PANASONIC-JW2ASN-DC12V

Part #PANASONIC-JW2ASN-DC12V
Download 
PANASONIC-JW2ASN-DC12V
Power relays ( Over 2 A )  
JW RELAYS  
Product Catalog  
2022.4  

Power relays (Over 2 A)  
REL
A
Y
S  
JW  
1 Form A/1 Form C/2 Form A/2 Form C, 5 A/10 A, Power relays  
FEATURES  
Protective construction
:
Flux-resistant/Sealed  
Miniature/slim:  
12.8 mm(W) × 28.6 mm(L) × 20 mm(H)  
Standard type (5 A) and high capacity type (10 A) are  
available  
PC board sockets are available  
12.8  
28.6  
20  
TYPICAL APPLICATIONS  
Home appliance  
Office machine  
Industrial equipment  
(
Unit
:
mm
)  
ORDERING INFORMATION (PART NO. : Ordering part number for Japanese market)  
AJW  
1
Protective construction  
2
:
Sealed  
5
:
Flux resistant  
Rated coil voltage (DC)  
Part No.  
Rated coil voltage (V)  
Contact material  
F
:
AgSnO type
 
(1a)  
2
0
6
1
2
3
5
9
9
5
Nil
:
AgNi type (1c, 2a, 2c)  
12 24 48  
Rated operating power  
Coil insulation class  
Nil
:
Class E insulation  
81
:
Class B insulation (UL )  
1
:
Standard  
Contact arrangement/Contact capacity  
1
:
1 Form A Standard (5A)  
2
:
1 Form A High capacity (10A)*  
3
:
1 Form C Standard (5A)  
4
:
1 Form C High capacity (10A)*  
5
:
2 Form A Standard (5A)  
7
:
2 Form C Standard (5A)  
* 1Form A and 1 Form C only.  
ORDERING INFORMATION (TYPE NO. : Ordering part number for non Japanese market)  
JW  
N
Contact capacity  
Nil
:
Standar
d
(
5A
)  
F
:
High capacit
y
(
10A
)
*  
Operate voltage  
N
:
Max. 70% V of rated coil voltage  
Rated coil voltage  
DC 5, 6, 9, 12, 24, 48V  
Contact arrangement  
Protective construction  
S
:
Sealed  
H
:
Flux-resistant  
Coil insulation class  
Nil
:
Class E insulation  
B
:
Class B insulation  
Contact material  
F
:
AgSnO typ
e
(
1a
)  
Nil
:
AgNi typ
e
(
1c, 2a, 2c
)  
1
:
1 Form C  
1a
:
1 Form A  
2
:
2 Form C  
2a
:
2 Form A  
2
* 1Form A and 1 Form C only.  
Panasonic Industry Co., Ltd. Electromechanical Control Business Division  
Panasonic Industry Co., Ltd. 2022  
ASCTB190E 202
204  
ー 1 ー  
industrial.panasonic.com/ac/e/  

Power relay (Over 2 A) JW RELAYS  
TYPES  
” Type No. ” is ordering part number for non Japanese market. ” Part No. ” is ordering part number for Japanese market.  
Standard type (5 A)  
Sealed  
Flux-resistant  
Standard packing  
Contact  
arrangement  
Rated coil  
voltage  
Type No.  
Part No.  
Type No.  
Part No.  
Inner carton
 
Outer carton  
5
6
9
V DC  
V DC  
V DC  
JW  
JW  
JW  
JW  
JW  
JW  
JW  
JW  
JW  
JW  
JW  
JW  
JW  
JW  
JW  
JW  
JW  
JW  
JW  
JW  
JW  
JW  
JW  
JW  
1
1
1
1
1
1
1
1
1
1
1
1
2
2
2
2
2
2
2
2
2
2
2
2
aSN-DC  
aSN-DC  
aSN-DC  
5
6
9
V-F  
V-F  
V-F  
AJW
1219  
AJW
1210  
AJW
1215  
F
JW  
JW  
JW  
JW  
JW  
JW  
JW  
JW  
JW  
JW  
JW  
JW  
JW  
JW  
JW  
JW  
JW  
JW  
JW  
JW  
JW  
JW  
JW  
JW  
1
1
1
1
1
1
1
1
1
1
1
1
2
2
2
2
2
2
2
2
2
2
2
2
aHN-DC  
aHN-DC  
aHN-DC  
5
6
9
V-F  
V-F  
V-F  
AJW
1519  
AJW
1510  
AJW
1515  
F
F
F
F
F
1
1
2
2
Form A  
Form C  
Form A  
Form C  
12
V DC  
24
V DC  
48
V DC  
aSN-DC
12
V-F  
aSN-DC
24
V-F  
aSN-DC
48
V-F  
AJW
1211  
F
aHN-DC
12
V-F  
aHN-DC
24
V-F  
aHN-DC
48
V-F  
AJW
1511
F  
AJW
1212  
AJW
1213  
AJW
3219  
AJW
3210  
AJW
3215  
AJW
3211  
AJW
3212  
AJW
3213  
AJW
5219  
AJW
5210  
AJW
5215  
AJW
5211  
AJW
5212  
AJW
5213  
AJW
7219  
AJW
7210  
AJW
7215  
AJW
7211  
AJW
7212  
AJW
7213  
F
F
AJW
1512  
AJW
1513  
AJW
3519  
AJW
3510  
AJW
3515  
AJW
3511  
AJW
3512  
AJW
3513  
AJW
5519  
AJW
5510  
AJW
5515  
AJW
5511  
AJW
5512  
AJW
5513  
AJW
7519  
AJW
7510  
AJW
7515  
AJW
7511  
AJW
7512  
AJW
7513  
F
F
5
6
9
V DC  
V DC  
V DC  
SN-DC  
SN-DC  
SN-DC  
5
V  
6
V  
9
V  
HN-DC  
HN-DC  
HN-DC  
5
6
9
V
V
V
12
V DC  
24
V DC  
48
V DC  
SN-DC
12  
SN-DC
24  
SN-DC
48  
V
V
V
HN-DC
12  
HN-DC
24  
HN-DC
48  
V
V
V
100
pcs.  
500
pcs.  
5
6
9
V DC  
V DC  
V DC  
aSN-DC  
aSN-DC  
aSN-DC  
5
V
V
V
aHN-DC  
aHN-DC  
aHN-DC  
5
V
V
V
6
9
6
9
12
V DC  
24
V DC  
48
V DC  
aSN-DC
12  
aSN-DC
24  
aSN-DC
48  
V
V
V
aHN-DC
12  
aHN-DC
24  
aHN-DC
48  
V
V
V
5
6
9
V DC  
V DC  
V DC  
SN-DC  
SN-DC  
SN-DC  
5
V  
6
V  
9
V  
HN-DC  
HN-DC  
HN-DC  
5
6
9
V
V
V
12
V DC  
24
V DC  
48
V DC  
SN-DC
12  
SN-DC
24  
SN-DC
48  
V
HN-DC
12  
HN-DC
24  
HN-DC
48  
V
V
V
V
V
Note: Class B coil insulation type is available. Ex) AJW121181F  
High capacity type (10 A)  
Sealed  
Flux-resistant  
Standard packing  
Inner carton
 
Outer carton  
Contact  
arrangement  
Rated coil  
voltage  
Type No.  
Part No.  
Type No.  
Part No.  
5
6
9
V DC  
V DC  
V DC  
JW  
JW  
JW  
JW  
JW  
JW  
JW  
JW  
JW  
JW  
JW  
JW  
1
1
1
1
1
1
1
1
1
1
1
1
aFSN-DC  
aFSN-DC  
aFSN-DC  
5
V-F  
AJW
2219  
AJW
2210  
AJW
2215  
F
JW  
JW  
JW  
JW  
JW  
JW  
JW  
JW  
JW  
JW  
JW  
JW  
1
1
1
1
1
1
1
1
1
1
1
1
aFHN-DC  
aFHN-DC  
aFHN-DC  
5
V-F  
V-F  
V-F  
AJW
2519  
AJW
2510  
AJW
2515  
F
6
9
V-F  
V-F  
F
F
6
9
F
F
1
Form A  
12
V DC  
24
V DC  
48
V DC  
aFSN-DC
12
V-F  
aFSN-DC
24
V-F  
aFSN-DC
48
V-F  
AJW
2211  
F
aFHN-DC
12
V-F  
aFHN-DC
24
V-F  
aFHN-DC
48
V-F  
AJW
2511
F  
AJW
2212  
AJW
2213  
AJW
4219  
AJW
4210  
AJW
4215  
AJW
4211  
AJW
4212  
AJW
4213  
F
F
AJW
2512  
AJW
2513  
AJW
4519  
AJW
4510  
AJW
4515  
AJW
4511  
AJW
4512  
AJW
4513  
F
F
100
pcs.  
500
pcs.  
5
6
9
V DC  
V DC  
V DC  
FSN-DC  
FSN-DC  
FSN-DC  
5
6
9
V
V
V
FHN-DC  
FHN-DC  
FHN-DC  
5
6
9
V
V
V
1
Form C  
12
V DC  
24
V DC  
48
V DC  
FSN-DC
12  
FSN-DC
24  
FSN-DC
48  
V
V
V
FHN-DC
12  
FHN-DC
24  
FHN-DC
48  
V
V
V
Note: Class B coil insulation type is available. Ex) AJW121181F  
For the sockets, please refer to the “JW RELAYS PC board sockets”.  
Panasonic Industry Co., Ltd. Electromechanical Control Business Division  
Panasonic Industry Co., Ltd. 2022  
ASCTB190E 202
204  
ー 2 ー  
industrial.panasonic.com/ac/e/  

Power relay (Over 2 A) JW RELAYS  
RATING  
Coil data  
• Operating characteristics such as ‘Operate voltage’ and ‘Release voltage’ are influenced by mounting conditions, ambient  
temperature, etc.  
Therefore, please use the relay within ±5% of rated coil voltage.  
• ‘Initial’ means the condition of products at the time of delivery.  
Rated operating  
current  
(±
10
%, at
20
°C)  
Rated coil  
voltage  
Operate voltage*

1

Release voltage*

1  

Coil resistance  
(±
10
%, at
20
°C)  
Rated operating  
power  
Max. allowable voltage  
(at
20
°C)  
(at
20
°C)  
5
6
9
V DC  
V DC  
V DC  
106
mA  
88
mA  
58
mA  
44
mA  
22
mA  
11
mA  
47  
68  
Ω
Ω
Ω
Ω
Ω
Ω
130
% V of rated coil  
voltage  
Max.
70
% V of  
rated coil voltage  
(Initial)  
Min.
10
% V of  
rated coil voltage  
(Initial)  
155  
270  
100  
400  
(at
60
°C: class E)  
120
% V of rated coil  
voltage  
530
mW  
12
V DC  
24
V DC  
1
4
,
,
(at
85
°C: class B)*

2  

48
V DC  
*1. square, pulse drive  
*2. The operate and release voltages rise approximately 0.4% for every 1°C given a standard ambient temperature of 20°C.  
Therefore, when using relays where the ambient temperature is high, please take into consideration the rise in operate voltage and keep the coil applied voltage within the  
maximum allowable applied voltage.  
Specifications  
Specifications  
Item  
Standard type  
Form A,
 
Form C  
High capacity type  
1
Form A,
1
Form C  
Contact arrangement  
1
Form A,  
1
Form C,  
2
2
Contact resistance  
(initial)  
Max.
100
mΩ (by voltage drop  
6
V DC  
Form C,
 
Form A,  
30
V DC  
1
A)  
Contact material  
1
5
Form A: AgSnO  
250
V AC,  
250
VA,
150  
2
type,  
1
2
2
Form C: AgNi type  
10 250
 
V AC,
10  
500
VA,
300  
Contact rating  
(resistive)  
A
5
A
A
A
30
V DC  
Contact data  
Max. switching power  
(resistive)  
1
,
W
2
,  
W
Max. switching voltage
 
250
V AC,
30
V DC  
Max. switching current  
5
A
10
A  
Min. switching load  
(reference value)*

1  

100
mA  
Min.
000
MΩ (at
500
V DC, Measured portion is the same as the case of dielectric strength.)  
000
Vrms for
 
min (detection current:
10
mA)  
Form A,
 
Form C:
 
000
Vrms for
 
min (detection  
5
V DC  
Insulation resistance (initial)  
1
,  
Between open contacts  
1
2
,
1
Dielectric  
strength  
(initial)  
2
3
,  
1
Between contact sets  
−
current:
10
mA)  
Between contact and  
coil  
5
,
000
Vrms for
1
min (detection current:
10
mA)  
Surge  
withstand  
voltage  
(initial)*

2  

Between contact and  
coil  
10
,
000
V  
Time  
characteristics  
(initial)  
Operate time  
Release time  
Max.
15
ms (at rated coil voltage, at
20
°C, without bounce)  
Max. ms
 
(at rated coil voltage, at
20
°C, without bounce, without diode)  
98
m/s

2

(half-sine shock pulse:
11
ms, detection time:
10
μs)  
980
m/s

2

(half-sine shock pulse:  
ms)  
5
Functional  
Shock  
resistance  
Destructive  
6
Functional  
10
to
55
Hz (at double amplitude of  
10
to
55
Hz (at double amplitude of  
1
2
.
6
mm, detection time:
10
μs)  
Vibration  
resistance  
Destructive  
mm)  
Expected life  
Conditions  
Unit weight  
Mechanical life  
Conditions for usage,  
Min.  
Ambient temperature: –
40
to +
60
°C (class E), –
40
to +
85
°C (class B)*

4  

to
85
% RH (Avoid icing and condensation)  
5
x  
10

6

(switching frequency:
180
times/min)  
transport and storage*

3

Humidity:  
5
Approx.
13  
g
*1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load.  
*2. Wave is standard shock voltage of ±1.2×50 μs according to JEC-212-1981  
*3. For ambient temperature, please read “GUIDELINES FOR RELAY USAGE”.  
*4. The operate and release voltages rise approximately 0.4% for every 1°C given a standard ambient temperature of 20°C.  
Therefore, when using relays where the ambient temperature is high, please take into consideration the rise in operate voltage and keep the coil applied voltage within the  
maximum allowable applied voltage.  
Panasonic Industry Co., Ltd. Electromechanical Control Business Division  
Panasonic Industry Co., Ltd. 2022  
ASCTB190E 202
204  
ー 3 ー  
industrial.panasonic.com/ac/e/  

Power relay (Over 2 A) JW RELAYS  
Expected electrical life  
Conditions: Resistive load, at 20°C, Flux-resistant: 20 times/min • Sealed: 6 times/min  
Type  
Switching capacity  
Number of operations  
5
A
250
V AC  
30
V DC  
A
250
V AC  
Min.
100  
Min.
100  
Min.
100  
Min.
100  
×
×
×
×
10

3  

10

3  

10

3  

10

3  

1
Form A,  
1
1
Form C,
 
Form A,
2
Form C  
(Standard)  
2
5
A
10  
10  
Form A,  
1
Form C  
(High capacity)  
A
30
V DC  
REFERENCE DATA  
1 Form A Standard type  
1.Max. switching capacity  
2.Switching life curve  
3.Operate and release time characteristics  
Tested
s
ample
:
JW1aSN-DC 12V-F, 10 pcs.  
Ambient temperature
:
20
℃  
100  
10  
10  
100  
Operate time  
250V AC resistive load  
30V DC resistive load  
Max.  
5
0
AC resistive  
load  
Ave.  
Min  
DC resistive  
load  
10  
1
Release time  
Max.  
Ave.  
Min  
1
10  
100  
1,000  
5
10  
15  
80  
90  
100  
110  
120  
Contact voltag
e
(
V
)  
Contact curre
n
(
t A
)  
Coil applied voltag
e
(
%V
)  
1 Form A High capacity type  
1.Max. switching capacity  
2.Switching life curve  
100  
10  
100  
250V AC resistive load  
30V DC resistive load  
DC resistive  
load  
AC resistive  
load  
10  
1
1
1
10  
100  
1,000  
0
2
4
6
8
10  
12  
Contact voltag
e
(
V
)  
Contact curre
n
(
t A
)  
3-1.Coil temperature characteristics  
(Average)  
3-2.Coil temperature characteristics  
(Average)  
4.Operate and release time characteristics  
Tested sample
:
JW1aFSN-DC 12V-F  
Measured portion
:
Coil inside  
Contact carrying current
:
5A  
Tested sample
:
JW1aFSN-DC 12V-F  
Measured portion
:
Coil inside  
Contact carrying current
:
10A  
Tested sample
:
JW1aFSN-DC 12V-F, 10 pcs.  
Ambient temperature
:
20
℃  
70  
60  
50  
40  
30  
20  
70  
60  
50  
40  
30  
20  
10  
25
℃  
60
℃  
85
℃  
25
℃  
60
℃  
85
℃  
Operate time  
Max.  
Ave.  
Min  
5
0
Max.  
Ave.  
Min  
Release time  
10  
0
10  
0
100  
120  
140  
160  
100  
120  
140  
160  
80  
90  
100  
110  
120  
Coil applied voltag
e
(
%V
)  
Coil applied voltag
e
(
%V
)  
Coil applied voltag
e
(
%V
)  
Panasonic Industry Co., Ltd. Electromechanical Control Business Division  
Panasonic Industry Co., Ltd. 2022  
ASCTB190E 202
204  
ー 4 ー  
industrial.panasonic.com/ac/e/  

Power relay (Over 2 A) JW RELAYS  
1 Form C Standard type  
1.Max. switching capacity  
2.Operate and release time characteristics  
Tested sample
:
JW1SN-DC 12V, 6 pcs.  
Ambient temperature
:
20
℃  
100  
13  
12  
11  
10  
9
10  
AC resistive loa
d
(
co
s
φ
≒
1.0
)  
8
Operate time  
7
6
Max.  
1
0
5
4
3
2
1
Ave.  
Min.  
Release time  
Max.  
Ave.  
Min.  
1
10  
100  
1,000  
80  
90  
100  
110  
120  
130  
Contact voltag
e
(
V
)  
Coil applied voltag
e
(
%V
)  
1 Form C High capacity type  
1.Max. switching capacity  
100  
AC resistive loa
d
(
co
s
φ
≒
1.0
)  
10  
1
0
1
10  
100  
1,000  
Contact voltag
e
(
V
)  
2 Form A Standard type  
1.Max. switching capacity  
2.Operate and release time characteristics  
Tested sample
:
JW2aSN-DC 24V, 6 pcs.  
Ambient temperature
:
20
℃  
100  
14  
13  
12  
10  
Operate time  
10  
AC resistive loa
d
(
co
s
φ
≒
1.0
)  
Max.  
8
6
4
2
Ave.  
Min.  
1
0
Release time  
100  
Max.  
Ave.  
Min.  
1
10  
100  
1,000  
80  
90  
110  
120  
Contact voltag
e
(
V
)  
Coil applied voltag
e
(
%V
)  
Panasonic Industry Co., Ltd. Electromechanical Control Business Division  
Panasonic Industry Co., Ltd. 2022  
ASCTB190E 202
204  
ー 5 ー  
industrial.panasonic.com/ac/e/  

Power relay (Over 2 A) JW RELAYS  
2 Form C Standard type  
1.Max. switching capacity  
2.Operate and release time characteristics  
Tested sample
:
JW2SN-DC 24V, 6 pcs.  
Ambient temperature
:
20
℃  
100  
9
8
7
Operate time  
10  
6
AC resistive loa
d
(
co
s
φ
≒
1.0
)  
Max.  
Ave.  
5
4
3
2
1
0
Min.  
1
0
Max.  
Ave.  
Min.  
Release time  
1
10  
100  
1,000  
80  
90  
100  
110  
120  
130  
Contact voltag
e
(
V
)  
Coil applied voltag
e
(
%V
)  
CAD  
The CAD data of the products with a “CAD” mark can be downloaded from our Website.  
DIMENSIONS  
Unit: mm  
1 Form A  
CAD  
External dimensions  
Recommended PC board pattern  
(BOTTOM VIEW)  
Relay  
outline  
3.5  
20  
2.4  
4
ー
1.5dia.  
Tolerance
±
0.1  
Schematic  
(BOTTOM VIEW)  
0.5  
0.3  
0.3  
28.6  
20  
3.5  
2.4  
General tolerance  
Less than 1mm
:±
0.1  
Min. 1mm less than 3mm
:±
0.2  
Min. 3mm
:±
0.3  
Panasonic Industry Co., Ltd. Electromechanical Control Business Division  
Panasonic Industry Co., Ltd. 2022  
ASCTB190E 202
204  
ー 6 ー  
industrial.panasonic.com/ac/e/  

Power relay (Over 2 A) JW RELAYS  
1 Form C  
CAD  
External dimensions  
Recommended PC board pattern  
(BOTTOM VIEW)  
Relay  
outline  
16.5  
3.
5
3
.5  
2.4  
5
ー
1.5dia.  
Tolerance
±
0.1  
Schematic  
(BOTTOM VIEW)  
0.5  
0.5  
0.3  
0.3  
28.6  
16.5  
3.5 3.5  
2.4  
General tolerance  
Less than 1mm
:±
0.1  
Min. 1mm less than 3mm
:±
0.2  
Min. 3mm
:±
0.3  
2 Form A, 2 Form C  
CAD  
External dimensions  
Recommended PC board pattern  
(BOTTOM VIEW)  
Relay  
outline  
15  
5
5
1.3  
8
ー
1.5dia.  
Tolerance
±
0.1  
Schematic  
(BOTTOM VIEW)  
0.5  
0.5  
0.3  
0.3  
28.6  
15  
5
5
1.3  
General tolerance  
Less than 1mm
:±
0.1  
Min. 1mm less than 3mm
:±
0.2  
Min. 3mm
:±
0.3  
Not
e
:
JW 2 Form A is as shown in the diagram above except the N.C. terminals are not present.  
Panasonic Industry Co., Ltd. Electromechanical Control Business Division  
Panasonic Industry Co., Ltd. 2022  
ASCTB190E 202
204  
ー 7 ー  
industrial.panasonic.com/ac/e/  

Power relay (Over 2 A) JW RELAYS  
Each standard may be updated at any time, so please check our Website for the latest information.  
SAFETY STANDARDS  
UL (Recognized)  
Standard type  
1 Form A  
2 Form A  
File No.  
Contact rating  
File No.  
Contact rating  
5
A
A
277
V AC  
30
V DC  
5
A
A
277
V AC  
30
V DC  
5
5
E43028  
E43028  
1
1
⁄
8
HP
250
V AC  
HP
125
V AC  
⁄
8
HP
250
V AC  
HP
125
V AC  
1
1
⁄
8
⁄
8
1 Form C  
2 Form C  
File No.  
Contact rating  
File No.  
Contact rating  
5
A
277
V AC  
30
V DC  
5
A
277
V AC  
5
A
5
A
30
V DC  
E43028  
E43028  
1
1
⁄
8
HP
250
V AC  
HP
125
V AC  
⁄
8
HP
250
V AC  
HP
125
V AC  
1
1
⁄
8
⁄
8
High capacity type  
1 Form A  
1 Form C  
File No.  
Contact rating  
File No.  
Contact rating  
10  
A
A
277
V AC  
30
V DC  
10  
A
A
277
V AC  
30
V DC  
10  
10  
E43028  
E43028  
1
1
⁄
3
HP
250
V AC  
HP
125
V AC  
⁄
3
HP
250
V AC  
HP
125
V AC  
1
1
⁄
3
⁄
3
CSA (Certified)  
Standard type  
1 Form A  
2 Form A  
File No.  
Contact rating  
File No.  
Contact rating  
5
A
277
V AC  
30
V DC  
5
A
277
V AC  
5
A
5
A
30
V DC  
LR26550  
LR26550  
1
1
⁄
⁄
8
HP
250
V AC  
HP
125
V AC  
⁄
8
HP
250
V AC  
HP
125
V AC  
1
1
8
⁄
8
1 Form C  
File No.  
2 Form C  
Contact rating  
File No.  
Contact rating  
5
A
277
V AC  
5
A
277
V AC  
5
A
30
V DC  
5
A
30
V DC  
LR26550  
LR26550  
1
1
⁄
⁄
8
HP
250
V AC  
HP
125
V AC  
⁄
8
HP
250
V AC  
HP
125
V AC  
1
1
8
⁄
8
High capacity type  
1 Form A  
1 Form C  
File No.  
Contact rating  
File No.  
Contact rating  
10  
A
A
277
V AC  
30
V DC  
10  
A
A
277
V AC  
30
V DC  
10  
10  
LR26550  
LR26550  
1
1
⁄
⁄
3
HP
250
V AC  
HP
125
V AC  
⁄
3
HP
250
V AC  
HP
125
V AC  
1
1
3
⁄
3
Panasonic Industry Co., Ltd. Electromechanical Control Business Division  
Panasonic Industry Co., Ltd. 2022  
ASCTB190E 202
204  
ー 8 ー  
industrial.panasonic.com/ac/e/  

Power relay (Over 2 A) JW RELAYS  
VDE (Certified)  
Standard type  
1 Form A  
2 Form A  
File No.  
Contact rating  
File No.  
Contact rating  
5
3
A
A
250
V AC (cosφ =  
250
V AC (cosφ =  
1
0
.
0
4
)
)
5
5
3
A
A
A
250
V AC (cosφ =  
30
V DC (
 
ms)  
250
V AC (cosφ =  
1
0
.
0
4
)
)
40013854  
40013854  
0
.
.
1 Form C  
File No.  
2 Form C  
Contact rating  
File No.  
Contact rating  
5
5
3
A
A
A
250
V AC (cosφ =  
30
V DC (
 
ms)  
250
V AC (cosφ =  
1
0
.
0
4
)
)
5
5
3
A
A
A
250
V AC (cosφ =  
30
V DC (
 
ms)  
250
V AC (cosφ =  
1
0
.
0
4
)
)
40013854  
0
40013854  
0
.
.
High capacity type  
1 Form A  
1 Form C  
File No.  
Contact rating  
File No.  
Contact rating  
10  
A
250
V AC (cosφ =  
1
.
0
)
10  
10  
A
A
250
V AC (cosφ =  
30
V DC (
 
ms)  
1
.
0
)  
40013854  
40013854  
0
7
A
250
V AC (cosφ =
0
.
4  
)
7
A
250
V AC (cosφ =
0
.
4  
)
CQC (Certified)  
2 Form C (AJW7211 only)  
File No.  
Contact rating  
CQC10002041727  
5
A
250
V AC  
INSULATION CHARACTERISTICS (IEC61810-1)  
Item  
Characteristics  
Clearance/Creepage distance (IEC61810-  
1
)
Min.
5
.
5
/
8
.
0
mm  
Category of protection (IEC61810-  
Tracking resistance (IEC60112)  
Insulation material group  
Over voltage category  
Rated voltage  
1
)
RT II, III  
PTI
175  
III a  
III  
250  
3
V
Pollution degree  
Type of insulation (Between contact and coil)  
Type of insulation (Between open contacts)  
Note: EN/IEC VDE Certified.  
Reinforced insulation  
Micro disconnection  
GUIDELINES FOR USAGE  
For cautions for use, please read “GUIDELINES FOR REL
A
Y
U
SAGE”.  
Panasonic Industry Co., Ltd. Electromechanical Control Business Division  
Panasonic Industry Co., Ltd. 2022  
ASCTB190E 202
204  
ー 9 ー  
industrial.panasonic.com/ac/e/  

Power relay (Over 2 A) JW RELAYS  
JW REL
A
Y
S PC board sockets  
SELECTOR CHART  
Socket  
JW  
1
PC board socket  
JW
2  
PC board socket  
Relay type  
1
1
2
2
Form A  
Form C  
Form A  
Form C  
−
−
●
●
−
●
●
−
TYPES  
Standard packing  
Product name  
Type No.  
Part No.  
Inner carton  
10
pcs.  
Outer carton  
100
pcs.  
JW  
1
PC board socket  
PC board socket  
JW
1
-PS  
-PS  
AJW
8015  
AJW
8025  
JW  
2
JW
2  
RATING  
Item  
Specifications  
Contact arrangement  
1
pole  
Between charging portion:  
Between charging portion: Min.
100
MΩ  
(at
500
V DC, Measured portion is the same as the case of dielectric strength.)  
10  
Ambient temperature: –
50
to +
50
°C  
Humidity: to
 
85
% RH (Avoid icing and condensation)  
2
poles  
Dielectric strength (initial)  
1
,
500
Vrms for
1
min (detection current:
10
mA)  
Insulation resistance (initial)  
Maximum carrying current  
A
5
A  
Conditions for usage, transport and storage  
5
CAD  
The CAD data of the products with a “CAD” mark can be downloaded from our Website.  
DIMENSIONS  
CAD  
Unit: mm  
External dimensions  
Recommended PC board pattern  
(Copper side view)  
1 pole  
2 poles  
Socket outline  
5
ー
1.3dia.  
Socket outline  
8
ー
1.3dia.  
32
±
0.6  
(
4.4
)  
(
4
)  
3.5 3.5  
16.5  
15  
5
5
Tolerance
±
0.1  
Tolerance
±
0.1  
0.35
±
0.1  
Pre-soldering  
Panasonic Industry Co., Ltd. Electromechanical Control Business Division  
Panasonic Industry Co., Ltd. 2022  
ASCTB190E 202
204  
ー 10 ー  
industrial.panasonic.com/ac/e/  

Power relay (Over 2 A) JW RELAYS  
HANDLING  
Mounting method of relay  
Removing method of relay  
1) Match the direction of relay and socket.  
1) Remove the relay, applying force in the direction as shown in  
the figure.  
2) In case there is not enough  
space to grasp relay with  
fingers, use screwdrivers  
in the way as shown in the  
figure.  
2) Both ends of the relay are to be secured  
firmly so that the socket both hooks on  
the top surface of the relay.  
3) Exercise care when removing relays. If greater than necessary  
force is applied at the socket hooks, deformation may alter the  
dimensions so that the hook will no longer catch, and other  
damage may also occur.  
Panasonic Industry Co., Ltd. Electromechanical Control Business Division  
Panasonic Industry Co., Ltd. 2022  
ASCTB190E 202
204  
ー 11 ー  
industrial.panasonic.com/ac/e/  

GUIDELINES FOR POWER, HIGH-CAPACITY DC CUT OFF AND SAFETY RELAYS USAGE  
For cautions for use, please read “GUIDELINES FOR REL
A
Y
U
SAGE”.  
Precautions for Coil Input  
Long term current carrying  
Maximum allowable voltage and temperature rise  
Proper usage requires that the rated coil voltage be impressed on  
the coil. Note, however, that if a voltage greater than or equal to the  
maximum continuous voltage is impressed on the coil, the coil may  
burn or its layers short due to the temperature rise. Furthermore, do  
not exceed the usable ambient temperature range listed in the  
catalog.  
A circuit that will be carrying a current continuously for long periods  
without relay switching operation. (circuits for emergency lamps,  
alarm devices and error inspection that, for example, revert only  
during malfunction and output warnings with form B contacts)  
Continuous, long-term current to the coil will facilitate deterioration  
of coil insulation and characteristics due to heating of the coil itself.  
For circuits such as these, please use a magnetic-hold type latching  
relay. If you need to use a single stable relay, use a sealed type  
relay that is not easily affected by ambient conditions and make a  
failsafe circuit design that considers the possibility of contact failure  
or disconnection.  
Operate voltage change due to coil temperature rise  
In DC relays, after continuous passage of current in the coil, if the  
current is turned OF
F
,
t
hen immediately turned ON again, due to the  
temperature rise in the coil, the operate voltage will become  
somewhat higher. Also, it will be the same as using it in a higher  
temperature atmosphere. The resistance/temperature relationship  
for copper wire is about 0.4% for 1°C, and with this ratio the coil  
resistance increases. That is, in order to operate of the relay, it is  
necessary that the voltage be higher than the operate voltage and  
the operate voltage rises in accordance with the increase in the  
resistance value. However, for some polarized relays, this rate of  
change is considerably smaller.  
DC Coil operating power  
Steady state DC current should be applied to the coil. The wave  
form should be rectangular. If it includes ripple, the ripple factor  
should be less than 5%.  
However, please check with the actual circuit since the electrical  
characteristics may vary. The rated coil voltage should be applied to  
the coil and the set/reset pulse time of latching type relay differs for  
each relays, please refer to the relay’s individual specifications.  
Coil connection  
When connecting coils of polarized relays, please check coil polarity  
(+,-) at the internal connection diagram (Schematic). If any wrong  
connection is made, it may cause
 
unexpected malfunction, like  
abnormal heat, fire and so on, and circuit do not work. Avoid  
impressing voltages to the set coil and reset coil at the same time.  
Ambient Environment  
Dew condensation  
Usage, Transport, and Storage Conditions  
During usage, storage, or transportation, avoid locations subjected  
to direct sunlight and maintain normal temperature, humidity and  
pressure conditions.  
Condensation occurs when the ambient temperature drops suddenly  
from a high temperature and humidity, or the relay is suddenly  
transferred from a low ambient temperature to a high temperature  
and humidity. Condensation causes the failures like insulation  
deterioration, wire disconnection and rust etc.  
Temperature/Humidity/Pressure  
When transporting or storing relays while they are tube packaged,  
there are cases the temperature may differ from the allowable  
range. In this case be sure to check the individual specifications.  
Also allowable humidity level is influenced by temperature, please  
check charts shown below and use relays within mentioned  
conditions. (Allowable temperature values differ for each relays,  
please refer to the relay’s individual specifications.)  
Panasonic Industry Co., Ltd. does not guarantee the failures caused  
by condensation.  
The heat conduction by the equipment may accelerate the cooling  
of device itself, and the condensation may occur.  
Please conduct product evaluations in the worst condition of the  
actual usage. (Special attention should be paid when high  
temperature heating parts are close to the device. Also please  
consider the condensation may occur inside of the device.)  
Icing  
1)
T
e
mperature:  
The tolerance temperature range differs for each relays, please  
refer to the relay’s individual specifications  
2) Humidity: 5 to 85 % RH  
Condensation or other moisture may freeze on relays when the  
temperature become lower than 0°C.This icing causes the sticking  
of movable portion, the operation delay and the contact conduction  
failure etc. Panasonic Industry Co., Ltd. does not guarantee the  
failures caused by the icing.  
3) Pressure: 86 to 106 kPa  
Humidity (% RH)  
The heat conduction by the equipment may accelerate the cooling  
of relay itself and the icing may occur. Please conduct product  
evaluations in the worst condition of the actual usage.  
Low temperature and low humidity  
85  
The plastic becomes brittle if the switch is exposed to a low  
temperature, low humidity environment for long periods of time.  
High temperature and high humidity  
Allowable range  
Avoid icing  
Avoid con­  
when used at  
temperatures  
lower than 0
°
C  
densation when  
used at tem­  
peratures higher  
than 0
°
C  
Storage for extended periods of time (including transportation  
periods) at high temperature or high humidity levels or in  
atmospheres with organic gases or sulfide gases may cause a  
sulfide film or oxide film to form on the surfaces of the contacts and/  
or it may interfere with the functions. Check out the atmosphere in  
which the units are to be stored and transported.  
5
­40  
0
85  
Ambient temperature (℃)  
Panasonic Industry Co., Ltd. Electromechanical Control Business Division  
Panasonic Industry Co., Ltd. 2022  
ASCTB412E 202204  
ー 12 ー  
industrial.panasonic.com/ac/e/  

GUIDELINES FOR POWER, HIGH-CAPACITY DC CUT OFF AND SAFETY RELAYS USAGE  
Package  
NOx Generation  
In terms of the packing format used, make every effort to keep the  
effects of moisture, organic gases and sulfide gases to the absolute  
minimum.  
When relay is used in an atmosphere high in humidity to switch a  
load which easily produces an arc, the NOx created by the arc and  
the water absorbed from outside the relay combine to produce nitric  
acid.  
Silicon  
When a source of silicone substances (silicone rubber, silicone oil,  
silicone coating materials and silicone filling materials etc.) is used  
around the relay, the silicone gas (low molecular siloxane etc.) may  
be produced.  
This corrodes the internal metal parts and adversely affects  
operation.  
Avoid use at an ambient humidity of 85%RH or higher (at 20°C). If  
use at high humidity is unavoidable, please contact our sales  
representative.  
This silicone gas may penetrate into the inside of the relay. When  
the relay is kept and used in this condition, silicone compound may  
adhere to the relay contacts which may cause the contact failure.  
Do not use any sources of silicone gas around the relay (Including  
plastic seal types).  
Others  
Cleaning  
• Although the environmentally sealed type relay (plastic sealed type,  
etc.) can be cleaned, avoid immersing the relay into cold liquid (such  
as cleaning solvent) immediately after soldering. Doing so may  
deteriorate the sealing performance.  
• Cleaning with the boiling method is recommended(The temperature  
of cleaning liquid should be 40°C or lower ).  
Avoid ultrasonic cleaning on relays. Use of ultrasonic cleaning may  
cause breaks in the coil or slight sticking of the contacts due to  
ultrasonic energy.  
Please refer to
“the latest product specifications”  
when designing your product.  
•Requests to customers:  
Panasonic Industry Co., Ltd. Electromechanical Control Business Division  
Panasonic Industry Co., Ltd. 2022  
ASCTB412E 202204  
ー 13 ー  
industrial.panasonic.com/ac/e/  

Electromechanical Control Business Division  
1006, Oaza Kadoma, Kadoma-shi, Osaka 571-8506, Japan  
industral.panasonic.com/ac/e/  
Specifications are subject to change without notice.  
2022.4  
©Panasonic Industry Co., Ltd. 2022  
ASCTB190E 202204