PANASONIC-TX2-L-5V-1

Part #PANASONIC-TX2-L-5V-1
Download 
PANASONIC-TX2-L-5V-1
Signal Relays ( 2A or less )  
TX RELAYS  
Product Catalog  
2022.4  

Signal Relays (2A or less)  
REL
A
Y
S  
TX  
2,000 Vrms dielectric strength, 2 Form C and 2A relays  
FEATURES  
Protective construction
:
Sealed type  
2 types of terminal shapes:  
PC board terminal and Surface-mount terminal  
Ag+Au clad contact and AgPd contacts suitable for  
use in low level load analog circuits  
2,000 Vrms dielectric strength (Between contact and  
coil)  
7.4  
8.2  
15  
Compliant with Telcordia standard: Surge withstand  
voltage 2,500 V (between contact and coil)  
Confort to FCC Part68: Surge withstand voltage  
1,500 V (between open contacts)  
7.4  
8.4  
15  
TYPICAL APPLICATIONS  
Telecommunications and measurement equipment  
Medical and security equipment  
(
Unit
:
mm
)  
ORDERING INFORMATION (PART NO. : Ordering part number for Japanese market)  
ATX 2  
Surface-mount type  
Contact arrangement  
2
:
2 Form C  
Packing style*

3  

Nil  
:
Standard PC board terminal type  
Ni
l
:
T
ube
 
packing  
SA
:
SA type  
SS
:
SS type  
X
Z
: Tape
 
and reel (picked from 1/3/4/5-pin side)  
Terminal shape / Operating function  
0
:
Standard PC board terminal type or  
Surface-mount terminal  
: Tape
 
and reel packing (picked from the 8/9/10/12-pin side)  
W : Tape
 
and reel packing (picked from the 1/3/4/5-pin side)  
With humidity indicator and silica gel in moisture proof bag*

4  

Single side stable  
Contact material  
Y
: Tape
 
and reel packing (picked from the 8/9/10/12-pin side)  
With humidity indicator and silica gel in moisture proof bag*

4  

1
:
Standard PC board terminal type or  
Surface-mount terminal  
Nil
:
Standard conta
c
(
t Ag+Au
 
clad
)  
20
:
AgPd conta
c
(
t low
 
level load
)
;  
AgPd+Au cla
d
(
stationary
)
,  
AgP
d
(
movable
)  
1 coil latching  
2
:
Standard PC board terminal type or  
Surface-mount terminal  
2 coil latching (L2)*

5  

Rated coil voltage (DC)*

1,  

0
:
1.5
V
,
 
1
:
3
V
,
 
2
:
6
V
,
 
3
:
12
V
,
 
4
:
24
V
,  
5
:
48
V
,
 
6
:
4.5
V
,
 
7
:
9
V
,
 
9
:
5 V  
*
2
6
:
Standard PC board terminal type or  
Surface-mount terminal  
2 coil latching (LT)  
*1: 48
 
V coil type
:
Single side stable only.  
*2: In
 
case of 5 V transistor drive circuit, it is recommended to use 4.5 V type relay.  
*3: Th
e
“
W
”
an
d
“
Y
”
at the end of the part number only appears on the inner and outer packing.  
It does not appear on the relay itself.  
*4: Each
 
reel is packed with humidity indicators and silica gel in the moisuture proof pack.  
*5: Please
 
contact our sales representative for detailed specifications when using L2 of the operation function.  
Panasonic Industry Co., Ltd. Electromechanical Control Business Division  
Panasonic Industry Co., Ltd. 2022  
ASCTB18E 20220
4
 
ー 1 ー  
industrial.panasonic.com/ac/e/  

Signal Relays (2A or less) TX RELAYS  
ORDERING INFORMATION (TYPE NO. : Ordering part number for non Japanese market)  
TX 2  
Surface-mount type  
Nil
:
Standard PC board terminal type  
SA
:
SA type  
Contact material  
Packing style*

3  

Nil
:
Standard conta
c
(
t Ag+Au
 
clad
)
Ni
l
:
T
ube
 
packing  
1
:
AgPd conta
c
(
t low
 
level load
)
;  
AgPd+Au cla
d
(
stationary
)
,  
AgP
d
(
movable
)  
X
Z
: Tape
 
and reel (picked from 1/3/4/5-pin side)  
SS
:
SS type  
: Tape
 
and reel packing (picked from the 8/9/10/12-pin side)  
W : Tape
 
and reel packing (picked from the 1/3/4/5-pin side)  
With humidity indicator and silica gel in moisture proof bag*

4  

Contact arrangement  
2
:
2 Form C  
Rated coil voltage (DC)*

1,  

1.5, 3, 4.5, 5, 6, 9, 12, 24, 48V  
*
Y
: Tape
 
and reel packing (picked from the 8/9/10/12-pin side)  
With humidity indicator and silica gel in moisture proof bag*

4  

2
Operating function  
Nil : Single side stable  
L
: 1 coil latching  
L2 : 2 coil latching (SET = 1,6 Pin)*

5  

LT :
 
2 coil latching (SET = 1,12 Pin)  
*1: 48
 
V coil type
:
Single side stable only.  
*2: In
 
case of 5 V transistor drive circuit, it is recommended to use 4.5 V type relay.  
*3: Th
e
“
W
”
an
d
“
Y
”
at the end of the part number only appears on the inner and outer packing.  
It does not appear on the relay itself.  
*4: Each
 
reel is packed with humidity indicators and silica gel in the moisuture proof pack.  
*5: Please
 
contact our sales representative for detailed specifications when using L2 of the operation function.  
TYPES  
” Type No. ” is ordering part number for non Japanese market. ” Part No. ” is ordering part number for Japanese market.  
PC board terminal  
Tube packing  
Single side stable  
Type No.
 
Part No.  
2
coil latching (LT)  
Part No.  
Standard packing  
Contact  
arrangement  
Rated coil  
voltage  
Carton  
Outer  
Type No.  
(
1  
Tube packing)  
carton  
1
.
5
3
5
5
6
9
V DC  
V DC  
V DC  
V DC  
V DC  
V DC  
TX
2  
TX
2  
TX
2  
TX
2  
TX
2  
TX
2  
TX
2  
TX
2  
TX
2  
–
–
–
–
–
–
–
–
–
1
3
4
5
6
9
.
5
V
V
ATX
200  
ATX
201  
ATX
206  
ATX
209  
ATX
202  
ATX
207  
ATX
203  
ATX
204  
ATX
205  
TX
2  
TX
2  
TX
2  
TX
2  
TX
2  
TX
2  
TX
2  
TX
2  
–
-LT-  
-LT-  
-LT-  
-LT-  
-LT-  
-LT-  
1
3
4
5
6
9
.
5
V
ATX
260  
ATX
261  
ATX
266  
ATX
269  
ATX
262  
ATX
267  
ATX
263  
ATX
264  
–
V
V
4
.
.
5
.
5  
V
V
V
V
V
V
V
2
Form C  
40
pcs.  
1
,
000
pcs.  
12
V DC  
24
V DC  
48
V DC  
12  
24  
48  
V
-LT-
12  
-LT-
24  
V
V
V
V
Note: Please add “-1” to the end of the type number or “20” to the end of the part number for AgPd contacts (low level load).  
Surface-mount terminal  
SA Type: Tube packing  
Single side stable  
Type No.
 
Part No.  
2
coil latching (LT)  
Standard packing  
Contact  
arrangement  
Rated coil  
voltage  
Carton  
Outer  
Type No.  
Part No.  
(
1  
Tube packing)  
carton  
1
.
5
3
5
5
6
9
V DC  
V DC  
V DC  
V DC  
V DC  
V DC  
TX  
TX  
TX  
TX  
TX  
TX  
TX  
TX  
TX  
2
2
2
2
2
2
2
2
2
SA-  
SA-  
SA-  
SA-  
SA-  
SA-  
1
3
4
5
6
9
.
5
V
ATX
200
SA  
ATX
201
SA  
ATX
206
SA  
ATX
209
SA  
ATX
202
SA  
ATX
207
SA  
ATX
203
SA  
ATX
204
SA  
ATX
205
SA  
TX
2  
TX
2  
TX
2  
TX
2  
TX
2  
TX
2  
TX
2  
TX
2  
–
SA-LT-  
SA-LT-  
SA-LT-  
SA-LT-  
SA-LT-  
SA-LT-  
1
3
4
5
6
9
.
5
V
V
ATX
260
SA  
ATX
261
SA  
ATX
266
SA  
ATX
269
SA  
ATX
262
SA  
ATX
267
SA  
ATX
263
SA  
ATX
264
SA  
–
V
V
4
.
.
5
V
.
5  
V
V
V
V
V
V
2
Form C  
40
pcs.  
1
,
000
pcs.  
12
V DC  
24
V DC  
48
V DC  
SA-
12  
SA-
24  
SA-
48  
V
SA-LT-
12  
SA-LT-
24  
V
V
V
V
Note : Please add “-1” to the end of the type number or “20” to be added in front of “surface-mount type” in part number for AgPd contacts (low level load).  
Panasonic Industry Co., Ltd. Electromechanical Control Business Division  
Panasonic Industry Co., Ltd. 2022  
ASCTB18E 20220
4  
ー 2 ー  
industrial.panasonic.com/ac/e/  

Signal Relays (2A or less) TX RELAYS  
SA Type:
T
a
pe and reel packing: Z  
Single side stable  
2
coil latching (LT)  
Part No.  
Standard packing  
Contact  
arrangement  
Rated coil  
voltage  
Carton  
-Reel)  
Outer  
carton  
Type No.
 
Part No.  
Type No.  
(
1  
1
.
5
3
5
5
6
9
V DC  
V DC  
V DC  
V DC  
V DC  
V DC  
TX
2  
TX
2  
TX
2  
TX
2  
TX
2  
TX
2  
TX
2  
TX
2  
TX
2  
SA-  
SA-  
SA-  
SA-  
SA-  
SA-  
1
3
4
5
6
9
.
5
V-Z  
V-Z  
V-Z  
ATX
200
SAZ  
ATX
201
SAZ  
ATX
206
SAZ  
ATX
209
SAZ  
ATX
202
SAZ  
ATX
207
SAZ  
ATX
203
SAZ  
ATX
204
SAZ  
ATX
205
SAZ  
TX  
TX  
TX  
TX  
TX  
TX  
TX  
TX  
–
2
2
2
2
2
2
2
2
SA-LT-  
SA-LT-  
SA-LT-  
SA-LT-  
SA-LT-  
SA-LT-  
1
3
4
5
6
9
.
5
V-Z  
V-Z  
V-Z  
ATX
260
SAZ  
ATX
261
SAZ  
ATX
266
SAZ  
ATX
269
SAZ  
ATX
262
SAZ  
ATX
267
SAZ  
ATX
263
SAZ  
ATX
264
SAZ  
–
4
.
.
5
.
5
V-Z  
V-Z  
V-Z  
V-Z  
V-Z  
V-Z  
2
Form C  
500
pcs.  
1
,
000
pcs.  
12
V DC  
24
V DC  
48
V DC  
SA-
12
V-Z  
SA-
24
V-Z  
SA-
48
V-Z  
SA-LT-
12
V-Z  
SA-LT-
24
V-Z  
Notes: 1. Please add “-1” to the end of the type number or “20” to be added in front of “surface-mount type” in part number for AgPd contacts (low level load).  
2. For X, W and Y tape and reel packing, please replace the “Z” at the end of the part number with “X”, “W” or “Y”.  
3. If you need the PC board terminal, 1 coil latching and 2 coil latching (L2) of surface-mount terminal, please inquire our sales office for details.  
RATING  
Coil data  
• Operating characteristics such as “Operate voltage” and “Release voltage” are influenced by mounting conditions or ambient  
temperature, etc.  
Therefore, please use the relay within ±5% of rated coil voltage.  
• “Initial” means the condition of products at the time of delivery.  
Single side stable  
Rated operating  
current  
(±
10
%, at
20
°C)  
Max. allowable  
Rated coil  
voltage  
Operate voltage*  
(at
20
°C)  
Release voltage*  
(at
20
°C)  
Coil resistance  
(±
10
%, at
20
°C)  
Rated operating power  
voltage  
(at
20
°C)  
1
4
.
5
3
5
5
6
9
V DC  
V DC  
V DC  
V DC  
V DC  
V DC  
93  
46  
.
.
8
7
mA  
mA  
16  
64  
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
.
3  
.
31
mA  
145  
178  
257  
579  
028  
28  
23  
15  
11  
5
.
.
.
.
.
1
3
5
7
8
mA  
mA  
mA  
mA  
mA  
150
% V of  
rated coil voltage  
140
mW  
Max.
75
% V of  
rated coil voltage  
(Initial)  
Min.
10
% V of  
rated coil voltage  
(Initial)  
12
V DC  
24
V DC  
1
,  
4
,  
114  
120
% V of  
rated coil voltage  
48
V DC  
5
.
6  
mA  
8
,
533  
Ω
270
mW  
*square, pulse drive  
2 coil latching  
Rated operating  
current  
(±
10
%, at
20
°C)  
Coil resistance  
(±
10
%, at
20
°C)  
Max. allowable  
voltage  
Rated operating power  
Rated coil  
voltage  
Set voltage*  
(at
20
°C)  
Reset voltage*  
(at
20
°C)  
(at
20
°C)  
Set coil  
Reset coil  
Set coil  
Reset coil  
Set coil  
Reset coil  
1
.
5
3
5
5
6
9
V DC  
V DC  
V DC  
V DC  
V DC  
V DC  
133  
66  
.
.
.
9
7
5
mA  
mA  
mA  
133  
66  
.
.
.
9
7
5
mA  
mA  
mA  
11  
45  
101  
.
2
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
11  
45  
101  
.
2
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
4
.
44  
44  
.
2
.
2
Max.
75
% V of  
rated coil voltage  
(Initial)  
Min.
10
% V of  
rated coil voltage  
(Initial)  
40
mA  
40
mA  
125  
180  
405  
720  
880  
125  
180  
405  
720  
880  
150
% V of  
rated coil voltage  
200
mW  
200
mW  
33  
22  
16  
8
.
.
.
.
3
2
7
3
mA  
mA  
mA  
mA  
33  
22  
16  
8
.
.
.
.
3
2
7
3
mA  
mA  
mA  
mA  
12
V DC  
24
V DC  
2
,
2
,  
*square, pulse drive  
Panasonic Industry Co., Ltd. Electromechanical Control Business Division  
Panasonic Industry Co., Ltd. 2022  
ASCTB18E 20220
4  
ー 3 ー  
industrial.panasonic.com/ac/e/  

Signal Relays (2A or less) TX RELAYS  
Specifications  
Specifications  
Item  
Standard contact  
AgPd contact (low level load)  
Contact arrangement  
2
Form C  
Contact resistance  
(initial)  
Max.
100
mΩ (by voltage drop  
6
V DC
1
A)  
Contact material  
Ag+Au clad  
AgPd+Au clad (stationary), AgPd (movable)  
30
V DC  
30
W (DC)  
Contact rating  
(resistive)  
2
A
30
V DC  
1
A  
Contact data  
Max. switching power  
(resistive)  
60
W (DC)  
Max. switching voltage
 
220
V DC  
Max. switching current  
2
A (DC)  
10
μA
10
mV DC  
Min.
000
MΩ (at
500
V DC, Measured portion is the same as the case of dielectric strength.)  
1
A (DC)  
Min. switching load  
(reference value)*

1  

Insulation resistance (initial)  
Between open contacts  
Between contact and  
strength (initial)
 
coil  
Between contact sets  
1
,  
1
,
000
Vrms for  
000
Vrms for  
000
Vrms for  
1
1
1
min (detection current:
10
mA)  
min (detection current:
10
mA)  
min (detection current:
10
mA)  
Dielectric  
2
,  
1
,
,
Between open contacts  
1
500  
V
10  
×
160
μs  
Surge  
withstand  
voltage (initial)  
Between contact and  
coil  
2
,  
500  
V
2
×
10
μs  
Max.  
[Max.  
4
4
ms at rated coil voltage (at
20
°C, without bounce)  
ms (at
20
°C, without bounce)]  
Operate (Set) time  
Time  
characteristics  
(initial)  
Max.  
[Max.  
4
4
ms at rated coil voltage (at
20
°C, without bounce, without diode)  
ms (at
20
°C, without bounce)]  
Release (Reset) time  
Functional  
750
m/s

2

(half-sine shock pulse:  
ms, detection time:
10
μs)  
000
m/s

2

(half-sine shock pulse:  
6
ms)  
6
Shock  
resistance  
Destructive  
Functional  
1
,  
10
to
55
Hz (at double amplitude of:  
10
to
55
Hz (at double amplitude of:  
3
.
3
mm, detection time:
10
μs)  
Vibration  
resistance  
Destructive  
Mechanical life  
5
mm)  
Expected life  
Conditions  
Unit weight  
Min.
100  
x
10

6

ope. (Switching frequency: at
180
times/min)  
to
24
V DC), –
40
to +
70
°C (
48
V DC), (Allowable temperature is from  
40
to +
70
°C at our standard packing condition.)  
Ambient temperature: –
40
to +
85
°C (
1
.
5  
–
Conditions for usage,  
transport and storage*

2  

Humidity:  
5
to
85
% RH (Avoid icing and condensation)  
Approx.  
2
g
Note: For AC load, please inquire our sales office for details.  
*1: This value is a rough indication of the lower limit at which switching is possible at micro load level.  
This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load.  
AgPd contact is recommended for low level load (Max. 10 V DC, 10 mA level).  
*2: For ambient temperature, please refer to the “GUIDELINES FOR RELAY USAGE”.  
Electrical life  
Conditions: resistance load, switching frequency at 20 times / minute.  
Type  
Switching capacity  
Number of operations  
1
2
A
A
30
V DC  
30
V DC  
Min.
500  
Min.
100  
x
x
10

3

ope.  
10

3

ope.  
2
Form C  
REFERENCE DATA  
1. Max. switching capacity  
2. Switching life curve  
3. Coil temperature rise value (Average)  
Tested sample
:
TX2-5
V
, 6
p
cs.  
Point measured
:
Inside the coil  
Ambient temperature
:
25
°
C, 85
°
C  
70  
+25
°
C  
3
2
+85
°
C  
60  
100  
50  
50  
1
DC resistive load  
40  
30  
20  
30V DC resistive load  
30  
20  
2A  
2A  
0A  
0.5  
0.4  
0.3  
0A  
10  
0
0.2  
10  
0
0
0
20 30  
50  
100  
200 300  
0
1
2
0
100 110 120 130 140 150  
Contact voltage, V  
Switching capacity, A  
Coil applied voltage,
%
V  
Panasonic Industry Co., Ltd. Electromechanical Control Business Division  
Panasonic Industry Co., Ltd. 2022  
ASCTB18E 20220
4  
ー 4 ー  
industrial.panasonic.com/ac/e/  

Signal Relays (2A or less) TX RELAYS  
4. Ambient temperature characteristics  
(Average)  
5. Mechanical life  
Tested sample
:
TX2-5
V
,
1
0 pcs.  
Operating speed
:
180 cpm  
Tested sample
:
TX2-5
V
, 5
p
cs.  
100  
90  
50  
40  
80  
30  
Ave.  
Ave.  
Operate voltage  
Max.  
Min.  
70  
60  
50  
40  
30  
20  
20  
10  
-60 -40 -20  
0
20 40
 
60 80
 
100  
Ambient  
-10  
Release  
voltage  
temperature,
°
C  
-20  
Release voltage  
100  
Operate  
voltage  
-30  
Max.  
Min.  
-40  
-50  
10  
0
0
10  
1,000  
10,000  
No. of operations
,
×
10

4  

6. Electrical life test (2 A 30 V DC resistive load)  
Tested sample
:
TX2-5
V
, 6
p
cs.  
Operating speed
:
20 cpm  
Change of operate and release voltage  
100  
Change of contact resistance  
100  
90  
90  
80  
70  
60  
50  
40  
30  
20  
10  
0
80  
Operate voltage  
Max.  
Min.  
70  
60  
50  
Max.  
Min.  
40  
Release voltage  
Max.  
Min.  
30  
20  
10  
0
0
1
2
3
4
5
6
7
8
9
10  
0
1
2
3
4
5
6
7
8
9
10  
No. of operations
,
×
10

4  

No. of operations
,
×
10

4  

7-1. Operate and release time  
7-2. Operate and release time  
8. Functional shock  
(without diode)  
(with diode)  
Tested sample
:
TX2-5
V
,
1
0 pcs.  
Tested sample
:
TX2-5
V
,
1
0 pcs.  
Tested sample
:
TX2-5
V
, 6
p
cs.  
5
5
m/s

2  

]
Deenergized condition  
Energized condition  
Operate time  
Release time  
Operate time  
Release time  
[
Y
1,000  
4
3
2
1
0
4
3
2
1
0
Max.  
Min.  
Max.  
Min.  
X
Z
Max.  
Min.  
X’

X  

Z
’
Max.  
Min.  
Z
X’  
Z
’
Y
’
Y
’
Y
0 70  
80  
90  
100 110 120  
0 70  
80  
90  
100 110 120  
Coil applied voltage, %V  
Coil applied voltag
e
(
, %V
)  
9-1. Influence of proximity mounting  
9-2. Influence of proximity mounting  
Tested sample
:
TX2-12
V
, 6
p
cs.  
Tested sample
:
TX2-12
V
, 6
p
cs.  
10  
10  
ON ON  
ON ON  
5
0
5
0
ℓ
ℓ
ℓ
ℓ
Operate voltage  
Operate voltage  
ON  
ON  
ON  
-5  
-10  
10  
-5  
–
10  
10  
5
OFF OFF  
OFF  
5
ℓ
ℓ
ℓ
ℓ
0
0
Release voltage  
Release voltage  
OFF  
OFF  
-5  
–
5
OFF  
-10  
-10  
0
2
4
6
8
10  
0
2
4
6
8
10  
Inter-relay distance
ℓ
, mm  
Inter-relay distance
ℓ
, mm  
Panasonic Industry Co., Ltd. Electromechanical Control Business Division  
Panasonic Industry Co., Ltd. 2022  
ASCTB18E 20220
4  
ー 5 ー  
industrial.panasonic.com/ac/e/  

Signal Relays (2A or less) TX RELAYS  
10-1. High frequency characteristics  
10-2. High frequency characteristics  
(Isolation)  
(Insertion loss)  
Tested sample
:
TX2-12
V
, 2
p
cs.  
Tested sample
:
TX2-12
V
, 2
p
cs.  
100  
50  
0
1
0.8  
0.6  
0.4  
0.2  
0
0
10  
100  
1,000  
0
10  
100  
1,000  
Frequency, MHz  
Frequency, MHz  
CAD  
The CAD data of the products with a “CAD” mark can be downloaded from our Website.  
DIMENSIONS  
Unit: mm  
PC board terminal  
Single side stable  
External dimensions  
Recommended PC board pattern  
(BOTTOM VIEW)  
Schematic  
CAD  
(BOTTOM VIEW)  
(De-energize)  
10.16  
2.54  
1
3
4
5
15  
+
-
12  
10  
9
8
8
‒
1 dia.  
Direction indication  
Tolerance
:±
0.1  
0.5  
1.15  
0.25  
5.08  
5.08  
2.54  
General tolerance
: ±
0.3  
2 coil latching  
External dimensions  
Recommended PC board pattern  
(BOTTOM VIEW)  
Schematic  
CAD  
(BOTTOM VIEW)  
(Reset)  
(Operation function LT)  
12.7  
2.54  
1
3
4
5
6
15  
+
+
-
-
12  
10  
9
8
7
10
‒
1 dia.  
Direction indication  
Tolerance
:±
0.1  
(Operation function L2)  
0.5  
1.15  
0.25  
5.08  
5.08  
2.54  
4
5
1
3
6
General tolerance
: ±
0.3  
+
+
-
-
10 9
 
8  
12  
7
Direction indication  
Note: If you need the recommended PC board pattern and schematic, please inquire our sales office for details.  
Panasonic Industry Co., Ltd. Electromechanical Control Business Division  
Panasonic Industry Co., Ltd. 2022  
ASCTB18E 20220
4  
ー 6 ー  
industrial.panasonic.com/ac/e/  

Signal Relays (2A or less) TX RELAYS  
Surface-mount terminal  
CAD  
Recommended  
Schematic  
Type  
External dimensions  
PC board pattern  
(TOP VIEW)  
(TOP VIEW)  
(De-energize)  
5.08  
1
2.54  
15  
12  
1
10  
3
9
4
8
5
-
+
Direction indication  
Tolerance
:±
0.1  
5.08  
9.4
±
0.5  
0.5  
1.15  
5.08  
2.54  
General tolerance
: ±
0.3  
(Reset)  
(Operation function LT)  
12  
10  
9
8
7
-
-
+
5.08  
1
2.54  
15  
+
1
3
4
5
6
Direction indication  
(Operation function L
2
)  
Tolerance
:±
0.1  
12 10
 
9  
8
7
-
-
5.08  
9.4
±
0.5  
0.5  
+
+
1.15  
5.08  
2.54  
1
6
5
3
4
General tolerance
: ±
0.3  
Direction indication  
Note: If you need the recommended PC board pattern and schematic, please inquire our sales office for details.  
PACKING STYLE  
Unit: mm  
Tube packing  
1. The relay is packing in a tube with
 
the relay orientation mark  
on the left side,as shown in the figure below.  
Be sure to
 
maintain relays in the correct orientation when  
mounting on PC boards.  
Orientatio
n
(
indicates PIN No.1
)
stripe  
2. Conditions for operation, transport and storage : –40 to 70°C.  
Stopp
e
(
r gray
)  
Stopp
e
(
r green
)  
Taping packaging  
1.
T
a
pe dimensions  
2. Dimensions of plastic reel  
SA Type  
21
±
0.8 dia.  
1.5

+

ꢀ

0

0

.1

dia.  
Relay polarity bar  
2
4
0.4  
(
Z type
)  
2
±
0.5  
16  
9.2
±
0.2  
TX relays  
Tape coming out direction  
13
±
0.2 dia.  
24.4

+ 2  

0
2
±
0.2  
3. Conditions for operation, transport and storage : –40 to 70°C.  
Panasonic Industry Co., Ltd. Electromechanical Control Business Division  
Panasonic Industry Co., Ltd. 2022  
ASCTB18E 20220
4  
ー 7 ー  
industrial.panasonic.com/ac/e/  

Signal Relays (2A or less) TX RELAYS  
EXAMPLE OF RECOMMENDED SOLDERING CONDITIONS  
For cautions for use, please read “Relay Soldering and Cleaning Guidelines” and “SMT Soldering Guidelines”.  
PC board terminal  
In case of hand soldering, the following conditions should be observed.  
The effect on the relay depends on the PC board used. Please verify the actual PC board to be used.  
Automatic soldering (Flow)  
Hand soldering  
Recommended  
T
e
mperature  
conditions  
Measurement  
location  
Recommended  
conditions  
Measurement  
location  
Time  
T
e
mperature  
Max.
350
°C  
Time  
Within
120  
seconds  
Solder surface  
terminal  
Within
3  
seconds  
Preheating  
Soldering  
Max.
120
°C  
260
°C ±
 
°C  
Soldering  
Tip temperature  
Within  
seconds  
6
Solder  
temperature  
5
Surface-mount terminal  
In case of automatic soldering (reflow), the following conditions should be observed.  
IRS (infrared reflow soldering method) heating conditions  
Mounting cautions  
Cautions to observe when mounting temperature increases  
in the relay are greatly dependent on the way different parts  
are located a PC board and the heating method of the reflow  
device. Therefore, please conduct testing on the actual  
device beforehand after making sure the parts soldered on  
the relay terminals and the top of the relay case are within the  
temperature conditions.  
Recommend conditions  
Number of reflow  
1
time  
Measuring position  
Surface of PC board where relay is mounted.  
4
t
t
t
t
t
1
2
3
4
=60s to 120s  
T
3
1
=within 20s  
T
2
=within 30s  
T
=within 10
s
(
245 to 250
°
C
)  
T
T
T
1
=150 to 180
°
C  
=230
°
C and higher  
=250
°
C max  
2
3
1
2
3
t
t
t
Measuring position of temperature profile  
Note
:
The soldering temperature profile  
indicates the pad temperature. In  
some cases, the ambient  
Note  
temperature may be greatly  
increased. Check for the specific  
mounting condition.  
Other things to observe  
• Exceeding the stipulated conditions when soldering may  
affect coaxial switch performance. Be sure to consult us  
beforehand.  
• Creep-up, wettability and solder strength will differ depending  
on changes in the mounting conditions and type of solder.  
Please evaluate based on actual production conditions.  
• Only apply coating after the relay has returned to room  
temperature.  
• Since thermal stress on a relay will depend on the PC board  
and process conditions, please be sure to test using the  
actual PC board.  
Each standard may be updated at any time, so please check our Website for the latest information.  
SAFETY STANDARDS  
UL/C-UL (Approved)  
CSA (Approved)  
Ambient  
temperature  
CSA standard approved by C-UL.  
File No.  
Contact rating  
Operations  
2
0
0
A
30
V DC Resistive  
100  
100  
100  
×
×
×
10

3  

10

3  

10

3  

40
°C  
40
°C  
40
°C  
E43149  
.
5  
A
A
125
V AC Resistive  
110
V DC Resistive  
.
3  
BSI (Approved)  
BSI standard approved by File No. VC659956  
(basic insulation).  
Panasonic Industry Co., Ltd. Electromechanical Control Business Division  
Panasonic Industry Co., Ltd. 2022  
ASCTB18E 20220
4  
ー 8 ー  
industrial.panasonic.com/ac/e/  

Signal Relays (2A or less) TX RELAYS  
GUIDELINES FOR USAGE  
For cautions for use, please read “GUIDELINES FOR SIGNAL REL
A
Y
S USAGE” and “GUIDELINES FOR REL
A
Y  
USAGE”.  
Cautions for usage of TX relay  
Latching  
Precautions for usage of automatic insertion machine  
Set the chucking pressure of the pick-up mechanism by the  
automatic mounting machine with the pressure shown in  
table 1 to maintain the internal function of the relay.  
• Use latching when conditions involve continuous carrying  
current.  
• Regarding the set and reset pulse time, for the purpose of  
reliable operation under ambient temperature fluctuations and  
different operating conditions, we recommend setting the coil  
applied set and reset pulse time to 10 ms or more at the rated  
coil voltage.  
A
D
E
• The relay is shipped in the reset position. But jolts during  
transport or impacts during installation can change the reset  
position. It is, therefore, advisable to build a circuit in which the  
relay can be initialized (set and reset) just after turning on the  
power.  
C
B
Please chuck the
 
ꢀꢀ
portion.  
Avoid chucking the center of the  
relay. In addition, excessive  
chucking pressure to the pinpoint of  
the relay should be also avoided.  
External magnetic field  
T
a
ble 1: Chucking pressure  
Since TX relays are highly sensitive polarized relays, their  
characteristics will be affected by a strong external magnetic  
field. Avoid using the relay under that condition.  
A, B and D direction  
C and E direction  
Max.  
Max.  
9
.
.
8
9
N (  
1
kgf)  
4
N (
500
gf)  
Panasonic Industry Co., Ltd. Electromechanical Control Business Division  
Panasonic Industry Co., Ltd. 2022  
ASCTB18E 20220
4  
ー 9 ー  
industrial.panasonic.com/ac/e/  

GUIDELINES FOR SIGNAL REL
A
Y
S USAGE  
For cautions for use, please read “GUIDELINES FOR REL
A
Y
U
SAGE”.  
PRECAUTIONS FOR COIL INPUT  
Long term current carrying  
Maximum allowable voltage and temperature rise  
A circuit that will be carrying a current continuously for  
long periods without relay switching operation. (circuits for  
emergency lamps, alarm devices and error inspection that, for  
example, revert only during malfunction and output warnings  
with form B contacts)  
Proper usage requires that the rated coil voltage be impressed  
on the coil.  
Note, however, that if a voltage greater than or equal to the  
maximum continuous voltage is impressed on the coil, the coil  
may burn or its layers short due to the temperature rise.  
Furthermore, do not exceed the usable ambient temperature  
range listed in the catalog.  
Continuous,long-term current to the coil will facilitate  
deterioration of coil insulation and characteristics due to  
heating of the coil itself. For circuits such as these, please use  
a magnetic-hold type latching relay. If you need to use a single  
stable relay, use a sealed type relay that is not easily affected  
by ambient conditions and make a failsafe circuit design that  
considers the possibility of contact failure or disconnection.  
Operate voltage change due to coil temperature rise (hot start)  
In DC relays, after continuous passage of current in the coil, if  
the current is turned OF
F
,
t
hen immediately turned ON again,  
due to the temperature rise in the coil, the operate voltage will  
become somewhat higher. Also, it will be the same as using it  
in a higher temperature atmosphere.  
DC Coil operating power  
The resistance/temperature relationship for copper wire is  
about 0.4% for 1°C, and with this ratio the coil resistance  
increases.  
Steady state DC current should be applied to the coil.  
The wave form should be rectangular. If it includes ripple, the  
ripple factor should be less than 5%. However, please check  
with the actual circuit since the electrical characteristics may  
vary.  
That is, in order to operate of the relay, it is necessary that the  
voltage be higher than the operate voltage and the operate  
voltage rises in accordance with the increase in the resistance  
value.  
The rated coil voltage should be applied to the coil and the  
set/reset pulse time of latching type relay differs for each  
relays, please refer to the relay’s individual specifications.  
However, for some polarized relays, this rate of change is  
considerably smaller.  
Coil connection  
When connecting coils of polarized relays, please check coil  
polarity(+,-) at the internal connection diagram (Schematic).  
If any wrong connection is made, it may cause unexpected  
malfunction, like abnormal heat, fire and so on, and circuit do  
not work.  
Avoid impressing voltages to the set coil and reset coil at the  
same time.  
Panasonic Industry Co., Ltd. Electromechanical Control Business Division  
Panasonic Industry Co., Ltd. 2022  
ASCTB414E 202204  
ー
1
0 ー  
industrial.panasonic.com/ac/e/  

GUIDELINES FOR SIGNAL RELAYS USAGE  
NOTES  
Condensation  
Usage, Storage, and Transport Conditions  
During usage, storage, or transportation, avoid locations  
subject to direct sunlight and maintain normal temperature,  
humidity, and pressure conditions.  
Condensation occurs when the ambient temperature drops  
suddenly from a high temperature and humidity, or the relay  
and microwave device is suddenly transferred from a low  
ambient temperature to a high temperature and humidity.  
Condensation causes the failures like insulation deterioration,  
wire disconnection and rust etc.  
The allowable specifications for environments suitable for  
usage, storage, and transportation are given below.  
1) Temperature: The allowable temperature range differs for  
each relay, so refer to the relay’s individual specifications.  
In addition, when transporting or storing relays while they are  
tube packaged, there are cases when the temperature may  
differ from the allowable range. In this situation, be sure to  
consult the individual specifications.  
Panasonic Industry Co., Ltd. does not guarantee the failures  
caused by condensation.  
The heat conduction by the equipment may accelerate the  
cooling of device itself, and the condensation may occur.  
Please conduct product evaluations in the worst condition of  
the actual usage. (Special attention should be paid when high  
temperature heating parts are close to the device. Also please  
consider the condensation may occur inside of the device.)  
2) Humidity: 5 to 85% RH  
The humidity range varies with the temperature.  
Use within the range indicated in the graph.  
(The allowable temperature depends on the relays.)  
Icing  
Humidity (% RH)  
Condensation or other moisture may freeze on relays when  
the temperature become lower than 0°C.  
This icing causes the sticking of movable portion, the operation  
delay and the contact conduction failure etc.  
Panasonic Industry Co., Ltd. does not guarantee the failures  
caused by the icing.  
85  
Allowable range  
Avoid icing  
Avoid con-  
when used at  
temperatures  
lower than 0
°
C  
densation when  
used at tem-  
peratures higher  
than 0
°
C  
The heat conduction by the equipment may accelerate the  
cooling of relay itself and the icing may occur.  
Please conduct product evaluations in the worst condition of  
the actual usage.  
5
-40  
0
85  
Ambient temperature (℃)  
Low temperature and low humidity  
The plastic becomes brittle if the switch is exposed to a low  
temperature, low humidity environment for long periods of  
time.  
3) Pressure: 86 to 106 kPa  
High temperature and high humidity  
Storage for extended periods of time (including transportation  
periods) at high temperature or high humidity levels or in  
atmospheres with organic gases or sulfide gases may cause a  
sulfide film or oxide film to form on the surfaces of the contacts  
and/or it may interfere with the functions.  
Check out the atmosphere in which the units are to be stored  
and transported.  
Package  
In terms of the packing format used, make every effort to keep  
the effects of moisture, organic gases and sulfide gases to the  
absolute minimum.  
Panasonic Industry Co., Ltd. Electromechanical Control Business Division  
Panasonic Industry Co., Ltd. 2022  
ASCTB414E 202204  
ー
1
1 ー  
industrial.panasonic.com/ac/e/  

GUIDELINES FOR SIGNAL RELAYS USAGE  
Storage requirements  
4
) The following cautionary label is affixed to the anti-humidity  
Since the surface-mount terminal type is sensitive to humidity  
it is packaged with tightly sealed anti-humidity packaging.  
However, when storing, please be careful of the following.  
1) Please use promptly once the anti-humidity pack is opened.  
(within 72 hours, Max. 30°C / 70% RH).  
pack.  
If left with the pack open, the relay will absorb moisture which  
will cause thermal stress when reflow mounting and thus  
cause the case to expand. As a result, the seal may break.  
2) If relays will not be used within 72 hours, please store relays  
in a humidity controlled desiccator or in an anti-humidity bag  
to which silica gel has been added.  
* If the relay is to be soldered after it has been exposed to excessive humidity  
atmosphere, cracks and leaks can occur.  
Be sure to mount the relay under the required mounting conditions.  
3) When relays (which is packaged with humidity indicator and  
silica gel) meeting one of below criteria, please bake (dry)  
before use.  
Silicon  
When a source of silicone substances (silicone rubber, silicone  
oil,silicone coating materials and silicone filling materials  
etc.) is used around the relay, the silicone gas (low molecular  
siloxane etc.) may be produced  
When the storage conditions specified in 1) are exceeded.  
Ⅲ
Ⅳ
When humidity indicator is in
 
or status
 
according to  
judgement standard.  
This silicone gas may penetrate into the inside of the relay.  
When the relay is kept and used in this condition, silicone  
compound may adhere to the relay contacts which may cause  
the contact failure.  
<How to judge>  
Please check humidity indicator color and decide if baking is  
necessary or not.  
: indicate brown,
 
: Other than brown (blueish color)  
●
○
Do not use any sources of silicone gas around the relay  
(Including plastic seal types).  
Bake treatment  
necessity judgment  
5
%
10  
%
60
%  
NOx Generation  
No need to bake  
No need to bake  
Need to bake  
Ⅰ
Ⅱ
Ⅲ
Ⅳ
●
●
●
When relay is used in an atmosphere high in humidity to  
switch a load which easily produces an arc, the NOx created  
by the arc and the water absorbed from outside the relay  
combine to produce nitric acid.  
○
○
○
●
○
○
●
●
○
Need to bake  
This corrodes the internal metal parts and adversely affects  
operation.  
Spot  
Avoid use at an ambient humidity of 85% RH or higher (at  
20°C).  
If use at high humidity is unavoidable, please contact our sales  
representative.  
5%  
10%  
60%  
Humidity indicator card  
<Baking (Drying) conditions>  
With reel : 45°C, 96 hours or more.  
Without reel (including relay only) : 60°C, 35 hours or more.  
Panasonic Industry Co., Ltd. Electromechanical Control Business Division  
Panasonic Industry Co., Ltd. 2022  
ASCTB414E 202204  
ー
1
2 ー  
industrial.panasonic.com/ac/e/  

GUIDELINES FOR SIGNAL RELAYS USAGE  
OTHERS  
Cleaning  
1) Although the environmentally sealed type relay (plastic sealed  
type,etc.) can be cleaned, avoid immersing the relay into cold  
liquid (such as cleaning solvent) immediately after soldering.  
Doing so may deteriorate the sealing performance.  
2) Surface-mount terminal type relay is sealed type and it can be  
cleaned by immersion.  
3) Cleaning with the boiling method is recommended (The  
temperature of cleaning liquid should be 40°C or lower). Avoid  
ultrasonic cleaning on relays.  
Use of ultrasonic cleaning may cause breaks in the coil or  
slight sticking of the contacts due to the ultrasonic energy.  
Use pure water or alcohol-based cleaning solvent.  
Please refer to
“the latest product specifications”  
when designing your product.  
•Requests to customers:  
Panasonic Industry Co., Ltd. Electromechanical Control Business Division  
Panasonic Industry Co., Ltd. 2022  
ASCTB414E 202204  
ー
1
3 ー  
industrial.panasonic.com/ac/e/  

Electromechanical Control Business Division  
1006, Oaza Kadoma, Kadoma-shi, Osaka 571-8506, Japan  
industral.panasonic.com/ac/e/  
Specifications are subject to change without notice.  
2022.4  
©Panasonic Industry Co., Ltd. 2022  