PANASONIC-ST2-DC5V-F
| Part # | PANASONIC-ST2-DC5V-F |
| Download | PANASONIC-ST2-DC5V-F |
Power relays (Over 2 A)
REL
A
Y
S
ST
1 Form A 1 Form B/2 Form A, 8 A, Polarized power relays
FEATURES
Protective construction
:
Sealed type
8 A, Multi-channel, 1 Form A 1 Form B/2 Form A
contact relay
Dielectric strength: 3,750 Vrms
Surge withstand voltage: 6,000 V
Sockets for PC board and soldering are available
Latching types available
14
31
11
TYPICAL APPLICATIONS
Electric power equipment
Industrial machines
(
Unit
:
mm
)
ORDERING INFORMATION (PART NO. : Ordering part number for Japanese market)
AR 2
F
Operating function
Contact arrangement
Rated coil voltag
e
(
DC
)
Contact material
0
:
Single side stable
1
:
1 Form A 1 Form B
F
:
Au-flashed AgSnO
type
2
Part No.
1 2 3 4 5 7 9
2
:
2 coil latching
2
:
2 Form A
Rated coil voltag
e
(
V
)
3 6
12 24
9 48 5
ORDERING INFORMATION (TYPE NO. : Ordering part number for non Japanese market)
ST
F
Contact arrangement
1
:
1 Form A 1 Form B
2
:
2 Form A
Operating function
Nil
:
Single side stable
L2
:
2 coil latching
Rated coil voltag
e
(
DC
)
3, 5, 6, 9, 12, 24, 48V
Contact material
F
:
Au-flashed AgSnO
type
2
Panasonic Corporation 2022
ASCTB210E 202202
industrial.panasonic.com/ac/e/
ー 1 ー
2022.02
Power relays (Over 2 A) ST RELAYS
TYPES
” Type No. ” is ordering part number for non Japanese market. ” Part No. ” is ordering part number for Japanese market.
Single side stable
Type No.
Part No.
AR
2011
2
coil latching
Standard packing
Contact
arrangement
Rated coil
voltage
Type No.
Part No.
AR
2211
F
Inner carton
Outer carton
3
5
6
9
V DC
V DC
V DC
V DC
ST
1
ST
1
ST
1
ST
1
ST
1
ST
1
ST
1
ST
2
ST
2
ST
2
ST
2
ST
2
ST
2
ST
2
-DC
-DC
-DC
-DC
3
V-F
5
V-F
6
V-F
9
V-F
F
ST
ST
ST
ST
ST
ST
ST
ST
ST
ST
ST
ST
ST
ST
1
1
1
1
1
1
1
2
2
2
2
2
2
2
-L
-L
-L
-L
-L
-L
-L
-L
-L
-L
-L
-L
-L
-L
2
2
2
2
2
2
2
2
2
2
2
2
2
2
-DC
-DC
-DC
-DC
3
5
6
9
V-F
V-F
V-F
V-F
AR
2019
AR
2012
AR
2015
AR
2013
AR
2014
AR
2017
AR
2021
AR
2029
AR
2022
AR
2025
AR
2023
AR
2024
AR
2027
F
F
F
F
F
F
F
F
F
F
F
F
F
AR
2219
AR
2212
AR
2215
AR
2213
AR
2214
AR
2217
AR
2221
AR
2229
AR
2222
AR
2225
AR
2223
AR
2224
AR
2227
F
F
F
F
F
F
F
F
F
F
F
F
F
1
1
Form A
Form B
12
V DC
24
V DC
48
V DC
-DC
12
V-F
-DC
24
V-F
-DC
48
V-F
-DC
12
V-F
-DC
24
V-F
-DC
48
V-F
50
pcs.
500
pcs.
3
5
6
9
V DC
V DC
V DC
V DC
-DC
-DC
-DC
-DC
3
V-F
5
V-F
6
V-F
9
V-F
-DC
-DC
-DC
-DC
3
5
6
9
V-F
V-F
V-F
V-F
2
Form A
12
V DC
24
V DC
48
V DC
-DC
12
V-F
-DC
24
V-F
-DC
48
V-F
-DC
12
V-F
-DC
24
V-F
-DC
48
V-F
For the sockets, please refer to the “PC board socket/Soldering socket”.
RATING
Coil data
• Operating characteristics such as ‘Operate voltage’ and ‘Release voltage’ are influenced by mounting conditions, ambient
temperature, etc.
Therefore, please use the relay within ±5% of rated coil voltage.
• ‘Initial’ means the condition of products at the time of delivery.
Single side stable
Rated operating
current
(±
10
%, at
20
°C)
Max. allowable
voltage
Rated coil
voltage
Operate voltage*
(at
20
°C)
Release voltage*
(at
20
°C)
Coil resistance
(±
10
%, at
20
°C)
Rated operating power
(at
20
°C)
3
5
6
9
V DC
V DC
V DC
V DC
78
47
.
9
6
mA
mA
38
105
150
360
600
400
000
Ω
Ω
Ω
Ω
Ω
Ω
Ω
.
40
mA
25
mA
20
mA
10
mA
Max.
80
% V of
rated coil voltage
(Initial)
Min.
10
% V of
rated coil voltage
(Initial)
150
% V of rated
coil voltage
Approx.
240
mW
12
V DC
24
V DC
2
9
,
,
48
V DC
5
.
3
mA
*square, pulse drive
2 coil latching
Rated operating
current
(±
10
%, at
20
°C)
Coil resistance
(±
10
%, at
20
°C)
Max. allowable
voltage
Rated operating power
Rated coil
voltage
Set voltage*
(at
20
°C)
Reset voltage*
(at
20
°C)
(at
20
°C)
Set coil
Reset coil
Set coil
40
Reset coil
Set coil
Reset coil
3
5
6
9
V DC
V DC
V DC
V DC
75
mA
45
mA
75
mA
45
mA
Ω
40
110
155
360
640
400
200
Ω
Ω
Ω
Ω
Ω
Ω
Ω
110
155
360
640
400
200
Ω
Ω
Ω
Ω
Ω
Ω
37
25
mA
18
mA
10
mA
mA
.
5
mA
37
25
mA
18
mA
10
mA
mA
.
5
mA
Max.
80
% V of
rated coil voltage
(Initial)
Max.
80
% V of
rated coil voltage
(Initial)
Approx.
Approx.
150
% V of rated
coil voltage
240
mW
240
mW
12
V DC
24
V DC
.
8
.
8
2
,
,
2
,
48
V DC
4
.
7
4
.
7
10
10
,
*square, pulse drive
Panasonic Corporation Electromechanical Control Business Division
ー 2 ー
Panasonic Corporation 2022
ASCTB210E 202202
industrial.panasonic.com/ac/e/
Power relays (Over 2 A) ST RELAYS
Specifications
Item
Specifications
Contact arrangement
1
Form A
Max.
30
mΩ (by voltage drop
Au-flashed AgSnO
type
30
V DC
1
Form B,
2
Form A
Contact resistance
(initial)
6
V DC
1
A)
Contact material
2
Contact rating
(resistive)
8
2
A
250
V AC,
5
A
Contact data
Max. switching power
(resistive)
,
000
VA,
150
W
Max. switching voltage
250
V AC,
30
V DC
Max. switching current
8
A (AC),
100
mA
Min.
000
MΩ (at
500
V DC, Measured portion is the same as the case of dielectric strength.)
5
A (DC)
Min. switching load
5
V DC
(reference value)*
1
Insulation resistance (initial)
Between open contacts
1
,
1
2
,
200
Vrms for
000
Vrms for
1
1
min (detection current:
10
mA)
min (detection current:
10
mA)
Between contact sets
,
Dielectric
strength (initial)
Between contact and
coil
3
6
,
750
Vrms for
1
min (detection current:
10
mA)
Surge withstand
Between contact and
,
000
V
voltage (initial)*
2
coil
Time
Operate (Set) time
Max.
15
ms (Max.
15
ms) at rated coil voltage (at
20
°C, without bounce)
characteristics
(initial)
Release (Reset) time
Max.
10
ms (Max.
15
ms) at rated coil voltage (at
20
°C, without bounce, without diode)
196
m/s
2
(half-sine shock pulse:
11
ms, detection time:
10
μs)
980
m/s
2
(half-sine shock pulse:
6
ms)
Functional
Shock
resistance
Destructive
Functional
10
to
55
Hz (at double amplitude of
10
to
55
Hz (at double amplitude of
2
3
mm, detection time:
10
μs)
Vibration
resistance
Destructive
Mechanical life
mm)
Expected life
Conditions
Unit weight
Min.
10
x
10
6
ope. (switching frequency: at
180
times/min)
Conditions for usage,
Ambient temperature: –
40
to +
60
°C, Humidity:
5
to
85
% RH (Avoid icing and condensation)
transport and storage*
2
Approx.
10
g
*1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load.
*2. Wave is standard shock voltage of ±1.2×50 μs according to JEC-212-1981
*3. For ambient temperature, please read “GUIDELINES FOR RELAY USAGE”.
Expected electrical life
Conditions: Resistive load, switching frequency ON : OFF = 1 s : 5 s
Type
Switching capacity
250
V AC
Number of operations
1
Form A
1
Form B,
2
Form A
8
A
Min.
100
x
10
3
ope.
REFERENCE DATA
1.Max. switching capacity
2.Coil temperature characteristics
10
100
90
AC
5
resistive load
80
AC
inductive load
70
(
co
s
φ
=
0.4
)
2
1
60
50
40
30
20
10
0
Contact current 8A
DC resistive load
0A
DC
inductive load
(
L/R
=
40ms
)
0.5
0.2
0
20
50
100 200
300 600
1,000
Contact voltag
e
(
V
)
0.2
0.4
0.6
0.8
1.0
1.2
Coil operating pow
e
(
r W
)
Panasonic Corporation Electromechanical Control Business Division
ー 3 ー
Panasonic Corporation 2022
ASCTB210E 202202
industrial.panasonic.com/ac/e/
Power relays (Over 2 A) ST RELAYS
3-1.Ambient temperature characteristics
3-2.Ambient temperature characteristics
4.Influence of proximity mounting
(1 Form A 1 Form B: Average)
(2 Form A: Average)
Tested sample
:
AR2013F, 4 pcs.
Tested sample
:
AR2024
F
, 4 pcs.
40
30
20
30
20
30
20
10
10
Release voltage
10
Release voltage
Operate voltage
60 80
Operate voltage
60 80
Ambient
temperatur
e
(℃)
ー
60
ー
40
ー
20
0
ー
60
ー
40
ー
20
Release voltage
0
0
20 40
20 40
Operate voltage
Ambient
ー
10
temperatur
e
(℃)
ー
10
ー
10
ー
20
ー
30
ー
40
ー
20
ー
30
ー
20
ー
30
5
10
15
20
Inter-relay distanc
e
(
mm
)
CAD
The CAD data of the products with a “CAD” mark can be downloaded from our Website.
DIMENSIONS
Unit: mm
Single side stable
CAD
External dimensions
Recommended
PC board pattern
(BOTTOM VIEW)
1 Form A
Schematic
(BOTTOM VIEW)
(De-energize)
31
14
1 Form A 1 Form B
1
4
6
ー
1.4dia.
-
+
7.62
10.16
7.62
10.16
8
7
6
5
2 Form A
2
ー
0.6dia.
2.54
1
4
-
+
Tolerance
±
0.1
8
7
6
5
4
ー
1
General tolerance
±
0.5
2 coil latching
CAD
External dimensions
Recommended
Schematic
PC board pattern
(BOTTOM VIEW)
1 Form A
(BOTTOM VIEW)
(Reset)
31
14
1 Form A 1 Form B
1
2
3
4
8
ー
1.4dia.
-+
+-
7.62
10.16
7.62
10.16
8
7
6
5
2 Form A
2
ー
1
2.54
1
2
3
4
2
ー
0.6dia.
-+
+-
Tolerance
±
0.1
8
7
6
5
4
ー
1
General tolerance
±
0.5
Panasonic Corporation Electromechanical Control Business Division
ー 4 ー
Panasonic Corporation 2022
ASCTB210E 202202
industrial.panasonic.com/ac/e/
Power relays (Over 2 A) ST RELAYS
Each standard may be updated at any time, so please check our Website for the latest information.
SAFETY STANDARDS
UL (Approved)
CSA (Approved)
File No.
Contact rating
File No.
Contact rating
8
A
250
V AC
8
A
A
250
V AC
5
A
30
V DC
5
30
V DC
E43028
2369519
1
1
⁄
4
HP
125
,
250
V AC
4
⁄
HP
125
,
250
V AC
VDE (Approved)
TV rating
File No.
File No.
Contact rating
Contact rating
8
5
4
A
A
A
250
V AC (cosφ =
30
V DC (
ms)
250
V AC (cosφ =
1
.
0
)
UL: E43028
CSA: 2369519
TV-
TV-
3
3
40017740
0
0
.
4
)
INSULATION CHARACTERISTICS (IEC61810-1)
Item
Characteristics
Clearance/Creepage distance (IEC61810-
1
)
Min.
1
.
5
/
2
.
5
mm
Category of protection (IEC61810-
Tracking resistance (IEC60112)
Insulation material group
Over voltage category
Rated voltage
1
)
RT III
PTI
100
III a
II
250
V
Pollution degree
2
Type of insulation (Between contact and coil)
Type of insulation (Between open contacts)
Note: EN/IEC VDE Certified.
Basic insulation
Micro disconnection
GUIDELINES FOR USAGE
For cautions for use, please read “GUIDELINES FOR REL
A
Y
U
SAGE”.
Cautions for usage of ST relays
• The standard values of operate (set) and release (reset)
voltage are for when the relay is installed with the terminals
oriented downward.
Set and reset pulse time
Regarding the set and reset pulse time of the latching type, for
the purpose of reliable operation under ambient temperature
fluctuations and different operating conditions, we recommend
setting the coil applied set and reset pulse time to 50 ms or
more at the rated coil voltage.
• When using, please be aware that the N.C. and N.O. sides
of 1 Form A 1 Form B type may go on simultaneously at
operate time and release time.
Panasonic Corporation Electromechanical Control Business Division
ー 5 ー
Panasonic Corporation 2022
ASCTB210E 202202
industrial.panasonic.com/ac/e/
Power relays (Over 2 A) ST RELAYS
PC board socket/Soldering socket
Terminal socket
for PC board
Terminal socket
for soldering
TYPES
Standard packing
Product name
Type No.
Part No.
Inner carton
Outer carton
PC board socket
ST-PS
ST-SS
AR
2800
AR
2806
50
pcs.
500
pcs.
Soldering socket
RATING
Item
Specifications
Between contact and coil:
4
,
000
Vrms for
2
,
000
Vrms for
1
min (detection current:
10
mA)
1
min (detection current:
10
mA)
Dielectric strength (initial)
Between contact and terminal:
Between terminals: Min.
000
MΩ
(at
500
V DC, Measured portion is the same as the case of dielectric strength.)
10
Ambient temperature: –
40
to +
60
°C
Humidity:
to
85
% RH (Avoid icing and condensation)
1
,
Insulation resistance (initial)
Maximum carrying current
A
Conditions for usage, transport and storage
5
Panasonic Corporation Electromechanical Control Business Division
ー 6 ー
Panasonic Corporation 2022
ASCTB210E 202202
industrial.panasonic.com/ac/e/
Power relays (Over 2 A) ST RELAYS
CAD
The CAD data of the products with a “CAD” mark can be downloaded from our Website.
DIMENSIONS
Unit: mm
PC board Socket
Soldering socket
External dimensions
CAD
External dimensions
CAD
35.4
±
0.6
35.4
±
0.6
15.6
±
0.6
15.6
±
0.6
8
ー
1.05
8
ー
0.27
10.16
14.6
8
ー
2.3
8
ー
0.27
10.16
14.6
7.62
10.16
31.6
7.62
7.62
10.16
31.6
7.62
General tolerance
±
0.5
General tolerance
±
0.5
Recommended PC board pattern
(BOTTOM VIEW)
Panel cut-off
32.5
8
ー
1.5dia.
Tolerance
±
0.1
7.62
10.16
7.62
●
The range for chassis thickness is 0.6 to 2.2 mm.
●
If the chassis hole is punched with a press,
set so the release R on the front sid
e
(
A side
)
.
Tolerance
±
0.1
Claw for chassis
fastening
A side
Chassis t = 0.6 to 2.2
HANDLING
Mounting method of relay
Removing method of relay
1) Align the direction of relay and
socket.
1) When removing the relay, completely
release the hooks on both sides and
pull the relay out.
ST relay
2) In case there is not enough
space to grasp relay with
fingers, after completely
removing both hooks, use
screwdrivers in the way
shown.
2) Insert the relay all the way in, so it is securely in place.
3) Press the hook section in the direction of the arrow and firmly
secure the relay with the hook.
Relay case
cross-section
3) Exercise care when removing relays. If greater than necessary
force is applied at the socket hooks, deformation may alter the
dimensions so that the hook will no longer catch, and other
damage may also occur.
Hinge
mechanism
(
Before fastening
)
(
Fastening complete
)
Panasonic Corporation Electromechanical Control Business Division
ー 7 ー
Panasonic Corporation 2022
ASCTB210E 202202
industrial.panasonic.com/ac/e/
GUIDELINES FOR POWER, HIGH-CAPACITY DC CUT OFF AND SAFETY RELAYS USAGE
For cautions for use, please read “GUIDELINES FOR REL
A
Y
U
SAGE”.
Precautions for Coil Input
Long term current carrying
Maximum allowable voltage and temperature rise
Proper usage requires that the rated coil voltage be impressed on
the coil. Note, however, that if a voltage greater than or equal to the
maximum continuous voltage is impressed on the coil, the coil may
burn or its layers short due to the temperature rise. Furthermore, do
not exceed the usable ambient temperature range listed in the
catalog.
A circuit that will be carrying a current continuously for long periods
without relay switching operation. (circuits for emergency lamps,
alarm devices and error inspection that, for example, revert only
during malfunction and output warnings with form B contacts)
Continuous, long-term current to the coil will facilitate deterioration
of coil insulation and characteristics due to heating of the coil itself.
For circuits such as these, please use a magnetic-hold type latching
relay. If you need to use a single stable relay, use a sealed type
relay that is not easily affected by ambient conditions and make a
failsafe circuit design that considers the possibility of contact failure
or disconnection.
Operate voltage change due to coil temperature rise
In DC relays, after continuous passage of current in the coil, if the
current is turned OF
F
,
t
hen immediately turned ON again, due to the
temperature rise in the coil, the operate voltage will become
somewhat higher. Also, it will be the same as using it in a higher
temperature atmosphere. The resistance/temperature relationship
for copper wire is about 0.4% for 1°C, and with this ratio the coil
resistance increases. That is, in order to operate of the relay, it is
necessary that the voltage be higher than the operate voltage and
the operate voltage rises in accordance with the increase in the
resistance value. However, for some polarized relays, this rate of
change is considerably smaller.
DC Coil operating power
Steady state DC current should be applied to the coil. The wave
form should be rectangular. If it includes ripple, the ripple factor
should be less than 5%.
However, please check with the actual circuit since the electrical
characteristics may vary. The rated coil voltage should be applied to
the coil and the set/reset pulse time of latching type relay differs for
each relays, please refer to the relay’s individual specifications.
Coil connection
When connecting coils of polarized relays, please check coil polarity
(+,-) at the internal connection diagram (Schematic). If any wrong
connection is made, it may cause
unexpected malfunction, like
abnormal heat, fire and so on, and circuit do not work. Avoid
impressing voltages to the set coil and reset coil at the same time.
Ambient Environment
Dew condensation
Usage, Transport, and Storage Conditions
During usage, storage, or transportation, avoid locations subjected
to direct sunlight and maintain normal temperature, humidity and
pressure conditions.
Condensation occurs when the ambient temperature drops suddenly
from a high temperature and humidity, or the relay is suddenly
transferred from a low ambient temperature to a high temperature
and humidity. Condensation causes the failures like insulation
deterioration, wire disconnection and rust etc.
Temperature/Humidity/Pressure
When transporting or storing relays while they are tube packaged,
there are cases the temperature may differ from the allowable
range. In this case be sure to check the individual specifications.
Also allowable humidity level is influenced by temperature, please
check charts shown below and use relays within mentioned
conditions. (Allowable temperature values differ for each relays,
please refer to the relay’s individual specifications.)
Panasonic Corporation does not guarantee the failures caused by
condensation.
The heat conduction by the equipment may accelerate the cooling
of device itself, and the condensation may occur.
Please conduct product evaluations in the worst condition of the
actual usage. (Special attention should be paid when high
temperature heating parts are close to the device. Also please
consider the condensation may occur inside of the device.)
Icing
1)
T
e
mperature:
The tolerance temperature range differs for each relays, please
refer to the relay’s individual specifications
2) Humidity: 5 to 85 % RH
Condensation or other moisture may freeze on relays when the
temperature become lower than 0°C.This icing causes the sticking
of movable portion, the operation delay and the contact conduction
failure etc. Panasonic Corporation does not guarantee the failures
caused by the icing.
3) Pressure: 86 to 106 kPa
Humidity (% RH)
The heat conduction by the equipment may accelerate the cooling
of relay itself and the icing may occur. Please conduct product
evaluations in the worst condition of the actual usage.
Low temperature and low humidity
85
The plastic becomes brittle if the switch is exposed to a low
temperature, low humidity environment for long periods of time.
High temperature and high humidity
Allowable range
Avoid icing
Avoid con
when used at
temperatures
lower than 0
°
C
densation when
used at tem
peratures higher
than 0
°
C
Storage for extended periods of time (including transportation
periods) at high temperature or high humidity levels or in
atmospheres with organic gases or sulfide gases may cause a
sulfide film or oxide film to form on the surfaces of the contacts and/
or it may interfere with the functions. Check out the atmosphere in
which the units are to be stored and transported.
5
40
0
85
Ambient temperature (℃)
Panasonic Corporation Electromechanical Control Business Division
ー 8 ー
Panasonic Corporation 2021
ASCTB412E 202105
industrial.panasonic.com/ac/e/
GUIDELINES FOR POWER, HIGH-CAPACITY DC CUT OFF AND SAFETY RELAYS USAGE
Package
In terms of the packing format used, make every effort to keep the
NOx Generation
When relay is used in an atmosphere high in humidity to switch a
load which easily produces an arc, the NOx created by the arc and
the water absorbed from outside the relay combine to produce nitric
acid.
effects of moisture, organic gases and sulfide gases to the absolute
minimum.
Silicon
When a source of silicone substances (silicone rubber, silicone oil,
silicone coating materials and silicone filling materials etc.) is used
around the relay, the silicone gas (low molecular siloxane etc.) may
be produced.
This corrodes the internal metal parts and adversely affects
operation.
Avoid use at an ambient humidity of 85%RH or higher (at 20°C). If
use at high humidity is unavoidable, please contact our sales
representative.
This silicone gas may penetrate into the inside of the relay. When
the relay is kept and used in this condition, silicone compound may
adhere to the relay contacts which may cause the contact failure.
Do not use any sources of silicone gas around the relay (Including
plastic seal types).
Others
Cleaning
• Although the environmentally sealed type relay (plastic sealed type,
etc.) can be cleaned, avoid immersing the relay into cold liquid (such
as cleaning solvent) immediately after soldering. Doing so may
deteriorate the sealing performance.
• Cleaning with the boiling method is recommended(The temperature
of cleaning liquid should be 40°C or lower ).
Avoid ultrasonic cleaning on relays. Use of ultrasonic cleaning may
cause breaks in the coil or slight sticking of the contacts due to
ultrasonic energy.
Please refer to
“the latest product specifications”
when designing your product.
•Requests to customers:
Panasonic Corporation Electromechanical Control Business Division
ー 9 ー
Panasonic Corporation 2021
ASCTB412E 202105
industrial.panasonic.com/ac/e/
Please contact ……….
Electromechanical Control Business Division
1006, Oaza Kadoma, Kadoma-shi, Osaka 571-8506, Japan
industral.panasonic.com/ac/e/
©Panasonic Corporation 2022
Specifications are subject to change without notice.
ASCTB210E 202202