capacity type)  
4. Ambient temperature characteristics  
(High capacity type)  
Measured portion: Inside the coil  
Contact current: 8 A  
Contact current: 8 A  
300  
Allowable ambient temperatures  
against % coil voltage (max.  
inside the coil temperature  
set as 115
°
C
239
°
F
)  
80  
60  
40  
20  
0
Ambient  
temperature  
25
°
C  
200  
Ambient  
temperature  
70
°
C  
Pick-up voltage with a hot-start  
condition of 100%V on the coil  
100  
Pick-up voltage  
0
80 100
 
120 140
 
160 180  
Coil applied voltage, %V  
20  
40  
60  
80  
Ambient temperature,
°
C  
5.-(1) Life curve (Standard type)  
5.-(2) Life curve (High capacity type)  
Operation frequency: 20 times/min.  
(ON/OFF = 1.5s:1.5s)  
Ambient temperature: Room temperature  
Operation frequency: 20 times/min.  
(ON/OFF = 1.5s:1.5s)  
Ambient temperature: Room temperature  
100  
100  
125V AC  
resistive load  
125V AC  
resistive load  
10  
10  
250V AC  
resistive load  
250V AC  
resistive load  
1
1
0
1
2
3
4
2
3
4
5
6
7
8
9
Contact current, A  
Contact current, A  
For Cautions for Use, see Relay Technical Information.  
All Rights Reserved
©
C
OPYRIGHT
Matsushita Electric Works, Ltd.