Phoenix-Contact-2900295

Part #Phoenix-Contact-2900295
Download 
Phoenix-Contact-2900295
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user’s  
documentation. Our General Terms of Use for Downloads are valid  
(http://phoenixcontact.com/download)  
PLC-INTERFACE for high continuous currents, consisting of PLC-BPT…/21 HC basic terminal block with  
Push-in connection and plug-in miniature relay, for mounting on DIN rail NS 35/7,5, limiting continuous current  
up to 10 A, 1 changeover contact, input voltage 60 V DC  
Your advantages  
Long electrical service life thanks to 16 A relay  
All common input voltages of 12 V DC to 230 V AC  
Efficient connection to system cabling using V8 adapter  
Safe isolation according to DIN EN 50178 between coil and contact  
Max. continuous current of 10 A  
Functional plug-in bridges  
Key Commercial Data  
Packing unit  
10 pc  
GTIN  
GTIN  
4046356507066  
Technical data  
Note  
EMC: class A product, see manufacturer’s declaration in the download  
area  
Utilization restriction  
Dimensions  
Width  
Height  
Depth  
14 mm  
80 mm  
94 mm  
Ambient conditions  
Ambient temperature (operation)  
Ambient temperature (storage/transport)  
Degree of protection  
-40 °C … 60 °C  
-40 °C … 85 °C  
RT II (Relay)  
03/12/2021 Page
 
1 / 17  

Technical data  
Ambient conditions  
IP20 (Relay base)  
Coil side  
Nominal input voltage U

N  

Typical input current at U

N  

Typical response time  
Typical release time  
Protective circuit  
60 V DC  
10 mA  
8 ms  
10 ms  
Reverse polarity protection Polarity protection diode  
Free-wheeling diode Damping diode  
Operating voltage display  
Yellow LED  
0.6 W  
Power dissipation for nominal condition  
Contact side  
Contact type  
1 changeover contact  
Single contact  
AgNi  
Type of switch contact  
Contact material  
250 V AC/DC (The separating plate PLC-ATP should be installed for  
voltages larger than 250 V (L1, L2, L3) between identical terminal blocks  
in adjacent modules. Potential bridging is then carried out with FBST 8-  
PLC… or …FBST 500…)  
Maximum switching voltage  
Minimum switching voltage  
Min. switching current  
12 V (at 10 mA)  
10 mA (at 12 V)  
30 A (300 ms)  
10 A  
Maximum inrush current  
Limiting continuous current  
6 A (value applies to connections 12. If connections 12 are bridged, the  
normal value applies.)  
Interrupting rating (ohmic load) max.  
240 W (at 24 V DC)  
58 W (at 48 V DC)  
48 W (at 60 V DC)  
50 W (at 110 V DC)  
80 W (at 220 V DC)  
2500 VA (for 250 V AC)  
144 W (for 24 V DC. Value applies to connections 12. If connections 12  
are bridged, the normal value applies.)  
Interrupting rating (ohmic load) max. bridged  
Switching capacity  
1500 VA (for 250 V AC. Value applies to connections 12. If connections  
12 are bridged, the normal value applies.)  
2 A (at 24 V, DC13)  
0.2 A (at 110 V, DC13)  
0.2 A (at 250 V, DC13)  
6 A (at 24 V, AC15)  
6 A (at 120 V, AC15)  
6 A (at 250 V, AC15)  
General  
03/12/2021 Page
 
2 / 17  

Technical data  
General  
Operating mode  
100% operating factor  
V0 (Housing)  
Flammability rating according to UL 94  
Mechanical service life  
Mounting position  
3x 10

7

cycles  
any  
Assembly instructions  
In rows with zero spacing  
Connection data  
Connection name  
Coil side  
Connection method  
Push-in connection  
8 mm  
Stripping length  
Conductor cross section solid  
Conductor cross section flexible  
0.14 mm² … 2.5 mm²  
0.14 mm² … 2.5 mm²  
0.2 mm² … 2.5 mm² (Single ferrule)  
2x 0.5 mm² … 1 mm² (TWIN ferrule)  
26 … 14  
Conductor cross section AWG  
Connection data 2  
Connection name  
Contact side  
Connection method  
Push-in connection  
8 mm  
Stripping length  
Conductor cross section solid  
Conductor cross section flexible  
0.14 mm² … 2.5 mm²  
0.14 mm² … 2.5 mm²  
0.2 mm² … 2.5 mm² (Single ferrule)  
2x 0.5 mm² … 1 mm² (TWIN ferrule)  
26 … 14  
Conductor cross section AWG  
Standards and Regulations  
Connection in acc. with standard  
Designation  
CUL  
Standards/regulations  
Standards/regulations  
IEC 60664  
EN 50178  
Rated surge voltage  
Insulation  
6 kV  
Safe isolation, reinforced insulation  
Pollution degree  
Overvoltage category  
2
III  
Conformance/approvals  
Designation  
Identification  
Corrosive gas test  
ISA-S71.04. G3 Harsh Group  
EN 60068-2-60  
Environmental Product Compliance  
REACh SVHC  
Lead 7439-92-1  
03/12/2021 Page
 
3 / 17  

Technical data  
Environmental Product Compliance  
China RoHS  
Environmentally Friendly Use Period = 50 years  
For details about hazardous substances go to tab “Downloads”,  
Category “Manufacturer’s declaration”  
Drawings  
Diagram  
Diagram  
20  
10  
U
U
1,4  
1,3  
1,2  
1,1  
1
1
6
N
4
A
2
3
2
1
0,5  
0,3  
0,2  
U

N

= 60 V DC  
0,1  
0,9  
0,8  
0,7  
10  
20  
30  
50 70
 
100  
200 300  
Switching voltage [V]  
B
1
2
3
AC, ohmic load  
DC, ohmic load  
DC, L/R = 40 ms  
20 25 30 35 40 45 50 55 60 65  
T
[
C]  
°
U
Interrupting rating  
Curve A  
Maximum permissible continuous voltage U

max

with limiting continuous  
current on the contact side (see relevant technical data)  
Curve B  
Minimum permissible operate voltage U

op

after pre-excitation (see  
relevant technical data)  
Circuit diagram  
11  
A2  
A1  
14  
12  
Articles in set  
14 mm PLC basic terminal block for high continuous currents with Push-in connection, without relay or solid-state  
relay, for mounting on DIN rail NS 35/7,5, 1 changeover contact, input voltage 60 V DC  
03/12/2021 Page
 
4 / 17  

Articles in set  
Plug-in miniature power relay, with power contact for high continuous currents, 1 changeover contact, 60 V DC  
Classifications  
eCl@ss  
eCl@ss 10.0.1  
eCl@ss 11.0  
eCl@ss 4.0  
eCl@ss 4.1  
eCl@ss 5.0  
eCl@ss 5.1  
eCl@ss 6.0  
eCl@ss 7.0  
eCl@ss 9.0  
27371601  
27371601  
27371000  
27371000  
27371600  
27371600  
27371600  
27371601  
27371601  
ETIM  
ETIM 2.0  
ETIM 3.0  
ETIM 4.0  
ETIM 5.0  
ETIM 6.0  
ETIM 7.0  
EC001437  
EC001437  
EC001437  
EC001437  
EC001437  
EC001437  
UNSPSC  
UNSPSC 6.01  
UNSPSC 7.0901  
UNSPSC 11  
30211916  
39121515  
39121515  
39121515  
39122334  
39122334  
39122334  
39122334  
39122334  
UNSPSC 12.01  
UNSPSC 13.2  
UNSPSC 18.0  
UNSPSC 19.0  
UNSPSC 20.0  
UNSPSC 21.0  
Approvals  
Approvals  
03/12/2021 Page
 
5 / 17  

Approvals  
Approvals  
UL Listed / UL Recognized / cUL Recognized / cUL Listed / RC FRT / EAC / EAC / DNV GL / cULus Recognized / cULus Listed  
Ex Approvals  
Approval details  
UL Listed  
UL Recognized  
cUL Recognized  
cUL Listed  
RC FRT  
FILE E 172140  
FILE E 238705  
FILE E 238705  
FILE E 172140  
B.00094  
EAC  
TR_TS_D_00573_c  
RU*C-  
DE.*08.B.00010  
EAC  
DNV GL  
TAE0000196-03  
03/12/2021 Page
 
6 / 17  

Approvals  
cULus Recognized  
cULus Listed  
Accessories  
Accessories  
Bridge  
Continuous plug-in bridge, length: 500 mm, color: red  
Continuous plug-in bridge, length: 500 mm, color: blue  
Continuous plug-in bridge, length: 500 mm, color: gray  
Single plug-in bridge, length: 6 mm, number of positions: 2, color: red  
03/12/2021 Page
 
7 / 17  

Accessories  
Single plug-in bridge, length: 6 mm, number of positions: 2, color: blue  
Single plug-in bridge, length: 6 mm, number of positions: 2, color: gray  
Single plug-in bridge, length: 8 mm, number of positions: 2, color: gray  
Single plug-in bridge, length: 14 mm, number of positions: 2, color: black  
DIN rail  
DIN rail perforated, Standard profile, width: 35 mm, height: 7.5 mm, acc. to EN 60715, material: Steel, galvanized,  
passivated with a thick layer, length: 2000 mm, color: silver  
03/12/2021 Page
 
8 / 17  

Accessories  
DIN rail, unperforated, Standard profile, width: 35 mm, height: 7.5 mm, acc. to EN 60715, material: Steel, galvanized,  
passivated with a thick layer, length: 2000 mm, color: silver  
DIN rail perforated, Standard profile, width: 35 mm, height: 7.5 mm, acc. to EN 60715, material: Steel, Galvanized,  
white passivated, length: 2000 mm, color: silver  
DIN rail, unperforated, Standard profile, width: 35 mm, height: 7.5 mm, acc. to EN 60715, material: Steel, Galvanized,  
white passivated, length: 2000 mm, color: silver  
DIN rail, unperforated, Standard profile, width: 35 mm, height: 7.5 mm, acc. to EN 60715, material: Aluminum,  
uncoated, length: 2000 mm, color: silver  
DIN rail perforated, Standard profile, width: 35 mm, height: 7.5 mm, acc. to EN 60715, material: Steel, galvanized,  
length: 2000 mm, color: silver  
03/12/2021 Page
 
9 / 17  

Accessories  
DIN rail, unperforated, Standard profile, width: 35 mm, height: 7.5 mm, acc. to EN 60715, material: Steel, galvanized,  
length: 2000 mm, color: silver  
DIN rail, unperforated, Standard profile, width: 35 mm, height: 7.5 mm, acc. to EN 60715, material: Copper, uncoated,  
length: 2000 mm, color: copper-colored  
DIN rail end piece, for DIN rail NS 35/7.5  
DIN rail perforated, Standard profile, width: 35 mm, height: 15 mm, similar to EN 60715, material: Steel, galvanized,  
passivated with a thick layer, length: 2000 mm, color: silver  
DIN rail, unperforated, Standard profile, width: 35 mm, height: 15 mm, similar to EN 60715, material: Steel,  
galvanized, passivated with a thick layer, length: 2000 mm, color: silver  
03/12/2021 Page
 
10 / 17  

Accessories  
DIN rail perforated, Standard profile, width: 35 mm, height: 15 mm, similar to EN 60715, material: Steel, Galvanized,  
white passivated, length: 2000 mm, color: silver  
DIN rail, unperforated, Standard profile, width: 35 mm, height: 15 mm, similar to EN 60715, material: Steel,  
Galvanized, white passivated, length: 2000 mm, color: silver  
DIN rail, unperforated, Standard profile, width: 35 mm, height: 15 mm, similar to EN 60715, material: Aluminum,  
uncoated, length: 2000 mm, color: silver  
DIN rail perforated, Standard profile, width: 35 mm, height: 15 mm, similar to EN 60715, material: Steel, galvanized,  
length: 2000 mm, color: silver  
DIN rail, unperforated, Standard profile, width: 35 mm, height: 15 mm, similar to EN 60715, material: Steel,  
galvanized, length: 2000 mm, color: silver  
03/12/2021 Page
 
11 / 17  

Accessories  
DIN rail, unperforated, Standard profile, width: 35 mm, height: 15 mm, similar to EN 60715, material: Copper,  
uncoated, length: 2000 mm, color: copper-colored  
DIN rail end piece, for DIN rail NS 35/15  
DIN rail, unperforated, Standard profile 2.3 mm, width: 35 mm, height: 15 mm, acc. to EN 60715, material: Steel,  
galvanized, passivated with a thick layer, length: 2000 mm, color: silver  
Labeled terminal marker  
Zack marker strip, can be ordered: Strip, white, labeled according to customer specifications, mounting type: snap  
into tall marker groove, for terminal block width: 10.2 mm, lettering field size: 10.15 x 10.5 mm, Number of individual  
labels: 10  
Zack marker strip, Strip, white, labeled, can be labeled with: CMS-P1-PLOTTER, printed horizontally: consecutive  
numbers 1 … 10, 11 … 20, etc. up to 91 … 100, mounting type: snap into tall marker groove, for terminal block width:  
10.2 mm, lettering field size: 10.15 x 10.5 mm, Number of individual labels: 10  
03/12/2021 Page
 
12 / 17  

Accessories  
Zack marker strip, Strip, white, labeled, can be labeled with: CMS-P1-PLOTTER, Printed vertically: consecutive  
numbers 1 … 10, 11 … 20, etc. up to 91 … 100, mounting type: snap into tall marker groove, for terminal block width:  
10.2 mm, lettering field size: 10.15 x 10.5 mm, Number of individual labels: 10  
Marker for terminal blocks, Strip, white, labeled, can be labeled with: CMS-P1-PLOTTER, horizontal: L1, L2, L3, N,  
PE, L1, L2, L3, N, PE, mounting type: snap into tall marker groove, for terminal block width: 10.2 mm, lettering field  
size: 10.15 x 10.5 mm, Number of individual labels: 10  
Marker for terminal blocks, Strip, white, labeled, can be labeled with: CMS-P1-PLOTTER, horizontal: U, V, W, N,  
GND, U, V, W, N, GND, mounting type: snap into tall marker groove, for terminal block width: 10.2 mm, lettering field  
size: 10.15 x 10.5 mm, Number of individual labels: 10  
Marker for terminal blocks, can be ordered: by sheet, white, labeled according to customer specifications, mounting  
type: snap into tall marker groove, for terminal block width: 10.2 mm, lettering field size: 9.6 x 10.5 mm, Number of  
individual labels: 48  
Marker for terminal blocks, can be ordered: by sheet, white, labeled according to customer specifications, mounting  
type: snap into tall marker groove, for terminal block width: 10.2 mm, lettering field size: 8.9 x 9.6 mm, Number of  
individual labels: 36  
03/12/2021 Page
 
13 / 17  

Accessories  
Zack marker strip, can be ordered: Strip, white, labeled according to customer specifications, mounting type: snap  
into tall marker groove, for terminal block width: 12.2 mm, lettering field size: 10.5 x 12.15 mm, Number of individual  
labels: 5  
Zack marker strip, Strip, white, labeled, printed horizontally: L1, L2, L3, N, PE, mounting type: snap into tall marker  
groove, for terminal block width: 12.2 mm, lettering field size: 10.5 x 12.15 mm, Number of individual labels: 5  
Marker for terminal blocks, can be ordered: by sheet, white, labeled according to customer specifications, mounting  
type: snap into tall marker groove, for terminal block width: 12 mm, lettering field size: 11.45 x 10.5 mm, Number of  
individual labels: 40  
Marker for terminal blocks, can be ordered: by sheet, white, labeled according to customer specifications, mounting  
type: snap into tall marker groove, for terminal block width: 12 mm, lettering field size: 10.8 x 9.6 mm, Number of  
individual labels: 30  
Partition plate  
Separating plate, 2 mm thick, required at the start and end of a PLC terminal strip. Furthermore, it is used for: visual  
separation of groups, safe isolation of different voltages of neighboring PLC relays in acc. with DIN VDE 0106-101,  
isolation  
Power module  
03/12/2021 Page
 
14 / 17  

Accessories  
Power terminal block, for the input of up to four potentials, for mounting on NS 35/7.5  
Screwdriver tools  
Actuation tool, for ST terminal blocks, also suitable for use as a bladed screwdriver, size: 0.6 x 3.5 x 100 mm, 2-  
component grip, with non-slip grip  
Terminal marking  
Zack marker strip, Strip, white, unlabeled, can be labeled with: PLOTMARK, CMS-P1-PLOTTER, mounting type:  
snap into tall marker groove, for terminal block width: 10.2 mm, lettering field size: 10.5 x 10.15 mm, Number of  
individual labels: 10  
Marker for terminal blocks, Sheet, white, unlabeled, can be labeled with: BLUEMARK ID COLOR, BLUEMARK ID,  
BLUEMARK CLED, PLOTMARK, CMS-P1-PLOTTER, mounting type: snap into tall marker groove, for terminal block  
width: 10.2 mm, lettering field size: 9.6 x 10.5 mm, Number of individual labels: 48  
Marker for terminal blocks, Sheet, white, unlabeled, can be labeled with: TOPMARK NEO, TOPMARK LASER,  
BLUEMARK ID COLOR, BLUEMARK ID, BLUEMARK CLED, THERMOMARK PRIME, THERMOMARK CARD 2.0,  
THERMOMARK CARD, mounting type: snap into tall marker groove, for terminal block width: 10.2 mm, lettering field  
size: 8.9 x 9.6 mm, Number of individual labels: 36  
03/12/2021 Page
 
15 / 17  

Accessories  
Zack marker strip, Strip, white, unlabeled, can be labeled with: PLOTMARK, CMS-P1-PLOTTER, mounting type:  
snap into tall marker groove, for terminal block width: 12.2 mm, lettering field size: 12 x 10.5 mm, Number of  
individual labels: 5  
Marker for terminal blocks, Sheet, white, unlabeled, can be labeled with: BLUEMARK ID COLOR, BLUEMARK ID,  
BLUEMARK CLED, PLOTMARK, CMS-P1-PLOTTER, mounting type: snap into tall marker groove, for terminal block  
width: 12 mm, lettering field size: 11.45 x 10.5 mm, Number of individual labels: 40  
Marker for terminal blocks, Sheet, white, unlabeled, can be labeled with: TOPMARK NEO, TOPMARK LASER,  
BLUEMARK ID COLOR, BLUEMARK ID, BLUEMARK CLED, THERMOMARK PRIME, THERMOMARK CARD 2.0,  
THERMOMARK CARD, mounting type: snap into tall marker groove, for terminal block width: 12 mm, lettering field  
size: 10.8 x 9.6 mm, Number of individual labels: 30  
Spare parts  
14 mm PLC basic terminal block for high continuous currents with Push-in connection, without relay or solid-state  
relay, for mounting on DIN rail NS 35/7,5, 1 changeover contact, input voltage 60 V DC  
Plug-in miniature power relay, with power contact for high continuous currents, 1 changeover contact, 60 V DC  
03/12/2021 Page
 
16 / 17  

Phoenix Contact 2021 © – all rights reserved  
PHOENIX CONTACT GmbH & Co. KG  
Flachsmarktstr. 8  
32825 Blomberg  
Germany  
Tel. +49 5235 300  
Fax +49 5235 3 41200  
03/12/2021 Page
 