PANASONIC-JQ1P-12V
| Part # | PANASONIC-JQ1P-12V |
| Download | PANASONIC-JQ1P-12V |
VDE
Partly to Be Discontinued:
10A type (Made in Thailand)
Last time buy: September 30, 2016
1a/1c 5A/10A small power
relays
JQ REL
A
Y
S
FEATURES
TYPICAL APPLICATIONS
• High electrical noise immunity
• High switching capacity in a compact
package
• Air conditioners
• Refrigerators
• Microwave ovens
• Heaters
• High sensitivity: 200 mW (1a),
400 mW (1c)
• High surge voltage: 8,000 V between
contacts and coil
• UL, CSA, VDE, SEMKO approved and
TÜV available
• Class B coil insulation type also
available.
RoHS compliant
ORDERING INFORMATION
JQ
F
Contact arrangement
1a: 1 Form A
1 :
1 Form C
Contact capacity
Nil: Standard (5A)
P: High
capacity (10A)
Coil insulation class
Nil: Class E coil insulation
B: Class
B coil insulation (UL)
Nominal coil voltage (DC)
5V, 6V, 9V, 12V, 18V, 24V, 48V*
Contact material
F: AgSnO
2
type
Certified by UL, CSA, VDE and SEMKO
Note: *Available only for 1 Form C type
TYPES
1) Standard type
Standard type
1 Form C
High capacity type
Nominal coil voltage
1 Form A
Part No.
1 Form A
Part No.
1 Form C
Part No.
Part No.
JQ1-5V-F
JQ1-6V-F
JQ1-9V-F
JQ1-12V-F
JQ1-18V-F
JQ1-24V-F
JQ1-48V-F
5V DC
6V DC
JQ1a-5V-F
JQ1a-6V-F
JQ1a-9V-F
JQ1a-12V-F
JQ1a-18V-F
JQ1a-24V-F
–
JQ1aP-5V-F
JQ1aP-6V-F
JQ1aP-9V-F
JQ1aP-12V-F
JQ1aP-18V-F
JQ1aP-24V-F
–
JQ1P-5V-F
JQ1P-6V-F
JQ1P-9V-F
JQ1P-12V-F
JQ1P-18V-F
JQ1P-24V-F
JQ1P-48V-F
9V DC
12V DC
18V DC
24V DC
48V DC
Standard packing: Carton 100 pcs., Case 500 pcs.
ASCTB185E 201509-T
–1–
Partly to Be Discontinued: 10A type (Made in Thailand)
Last time buy: September 30, 2016
JQ
RATING
1. Coil data
Drop-out
voltage
Nominal operating
current
Nomina
l
o
perating
power
(at 20
°
C
68
°
F
)
Contact
arrangement
Nominal coil
voltage
Pick-up voltage
(at 20
°
C
68
°
F
)
Coil resistance
[ 10%]
(at 20
°
C
68
°
F
)
Max. applied voltage
(at 20
°
C
68
°
F
) [
10%] (at 20
°
C
68
°
F
)
5V DC
6V DC
40.0mA
33.3mA
125
180
Ω
Ω
Ω
Ω
Ω
Ω
Standard type:
75%V or less of
nominal voltage (Initial)
5%V or more of
nominal voltage
High capacity type:
80%V or less of
nominal voltage (Initial)
180% of nominal voltage
(at 20
°
C
68
°
F
)
9V DC
22.2mA
16.7mA
11.1mA
8.3mA
405
1 Form A
200mW
400mW
130% of nominal voltage
(at 70
°
C
158
°
F
)
[When using relays at
85
°
C
185
°
F
, see Notes*4]
12V DC
18V DC
24V DC
5V DC
720
(Initial)
1,620
2,880
80 mA
66.7mA
44.4mA
33.3mA
22.2mA
16.7mA
8.3mA
62.5
Ω
90
202.5
Ω
360
810
Standard type:
75%V or less of
nominal voltage (Initial)
5%V or more of
nominal voltage
High capacity type:
80%V or less of
nominal voltage (Initial)
150% of nominal voltage
6V DC
Ω
(at 20
°
C
68
°
F
)
9V DC
1 Form C
12V DC
18V DC
24V DC
48V DC
Ω
Ω
Ω
Ω
110% of nominal voltage
(at 70
°
C
158
°
F
)
[When using relays at
85
°
C
185
°
F
, see Notes*4]
(Initial)
1,440
5,760
2. Specifications
Specifications
Characteristics
Item
Standard type
High capacity type
Arrangement
Contact resistance (Initial)
Contact material
1 Form A
1 Form C
1 Form A
1 Form C
Contact
Max. 100m
Ω
(By voltage drop 6 V DC 1 A)
AgSnO
2
type
N.O. side:
5 A 125 V AC,
N.O. side:
10 A 125 V AC,
5 A 250 V AC,
5 A 30 V AC
N.C. side:
3 A 125 V AC,
2 A 250 V AC,
1 A 30 V DC
2 A 250 V AC,
10 A 125 V AC,
3 A 30 V AC
5 A 250 V AC,
N.C. side:
5 A 125 V AC,
2 A 250 V AC,
5 A 30 V DC
Nominal switching capacity (resistive load)
Max. switching power (resistive load)
5 A 30 V DC
2 A 125 V AC,
1 A 250 V AC,
1 A 30 V DC
Rating
N.O. side:
N.O. side:
1,250 VA, 150 W
N.C. side:
625 VA, 90 W
1,250 V AC, 150 W
N.C. side:
625 VA, 150 W
250 VA, 30 W
500 V AC, 30 W
Max. switching voltage
250 V AC, 110 V DC (0.3A)
Max. switching current
N.O.: 5 A, N.C.: 2 A
200 mW
400 mW
N.O.: 10 A, N.C.: 3 A
200 mW
400 mW
Nominal operating power
Min. switching capacity (reference value)*
1
100 mA, 5 V DC
Min. 1,000 M
Ω
(at 500 V DC) Measurement at same location as “Breakdown voltage” section.
1,000 Vrms for 1 min.
750 Vrms for 1 min.
1,000 Vrms for 1 min.
750 Vrms for 1 min.
4,000 Vrms for 1 min. (Detection current: 10 mA)
Max. 45
°
C
113
°
F
Max. 45
°
C
113
°
F
Insulation resistance (Initial)
Between open contacts
Between contact and coil
Breakdown voltage
(Initial)
(By resistive method, nominal coil voltage
applied to the coil; contact carrying current:
5A, at 70
°
C
158
°
F
)
(By resistive method, nominal coil voltage
applied to the coil; contact carrying current:
10A, at 70
°
C
158
°
F
)
T
e
mperature rise (coil)
Electrical
characteristics
Surge breakdown voltage*
2
(Between contact and coil) (Initial)
8,000 V
Operate time (at nominal voltage) (at 20
°
C
68
°
F
)
(Initial)
Max. 20 ms (excluding contact bounce time.)
Release time (at nominal voltage) (at 20
°
C
68
°
F
)
(Initial)
Max. 10 ms (excluding contact bounce time) (Without diode)
Functional
Shock resistance
294 m/s
2
(Half-wave pulse of sine wave: 11 ms; detection time: 10
μ
s.)
980 m/s
2
(Half-wave pulse of sine wave: 6 ms.)
10 to 55 Hz at double amplitude of 1.6 mm (Detection time: 10
μ
s.)
10 to 55 Hz at double amplitude of 2.0 mm
Min. 10
7
Destructive
Mechanical
characteristics
Functional
Vibration resistance
Destructive
Expected life
Conditions
Unit weight
Mechanical (at 180 times/min.)
Conditions for operation, transport and storage*
3
Max. operating speed
Ambient temperature: –40
°
C to +70
°
C
–40
°
F to +158
°
F
(class E insulation),
–40
°
C to +85
°
C
–40
°
F to +185
°
F
*
4
(class B insulation)
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
20 times/min. (at nominal switching capacity)
Approx. 7 g
.25 oz
* Specifications will vary with foreign standards certification ratings.
Notes: *1. This value can change due to the switching frequenc
y
,
e
nvironmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load.
*2. Wave is standard shock voltage of
1.2
×
50
μ
s according to JEC-212-1981
*3. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage
conditions in NOTES.
*4. When using relays in a high ambient temperature, consider the pick-up voltage rise due to the high temperature (a rise of approx. 0.4% V for each 1
°
C
33.8
°
F
with
20
°
C
68
°
F
as a reference) and use a coil impressed voltage that is within the maximum applied voltage range.
ASCTB185E 201509-T
–2–
Partly to Be Discontinued: 10A type (Made in Thailand)
Last time buy: September 30, 2016
JQ
3. Expected electrical life
T
y
pe
Switching capacity
No. of operations
5 A 125 V AC
3 A 125 V AC
2 A 250 V AC
5 A 30 V DC
5
×
10
4
2
×
10
5
2
×
10
5
10
5
1 Form A
5 A 125 V AC
3 A 125 V AC
2 A 250 V AC
3 A 30 V DC
5
×
10
4
2
×
10
5
2
×
10
5
10
5
2
×
10
5
2
×
10
5
10
5
Standard type
N.O.
N.C.
1 Form C
2 A 125
V AC
1 A 250 V AC
1 A 30 V DC
10 A 125 V AC
5 A 250 V AC
5 A 30 V DC
5
×
10
4
5
×
10
4
10
5
1 Form A
10 A 125
V AC
5 A 250 V AC
5 A 30 V DC
5
×
10
4
5
×
10
4
10
5
2
×
10
5
2
×
10
5
10
5
High capacity type
N.O.
N.C.
1 Form C
3 A 125
V AC
2 A 250 V AC
1 A 30 V DC
REFERENCE DATA
1.-(1) Max. switching capacity (1 Form A type)
1.-(2) Max. switching capacity (1 Form C type)
100
100
AC resistive load
(High capacity type) N.O. side
AC resistive load
(Standard type) N.O. side
AC resistive load (High capacity type)
10
5
10
5
3
2
AC resistive load
AC resistive load (Standard type)
1
1
(High capacity type)
N.C. side
AC resistive load
(Standard type)
N.C. side
10
100 250
1,000
10
100 250
1,000
Contact voltage, V
Contact voltage, V
Standard type
2. Life curve
Ambient temperature: room temperature
3.-(1) Operate & release time (1 Form A type)
T
e
sted sample: JQ1a-12V-
F
,
2
5 pcs.
3.-(2) Operate & release time (1 Form C type)
T
e
sted sample: JQ1-24V-
F
,
2
5 pcs.
100
8
8
125V AC
resistive load
6
6
Operate time
Operate time
10
4
4
250V AC
resistive load
Max.
Max.
Max.
Max.
Min.
Min.
2
2
Min.
Min.
Release time
Release time
1
0
0
0
1
2
3
4
5
80
100
120
150
80
100
120
150
Contact current, A
Coil applied voltage, %V
Coil applied voltage, %V
ASCTB185E 201509-T
–3–
Partly to Be Discontinued: 10A type (Made in Thailand)
Last time buy: September 30, 2016
JQ
4.-(1) Coil temperature rise (1 Form A type)
4.-(2) Coil temperature rise (1 Form C type)
Contact carrying current: 3 A, 5 A
Measured portion: Inside the coil
Contact carrying current: 3 A, 5 A
Measured portion: Inside the coil
50
70
60
40
5 A at 70
°
C
5 A at 70
°
C
50
3 A at 70
°
C
5 A at 85
°
C
30
40
5 A at 85
°
C
30
20
3 A at 70
°
C
3 A at 85
°
C
20
3 A at 85
°
C
10
10
0
0
100 110 120 130 140 150 160 170 180 190
100 110 120 130 140 150 160
Coil applied voltage, %V
Coil applied voltage, %V
5.-(1) Ambient temperature characteristics
(1 Form A type)
5.-(2) Ambient temperature characteristics
(1 Form C type)
T
e
sted sample: JQ1a-24V-F
Contact carrying current: 3 A, 5 A
T
e
sted sample: JQ1-24V-F
Contact carrying current: 3 A, 5 A
1
Allowable ambient temperature against
% coil voltage (max. inside the coil temperature
set as 130
°
C
266
°
F
) (Carrying current: 3 A)
2
Allowable ambient temperature against
% coil voltage (max. inside the coil temperature
set as 130
°
C
266
°
F
) (Carrying current: 5 A)
400
400
300
300
1
3
Allowable ambient temperature against
% coil voltage (max. inside the coil temperature
set as 115
°
C
239
°
F
) (Carrying current: 3 A)
4
Allowable ambient temperature against
% coil voltage (max. inside the coil temperature
set as 115
°
C
239
°
F
) (Carrying current: 5 A)
1
2
2
200
200
3
3
4
5
5
6
4
100
100
5
Pick-up voltage with a hot-start condition
of 100%V on the coil (Carrying current: 5 A)
6
7
7
6
Pick-up voltage with a hot-start condition
of 100%V on the coil (Carrying current: 3 A)
0
0
20 30 40 50 60 70 80 90
20 30 40 50 60 70 80 90
7
Pick-up voltage
Ambient temperature,
°
C
Ambient temperature,
°
C
High capacity type
1. Life curve
Ambient temperature: room temperature
2.-(1) Operate & release time (1 Form A type)
T
e
sted sample: JQ1aP-12V-
F
,
2
5 pcs.
2.-(2) Operate & release time (1 Form C type)
T
e
sted sample: JQ1P-12V-
F
,
2
5 pcs.
100
8
6
8
6
4
2
0
Operate time
125V AC resistive load
10
Operate time
4
Max.
Min.
Max.
Min.
Max.
Max.
250V AC resistive load
Min.
Min.
2
0
Release time
120
Release time
120
1
80
100
150
0
2
4
6
8
10
80
100
150
Contact current, A
Coil applied voltage, %V
Coil applied voltage, %V
3.-(1) Coil temperature rise (1 Form A type)
3.-(2) Coil temperature rise (1 Form C type)
Contact carrying current: 5 A, 10 A
Measured portion: Inside the coil
Contact carrying current: 5 A, 10 A
Measured portion: Inside the coil
70
70
10 A at 85
°
C
60
60
10 A at 85
°
C
10 A at 70
°
C
50
50
10 A at 70
°
C
5 A at 70
°
C
40
40
5 A at 85
°
C
30
20
10
0
5 A at 70
°
C
30
5 A at 85
°
C
20
10
0
100
120
140
160
180
100 110 120 130 140 150 160
Coil applied voltage, %V
Coil applied voltage, %V
ASCTB185E 201509-T
–4–
Partly to Be Discontinued: 10A type (Made in Thailand)
Last time buy: September 30, 2016
JQ
4.-(1) Ambient temperature characteristics
(1 Form A type)
4.-(2) Ambient temperature characteristics
(1 Form C type)
T
e
sted sample: JQ1aP-24V-F
Contact carrying current: 5 A, 10 A
T
e
sted sample: JQ1P-24V-F
Contact carrying current: 5 A, 10 A
1
Allowable ambient temperature against
% coil voltage (max. inside the coil temperature
set as 130
°
C
266
°
F
) (Carrying current: 5 A)
2
Allowable ambient temperature against
% coil voltage (max. inside the coil temperature
set as 130
°
C
266
°
F
) (Carrying current: 10 A)
400
400
300
1
2
300
3
Allowable ambient temperature against
% coil voltage (max. inside the coil temperature
set as 115
°
C
239
°
F
) (Carrying current: 5 A)
4
Allowable ambient temperature against
% coil voltage (max. inside the coil temperature
set as 115
°
C
239
°
F
) (Carrying current: 10 A)
1
2
200
200
100
3
3
4
5
4
5
100
5
Pick-up voltage with a hot-start condition
of 100%V on the coil (Carrying current: 10 A)
6
7
6
7
6
Pick-up voltage with a hot-start condition
of 100%V on the coil (Carrying current: 5 A)
0
20 30 40 50 60 70 80 90
0
20 30 40 50 60 70 80 90
7
Pick-up voltage
Ambient temperature,
°
C
Ambient temperature,
°
C
The CAD data of the products with a
CAD Data
mark can be downloaded from: http://industrial.panasonic.com/ac/e/
DIMENSIONS
(mm
inch
)
External dimensions
Schematic (Bottom view)
1 Form C
CAD Data
1 Form A
1 Form A
10
20
COM N.O.
COM N.O.
.394
.787
Coil
Coil
15.6
.614
N.C.
0.4
.016
4.2
.165
7.62
.300
10.16
.400
0.3
7.62
.300
7.62
.300
0.8
0.5 dia.
0.3
.020 dia.
.012
.012
.031
PC board pattern (Bottom view)
1FormC
1 Form C
1 Form A
10
20
.787
4-1.3 dia.
5-1.3 dia.
.394
4-.051 dia.
5-.051 dia.
10.16
.400
7.62
.300
10.16
.400
7.62
.300
15.6
.614
7.62
.300
7.62
.300
0.4
.016
2.54
.100
4.2
5.08
.200
2.54
.100
7.62
.300
10.16
7.62
.300
.165
.400
0.3
T
o
lerance: 0.1
.004
0.5 dia.
0.3
0.8
.031
.020 dia.
.012
.012
0.3
.012
Dimension:
Less than 1mm
.039inch
:
General tolerance
0.2
.008
Min. 1mm
.039inch
less than 5mm
.197 inch
: 0.3
.012
Min. 5mm
.197 inch
: 0.4
.016
ASCTB185E 201509-T
–5–
Partly to Be Discontinued: 10A type (Made in Thailand)
Last time buy: September 30, 2016
JQ
SAFETY STANDARDS
UL/C-UL (Recognized)
Item
CSA (Certified)
File No.
Contact rating
VDE (Certified)
Contact rating
TÜV (Certified)
Rating
5A 250V AC (cos
φ
=0.4)
13461 296
5A 30V DC (0ms)
SEMKO (Certified)
File No.
Contact rating
File No.
Contact rating
File No.
File No.
B 11 04
Standard type
(5A) 1 Form A
E43028
5A 125V AC
5A 277V AC
5A 30V DC
0.3A 110V DC
1
/
10
HP 125V AC
1
/
6
HP 277V AC
LR26550
LR26550
LR26550
LR26550
5A 125V AC
5A 277V AC
5A 30V DC
0.3A 110V DC
1
/
10
HP 125V AC
1
/
6
HP 277V AC
40011435 5A
250V AC (cos
φ
=0.4)
817138
3(2)A 125V AC
2(1)A 250V AC
5A 30V DC
Standard type
(5A) 1 Form C
E43028
5A 125V AC
5A 277V AC
5A 30V DC
0.3A 110V DC
1
/
10
HP 125V AC
1
/
6
HP 277V AC
5A 125V AC
5A 277V AC
5A 30V DC
0.3A 110V DC
1
/
10
HP 125V AC
1
/
6
HP 277V AC
40011435 5A
250V AC (cos
φ
=0.4)
(N.O.)
B 11 04
5A 250V AC (cos
φ
=0.4)
13461 296
5A 30V DC (0ms)
817138
3(2)A 125V AC
2(1)A 250V AC
5A 30V DC
3A 250V AC (cos
φ
=0.4)
(N.C.)
High capacity type
E43028
(10A) 1 Form A
10A 125V AC
8A 277V AC
5A 30V DC
0.3A 110V DC
1
/
6
HP 125V AC
1
/
6
HP 277V AC
10A 125V AC
8A 277V AC
5A 30V DC
0.3A 110V DC
1
/
6
HP 125V AC
1
/
6
HP 277V AC
40011435 10A
250V AC (cos
φ
=0.4) B
11 04
10A 250V AC (cos
φ
=0.4) 817138
13461 296
5A 30V DC (0ms)
5(3)A 250V AC
5A 30V DC
High capacity type
E43028
(10A) 1 Form C
10A 125V AC
8A 277V AC
5A 30V DC
10A 125V AC
8A 277V AC
5A 30V DC
40011435 (N.O.)
B 11 04
10A 250V AC (cos
φ
=0.4) 817138
5(3)A 250V AC
5A 30V DC
10A 250V AC (cos
φ
=0.4) 13461
296 5A
30V DC (0ms)
(N.C.)
0.3A 110V DC
1
/
6
HP 125V AC
1
/
6
HP 277V AC
0.3A 110V DC
1
/
6
HP 125V AC
1
/
6
HP 277V AC
3A 250V AC (cos
φ
=0.4)
NOTES
Note about relay installation orientation
When installing with the relay terminals parallel to the ground, the contact terminals at
the bottom and the coil terminals at the top, component friction will occur after
numerous switching actions or due to vibration in the non-excitation state.
Since this may cause the relay to stop functioning when the pick-up voltage increases
even if the nominal voltage is applied, please do not install using this orientation.
T
o
p
Bottom
For Cautions for Use.
ASCTB185E 201509-T
–6–