PANASONIC-TQ2H-L2-5V
| Part # | PANASONIC-TQ2H-L2-5V |
| Download | PANASONIC-TQ2H-L2-5V |
Signal Relays ( 2 A or less )
TQ RELAYS
Product Catalog
2023.1
Signal Relays ( 2 A or less )
TQ RELAYS
Flat, 5 mm 2 Form C, 2 A, Surface mount terminal relays
FEATURES
Protective construction
:
Sealed type
●3
t
ypes of terminal shapes:
PC board terminal ( standard/self-clinching terminal )
Surface-mount terminal
9
14
●
C
onfort to FCC Part68:
5
Surge withstand voltage 1,500 V ( between open contacts )
●
M
.B.B. contact available
9
14
●
S
urface-mount terminal conform to JIS
C0806 standard
5.6
TYPICAL APPLICATIONS
●
T
elecommunications and measurement
equipment
(
Unit
:
mm
)
●
T
elephone related equipment
●
O
A equipment
●
I
ndustrial machines
ORDERING INFORMATION ( PART NO. : Ordering part number for Japanese market )
ATQ 2
Terminal shape / Operating function
Contact material
Packing style*
3
0
:
Standard PC board terminal type or
Surface-mount terminal
Nil
:
Standard contact
22
:
MBB conatct
Ni
l
:
Tube packing
X
:
Tape and re
e
(
l picked
from 1/2/3/4/5-pin side
)
Z
:
Tape and reel packin
g
(
picked from the 6/7/8/9/10-pin side
)
W
:
Tape and reel packing (picked from the 1/2/3/4/5-pin side)
With humidity indicator and silica gel in moisture proof bag*
4
Y
:
Tape and reel packing (picked from the 6/7/8/9/10-pin side)
With humidity indicator and silica gel in moisture proof bag*
4
Single side stable
(PC board terminal ,
(Standard/Self-clinching terminal) only)
1
:
Standard PC board terminal type or
Surface-mount terminal
1 coil latching
Rated coil voltage (DC)*
1,
*
2
0
:
1.5 V,
1
:
3
V
,
2
:
6
V
,
3
:
12 V,
4
:
24 V,
5
:
48 V,
6
:
4.5 V,
7
:
9
V
,
9
:
5 V
2
:
Standard PC board terminal type or
Surface-mount terminal
2 coil latching (L2)
Surface-mount type
Nil
:
PC board terminal ,
(Standard/Self-clinching terminal)
SA
:
SA type
SL
:
SL type
SS
:
SS type
3
:
PC board terminal (Self-clinching) terminal
Single side stable
4
:
PC board terminal (Self-clinching) terminal
1 coil latching
5
:
PC board terminal (Self-clinching) terminal
2 coil latching
Contact arrangement
2
:
2 Form C (2 Form D)
*1: 48
V coil type: Single side stable only
*2: In
case of 5 V transistor drive circuit, it is recommended to use 4.5 V type relay.
*3: Th
e
“
W
”
an
d
“
Y
”
at the end of the part number is only available for SA and SS.
*4: Each
reel is packed with humidity indicators and silica gel in the moisuture proof pack.
Panasonic Industry Co., Ltd. Electromechanical Control Business Division
industrial.panasonic.com/ac/e/
Panasonic Industry Co., Ltd. 2023
ASCTB14E 202301
ー 1 ー
Signal Relays ( 2 A or less ) TQ RELAYS
ORDERING INFORMATION ( TYPE NO. : Ordering part number for non Japanese market )
TQ
Packing style*
3
Ni
l
:
Tube packing
Terminal shape
MBB function
X
:
Tape and re
e
(
l picked
from 1/2/3/4/5-pin side
)
Ni
l
:
Standard PC board terminal
H
:
Self-clinching terminal
SA
:
SA type
Nil
:
Standar
d
(
B.B.M.
)
type
2M
:
M.B.B. type
Z
:
Tape and reel packin
g
(
picked from the 6/7/8/9/10-pin side
)
W
:
Tape and reel packing (picked from the 1/2/3/4/5-pin side)
With humidity indicator and silica gel in moisture proof bag*
4
Y
:
Tape and reel packing (picked from the 6/7/8/9/10-pin side)
With humidity indicator and silica gel in moisture proof bag*
4
SL
:
SL type
SS
:
SS type
Operating function
Ni
l
:
Single side stable
L
:
1 coil latching
L2
:
2 coil latching
Contact arrangement
2
:
2 Form C (2 Form D)
Rated coil voltag
e
(
DC
)
*
1,2
1.
5
(
SMD only
)
, 3, 4.5, 5, 6, 9, 12, 24, 48V
*1: 48
V coil type: Single side stable only
*2: In
case of 5 V transistor drive circuit, it is recommended to use 4.5 V type relay.
*3: Th
e
“
W
”
an
d
“
Y
”
at the end of the part number is only available for SA and SS.
*4: Each
reel is packed with humidity indicators and silica gel in the moisuture proof pack.
TYPES
” Type No. ” is ordering part number for non Japanese market. ” Part No. ” is ordering part number for Japanese market.
■ Standard contact
● PC board terminal ( standard ): Tube packing
Single side stable
1 coil latching
2 coil latching
Standard packing
Contact
arrangement
Rated coil
voltage
Carton
Type No.
Part No.
Type No.
Part No.
Type No.
Part No.
Outer carton
( 1 Tube packing )
3
V DC
TQ2-3V
TQ2-4.5V
TQ2-5V
TQ2-6V
TQ2-9V
TQ2-12V
TQ2-24V
TQ2-48V
ATQ201
ATQ206
ATQ209
ATQ202
ATQ207
ATQ203
ATQ204
ATQ205
TQ2-L-3V
TQ2-L-4.5V
TQ2-L-5V
TQ2-L-6V
TQ2-L-9V
TQ2-L-12V
TQ2-L-24V
-
ATQ211
ATQ216
ATQ219
ATQ212
ATQ217
ATQ213
ATQ214
-
TQ2-L2-3V
TQ2-L2-4.5V
TQ2-L2-5V
TQ2-L2-6V
TQ2-L2-9V
TQ2-L2-12V
TQ2-L2-24V
-
ATQ221
ATQ226
ATQ229
ATQ222
ATQ227
ATQ223
ATQ224
-
4.5 V DC
5
6
9
V DC
V DC
V DC
2 Form C
50 pcs.
1,000 pcs.
12 V
DC
24 V
DC
48 V
DC
● PC board terminal ( self-clinching terminal ): Tube packing
Single side stable
1 coil latching
2 coil latching
Standard packing
Contact
arrangement
Rated coil
voltage
Carton
Type No.
Part No.
Type No.
Part No.
Type No.
Part No.
Outer carton
( 1 Tube packing )
3
V DC
TQ2H-3V
TQ2H-4.5V
TQ2H-5V
TQ2H-6V
TQ2H-9V
TQ2H-12V
TQ2H-24V
TQ2H-48V
ATQ231
ATQ236
ATQ239
ATQ232
ATQ237
ATQ233
ATQ234
ATQ235
TQ2H-L-3V
TQ2H-L-4.5V
TQ2H-L-5V
TQ2H-L-6V
TQ2H-L-9V
TQ2H-L-12V
TQ2H-L-24V
-
ATQ241
ATQ246
ATQ249
ATQ242
ATQ247
ATQ243
ATQ244
-
TQ2H-L2-3V
TQ2H-L2-4.5V
TQ2H-L2-5V
TQ2H-L2-6V
TQ2H-L2-9V
TQ2H-L2-12V
TQ2H-L2-24V
-
ATQ251
ATQ256
ATQ259
ATQ252
ATQ257
ATQ253
ATQ254
-
4.5 V DC
5
6
9
V DC
V DC
V DC
2 Form C
50 pcs.
1,000 pcs.
12 V
DC
24 V
DC
48 V
DC
Note) The products ( ATQ***25 ) designed to withstand strong vibration caused, for example, by the use of terminal cutters, can also be ordered.
However, please inquire our sales representative for details, if you need parts for use in low level load.
Panasonic Industry Co., Ltd. Electromechanical Control Business Division
industrial.panasonic.com/ac/e/
Panasonic Industry Co., Ltd. 2023
ASCTB14E 202301
ー 2 ー
Signal Relays ( 2 A or less ) TQ RELAYS
■ MBB contact
● Standard PC board terminal and self-clinching terminal: Tube packing
Standard
Single side stable
Self-clinching terminal*
Standard packing
Contact
arrangement
Rated coil
voltage
Single side stable
Inner carton
Outer carton
( 1 Tube packing )
Type No.
Part No.
Type No.
Part No.
3
V DC
TQ2-2M-3V
TQ2-2M-4.5V
TQ2-2M-5V
TQ2-2M-6V
TQ2-2M-9V
TQ2-2M-12V
TQ2-2M-24V
ATQ20122
ATQ20622
ATQ20922
ATQ20222
ATQ20722
ATQ20322
ATQ20422
TQ2H-2M-3V
TQ2H-2M-4.5V
TQ2H-2M-5V
TQ2H-2M-6V
TQ2H-2M-9V
TQ2H-2M-12V
TQ2H-2M-24V
ATQ23122
ATQ23622
ATQ23922
ATQ23222
ATQ23722
ATQ23322
ATQ23422
4.5 V DC
5
6
9
V DC
V DC
V DC
2 Form D
50 pcs.
1,000 pcs.
12 V
DC
24 V
DC
* Latching types are available by request. Please inquire our sales representative for details.
■ Standard contact
● Surface-mount terminal: Tube packing
Single side stable
1 coil latching
Type No.
Part No.
2 coil latching
Type No.
Part No.
Standard packing
Contact
arrangement
Rated coil
voltage
Carton
Type No.
Part No.
Outer carton
( 1 Tube packing )
1.5 V DC
TQ2S*-1.5V ATQ200S* TQ2S*-L-1.5V ATQ210S*
TQ2S*-L2-1.5V
ATQ220S*
V DC
TQ2S*-3V ATQ201S*
TQ2S*-L-3V ATQ211S*
TQ2S*-L2-3V ATQ221S*
4.5 V DC
TQ2S*-4.5V ATQ206S* TQ2S*-L-4.5V ATQ216S*
TQ2S*-L2-4.5V
ATQ226S*
3
5
6
9
V DC
TQ2S*-5V
V DC
TQ2S*-6V
V DC
TQ2S*-9V
ATQ209S* TQ2S*-L-5V
ATQ202S* TQ2S*-L-6V
ATQ207S* TQ2S*-L-9V
ATQ203S* TQ2S*-L-12V
ATQ204S* TQ2S*-L-24V
ATQ219S* TQ2S*-L2-5V
ATQ212S* TQ2S*-L2-6V
ATQ217S* TQ2S*-L2-9V
ATQ213S* TQ2S*-L2-12V ATQ223S*
ATQ214S* TQ2S*-L2-24V ATQ224S*
ATQ229S*
ATQ222S*
ATQ227S*
2 Form C
50 pcs.
1,000 pcs.
12 V
DC TQ2S*-12V
24 V
DC TQ2S*-24V
48 V
DC TQ2S*-48V
ATQ205S*
-
-
-
-
Note) Enter ” A ” for SA type, ” L ” for SL type and ” S ” for SS type into the ” * “.
● Surface-mount terminal: Tape and reel packing: Z
Single side stable
1 coil latching
2 coil latching
Standard packing
Contact
arrangement
Rated coil
voltage
Carton
Outer
carton
Type No.
Part No.
Type No.
Part No.
Type No.
Part No.
( 1 Reel packing )
1.5 V DC
TQ2S*-1.5V-Z
V DC
TQ2S*-3V-Z
4.5 V DC
TQ2S*-4.5V-Z
ATQ200S*Z
TQ2S*-L-1.5V-Z
ATQ210S*Z
TQ2S*-L2-1.5V-Z
ATQ220S*Z
ATQ221S*Z
ATQ226S*Z
ATQ229S*Z
ATQ222S*Z
ATQ227S*Z
3
ATQ201S*Z TQ2S*-L-3V-Z ATQ211S*Z TQ2S*-L2-3V-Z
ATQ206S*Z
TQ2S*-L-4.5V-Z
ATQ216S*Z
TQ2S*-L2-4.5V-Z
ATQ209S*Z TQ2S*-L-5V-Z ATQ219S*Z TQ2S*-L2-5V-Z
ATQ202S*Z TQ2S*-L-6V-Z ATQ212S*Z TQ2S*-L2-6V-Z
ATQ207S*Z TQ2S*-L-9V-Z ATQ217S*Z TQ2S*-L2-9V-Z
5
6
9
V DC
TQ2S*-5V-Z
V DC
TQ2S*-6V-Z
V DC
TQ2S*-9V-Z
2 Form C
500 pcs.
1,000 pcs.
12 V
DC
TQ2S*-12V-Z
24 V
DC
TQ2S*-24V-Z
48 V
DC
TQ2S*-48V-Z
ATQ203S*Z
ATQ204S*Z
TQ2S*-L-24V-Z
ATQ205S*Z
TQ2S*-L-12V-Z
ATQ213S*Z
TQ2S*-L2-12V-Z
ATQ223S*Z
ATQ214S*Z
TQ2S*-L2-24V-Z
ATQ224S*Z
-
-
-
-
Notes) 1: Enter ” A ” for SA type, ” L ” for SL type and ” S ” for SS type into the ” * “.
2: For taping packaging X, W, and Y, change ” Z ” at the end of the part number to ” X “, ” W “, and ” Y ” ( SA type and SS type only ).
3: The ” W ” and ” Y ” at the end of part number is only available for SA and SS ( Tape and reel packing ).
Panasonic Industry Co., Ltd. Electromechanical Control Business Division
industrial.panasonic.com/ac/e/
Panasonic Industry Co., Ltd. 2023
ASCTB14E 202301
ー 3 ー
Signal Relays ( 2 A or less ) TQ RELAYS
PC BOARD TERMINAL RATING
■ Coil data
• Operating
characteristics such as ” Operate voltage ” and ” Release voltage ” are influenced by mounting conditions or
ambient temperature, etc.
Therefore, please use the relay within ±5 % of rated coil voltage.
• “
Initial ” means the condition of products at the time of delivery.
● Standard contact: Single side stable
Rated operating
current
( ±10 %, at 20 ℃ )
Max. allowable
Rated coil
voltage
Operate voltage*
( at 20 ℃ )
Release voltage*
( at 20 ℃ )
Coil resistance
( ±10 %, at 20 ℃ )
Rated operating
power
voltage
( at 20 ℃ )
3
V DC
46.7 mA
31.1 mA
28.1 mA
23.3 mA
15.5 mA
11.7 mA
8.3 mA
64.3 Ω
4.5 V DC
145
178
Ω
Ω
Ω
Ω
Ω
Ω
5
6
9
V DC
V DC
V DC
140 mW
150 % V of
rated coil voltage
257
Max. 75 % V of
Min. 10 % V of
rated coil voltage
rated coil voltage
579
( Initial )
( Initial )
12 V
DC
24 V
DC
1,028
2,880
200 mW
300 mW
120 % V of
rated coil voltage
48 V
DC
6.3 mA
7,680
Ω
* square, pulse drive ( JIS C 5442 )
● Standard contact: 1 coil latching
Rated operating
current
( ±10 %, at 20 ℃ )
Max. allowable
voltage
( at 20 ℃ )
Rated coil
voltage
Set voltage*
( at 20 ℃ )
Reset voltage*
( at 20 ℃ )
Coil resistance
( ±10 %, at 20 ℃ )
Rated operating
power
3
V DC
33.3 mA
22.2 mA
20 mA
16.7 mA
11.1 mA
8.3 mA
90
202.5 Ω
250
360
810
Ω
4.5 V DC
5
6
9
V DC
V DC
V DC
Ω
Ω
Ω
Ω
Ω
Max. 75 % V of
Max. 75 % V of
100 mW
150 mW
150 % V of
rated coil voltage
rated coil voltage
rated coil voltage
( Initial )
( Initial )
12 V
DC
24 V
DC
1,440
3,840
6.3 mA
* square, pulse drive ( JIS C 5442 )
● Standard contact: 2 coil latching
Rated operating
current
Coil resistance
Rated operating
power
Max. allowable
voltage
Rated coil
voltage
Set voltage*
( at 20 ℃ )
Reset voltage*
( at 20 ℃ )
( ±10 %, at 20 ℃ )
( ±10 %, at 20 ℃ )
( at 20 ℃ )
Set coil
66.7 mA
44.4 mA
40 mA
33.3 mA
22.2 mA
16.7 mA
Reset coil
66.7 mA
44.4 mA
40 mA
33.3 mA
22.2 mA
16.7 mA
Set coil
Reset coil
45
101.2 Ω
Set coil
Reset coil
3
V DC
45
Ω
Ω
4.5 V DC
101.2 Ω
150 % V of
rated coil
voltage
5
6
9
V DC
V DC
V DC
125
180
405
720
Ω
Ω
Ω
Ω
125
180
405
720
Ω
Ω
Ω
Ω
200 mW
200 mW
300 mW
300 mW
Max. 75 % V
of rated coil
voltage
Max. 75 % V
of rated coil
voltage
( Initial )
( Initial )
12 V
DC
120 % V of
rated coil
voltage
24 V
DC
12.5 mA
12.5 mA
1,920
Ω
1,920
Ω
* square, pulse drive ( JIS C 5442 )
● MBB Contact: Single side stable
Operate
voltage*
( at 20 ℃ )
Release
Rated operating
Max. allowable
voltage
( at 20 ℃ )
Rated coil
voltage
Coil resistance
( ±10 %, at 20 ℃ )
Rated operating
power
voltage*
current
( at 20 ℃ )
( ±10 %, at 20 ℃ )
3
V DC
66.7 mA
44.4 mA
40 mA
33.3 mA
22.2 mA
16.7 mA
8.3 mA
45 Ω
101 Ω
125 Ω
180 Ω
405 Ω
720 Ω
2,880 Ω
4.5 V DC
Max. 80 % V
of rated coil
voltage
Min. 10 % V
of rated coil
voltage
5
6
9
V DC
V DC
V DC
150 % V of
rated coil
voltage
200 mW
( Initial )
( Initial )
12 V
DC
24 V
DC
* square, pulse drive ( JIS C 5442 )
Panasonic Industry Co., Ltd. Electromechanical Control Business Division
industrial.panasonic.com/ac/e/
Panasonic Industry Co., Ltd. 2023
ASCTB14E 202301
ー 4 ー
Signal Relays ( 2 A or less ) TQ RELAYS
■ Specifications
Item
Specifications
2 Form D ( M.B.B. contact )
Contact arrangement
2 Form C
Contact resistance
( Initial )
Contact material
Max. 50 mΩ (by voltage drop 6 V DC 1 A)
Ag + Au clad
Contact rating
(resistive)
Max. switching power
( resistive )
1 A 30 V DC, 0.5 A 125 V AC
Contact data
30 W ( DC ), 62.5 VA ( AC )
Max. switching voltage
Max. switching current
Min. switching load
110 V DC, 125 V AC
1 A ( DC ), 1 A ( AC )
10 µA 10 mV DC
1
( reference value )*
Insulation resistance ( Initial )
Min. 1,000 MΩ ( at 500 V DC, Measured portion is the same as the case of dielectric strength. )
750 Vrms for 1 min ( detection current: 10 mA )
300 Vrms for 1 min ( detection current: 10 mA )
Between open contacts
Dielectric
strength
( Initial )
Between contact and coil
1,000 Vrms for 1 min ( detection current: 10 mA )
Between contact sets
1,000 Vrms for 1 min ( detection current: 10 mA )
Surge
withstand
voltage
( Initial )
Between open contacts
1,500 V 10 × 160 µs
Max. 3 ms at rated coil voltage ( at 20 ℃, without bounce )
[ Max. 3 ms ( at 20 ℃ , without bounce ) ]
Operate [ Set ] time
Release [ Reset ] time
Time
characteristics
( Initial )
Max. 3 ms at rated coil voltage ( at 20 ℃ , without bounce, without diode )
[ Max. 3 ms (at 20 ℃ , without bounce ) ]
2
Functional
Destructive
Functional
Destructive
490 m/s
( half-sine shock pulse: 11 ms, detection time: 10 µs )
Shock
resistance
2
980 m/s
( half-sine shock pulse: 6 ms )
10 to 55 Hz ( at double amplitude of: 3 mm, detection time: 10 µs )
10 to 55 Hz ( at double amplitude of: 5 mm )
Vibration
resistance
6
6
Min. 100 × 10
ope.
Min. 10 × 10
ope.
( switching frequency: at 180 times/min )
Expected life
Mechanical life
( switching frequency: at 180 times/min )
Ambient temperature: -40 to +70 ℃
( Allowable temperature is from -40 to +60 ℃
at our standard packing condition. )
Humidity: 5 to 85 % RH
Ambient temperature: -40 to +50 ℃
( Allowable temperature is from -40 to +50 ℃
at our standard packing condition. )
Humidity: 5 to 85 % RH
Conditions for usage,
transport and storage*
Conditions
Unit weight
2
( Avoid icing and condensation )
( Avoid icing and condensation )
Approx. 1.5 g
Note) For AC load, please inquire our sales representative for details.
*1: This value is a rough indication of the lower limit at which switching is possible at micro load level.
This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load.
TX/TX-S/TX-D relay AgPd contact type are available for low level load analog circuit ( 10 V DC, 10 mA max. level ).
*2: For ambient temperature, please refer to the ” GUIDELINES FOR RELAY USAGE “.
■ Electrical life
Conditions: resistive load, switching frequency at 20 times/minute
Type
Switching capacity
30 V DC
0.5 A 125 V DC
30 V DC
Number of operations
3
1
A
Min. 200 × 10
ope.
2 Form C
2 Form D
Standard contact
M.B.B. contact
3
Min. 100 × 10
ope.
3
1
A
Min. 100 × 10
ope.
Panasonic Industry Co., Ltd. Electromechanical Control Business Division
industrial.panasonic.com/ac/e/
Panasonic Industry Co., Ltd. 2023
ASCTB14E 202301
ー 5 ー
Signal Relays ( 2 A or less ) TQ RELAYS
SURFACE-MOUNT TERMINAL RATING
■ Coil data
• Operating
characteristics such as ” Operate voltage ” and ” Release voltage ” are influenced by mounting conditions or
ambient temperature, etc.
Therefore, please use the relay within ±5 % of rated coil voltage.
• “
Initial ” means the condition of products at the time of delivery.
● Single side stable
Rated operating
current
( ±10 %, at 20 ℃ )
Max. allowable
Rated coil
voltage
Operate voltage*
( at 20 ℃ )
Release voltage*
( at 20 ℃ )
Coil resistance
( ±10 %, at 20 ℃ )
Rated operating
power
voltage
( at 20 ℃ )
1.5 V DC
93.8 mA
46.7 mA
31 mA
28.1 mA
23.3 mA
15.5 mA
11.7 mA
8.3 mA
16
64.3 Ω
145
178
257
579
1,028
2,880
Ω
3
V DC
4.5 V DC
Ω
Ω
Ω
Ω
Ω
Ω
5
6
9
V DC
V DC
V DC
140 mW
150 % V of
rated coil voltage
Max. 75 % V of
rated coil voltage
( Initial )
Min. 10 % V of
rated coil voltage
( Initial )
12 V
DC
24 V
DC
200 mW
300 mW
120 % V of
rated coil voltage
48 V
DC
6.3 mA
7,680
Ω
* square, pulse drive ( JIS C 5442 )
● 1 coil latching
Rated operating
current
( ±10 %, at 20 ℃ )
Max. allowable
voltage
( at 20 ℃ )
Rated coil
voltage
Set voltage*
( at 20 ℃ )
Reset voltage*
( at 20 ℃ )
Coil resistance
( ±10 %, at 20 ℃ )
Rated operating
power
1.5 V DC
46.9 mA
23.3 mA
15.6 mA
14 mA
11.7 mA
7.8 mA
32
128.6 Ω
289.3 Ω
357
514
1,157
2,057
5,760
Ω
3
V DC
4.5 V DC
Max. 75 % V of
Max. 75 % V of
5
6
9
V DC
V DC
V DC
Ω
Ω
Ω
Ω
Ω
70 mW
150 % V of
rated coil voltage
rated coil voltage
rated coil voltage
( Initial )
( Initial )
12 V
DC
24 V
DC
5.8 mA
4.2 mA
100 mW
* square, pulse drive ( JIS C 5442 )
Note) Please inquire with one of our sales representatives if you require a relay with an unlisted voltage.
● 2 coil latching
Rated operating
Coil resistance
Rated operating
power
Max. allowable
voltage
current
Rated coil
voltage
Set voltage*
( at 20 ℃ )
Reset voltage*
( at 20 ℃ )
( ±10 %, at 20 ℃ )
( ±10 %, at 20 ℃ )
( at 20 ℃ )
Set coil
93.8 mA
46.7 mA
31 mA
28.1 mA
23.3 mA
15.5 mA
11.7 mA
8.3 mA
Reset coil
93.8 mA
46.7 mA
31 mA
28.1 mA
23.3 mA
15.5 mA
11.7 mA
8.3 mA
Set coil
Reset coil
16
64.3 Ω
Set coil
Reset coil
1.5 V DC
16
Ω
Ω
3
V DC
64.3 Ω
4.5 V DC
145
178
257
579
1,028
2,880
Ω
Ω
Ω
Ω
Ω
Ω
145
178
257
579
1,028
2,880
Ω
Ω
Ω
Ω
Ω
Ω
Max. 75 % V
of rated coil
voltage
Max. 75 % V
of rated coil
voltage
150 % V of
rated coil
voltage
5
6
9
V DC
V DC
V DC
140 mW
140 mW
200 mW
200 mW
( Initial )
( Initial )
12 V
DC
24 V
DC
* square, pulse drive ( JIS C 5442 )
Panasonic Industry Co., Ltd. Electromechanical Control Business Division
industrial.panasonic.com/ac/e/
Panasonic Industry Co., Ltd. 2023
ASCTB14E 202301
ー 6 ー
Signal Relays ( 2 A or less ) TQ RELAYS
■ Specifications
Item
Specifications
Contact arrangement
2 Form C
Contact resistance
( Initial )
Contact material
Max. 75 mΩ ( by voltage drop 6 V DC 1 A )
AgNi + Au clad
Contact rating
( resistive )
Max. switching power
( resistive )
2 A 30 V DC, 0.5 A 125 V AC
Contact data
60 W ( DC ), 62.5 VA ( AC )
Max. switching voltage
Max. switching current
Min. switching load
220 V DC, 125 V AC
2 A ( DC ), 2 A ( AC )
10 µA 10 mV DC
1
( reference value )*
Insulation resistance
( Initial )
Min. 1,000 MΩ ( at 500 V DC, Measured portion is the same as the case of dielectric strength. )
1,000 Vrms 1 min ( detection current: 10 mA )
Between open contacts
Dielectric
strength
( Initial )
Between contact and coil
1,500 Vrms 1 min ( detection current: 10 mA )
Between contact sets
1,500 Vrms 1 min ( detection current: 10 mA )
Surge
Between open contacts
1,500 V 10 × 160 µs
withstand
voltage
( Initial )
Between contact and coil
2,500 V 2 × 10 µs
Max. 4 ms at rated coil voltage ( at 20 ℃ , without bounce )
Operate [ Set ] time
Release [ Reset ] time
Time
[ Max. 4 ms ( at 20 ℃, without bounce ) ]
characteristics
( Initial )
Max. 4 ms at rated coil voltage ( at 20 ℃ , without bounce, without diode )
[ Max. 4 ms ( at 20 ℃, without bounce ) ]
2
Functional
Destructive
Functional
Destructive
Mechanical life
750 m/s
( half-sine shock pulse: 6 ms, detection time: 10 µs )
Shock
resistance
2
1,000 m/s
( half-sine shock pulse: 6 ms )
10 to 55 Hz ( at double amplitude of: 3 mm, detection time: 10 µs )
10 to 55 Hz ( at double amplitude of: 5 mm )
Vibration
resistance
6
Expected life
Conditions
Unit weight
Min. 100 × 10
ope. ( Switching frequency: at 180 times/min )
Ambient temperature: -40 to +85 ℃ ( 70 ℃ over: Max. 1 A )
Conditions for usage,
transport and storage*
( Allowable temperature is from -40 to +70 ℃ at our standard packing condition. )
2
Humidity: 5 to 85 % RH ( Avoid icing and condensation )
Approx. 2 g
Note) For AC load, please inquire our sales representative for details.
*1: This value is a rough indication of the lower limit at which switching is possible at micro load level.
This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load.
TX/TX-S/TX-D relay AgPd contact type are available for low level load analog circuit ( 10 V DC, 10 mA max. level ).
*2: For ambient temperature, please refer to the ” GUIDELINES FOR RELAY USAGE “.
■ Electrical life
Conditions: resistive load, switching frequency at 20 times/minute
Type
Switching capacity
Number of operations
3
1
2
A
A
30 V DC
30 V DC
Min. 200 × 10
ope.
3
2 Form C
Min. 100 × 10
ope.
3
0.5 A 125 V AC
Min. 100 × 10
ope.
Panasonic Industry Co., Ltd. Electromechanical Control Business Division
industrial.panasonic.com/ac/e/
Panasonic Industry Co., Ltd. 2023
ASCTB14E 202301
ー 7 ー
Signal Relays ( 2 A or less ) TQ RELAYS
PC BOARD TERMINAL REFERENCE DATA
1. Max. switching capacity
2. Switching life curve
100
1
AC loa
d
(
co
s
φ
=1
)
0.5
0.4
30V DC
resistive load
125V AC
resistive load
10
0.3
DC loa
d
(
co
s
φ
=1
)
0.2
0
0
0
30
100
Contact voltage, V
200
0
0.5
1
Switching capacity, A
3. Coil temperature rise value
4. Ambient temperature characteristics
5. Mechanical life
Tested sample
:
TQ2-12V
Tested sample
:
TQ2-12V, 5 pcs.
Tested sample
:
TQ2-12V, 10 pcs.
Measured portion
:
Inside the coil
Ambient temperature
:
30
°
C
100
90
40
70
30
20
10
Release
60
voltage Ave.
80
Operate voltage
1A
50
70
60
50
40
Max.
Min.
24V DC
Ave.
1A
0A
40
30
20
-40 -20
0
20 40
60 80
Operate
voltage
Ambient
temperature,
°
C
-10
Release voltage
30
Max.
Min.
-20
-30
-40
20
3
~
12V DC
10
10
0
0
0
10
100
1,000
10,000
0
100 110 120 130 140 150
Coil applied voltage,
%
V
No. of operations
,
×
10
4
6-1. Electrical life test ( 1 A 30 V DC resistive load )
ested sample
:
TQ2-12V, 6 pcs.
Change of operate and release voltage
Change of contact resistance
100
Condition
:
1 A 30 V DC resistive load, 20 cpm
100
90
90
80
70
60
50
40
30
20
10
0
Operate voltage
Release voltage
80
70
60
50
40
30
20
10
0
Max.
Min.
Max.
Min.
Max.
Min.
0
5
10
15
20
0
5
10
15
20
No. of operations
,
×
10
4
No. of operations
,
×
10
4
6-2. Electrical life test ( 0.5 A 125 V AC resistive load )
Tested sample
:
TQ2-12V, 6 pcs.
Change of operate and release voltage
Change of contact resistance
100
Condition
:
0.5 A 125 V AC resistive load, 20 cpm
100
90
80
90
80
70
60
50
40
30
20
10
0
Operate voltage
Max.
Min.
70
60
50
40
30
20
10
0
Max.
Min.
Release voltage
Max.
Min.
0
5
10
0
5
10
No. of operations
,
×
10
4
No. of operations
,
×
10
4
Panasonic Industry Co., Ltd. Electromechanical Control Business Division
industrial.panasonic.com/ac/e/
Panasonic Industry Co., Ltd. 2023
ASCTB14E 202301
ー 8 ー
Signal Relays ( 2 A or less ) TQ RELAYS
6-3. Electrical life test ( 0.1 A 53 V DC resistive load )
Change of operate and release voltage
Change of contact resistance
100
100
90
90
80
70
60
50
40
30
20
10
80
Operate voltage
Max.
Min.
70
60
50
40
Max.
Min.
30
Release voltage
20
Max.
Min.
10
0
0
0
500
1,000
No. of operations
,
×
10
4
1,500
2,000
0
500
1,000
1,500
2,000
No. of operations
,
×
10
4
7. Functional shock ( Single side stable )
Tested sample
:
TQ2-12V, 6 pcs.
8-1. Influence of proximity mounting
8-2. Influence of proximity mounting
20
20
m/s
2
]
Deenergized condition
Energized condition
[
Y
ON ON
ON
980
10
10
ℓ
ℓ
ℓ
0
0
ℓ
X
Operate voltage
Z
Operate voltage
ON
ON
-10
-10
ON
-20
20
10
20
20
10
–
OFF OFF
OFF
ℓ
ℓ
X’
Z
’
0
ℓ
ℓ
0
Z
X
X’
Release voltage
OFF
Z
Y
’
OFF
Release voltage
-10
-20
-10
-20
Y
’
Y
’
OFF
0
5
0
5
nter-relay distance
ℓ
, mm
nter-relay distance
ℓ
, mm
9-1. High frequency characteristics
( Isolation )
9-2. High frequency characteristics
( Insertion loss )
10. Contact reliability
( 1 mA 5 V DC resistive load )
Tested sample
:
TQ2-12V
Condition
:
Detection level 10
99.9
99
95
70
50
30
100
50
0
1
10
5
0.8
2
0.6
0.4
0.2
m=2.15
1
μ
=2.
7
×
10
7
95% reliability limit =
7.
6
×
10
6
0.5
0.2
0.1
(
Weibull probability paper
)
0
0
10
100
1,000
0
10
100
1,000
1
10
100
No. of operations
,
×
10
6
Frequency, MHz
Frequency, MHz
11. Distribution of M.B.B. time
Tested sample
:
TQ2-2M-5V, 85 pcs.
60
60
50
40
30
20
10
0
Terminal No.2-3-4 ON
Terminal No.2-3-4 ON
Ave.
:
105.6
μ
s
Ave.
:
71.6
μ
s
50
40
30
20
10
0
n-1
n-1
3
σ
:
163.8
μ
s
3
σ
:
127.1
μ
s
Min.
:
23
μ
s
Max
.
:
243
μ
s
Min.
:
17
μ
s
Max
.
:
187
μ
s
41
31
35
27
Terminal No.7-8-9 ON
Terminal No.7-8-9 ON
Ave.
:
115.6
μ
s
Ave.
:
80.7
μ
s
30
19
n-1
n-1
3
σ
:
167.3
μ
s
3
σ
:
156.7
μ
s
26
21
Min.
:
35
μ
s
Max
.
:
254
μ
s
Min.
:
29
μ
s
Max
.
:
298
μ
s
19
15
17
11
12
10
7
6
4
2
2
1
4
10
50 100
150 200 250
30
0
μ
s min.
10
50 100
150 200 250
30
0
μ
s min.
50 100
150 200 250 300
35
0
μ
s max.
50 100
150 200 250 300
35
0
μ
s max.
Panasonic Industry Co., Ltd. Electromechanical Control Business Division
industrial.panasonic.com/ac/e/
Panasonic Industry Co., Ltd. 2023
ASCTB14E 202301
ー 9 ー
Signal Relays ( 2 A or less ) TQ RELAYS
SURFACE-MOUNT TERMINAL REFERENCE DATA
1. Max. switching capacity
2. Switching life curve
3
2
100
50
DC resistive load
1
30
20
0.5
0.4
AC resistive load
0.3
10
0.2
30V DC
125V AC
resistive load
resistive load
0
0
0
20 30
50
100
200 300
0
1
2
Switching capacity, A
Contact voltage, V
5. Mechanical life
3. Coil temperature characteristics
4. Ambient temperature characteristics
( mounting by IRS method )
Tested sample
:
TQ2SA-12V, 10 pcs.
Tested sample
:
TQ2SA-12V, 6 pcs.
Point measured
:
Inside the coil
Ambient temperature
:
25
°
C
Tested sample
:
TQ2SA-12V, 5 pcs.
100
90
50
40
30
70
2A
0A
60
50
40
30
20
10
0
48V DC type
80
Ave.
Operate voltage
70
20
Max.
Min.
Ave.
10
60
50
40
2A
0A
-40 -20
0
20 40
60 80
Ambient
-10
Operate
voltage
temperature,
°
C
Release voltage
-20
-30
-40
-50
30
Release
voltage
Max.
Min.
20
12V DC type
10
0
10
100
1,000 10,000
0
100 110 120 130 140 150
%
V
IRS
1
Coil applied voltage,
No. of operations
,
×
10
4
6-1. Electrical life test ( 2 A 30 V DC resistive load )
Tested sample
:
TQ2SA-12V, 6 pcs.
Operating speed
:
20 cpm
Change of operate and release voltage
Change of contact resistance
(
mounting by IRS method
)
(
mounting by IRS method
)
100
90
100
90
80
70
60
50
40
30
20
10
0
80
Operate voltage
Release voltage
70
60
50
40
30
20
10
0
Max.
Min.
Max.
Min.
Max.
Min.
IRS
1
2
3
4
5
6
7
8
9
10
IRS
1
2
3
4
5
6
7
8
9 10
No. of operations
,
×
10
4
No. of operations
,
×
10
4
Panasonic Industry Co., Ltd. Electromechanical Control Business Division
Panasonic Industry Co., Ltd. 2023
ASCTB14E 202301
ー 10 ー
industrial.panasonic.com/ac/e/
Signal Relays ( 2 A or less ) TQ RELAYS
6-2. Electrical life test ( 0.5 A 125 V AC Resistive load )
Tested sample
:
TQ2SA-12V, 6 pcs
Operating speed
:
20 cpm
Change of operate and release voltage
(
mounting by IRS method
)
Change of contact resistance
(
mounting by IRS method
)
100
90
100
90
80
70
60
50
40
30
20
10
0
80
Operate voltage
Release voltage
70
60
50
40
30
20
10
0
Max.
Min.
Max.
Min.
Max.
Min.
IRS
1
2
3
4
5
6
7
8
9
10
IRS
1
2
3
4
5
6
7
8
9 10
No. of operations
,
×
10
4
No. of operations
,
×
10
4
7. Operate and release time
8. Functional shock
9-1. Influence of proximity mounting
( without diode )
Tested sample
:
TQ2SA-12V, 6 pcs.
(Single side stable)
Tested sample
:
TQ2SA-12V, 6 pcs
Tested sample
:
TQ2SA-12V, 5 pcs.
5
20
[
m/s
2
]
Operate time
Release time
Deenergized
condition
Energized
condition
Y
ON ON
1
,
000
10
4
0
ℓ
ℓ
X
Z
Operate voltage
Release voltage
ON
Max.
-10
3
2
1
0
Min.
-20
20
OFF OFF
10
X’
Z
’
Z
X
ℓ
ℓ
0
Max.
Min.
X’
Z
Y
’
OFF
-10
-20
Y
’
Y
’
0
1
2
3
4
5
6
0 70
80
90
100 110 120
Inter-relay distance,
ℓ
mm
Coil applied voltage, %V
9-2. Influence of proximity mounting
10-1. High frequency characteristics
( Isolation )
Tested sample
:
ATQ209SA, 1 pcs.
(
Isolation
)
10-2. High frequency characteristics
( Insertion loss )
Tested sample
:
ATQ209SA, 1 pcs.
(
Insertion loss
)
Tested sample
:
TQ2SA-12V, 6 pcs.
20
ON
10
ℓ
0
ℓ
Operate voltage
100
50
0
ON
ON
-10
1
-20
20
10
0.8
OFF
ℓ
0.6
0.4
0.2
0
ℓ
Release voltage
OFF
-10
OFF
Inter-relay distance,
ℓ
mm
-20
0
0
10
100
Frequency, MHz
1,000
0
10
100
Frequency, MHz
1,000
0
1
2
3
4
5
6
Panasonic Industry Co., Ltd. Electromechanical Control Business Division
Panasonic Industry Co., Ltd. 2023
ASCTB14E 202301
ー 11 ー
industrial.panasonic.com/ac/e/
Signal Relays ( 2 A or less ) TQ RELAYS
DIMENSIONS ( Unit: mm )
CAD
The CAD data of the products with a ” CAD ” mark can be downloaded from our Website.
■ PC board terminal ( standard/self-clinching terminal )
External dimensions
PC board terminal
( standard )
Recommended PC board pattern
( BOTTOM VIEW )
Schematic
CAD
( BOTTOM VIEW )
Single side stable
( De-energize )
10.16
2.54
1
2
3
4
5
+
-
10
9
8
7
6
10 –
φ
1
.0
14
9
Direction indication
Tolerance
:±
0.1
1 coil latching
( Reset )
1
2
3
4
5
6
-
2.54
0.5
0.25
7.62
General tolerance
:±
0.3
+
10
9
8
7
Direction indication
PC board terminal
( self-clinching terminal )
2 coil latching
( Reset )
1
2
3
4
5
+
-
+
-
10
9
8
7
6
14
9
Direction indication
2.54
0.5
0.25
7.62
General tolerance
:±
0.3
Panasonic Industry Co., Ltd. Electromechanical Control Business Division
Panasonic Industry Co., Ltd. 2023
ASCTB14E 202301
ー 12 ー
industrial.panasonic.com/ac/e/
Signal Relays ( 2 A or less ) TQ RELAYS
■ Surface-mount terminal
Schematic
( TOP VIEW )
CAD
Recommended PC board pattern
( TOP VIEW )
Type
External dimensions
Single side stable
( De-energize )
10
9
8
7
6
-
1
2.54
14
+
1
2
3
4
5
SA
Direction indication
Tolerance
: ±
0.1
2.54
0.5
7.62
11.5
±
0.5
1 coil latching
( Reset )
General tolerance
: ±
0.3
10
9
8
7
6
5
+
-
1
2
3
4
1
2.54
Direction indication
14
SL
2 coil latching
( Reset )
Tolerance
: ±
0.1
2.54
0.5
7.62
11.5
±
0.5
10
9
8
7
6
+
-
General tolerance
: ±
0.3
+
-
1
2
3
4
5
Direction indication
1
2.54
14
SS
Tolerance
: ±
0.1
7.62
2.54
0.5
9.3
±
0.5
General tolerance
: ±
0.3
Panasonic Industry Co., Ltd. Electromechanical Control Business Division
Panasonic Industry Co., Ltd. 2023
ASCTB14E 202301
ー 13 ー
industrial.panasonic.com/ac/e/
Signal Relays ( 2 A or less ) TQ RELAYS
PACKING STYLE ( Unit: mm )
■ Tube packing
1) The
relay is packing in a tube with
the relay orientation
mark on the left side,as shown in the figure below.
Be sure to
maintain relays in the correct orientation
when mounting on PC boards.
Orientatio
n
(
indicates PIN No.1
)
stripe
2)
Conditions for operation, transport and storage: -40 to 60 ℃.
Stopp
e
(
r gray
)
Stopp
e
(
r green
)
■ Taping packaging
1) Tape dimensions
SA Type
2) Dimensions of plastic reel
φ
21
±
0.8
+
0.1
Relay polarity bar
φ
1.5
(
Z type
)
2
4
φ
2
ꢀ
0
0.4
2
±
0.5
12.3
16
6.3
±
0.2
TQ-SMD
relays
Tape coming out direction
Tolerance
: ±
0.1
φ
13
±
0.2
24.4
+
2
0
2
±
0.2
SL Type
+
0.1
Relay polarity bar
φ
1.5
ꢀ
0
φ
2
2
4
0.4
3)
Conditions for operation, transport and storage: ‒40 to 70 ℃.
(
Z type
)
12.3
16
7.8
±
0.2
TQ-SMD
relays
Tape coming out direction
Tolerance
:
±
0.1
SS Type
+
0.1
φ
1.5
Relay polarity bar
ꢀ
0
φ
2
0.4
2
4
(
Z type
)
16
10.1
7.8
±
0.2
TQ-SMD
relays
Tape coming out direction
Tolerance
:
±
0.1
Panasonic Industry Co., Ltd. Electromechanical Control Business Division
Panasonic Industry Co., Ltd. 2023
ASCTB14E 202301
ー 14 ー
industrial.panasonic.com/ac/e/
Signal Relays ( 2 A or less ) TQ RELAYS
EXAMPLE OF RECOMMENDED SOLDERING CONDITIONS
■ For cautions for use, please read ” Relay Soldering and Cleaning Guidelines ” and ” SMT Soldering
Guidelines “.
■ PC board terminal
In case of hand soldering, the following conditions should be observed.
The effect on the relay depends on the PC board used. Please verify the actual PC board to be used.
● Automatic soldering ( Flow )
● Hand soldering
Recommended
Temperature
conditions
Measurement
location
Recommended
conditions
Measurement
location
Time
Temperature
Time
Within
Solder surface
terminal
Solder
temperature
Within
3 seconds
Tip
Preheating
Soldering
Max. 120 ℃
260 ℃ ±5 ℃
Soldering
Max. 350 ℃
120 seconds
temperature
Within
6 seconds
■ Surface-mount terminal
In case of automatic soldering ( reflow ), the following conditions should be observed.
● Mounting cautions
●
IRS ( infrared reflow soldering method ) heating conditions
Cautions to observe when mounting temperature
increases in the relay are greatly dependent on the way
different parts are located a PC board and the heating
method of the reflow device. Therefore, please conduct
testing on the actual device beforehand after making sure
the parts soldered on the relay terminals and the top of
the relay case are within the temperature conditions.
Recommend conditions
Number of reflow
1 time
Measuring position
Surface of PC board where relay is mounted.
4
t
t
t
t
t
1
2
3
4
=60s to 120s
T
3
1
=within 20s
T
2
=within 30s
T
=within 10
s
(
245 to 250
°
C
)
T
T
T
1
=150 to 180
°
C
=230
°
C and higher
=250
°
C max
2
3
1
2
3
t
t
t
Measuring position of temperature profile
Note
:
7KHꢀVROGHULQJꢀWHPSHUDWXUHꢀSURŏOHꢀ
Note
indicates the pad temperature. In
some cases, the ambient
temperature may be greatly
LQFUHDVHGꢁꢀ&KHFNꢀIRUꢀWKHꢀVSHFLŏFꢀ
mounting condition.
■ Other things to observe
• Exceeding
the stipulated conditions when soldering may
affect coaxial switch performance. Be sure to consult us
beforehand.
• Creep-up,
wettability and solder strength will differ
depending on changes in the mounting conditions and
type of solder. Please evaluate based on actual production
conditions.
• Only
apply coating after the relay has returned to room
temperature.
• Since
thermal stress on a relay will depend on the PC
board and process conditions, please be sure to test using
the actual PC board.
Panasonic Industry Co., Ltd. Electromechanical Control Business Division
Panasonic Industry Co., Ltd. 2023
ASCTB14E 202301
ー 15 ー
industrial.panasonic.com/ac/e/
Signal Relays ( 2 A or less ) TQ RELAYS
SAFETY STANDARDS
Each standard may be updated at any time, so please check our Website for the latest information.
■ UL/C-UL ( Approved )
● PC board terminal
■ CSA ( Approved )
CSA standard approved by C-UL.
Ambient
File No.
Contact rating
Operations
temperature
3
1
A
30 V DC Resistive
0.5 A 125 V AC General use
100 × 10
0.3 A 110 V DC Resistive
100 × 10
100 × 10
40 ℃
40 ℃
40 ℃
3
3
E43149
● Surface-mount terminal
Ambient
File No.
Contact rating
Operations
temperature
3
2
A
30 V DC Resistive
0.5 A 125 V AC General use
100 × 10
0.3 A 110 V DC Resistive
100 × 10
100 × 10
40 ℃
40 ℃
40 ℃
3
3
E43149
GUIDELINES FOR USAGE
■ For cautions for use, please read ” GUIDELINES FOR SIGNAL RELAYS USAGE ” and ” GUIDELINES FOR
RELAY USAGE “.
■ Cautions for usage of TQ relay
● Latching
● Precautions for usage of automatic insertion machine
Set the chucking pressure of the pick-up mechanism
by the automatic mounting machine with the pressure
shown in table 1 to maintain the internal function of the
relay.
• Use latching when conditions involve continuous
carrying current.
• Regarding the set and reset pulse time, for the purpose
of reliable operation under ambient temperature
fluctuations and different operating conditions, we
recommend setting the coil applied set and reset pulse
time to 10 ms or more at the rated coil voltage.
• The relay is shipped in the reset position. But jolts
during transport or impacts during installation can
change the reset position. It is, therefore, advisable to
build a circuit in which the relay can be initialized ( set
and reset ) just after turning on the power.
A
D
E
C
B
Please chuck the
ꢀꢀ
portion.
Avoid chucking the center of the
relay. In addition, excessive
chucking pressure to the pinpoint of
the relay should be also avoided.
● External magnetic field
Since TQ relays are highly sensitive polarized relays,
their characteristics will be affected by a strong external
magnetic field. Avoid using the relay under that condition.
Table 1: Chucking pressure
A, B and D direction
Max. 9.8 N ( 1 kgf )
Max. 4.9 N ( 500 gf )
( Surface-mount terminal: Max. 9.8 N ( 1 kgf )
C and E direction
● M.B.B. contact
A small OFF time may be generated by the contact
bounce during contact switching. Check the actual circuit
carefully.
Min. 10
μ
s
50
0
Ω
5V DC
Measuring condition of M.B.B. time
Panasonic Industry Co., Ltd. Electromechanical Control Business Division
Panasonic Industry Co., Ltd. 2023
ASCTB14E 202301
ー 16 ー
industrial.panasonic.com/ac/e/
GUIDELINES FOR SIGNAL RELAYS USAGE
■ For cautions for use, please read ” GUIDELINES FOR RELAY USAGE “.
PRECAUTIONS FOR COIL INPUT
■ Long term current carrying
■
Coil connection
A circuit that will be carrying a current continuously for
long periods without relay switching operation. ( circuits for
emergency lamps, alarm devices and error inspection that,
for example, revert only during malfunction and output
warnings with form B contacts )
When connecting coils of polarized relays, please check coil
polarity ( +, - ) at the internal connection diagram
( Schematic ).
If any wrong connection is made, it may cause unexpected
malfunction, like abnormal heat, fire and so on, and circuit
do not work.
Avoid impressing voltages to the set coil and reset coil at the
same time.
Continuous,long-term current to the coil will facilitate
deterioration of coil insulation and characteristics due to
heating of the coil itself. For circuits such as these, please
use a magnetic-hold type latching relay. If you need to use
a single stable relay, use a sealed type relay that is not easily
affected by ambient conditions and make a failsafe circuit
design that considers the possibility of contact failure or
disconnection.
■
Maximum allowable voltage and temperature rise
Proper usage requires that the rated coil voltage be
impressed on the coil.
Note, however, that if a voltage greater than or equal to the
maximum continuous voltage is impressed on the coil, the
coil may burn or its layers short due to the temperature rise.
Furthermore, do not exceed the usable ambient temperature
range listed in the catalog.
■
DC Coil operating power
Steady state DC current should be applied to the coil.
The wave form should be rectangular. If it includes ripple,
the ripple factor should be less than 5 %. However,
please check with the actual circuit since the electrical
characteristics may vary.
● Operate voltage change due to coil temperature rise
( hot start )
The rated coil voltage should be applied to the coil and the
set/reset pulse time of latching type relay differs for each
relays, please refer to the relay’s individual specifications.
In DC relays, after continuous passage of current in the
coil, if the current is turned OFF, then immediately turned
ON again, due to the temperature rise in the coil, the
operate voltage will become somewhat higher. Also,
it will be the same as using it in a higher temperature
atmosphere.
The resistance/temperature relationship for copper wire is
about 0.4 % for 1 ℃, and with this ratio the coil resistance
increases.
That is, in order to operate of the relay, it is necessary
that the voltage be higher than the operate voltage and
the operate voltage rises in accordance with the increase
in the resistance value.
However, for some polarized relays, this rate of change is
considerably smaller.
Panasonic Industry Co., Ltd. Electromechanical Control Business Division
Panasonic Industry Co., Ltd. 2022
ASCTB414E 202210
ー 17 ー
industrial.panasonic.com/ac/e/
GUIDELINES FOR SIGNAL RELAYS USAGE
NOTES
■
Usage, Storage, and Transport Conditions
During usage, storage, or transportation, avoid locations
subject to direct sunlight and maintain normal temperature,
humidity, and pressure conditions.
The allowable specifications for environments suitable for
usage, storage, and transportation are given below.
1) Temperature:
● Condensation
Condensation occurs when the ambient temperature
drops suddenly from a high temperature and humidity,
or the relay and microwave device is suddenly transferred
from a low ambient temperature to a high temperature
and humidity.
The allowable temperature range differs for each relay,
so refer to the relay’s individual specifications.
In addition, when transporting or storing relays while
they are tube packaged, there are cases when the
temperature may differ from the allowable range.
In this situation, be sure to consult the individual
specifications.
Condensation causes the failures like insulation
deterioration, wire disconnection and rust etc.
Panasonic Industry Co., Ltd. does not guarantee the
failures caused by condensation.
The heat conduction by the equipment may accelerate
the cooling of device itself, and the condensation may
occur.
2) Humidity: 5 to 85% RH
Please conduct product evaluations in the worst condition
of the actual usage. ( Special attention should be paid
when high temperature heating parts are close to the
device. Also please consider the condensation may occur
inside of the device. )
The humidity range varies with the temperature.
Use within the range indicated in the graph.
( The allowable temperature depends on the relays. )
Humidity (% RH)
● Icing
Condensation or other moisture may freeze on relays
when the temperature become lower than 0 ℃.
This icing causes the sticking of movable portion, the
operation delay and the contact conduction failure etc.
Panasonic Industry Co., Ltd. does not guarantee the
failures caused by the icing.
The heat conduction by the equipment may accelerate
the cooling of relay itself and the icing may occur.
Please conduct product evaluations in the worst condition
of the actual usage.
85
Allowable range
Avoid icing
Avoid con-
when used at
temperatures
lower than 0
°
C
densation when
used at tem-
peratures higher
than 0
°
C
5
-40
0
85
Ambient temperature (℃)
3) Pressure: 86 to 106 kPa
● Low temperature and low humidity
The plastic becomes brittle if the switch is exposed to
a low temperature, low humidity environment for long
periods of time.
● High temperature and high humidity
Storage for extended periods of time ( including
transportation periods ) at high temperature or high
humidity levels or in atmospheres with organic gases
or sulfide gases may cause a sulfide film or oxide film
to form on the surfaces of the contacts and/or it may
interfere with the functions.
Check out the atmosphere in which the units are to be
stored and transported.
● Package
In terms of the packing format used, make every effort
to keep the effects of moisture, organic gases and sulfide
gases to the absolute minimum.
Panasonic Industry Co., Ltd. Electromechanical Control Business Division
Panasonic Industry Co., Ltd. 2022
ASCTB414E 202210
ー 18 ー
industrial.panasonic.com/ac/e/
GUIDELINES FOR SIGNAL RELAYS USAGE
● Storage requirements
Since the surface-mount terminal type is sensitive to
humidity it is packaged with tightly sealed anti-humidity
packaging. However, when storing, please be careful of
the following.
4 ) The following cautionary label is affixed to the anti-
humidity pack.
1) Please use promptly once the anti-humidity pack is
opened. ( within 72 hours, Max. 30 ℃ / 70% RH ).
If left with the pack open, the relay will absorb
moisture which will cause thermal stress when reflow
mounting and thus cause the case to expand. As a
result, the seal may break.
2) If relays will not be used within 72 hours, please store
relays in a humidity controlled desiccator or in an anti-
humidity bag to which silica gel has been added.
* If the relay is to be soldered after it has been exposed to excessive
humidity atmosphere, cracks and leaks can occur.
Be sure to mount the relay under the required mounting conditions.
3) When relays ( which is packaged with humidity
indicator and silica gel ) meeting one of below criteria,
please bake ( dry ) before use.
• When the storage conditions specified in 1) are
exceeded.
● Silicon
When a source of silicone substances ( silicone rubber,
silicone oil,silicone coating materials and silicone filling
materials etc. ) is used around the relay, the silicone gas
( low molecular siloxane etc. ) may be produced
This silicone gas may penetrate into the inside of the
relay. When the relay is kept and used in this condition,
silicone compound may adhere to the relay contacts
which may cause the contact failure.
• When humidity indicator is in Ⅲ or Ⅳ status according
to judgement standard.
<How to judge>
Please check humidity indicator color and decide if
baking is necessary or not.
Do not use any sources of silicone gas around the relay
( Including plastic seal types ).
●: indicate brown, ○: Other than brown ( blueish color )
Bake treatment
● NOx Generation
5%
10%
60%
When relay is used in an atmosphere high in humidity
to switch a load which easily produces an arc, the NOx
created by the arc and the water absorbed from outside
the relay combine to produce nitric acid.
This corrodes the internal metal parts and adversely
affects operation.
necessity judgment
No need to bake
No need to bake
Need to bake
Ⅰ
Ⅱ
Ⅲ
Ⅳ
●
○
○
○
●
●
○
○
●
●
●
○
Need to bake
Spot
Avoid use at an ambient humidity of 85 % RH or higher
( at 20 ℃ ).
If use at high humidity is unavoidable, please contact our
sales representative.
5%
10%
60%
Humidity indicator card
<Baking ( Drying ) conditions>
• With reel : 45 ℃, 96 hours or more.
• Without reel ( including relay only ): 60 ℃, 35 hours
or more.
Panasonic Industry Co., Ltd. Electromechanical Control Business Division
Panasonic Industry Co., Ltd. 2022
ASCTB414E 202210
ー 19 ー
industrial.panasonic.com/ac/e/
GUIDELINES FOR SIGNAL RELAYS USAGE
OTHERS
■ Cleaning
• Although
the environmentally sealed type relay (plastic
sealed type,etc. ) can be cleaned, avoid immersing
the relay into cold liquid ( such as cleaning solvent )
immediately after soldering.
• Cleaning
with the boiling method is recommended ( The
temperature of cleaning liquid should be 40℃ or lower ).
Avoid ultrasonic cleaning on relays.
Use of ultrasonic cleaning may cause breaks in the coil
or slight sticking of the contacts due to the ultrasonic
energy.
Doing so may deteriorate the sealing performance.
•
Surface-mount terminal type relay is sealed type and it
can be cleaned by immersion.
Use pure water or alcohol-based cleaning solvent.
Please refer to
“the latest product specifications”
when designing your product.
•Requests to customers:
Panasonic Industry Co., Ltd. Electromechanical Control Business Division
Panasonic Industry Co., Ltd. 2022
ASCTB414E 202210
ー 20 ー
industrial.panasonic.com/ac/e/
■
Global Sales Network Information: industrial.panasonic.com/ac/e/salesnetwork
Electromechanical Control Business Division
1006, Oaza Kadoma, Kadoma-shi, Osaka 571-8506, Japan
industrial.panasonic.com/ac/e/
Specifications are subject to change without notice.
2023.1
©Panasonic Industry Co., Ltd. 2023
モヴヤヵャヒフユチチチビパビピパヒ