Phoenix-Contact-2912604

Part #Phoenix-Contact-2912604
Download 
Phoenix-Contact-2912604
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user’s  
documentation. Our General Terms of Use for Downloads are valid  
(http://phoenixcontact.com/download)  
PLC-INTERFACE, consisting of PLC-BSP…/21-21AU basic terminal block with spring-cage connection and plug-  
in miniature relay with multi-layer gold contact, for mounting on DIN rail NS 35/7,5, 2 PDTs, input voltage 60 V DC  
Product Features  
Slim design  
Efficient connection to system cabling using V8 adapter  
RT III sealed relay  
Safe isolation according to DIN EN 50178 between coil and contact  
Integrated input circuit and interference suppression circuit  
Functional plug-in bridges  
Key commercial data  
Packing unit  
1 pc  
Weight per Piece (excluding packing)  
Custom tariff number  
Country of origin  
61.2 GRM  
85364190  
Germany  
Technical data  
Note  
EMC: class A product, see manufacturer’s declaration in the download  
area  
Utilization restriction  
Dimensions  
Width  
Height  
Depth  
14 mm  
80 mm  
94 mm  
Ambient conditions  
10/27/2014 Page
 
1 / 6  

Technical data  
Ambient conditions  
Ambient temperature (operation)  
-40 °C … 60 °C  
-40 °C … 85 °C  
Ambient temperature (storage/transport)  
Coil side  
Nominal input voltage U

N  

Typical input current at U

N  

Typical response time  
Typical release time  
60 V DC  
10 mA  
8 ms  
10 ms  
Operating voltage display  
Protective circuit  
Yellow LED  
Protection against polarity reversal Polarity protection diode  
Free-wheeling diode Damping diode  
Contact side  
Contact type  
2 PDT  
Contact material  
AgNi, hard gold-plated  
30 V AC  
Maximum switching voltage  
36 V DC  
Minimum switching voltage  
Maximum inrush current  
Min. switching current  
100 mV (at 10 mA)  
50 mA  
1 mA (at 24 V)  
Limiting continuous current  
Interrupting rating (ohmic load) max.  
Note  
50 mA  
1.2 W (at 24 V DC)  
the following values are applicable if a gold layer is destroyed  
250 V AC/DC  
Maximum switching voltage  
Minimum switching voltage  
Limiting continuous current  
Maximum inrush current  
Min. switching current  
5 V AC/DC  
6 A  
15 A (300 ms)  
10 mA  
Interrupting rating (ohmic load) max.  
140 W (at 24 V DC)  
85 W (at 48 V DC)  
60 W (at 60 V DC)  
44 W (at 110 V DC)  
60 W (at 220 V DC)  
1500 VA (for 250 V AC)  
2 A (at 24 V, DC13)  
0.2 A (at 110 V, DC13)  
0.2 A (at 250 V, DC13)  
2 A (at 24 V, AC15)  
Switching capacity in acc. with DIN VDE 0660/IEC 60947  
10/27/2014 Page
 
2 / 6  

Technical data  
Contact side  
2 A (at 120 V, AC15)  
2 A (at 250 V, AC15)  
General  
Operating mode  
100% operating factor  
RT III (Relay)  
Degree of protection  
Mechanical service life  
Inflammability class according to UL 94  
Designation  
3 x 10

7

cycles  
V0  
Standards/regulations  
Standards/regulations  
IEC 60664  
EN 50178  
IEC 62103  
Rated surge voltage / insulation  
Pollution degree  
6 kV / Basic isolation  
2
Surge voltage category  
Mounting position  
III  
any  
Assembly instructions  
In rows with zero spacing  
Connection data  
Connection method  
Spring-cage connection  
Stripping length  
8 mm  
Conductor cross section stranded min.  
Conductor cross section stranded max.  
Conductor cross section solid min.  
Conductor cross section solid max.  
Conductor cross section AWG/kcmil max  
Conductor cross section AWG/kcmil min.  
0.14 mm²  
2.5 mm²  
0.14 mm²  
2.5 mm²  
14  
26  
Classifications  
eCl@ss  
eCl@ss 4.0  
eCl@ss 4.1  
eCl@ss 5.0  
eCl@ss 5.1  
eCl@ss 6.0  
eCl@ss 7.0  
eCl@ss 8.0  
27371102  
27371102  
27371001  
27371001  
27371001  
27371001  
27371001  
10/27/2014 Page
 
3 / 6  

Classifications  
ETIM  
ETIM 2.0  
ETIM 3.0  
ETIM 4.0  
ETIM 5.0  
EC000196  
EC000196  
EC000196  
EC000196  
UNSPSC  
UNSPSC 6.01  
UNSPSC 7.0901  
UNSPSC 11  
30211916  
39121515  
39121515  
39121515  
39121515  
UNSPSC 12.01  
UNSPSC 13.2  
Approvals  
Approvals  
Approvals  
UL Listed / cUL Listed / GL / UL Recognized / cUL Recognized / cULus Recognized / cULus Listed  
Ex Approvals  
Approvals submitted  
Approval details  
UL Listed  
cUL Listed  
GL  
10/27/2014 Page
 
4 / 6  

Approvals  
UL Recognized  
cUL Recognized  
cULus Recognized  
cULus Listed  
Drawings  
Circuit diagram  
21  
24  
22  
A2  
A1  
11  
14  
12  
10/27/2014 Page
 
5 / 6  

Diagram  
Curve A  
Maximum permissible continuous voltage U

max

with limiting continuous current on the contact side (see relevant technical data)  
Curve B  
Minimum permissible operate voltage U

op

after pre-excitation (see relevant technical data)  
Phoenix Contact 2014 © – all rights reserved  
10/27/2014 Page
 