PANASONIC-LK1AF-12V

Part #PANASONIC-LK1AF-12V
Download 
PANASONIC-LK1AF-12V
Discontinued as of August 31, 2011  
VDE  
SLIM POWER RELAY  
WITH HIGH INRUSH  
CURRENT CAPABILITY  
LK RELAYS  
2. High insulation resistance between  
contact and coil  
Creepage distance and clear-  
ances in compliance with IEC65  
11.0  
.433  
24.0  
1) Creepage distance and clearances  
between contact and coil: Min. 6 mm
.236  
inch
(In compliance with IEC65)  
2) Surge withstand voltage between  
contact and coil: 10,000 V or more  
.945  
25.0  
.984  
Card  
3. High noise immunity realized by the  
card separation structure between  
contact and coil  
Partition wall  
mm
inch  
4. Popular terminal pitch in AV  
equipment field  
5. Space-saving slim type  
Base area: Width 11
Length 24 mm  
Width .433
Length .945 inch  
6. Conforms to the various safety  
standards  
UL, CSA, VDE, TÜV, SEMKO, SEV, BSI  
approved  
Product is discontinued.  
mm
inch  
16.5  
.650  
1
.039  
FEATURES  
COM  
7.5  
.295  
1. High inrush current capability  
1) Operating load capability:  
inrush 100 A, steady 5 A  
2) UL/CSA, TV-5  
Coil  
N.O.  
20  
.787  
1
.039  
SPECIFICATIONS  
Contact  
Characteristics  
Arrangement  
1 Form A  
Max. operating speed  
20 cpm  
Initial insulation resistance*

1  

Min. 1,000 M
(at 500 V DC)  
Initial contact resistance, max.  
(By voltage drop 6 V DC 1 A)  
Max. 100 m
  
Between open contacts  
1,000 Vrms for 1 min  
Initial  
Contact material  
AgSnO
2
type  
breakdown  
voltage*

2  

Between contacts and  
coil  
4,000 Vrms for 1 min  
Nominal switching capacity
 
5 A 277 V AC, 5 A 30 V DC  
Max. switching power  
(resistive Max.
 
switching voltage  
1,385 VA, 150 W  
277 V AC, 30 V DC  
5A (AC), 5 A (DC)  
100 mA, 5 V DC  
2
10

6  

Rating  
Initial surge voltage between contact  
and coil*

3  

Operate time*

4

(at nominal voltage)  
Release time (without diode)*

4  

(at nominal voltage)  
Min. 10,000 V  
load)  
Max. switching current  
Min. switching capacity

#1  

Mechanical (at 180 cpm)  
Max. 15 ms (at 20
C
68
F
)  
Max. 5 ms (at 20
C
68
F
)  
Expected  
life (min.  
ope.)  
Electrical (at 20 cpm)  
(at rated load)  
10

5  

Max. 35
C with nominal coil  
voltage at 5A contact carrying  
current (resistance method)  
Temperature rise (at 70
C)  
Coil  
Functional*

5  

Shock  
Min. 200 m/s

2  

Min. 1,000 m/s

2  

Nominal operating power  
530 mW  
Destructive*

6  

resistance  
#1 This value can change due to the switching frequency, environmental conditions,  
and desired reliability level, therefore it is recommended to check this with the  
actual load.  
10 to 55 Hz  
at double amplitude of 1.5 mm  
Functional*

7  

Vibration  
Remarks  
resistance  
10 to 55 Hz  
at double amplitude of 1.5 mm  
Destructive  
* Specifications
 
will vary with foreign standards certification ratings.  
*

1

Measurement at same location as “Initial breakdown voltage” section.  
*

2

Detection current: 10mA  
Conditions for operation,  
transport and storage*

8  

(Not freezing and condens-  
ing at low temperature)  
Ambient temp.
 
–40 to +70
C
–40 to +158
F  
*

3

Wave is standard shock voltage of
1.2
50
s according to JEC-212-1981  
*

4

Excluding contact bounce time.  
Humidity  
5 to 85%R.H.  
*

5

Half-wave pulse of sine wave: 11 ms; detection time: 10
s  
*

6

Half-wave pulse of sine wave: 6 ms  
Air pressure  
86 to 106 kPa  
*

7

Detection time: 10
s  
Unit weight  
Approx. 12 g .
42 oz  
*

8

Refer to “6. Usage, Storage and Transport Conditions“ in

TYPICAL APPLICATIONS
 
ORDERING INFORMATION  
• AV equipment: TV’s, VTR’s, etc.  
• OA equipment  
Ex.  
LK  
1a  
F
24V  
• HA equipment  
Contact arrangement  
1a: 1 Form A  
Protective construction  
F: Flux-resistant type  
Coil voltage (DC)  
5, 6, 9, 12, 18, 24 V  
UL/CSA, TÜ
V
,
S
EMKO, TV-5 approved type is standard.  
(Note) Standard packing
 
Carton: 100 pcs. Case: 500 pcs.  
ds_61B13_en_lk: 010611J  
1

LK  
Discontinued as of August 31, 2011  
TYPES AND COIL DATA (at 20
C
68
F
)  
Nominal  
voltage,  
V DC  
Pick-up voltage
 
Drop-ou
t
v
oltage  
Nominal operating  
current,  
Nominal  
operatin
g
p
ower,  
mW  
Max. allowable  
voltage,  
V DC (at 20°C
68°F
)  
Coil resistance,  
Part No.  
V DC (max.)  
(Initial)  
V DC (min.)  
(Initial)  
(
10%)  
mA (
10%)  
LK1aF-5V  
LK1aF-6V  
LK1aF-9V  
LK1aF-12V  
LK1aF-18V  
LK1aF-24V  
5
6
3.5  
4.2  
0.5  
0.6  
0.9  
1.2  
1.8  
2.4  
47  
68  
106.4  
88.3  
58.8  
44.2  
29.5  
22.1  
530  
530  
530  
530  
530  
530  
6.5  
7.8  
9
6.3  
153  
11.7  
15.6  
23.4  
31.2  
12  
18  
24  
8.4  
272  
12.6  
16.8  
611  
1,087  
DIMENSIONS
(mm
inch
)  

Download

from our Web site.  
PC board pattern (Bottom view)  
2-0.9 dia  
2-.035 dia  
2-1.3 dia  
2-.051 dia  
16.5  
.650  
Max. 25  
.984  
7.5  
.295  
0.5  
.020  
20.0  
.787  
4
.157  
0.5 dia.
 
0.3  
.020 dia.
 
.012  
Tolerance:
0.1
.004  
1.65  
.065  
0.4  
.016  
Schematic (Bottom view)  
Max. 24  
.945  
Max. 11  
.433  
16.5  
.650  
1
.039  
Dimension :  
Max. 1mm
.039 inch
:  
General tolerance  
0.1
.004  
7.5  
.295  
1 to 3mm
.039 to .118 inch
:
0.2
.008  
Min. 3mm
.118 inch
:
0.3
.012  
20  
.787  
1
.039  
REFERENCE DATA  
1. Max. switching power (AC resistive load)  
2. Coil temperature rise  
3. Ambient temperature characteristics  
Contact current: 5 A  
Sample: LK1aF-12V, 6 pcs.  
Point measured: coil inside  
Contact current: 5 A  
10  
200  
Allowable ambient temperatures  
against % coil voltages  
180  
50  
(max. inside the coil tem-  
perature set as  
115
°
C
239
°
F
)  
Ambient temperature  
30
°
C  
160  
140  
120  
100  
80  
40  
30  
20  
10  
0
1
Ambient temperature  
70
°
C  
Cold start  
Pick-up voltage  
0.1  
60  
90  
100 110  
120  
Coil applied voltage, %V  
80  
0.1  
1
10  
100  
1000  
10  
20  
30  
40  
50  
60  
70  
80  
Contact voltage, V  
Ambient temperature,
°
C  
ds_61B13_en_lk: 010611J  
2

LK  
Discontinued as of August 31, 2011  
4. Life curve  
Operation frequency: 20 times/min.  
(ON/OFF = 1.5s: 1.5s)  
5-1. Operate & release time (without diode)  
Sample: LK1aF-12V, 20 pcs.  
5-2. Operate & release time (with diode)  
Sample: LK1aF-12V, 20 pcs.  
Ambient temperature: room temperature  
100  
15  
15  
Operate time  
Operate time  
Release time  
Release time  
250V AC resistive load  
10  
10  
Max.  
Min.  
10  
Max.  
Min.  
Max.  
Min.  
5
5
Max.  
Min.  
1
0
0
0
1
2
3
4
5
70  
100  
130  
70  
100  
130  
Coil applied voltage, %V  
Contact current, A  
Coil applied voltage, %V  
6-1. Electrical life test  
Change of pick-up and drop-out voltage  
Change of contact resistance  
(5 A 277 V AC, resistive load)  
100  
50  
Sample: LK1aF-12V, 6 pcs.  
Operation frequency: 20 times/min.  
(ON/OFF = 1.5s: 1.5s)  
80  
60  
40  
30  
20  
10  
0
Ambient temperature: 26
C
79
F  
Circuit:  
Max.  
Min.  
Pick-up voltage  
40  
Contact  
welding  
detection  
and Mis-  
contacting  
detection  
circuit  
AC277V  
DC12V  
Max.  
Min.  
20  
Max.  
Min.  
Drop-out voltage  
0
0
5
10  
0
5
10  
No. of operations,
×
10

4  

No. of operations,
×
10

4  

6-2. Electrical life test  
Change of pick-up and drop-out voltage  
Change of contact resistance  
(UL lamp load test TV-5)  
Tested sample: LK1aF-12V, 6 pcs.  
• Overload test  
50  
100  
Load: 7.5 A 120 V AC (60 Hz),  
Inrush: 111 A  
Operation frequency: 10 times/min  
(ON: OFF = 1 s: 5 s)  
No. of operations: 50 ope.  
• Endurance test  
Load: 5A 120 V AC (60 Hz),  
Inrush: 78 A  
40  
30  
20  
10  
80  
60  
Max.  
Min.  
Pick-up voltage  
40  
Operation frequency: 10 times/min  
(ON: OFF = 1 s: 5 s)  
No. of operations: 25,000 ope.  
20  
Max.  
Min.  
Max.  
Min.  
Drop-out voltage  
0
0
0
2.5  
0
2.5  
No. of operations,
×
10

4  

No. of operations,
×
10

4  

NOTES  
1. Cleaning  
2. Soldering  
2) Hand soldering  
This relay is not the sealed type, so it  
cannot be immersion cleaned. Be careful  
that flux does not overflow onto the PC  
board or penetrate inside the relay.  
We recommend the following soldering  
conditions.  
1) Automatic soldering  
* Preheating: 100
C
212
F
, within 2 mins  
(PC board solder surface)  
* Iron tip temperature: 280 to 300
C
536  
to 571
F  
* Soldering iron: 30 to 60W  
* Soldering time: Within 3 s  
* Soldering: 260
C
500
F
, within 5 s  
For Cautions for Use, see
 

ds_61B13_en_lk: 010611J  
3