PANASONIC-TK1-L-H-3V

Part #PANASONIC-TK1-L-H-3V
Download 
PANASONIC-TK1-L-H-3V
4 mm height!  
2 A high capacity  
1 Form C type ultra thin,  
super miniature relay  
TK RELAYS  
4. Initial breakdown voltage:  
1,500 Vrms for 1 min. (Between  
contact and coil)  
5. Nominal operating power:  
High sensitivity of 140mW (Single  
side stable type)  
8. Self-clinching terminal also  
available  
9. Pre-soldering terminal  
10. Sealed construction allows  
automatic washing.  
By using the highly efficient polar  
magnetic circuit “seesaw balance  
mechanism”, a nominal operating  
power of 140 mW (minimum operating  
power of 79 mW) has been achieved.  
6. Outstanding vibration and shock  
resistance  
TYPICAL APPLICATIONS  
1. Computer peripherals  
2. Telephone devices and  
telecommunications equipment  
3. Crime and disaster prevention  
equipment  
Functional shock resistance: 750 m/s

2  

Destructive shock resistance:  
1,000 m/s

2  

4. Machine tools  
Functional vibration resistance:  
10 to 55 Hz (at double amplitude of  
3.3 mm
.130 inch
)  
Destructive vibration resistance:  
10 to 55 Hz (at double amplitude of  
5 mm
.197 inch
)  
FEATURES  
1. Compact and flat type  
10.6(L)
×
9.0(W)
×
4.0(H)
.417(L)
×  
.354(W)
×
.157(H)  
7. The use of gold-clad twin crossbar  
contacts ensures high contact  
reliability.  
2. High contact capacity: 2 A  
3. Outstanding surge resistance  
Surge breakdown voltage between  
contact and coil:  
*We also offer a range of products  
with AgPd contacts suitable for use  
in low level load analog circuits  
(Max. 10V DC 10 mA).  
*SX relays designed for low level  
loads are also available.  
2,500 V 2
×
10
μ
sec. (
T
e
lcordia)  
Surge breakdown voltage between  
open contacts:  
1,500 V 10
×
160
μ
sec. (FCC part 68)  
ORDERING INFORMATION  
TK  
1
Contact arrangement  
1: 1 Form C  
Operating function  
Nil: Single side stable  
L: 1
 
coil latching  
L2: 2 coil latching  
Terminal shape  
Nil: Standard PC board terminal  
H: Self-clinching
 
terminal  
Nominal coil voltage (DC)  
1.5, 3, 4.5, 5, 6, 9, 12, 24V  
Note: In case of 5 V drive circuit, it is recommended to use 4.5 V type relay.  
ds_61018_0000_en_tk: 110509J  
1

TK  
TYPES  
1) Standard PC board terminal  
Single side stable  
Part No.  
1 coil latching  
Part No.  
2 coil latching  
Part No.  
Contact  
arrangement  
Nominal coil  
voltage  
1.5V DC  
3V DC  
TK1-1.5V  
TK1-3V  
TK1-L-1.5V  
TK1-L-3V  
TK1-L-4.5V  
TK1-L-5V  
TK1-L-6V  
TK1-L-9V  
TK1-L-12V  
TK1-L-24V  
TK1-L2-1.5V  
TK1-L2-3V  
TK1-L2-4.5V  
TK1-L2-5V  
TK1-L2-6V  
TK1-L2-9V  
TK1-L2-12V  
TK1-L2-24V  
4.5V DC  
5V DC  
TK1-4.5V  
TK1-5V  
1 Form C  
6V DC  
TK1-6V  
9V DC  
TK1-9V  
12V DC  
24V DC  
TK1-12V  
TK1-24V  
Standard packing: Tube: 50 pcs.; Case: 1,000 pcs.  
2) Self-clinching terminal  
Single side stable  
Part No.  
1 coil latching  
Part No.  
2 coil latching  
Part No.  
Contact  
arrangement  
Nominal coil  
voltage  
1.5V DC  
3V DC  
TK1-H-1.5V  
TK1-H-3V  
TK1-L-H-1.5V  
TK1-L-H-3V  
TK1-L-H-4.5V  
TK1-L-H-5V  
TK1-L-H-6V  
TK1-L-H-9V  
TK1-L-H-12V  
TK1-L-H-24V  
TK1-L2-H-1.5V  
TK1-L2-H-3V  
TK1-L2-H-4.5V  
TK1-L2-H-5V  
TK1-L2-H-6V  
TK1-L2-H-9V  
TK1-L2-H-12V  
TK1-L2-H-24V  
4.5V DC  
5V DC  
TK1-H-4.5V  
TK1-H-5V  
1 Form C  
6V DC  
TK1-H-6V  
9V DC  
TK1-H-9V  
12V DC  
24V DC  
TK1-H-12V  
TK1-H-24V  
Standard packing: Tube: 50 pcs.; Case: 1,000 pcs.  
RATING  
1. Coil data  
1) Single side stable  
Nominal operating  
current  
[
±
10%] (at 20
°
C
68
°
F
)  
Nominal coil  
voltage  
Pick-up voltage  
(at 20
°
C
68
°
F
)  
Drop-out voltage  
(at 20
°
C
68
°
F
)  
Coil resistance  
[
±
10%] (at 20
°
C
68
°
F
)  
Nominal operating  
Max. applied voltage  
(at 20
°
C
68
°
F
)  
power  
140mW  
270mW  
1.5V DC  
3V DC  
93.8mA  
46.7mA  
31mA  
16
Ω  
64.3
Ω  
145
Ω  
178
Ω  
257
Ω  
579
Ω  
1,028
Ω  
4.5V DC  
5V DC  
150%V of  
nominal voltage  
28.1mA  
23.3mA  
15.5mA  
11.7mA  
75%V or less of  
nominal voltage*  
(Initial)  
10%V or more of  
nominal voltage*  
(Initial)  
6V DC  
9V DC  
12V DC  
120%V of  
nominal voltage  
24V DC  
11.3mA  
2,133
Ω  
2) 1 coil latching  
Nominal operating  
current  
[
±
10%] (at 20
°
C
68
°
F
)  
Nominal coil  
voltage  
Set voltage  
(at 20
°
C
68
°
F
)  
Reset voltage  
(at 20
°
C
68
°
F
)  
Coil resistance  
[
±
10%] (at 20
°
C
68
°
F
)  
Nominal operating  
power  
Max. applied voltage  
(at 20
°
C
68
°
F
)  
1.5V DC  
3V DC  
66.7mA  
33.3mA  
22.2mA  
20mA  
22.5
Ω  
90
Ω  
4.5V DC  
5V DC  
202.5
Ω  
250
Ω  
360
Ω  
810
Ω  
1,440
Ω  
150%V of  
nominal voltage  
100mW  
150mW  
75%V or less of  
nominal voltage*  
(Initial)  
75%V or less of  
nominal voltage*  
(Initial)  
6V DC  
16.7mA  
11.1mA  
8.3mA  
9V DC  
12V DC  
120%V of  
nominal voltage  
24V DC  
6.3mA  
3,840
Ω  
*Pulse drive (JIS C 5442-1986)  
ds_61018_0000_en_tk: 110509J  
2

TK  
3) 2 coil latching  
Nominal operating  
current  
[
±
10%] (at 20
°
C
68
°
F
)  
Coil resistance  
[
±
10%] (at 20
°
C
68
°
F
)  
Nominal operating  
power  
Nominal coil  
voltage  
Set voltage  
(at 20
°
C
68
°
F
)  
Reset voltage  
(at 20
°
C
68
°
F
)  
Max. applied voltage  
(at 20
°
C
68
°
F
)  
Set coil  
133.9mA  
66.7mA  
44.5mA  
40mA  
Reset coil  
133.9mA  
66.7mA  
44.5mA  
40mA  
Set coil  
11.2
Ω  
45
Ω  
Reset coil  
11.2
Ω  
45
Ω  
Set coil  
Reset coil  
1.5V DC  
3V DC  
4.5V DC  
5V DC  
6V DC  
9V DC  
101.2
Ω  
125
Ω  
180
Ω  
405
Ω  
101.2
Ω  
125
Ω  
150%V of  
nominal voltage  
200mW  
200mW  
75%V or less of  
nominal voltage*  
(Initial)  
75%V or less of  
nominal voltage*  
(Initial)  
33.3mA  
22.2mA  
33.3mA  
22.2mA  
180
Ω  
405
Ω  
120%V of  
nominal voltage  
12V DC  
24V DC  
20.8mA  
16.7mA  
20.8mA  
16.7mA  
576
Ω  
576
Ω  
250mW  
400mW  
250mW  
400mW  
110%V of  
nominal voltage  
1,440
Ω  
1,440
Ω  
*Pulse drive (JIS C 5442-1986)  
2. Specifications  
Characteristics  
Item  
Specifications  
Arrangement  
Initial contact resistance, max.  
1 Form C  
Contact  
Max. 50 m
Ω
(By voltage drop 6 V DC 1A)  
Ag+Au clad  
Contact material  
Nominal switching capacity  
Max. switching power  
2 A 30 V DC (resistive load)  
60 W (DC) (resistive load)  
220 V DC  
Max. switching voltage  
Max. switching current  
Min. switching capacity (Reference value)*

1  

Single side stable  
2 A  
Rating  
10
μ
A 10mV DC  
140 mW (1.5 to 12 V DC), 270 mW (24 V DC)  
100 mW (1.5 to 12 V DC), 150 mW (24 V DC)  
Nominal operating  
1 coil latching  
power  
2 coil latching  
200 mW (1.5 to 9 V DC), 250 mW (12 V DC), 400 mW (24 V DC)  
Min. 1,000M
Ω
(at 500V DC)  
Measurement at same location as “Initial breakdown voltage” section.  
Insulation resistance (Initial)  
Between open contacts  
Between contact and coil  
Between open contacts  
Between contacts and coil  
750 Vrms for 1 min. (Detection current: 10 mA)  
1,500 Vrms for 1 min. (Detection current: 10 mA)  
1,500 V (10
×
160
μ
s) (FCC Part 68)  
2,500 V (2
×
10
μ
s) (
T
e
lcordia)  
Breakdown voltage  
(Initial)  
Surge breakdown  
voltage (Initial)  
Electrical  
characteristics  
Max. 50
°
C  
T
e
mperature rise (at 20
°
C
68
°
F
)  
(By resistive method, nominal coil voltage applied to the coil; contact carrying current: 2A.)  
Max. 3 ms [Max. 3 ms] (Nominal coil voltage applied to the coil, excluding contact bounce  
time.)  
Operate time [Set time] (at 20
°
C
68
°
F
)  
Release time [Reset time] (at 20
°
C
68
°
F
)  
Max. 2 ms [Max. 3 ms] (Nominal coil voltage applied to the coil, excluding contact bounce  
time.) (without diode)  
Functional  
Shock resistance  
Min. 750 m/s

2

(Half-wave pulse of sine wave: 6 ms; detection time: 10
μ
s.)  
Min. 1,000 m/s

2

(Half-wave pulse of sine wave: 6 ms.)  
10 to 55 Hz at double amplitude of 3.3 mm (Detection time: 10
μ
s.)  
10 to 55 Hz at double amplitude of 5 mm  
Destructive  
Mechanical  
characteristics  
Functional  
Vibration resistance  
Destructive  
Mechanical  
Electrical  
Min. 10

8

(Single side stable), Min. 5
×
10

7

(1 or 2 coil latching) (at 180 cpm)  
Min. 10

5

(2 A 30 V DC resistive) (at 20 cpm)  
Expected life  
Ambient temperature: –40
°
C to 85
°
C
–40
°
F to 185
°
F
*

3

;  
Conditions for operation, transport and storage*

2  

Max. operating speed (at rated load)  
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)  
Conditions  
Unit weight  
20 cpm  
Approx. 1 g
.035 oz.  
Notes: *1
 
This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the  
actual load. (SX relays are available for low level load switching [10V DC, 10mA max. level])  
*2 Refer
 
to 6. Conditions for operation, transport and storage mentioned in

.  
*3 The
 
maximum ambient temperature allows for coil temperature rise at maximum allowable coil voltage.  
As for the applicable range of continuous carrying current against temperature, please refer to “Maximum value of continuous carrying current” chart. (Page 4)  
ds_61018_0000_en_tk: 110509J  
3

TK  
REFERENCE DATA  
1. Maximum value of continuous carrying current  
2. Maximum switching capacity  
3. Life curve  
T
e
st conditions:  
Coil applied voltage: 110% of rated voltage  
Continuous carrying current: 1,000 hours  
3.0  
2.0  
100  
2
DC load  
1.0  
30 V DC resistive  
10  
0.5  
0.4  
1
0
0.3  
0.2  
0
1
2
20 30
 
50  
100  
200 300  
40  
50  
60  
70  
80 85 90  
Switching current, A  
Switching voltage, V  
Ambient temperature,
°
C  
4. Mechanical life  
5. Electrical life (DC load)  
T
e
sted sample: TK1-12
V
, 8
p
cs.  
Switching frequency: 30 Hz  
T
e
sted sample: TK1-12V, 10 pcs.  
Condition: 2 A 30 V DC resistive load, 20 cpm  
Change of pick-up and drop-out voltage  
Change of contact resistance  
100  
90  
100  
90  
100  
90  
80  
80  
70  
60  
50  
40  
80  
Pick-up voltage  
Max.  
Min.  
Pick-up voltage  
Max.  
Min.  
70  
60  
50  
40  
30  
20  
10  
0
70  
60  
50  
40  
Drop-out voltage  
Max.  
Min.  
30  
20  
10  
0
30  
20  
10  
0
Max.  
Min.  
Drop-out voltage  
Max.  
Min.  
10  
100  
1,000  
10,000  
4
10  
10  
4
4
No. of operations,
×
10  
No. of operations,
×
10  
No . of operations,
×
10  
6.-(1) Coil temperature rise  
6.-(2) Coil temperature rise  
T
e
sted sample: TK1-12
V
, 6
p
cs.  
Measured portion: Inside the coil  
Ambient temperature: 25
°
C
77
°
F  
T
e
sted sample: TK1-12V, 6 pcs.  
Measured portion: Inside the coil  
Ambient temperature: 70
°
C
158
°
F  
Room temperature  
0 A  
70
°
C  
0 A  
60  
60  
1 A  
1 A  
2 A  
2 A  
50  
50  
40  
30  
20  
10  
0
40  
30  
20  
10  
0
80 90
 
100 110 120 130 140 150  
Coil applied voltage, %V  
80 90
 
100 110 120 130 140 150  
Coil applied voltage, %V  
7.-(1) Operate/release time characteristics  
T
e
sted sample: TK1-5
V
,
5
0 pcs.  
<Without diode>  
7.-(2) Operate/release time characteristics  
T
e
sted sample: TK1-5
V
, 50 pcs.  
<With diode>  
8. Ambient temperature characteristics  
T
e
sted sample: TK1-12
V
, 5
p
cs.  
40  
Drop-out  
30  
20  
10  
voltage  
4
3
4
3
−
x
−
x
Pick-up  
voltage  
0
–40 –20  
0
20 40
 
60 80  
Ambient  
temperature,
°
C  
2
2
–10  
–20  
Operate time  
Release time  
Max.  
Max.  
Max.  
Max.  
M
M
i
i
n
n
.
.  
1
1
0
Min.  
Min.  
Min.  
Operate time  
–30  
–40  
Release time  
0
80  
90  
100 110 120  
80  
90  
100 110 120  
Coil applied voltage, %V  
Coil applied voltage, %V  
ds_61018_0000_en_tk: 110509J  
4

TK  
9.-(1) High-frequency characteristics  
(Isolation)  
9.-(2) High-frequency characteristics (Insertion  
loss)  
10. Malfunctional shock  
T
e
sted sample: TK1-12V, 6 pcs. (single side stable);  
TK1-L2-12
V
, 6
p
cs. (latching)  
1.8  
1.6  
1.4  
Deenergized  
condition  
(Reset state)  
Energized  
condition  
(Set state)  
Z
,
X X  
Z
,
2
Z
,
Y
980m/s  
Y
Y
X
100  
1.2  
1.0  
0.8  
0.6  
0.4  
0.2  
0
N.O.  
N.C.  
2
2
980m/s  
980m/s  
2
980m/s  
50  
0
,
,
Z
X
2
980m/s  
N.O.  
N.C.  
2
980m/s  
,
Y
10  
100  
1,000  
10  
100  
1,000  
Frequency, MHz  
Frequency, MHz  
11.-(1) Influence of adjacent mounting  
11.-(2) Influence of adjacent mounting  
Pick-up voltage  
ON ON  
5
0
ON  
ON  
5
Pick-up voltage  
Drop-out voltage  
0
–5  
–5  
ON  
ON  
OFF  
5
0
5
0
OFF OFF  
Drop-out voltage  
OFF  
–5  
–5  
OFF  
OFF  
0
5
0
5
.197  
.197  
Inter-relay distance
 
, mm
inch  
Inter-relay distance
 
, mm
inch  
12. Actual load test (35 mA 48 V DC wire spring  
relay load)  
Change of pick-up and drop-out voltage  
Change of contact resistance  
100  
90  
100  
N.C.  
N.O.  
90  
80  
70  
60  
50  
40  
30  
20  
10  
0
80  
Pick-up voltage  
Circuit  
Max.  
Min.  
70  
60  
50  
40  
458
Ω  
+
0.08
μ
F  
48 V DC  
0.08
μ
F  
5
4
Max.  
30  
20  
10  
0
Drop-out voltage  
–
Max.  
Min.  
Min.  
Max.  
Min.  
458
Ω  
Wire spring relay  
10  
20  
30  
40  
50  
10  
20  
30  
40  
50  
4
4
No. of operations,
×
10  
No. of operations,
×
10  
ds_61018_0000_en_tk: 110509J  
5

TK  
DIMENSIONS
(mm
inch
)  
External dimensions  
PC board pattern (Bottom view)  
Standard PC board terminal  
5.08  
.200  
6-1.0 dia. holes  
6-.039 dia. holes  
10.6  
.417  
9
.354  
2.54  
.100  
4 3.75  
.157 .148  
3.5  
7.62  
.300  
0.5  
.020  
0.25  
.010  
.138  
0.25  
.010  
7.62  
.300  
2.54  
.100  
2.54  
.100  
2.54  
.100  
T
o
lerance:
±
0.1
±
.004  
Self-clinching terminal  
Schematic (Bottom view)  
1-coil latching  
Single side stable  
2-coil latching  
10.6  
.417  
9
.354  
1
2
3
1
2
3
1
2
3
4 3.75  
.157 .148  
+
−
−
+
+
−
+
3.5  
.138  
0.5  
0.25  
.010  
0.25  
.010  
2.54  
.100  
.020  
7.62  
.300  
2.54  
.100  
6
5
4
6
5
4
6
5
4
Direction indication  
Direction indication  
Direction indication  
General tolerance:
±
0.3
±
.012  
(Deenergized condition)  
(Reset condition)  
(Reset condition)  
NOTES  
1. Packing style  
The relay is packed in a tube with the  
relay orientation mark on the left side, as  
shown in the figure below.  
Orientation (indicates PIN No.1) stripe  
Stopper (green)  
2. Automatic insertion  
To
m
aintain the internal function of the  
relay, the chucking pressure should not  
exceed the values below.  
Chucking pressure in the direction A:  
9.8 N {1 kgf} or less  
Chucking pressure in the direction B:  
29.4 N {3 kgf} or less  
Chucking pressure in the direction C:  
9.8 N {1 kgf} or less  
mm
inch  
Direction A
 
Direction B
 
Direction C  
C
B
A
(4)  
(5)  
6
5
4
(6)  
3
.118  
6
.236  
3
2
1
2
3
1
Please chuck the  
portion.  
Avoid chucking the center of the relay.  
In addition, excessive chucking pressure  
to the pinpoint of the relay should be  
avoided.  
For Cautions for Use, see

.  
ds_61018_0000_en_tk: 110509J  
6