PANASONIC-LKS1AF-9V

Part #PANASONIC-LKS1AF-9V
Download 
PANASONIC-LKS1AF-9V
VDE  
TV-5 rated.  
High sensitivity: 250mW  
1a 5A power relays  
LK-S REL
A
Y
S  
FEATURES  
1. High sensitivity  
4. Space-saving slim type  
Base area: Width 11
×
Length 24 mm  
Width .433
×
Length .945 inch  
5. Conforms to the various safety  
standards  
A nominal operating power of 250mW  
and high sensitivity make it ideal for  
energy saving (LK relay is 530mW).  
2. High insulation resistance between  
contact and coil  
1) Creepage distance and clearances  
between contact and coil: Min. 6 mm
.236  
inch
(In compliance with IEC60065)  
2) Surge withstand voltage between  
contact and coil: 10,000 V  
UL, CSA, VDE, TÜV and SEMKO  
approved  
TYPICAL APPLICATIONS  
• Audio visual equipment  
• Office equipment  
3. Popular terminal pitch in AV  
equipment field  
RoHS compliant  
• Home appliances  
ORDERING INFORMATION  
LKS 1a  
F
LK-S relay  
Contact arrangement  
1a: 1 Form A  
Protective construction  
F: Flux-resistant type  
Nominal coil voltage (DC)  
5V, 9V, 12V, 24V  
Notes: Certified by UL, CSA, TÜV and SEMKO  
VDE approved type is available. Please consult us for details.  
TYPES  
Contact arrangement  
Nominal coil voltage  
5V DC  
Part No.  
LKS1aF-5V  
LKS1aF-9V  
LKS1aF-12V  
LKS1aF-24V  
9V DC  
1 Form A  
12V DC  
24V DC  
Standard packing Carton: 100 pcs. Case: 500 pcs.  
Note: 6
V
,
1
8 V DC types are also available. Please consult us for details.  
RATING  
1. Coil data  
Nominal operating  
current  
[ 10%]
 
(at 20
°
C
68
°
F
)  
Nominal coil  
voltage  
Pick-up voltage  
(at 20
°
C
68
°
F
)  
Drop-out voltage  
(at 20
°
C
68
°
F
)  
Coil resistance  
[ 10%]
 
(at 20
°
C
68
°
F
)  
Nominal operating  
power  
Max. applied voltage  
(at 20
°
C
68
°
F
)  
5V DC  
9V DC  
50mA  
27.8mA  
20.8mA  
10.4mA  
100
Ω  
324
Ω  
576
Ω  
6.5V DC  
11.7V DC  
15.6V DC  
31.2V DC  
70%V or less of  
nominal voltage  
(Initial)  
10%V or more of  
nominal voltage  
(Initial)  
250mW  
12V DC  
24V DC  
2,304
Ω  
ASCTB80E 201201-T  
Panasonic Corporation
 
Automation Controls Business Unit
 
industrial.panasonic.com/ac/e  

LK-S  
2. Specifications  
Characteristics  
Item  
Specifications  
Arrangement  
Contact resistance (Initial)  
1 Form A  
Contact  
Rating  
Max. 100 m
Ω
(By voltage drop 6 V DC 1A)  
AgSnO
2
type  
Contact material  
Nominal switching capacity (resistive load)  
Max. switching power (resistive load)  
Max. switching voltage  
5A 277V AC  
1,385VA  
277V AC  
Max. switching current  
5A (AC)  
Min. switching capacity*

1  

100mA, 5V DC  
Insulation resistance (Initial)  
Min. 1,000M
Ω
(at 500V DC) Measurement at same location as “Breakdown voltage” section.  
1,000 Vrms for 1 min. (Detection current: 10 mA)  
4,000 Vrms for 1 min. (Detection current: 10 mA)  
Between open contacts  
Between contact and coil  
Breakdown voltage  
(Initial)  
Max. 35
°
C
95
°
F
(By resistive method, nominal coil voltage applied to the coil;  
contact carrying current: 5A, at 70
°
C
158
°
F
)  
T
e
mperature rise (coil)  
Electrical  
characteristics  
Surge breakdown voltage*

2  

(Between contact and coil) (Initial)  
10,000 V  
Operate time (at nominal voltage) (at 20
°
C
68
°
F
)  
(Initial)  
Max. 15 ms (excluding contact bounce time.)  
Release time (at nominal voltage) (at 20
°
C
68
°
F
)  
(Initial)  
Max. 5 ms (excluding contact bounce time) (Without diode)  
Functional  
Shock resistance  
200 m/s

2

(Half-wave pulse of sine wave: 11 ms; detection time: 10
µ
s.)  
1,000 m/s

2

(Half-wave pulse of sine wave: 6 ms.)  
10 to 55 Hz at double amplitude of 1.5 mm (Detection time: 10
µ
s.)  
10 to 55 Hz at double amplitude of 1.5 mm  
Destructive  
Mechanical  
characteristics  
Functional  
Vibration resistance  
Destructive  
Mechanical (at 180 times/min.)  
Electrical (at 20 times/min.)  
Min. 10

6  

Expected life  
Min. 10

5

(ON:OFF = 1.5s:1.5s, at nominal switching capacity)  
Ambient temperature: –40
°
C to +70
°
C
–40
°
F to +158
°
F
,  
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature),  
Air pressure: 86 to 106kPa  
Conditions for operation, transport and storage*

3  

Max. operating speed  
Conditions  
Unit weight  
20 times/min. (at nominal switching capacity)  
Approx. 12 g
.42 oz  
Notes: *1. This value can change due to the switching frequenc
y
,
e
nvironmental conditions, and desired reliability level, therefore it is recommended to check this with the  
actual load.  
*2. Wave is standard shock voltage of
 
1.2
×
50
µ
s according to JEC-212-1981  
*3. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage  
conditions in NOTES.  
REFERENCE DATA  
1. Max. switching power (AC resistive load)  
2. Coil temperature rise  
3
.
A
mbient temperature characteristics and coil  
applied voltage  
Contact current: 5 A  
Sample: LKS1aF-12
V
, 6
p
cs.  
Point measured: coil inside  
Contact current: 0 A, 5A  
100  
30  
25  
20  
15  
10  
5
500  
20
°
C 5A  
20
°
C 0A  
400  
70
°
C 5A  
70
°
C 0A  
Allowable ambient temperatures  
against % coil voltages  
(max. inside the coil tem-  
10  
5
300  
perature set as  
115
°
C
239
°
F
)  
200  
1
Cold start  
100  
Pick-up voltage  
0
0
0
10  
100  
0
80  
100  
120  
0
10 20 30 40 50 60 70 80  
Contact voltage, V  
Coil applied voltage, %V  
Ambient temperature,
°
C  
ASCTB80E 201201-T  
Panasonic Corporation
 
Automation Controls Business Unit
 
industrial.panasonic.com/ac/e  

LK-S  
4. Life curve  
Operation frequency: 20 times/min.  
(ON/OFF = 1.5s: 1.5s)  
Ambient temperature: Room temperature  
100  
250V AC resistive load  
10  
1
0
1
2
3
4
5
Contact current, A  
5-(1). Electrical life test  
Change of pick-up and drop-out voltage  
Change of contact resistance  
(5 A 277 V AC, resistive load)  
12  
50  
45  
40  
35  
30  
25  
20  
15  
10  
5
Sample: LKS1aF-12
V
, 6
p
cs.  
Operation frequency: 20 times/min.  
(ON/OFF = 1.5s: 1.5s)  
10  
Pick-up voltage  
Ambient temperature: 20
°
C
68
°
F  
Max.  
8
6
x
Circuit:  
Min.  
Max.  
x
Contact  
welding  
detection  
and Mis-  
contacting  
detection  
circuit  
Min.  
4
Drop-out voltage  
277V AC  
12V DC  
Max.  
x
Min.  
2
0
0
0
5
10  
0
5
10  
No. of operations,
×
10

4  

No. of operations,
×
10

4  

5-(2). Electrical life test  
(UL lamp load test TV-5)  
T
e
sted sample: LKS1aF-12
V
, 6
p
cs.  
• Overload test  
Load: 7.5 A 120 V AC (60 Hz),  
Inrush: 111 A  
Operation frequency: 10 times/min  
(ON: OFF = 1 s: 5 s)  
No. of operations: 50 ope.  
• Endurance test  
Load: 5A 120 V AC (60 Hz),  
Inrush: 78 A  
Operation frequency: 10 times/min  
(ON: OFF = 1 s: 5 s)  
No. of operations: 25,000 ope.  
Change of pick-up and drop-out voltage  
Change of contact resistance  
12  
50  
45  
40  
35  
30  
25  
20  
15  
10  
5
10  
Pick-up voltage  
8
Max.  
x
Min.  
6
4
Max.  
x
Drop-out voltage  
Max.  
x
2
0
Min.  
Min.  
2.5  
0
0
0
2.5  
No. of operations,
×
10

4  

No. of operations,
×
10

4  

ASCTB80E 201201-T  
Panasonic Corporation
 
Automation Controls Business Unit
 
industrial.panasonic.com/ac/e  

LK-S  
The CAD data of the products with a
 
CAD Data
 

DIMENSIONS
(mm
inch
)  
External dimensions  
PC board pattern (Bottom view)  
CAD Data  
2-0.9 dia.  
2-.035 dia.  
2-1.3 dia.  
2-.051 dia.  
16.5  
.650  
7.5  
.295  
Max. 25.0  
.984  
0.5  
.020  
20.0  
.787  
T
o
lerance: 0.1
.004  
4
.157  
0.5 dia.  
.020 dia.  
0.3  
.012  
Schematic (Bottom view)  
0.4  
.016  
1.65  
.065  
Max. 24.0  
.945  
Max. 11.0  
.433  
16.5  
.650  
1.0  
.039  
Dimension:  
Less than 1mm
.039inch
:  
General tolerance  
0.1
.004  
7.5  
.295  
Min. 1mm
.039inch
less than 3mm
.118 inch
: 0.2
 
.008  
Min. 3mm
.118 inch
: 0.3
 
.012  
20.0  
.787  
SAFETY STANDARDS  
UL/C-UL (Recognized)  
CSA (Certified)  
VDE (Certified)  
Contact rating  
TV rating (UL/CSA)  
File No.
 
Rating  
TV-5  
TÜV (Certified)  
Rating  
5A 250V AC (cos
φ
=1.0) 807779  
SEMKO (Certified)  
File No.  
E43149  
Contact rating  
File No.
 
Contact rating  
File No.  
File No.  
B 10 01  
13461 270  
File No.
 
Contact rating  
5A 277V AC  
5A 30V DC  
10A 277V AC  
LR26550  
etc.  
5A 277V AC  
5A 30V DC  
10A 277V AC  
40014390 5A
 
250V AC (cos
φ
=1.0) UL  
3/100A 250V AC  
5/40A 250V AC  
10A 250V AC (cos
φ
=1.0) E43149  
CSA  
LR26550  
ASCTB80E 201201-T  
Panasonic Corporation
 
Automation Controls Business Unit
 
industrial.panasonic.com/ac/e