RSB1A160RD
Harmony, Interface plug-in relay, 16 A, 1 CO, 6
V DC
Main
Range of Product
Harmony Electromechanical Relays
Interface relay
Series name
Product or Component
Type
Plug-in relay
Device short name
RSB
Contacts type and
composition
1 C/O
Contact operation
Standard
6 V DC
[Uc] control circuit
voltage
[Ithe] conventional
enclosed thermal
current
16 A -40…104 °F (-40…40 °C)
Status LED
Without
Control Type
Without push-button
Complementary
Shape of pin
Flat (PCB type)
Average coil resistance
[Ue] rated operational voltage
[Ui] rated insulation voltage
[Uimp] rated impulse withstand voltage
Contacts material
90 Ohm AC 20 °C +/- 10 %
4.2…9 V DC
400 V EN/IEC 60947
3.6 kV IEC 61000-4-5
Silver alloy (AgNi)
[Ie] rated operational current
16 A AC-1/DC-1) NO IEC
8 A AC-1/DC-1) NC IEC
Minimum switching current
Maximum switching voltage
Minimum switching voltage
Maximum switching capacity
Resistive rated load
10 mA
300 V DC IEC
12 V
4000 VA/448 W
16 A 250 V AC
16 A 28 V DC
Minimum switching capacity
Operating rate
120 mW 10 mA, 12 V
<= 600 cycles/hour under load
<= 18000 cycles/hour no-load
Mechanical durability
Electrical durability
30000000 cycles
100000 Cycles, 16 A at 250 V, AC-1 NO
100000 cycles, 8 A at 250 V, AC-1 NC
Operating time
20 ms operating
20 ms reset
Average coil consumption
Drop-out voltage threshold
Safety reliability data
Protection category
Test levels
0.45 W DC
>= 0.1 Uc DC
B10d = 100000
RT I
Level A
Operating position
Net Weight
Any position
0.03 lb(US) (0.014 kg)
10
Sale per indivisible quantity
Device presentation
Complete product
Jan 13, 2022
1
Environment
Dielectric strength
1000 V AC between contacts
2500 V AC between poles
5000 V AC between coil and contact
Standards
UL 508
CSA C22.2 No 14
EN/IEC 61810-1
Product Certifications
CSA
EAC
UL
Ambient Air Temperature for Storage
Vibration resistance
-40…185 °F (-40…85 °C)
+/- 1 mm 10…55 Hz)EN/IEC 60068-2-6
IP40 conforming to EN/IEC 60529
IP degree of protection
Shock resistance
10 gn 11 ms) not operating EN/IEC 60068-2-27
5 gn 11 ms) in operation EN/IEC 60068-2-27
Ambient air temperature for operation
-40…185 °F (-40…85 °C) DC)
Ordering and shipping details
Category
21127 – ZELIO ICE CUBE RELAYS
Discount Schedule
GTIN
CP2
3389110254297
Nbr. of units in pkg.
Package weight(Lbs)
Returnability
1
0.56 oz (16 g)
No
AT
Country of origin
Packing Units
Unit Type of Package 1
Package 1 Height
Package 1 width
PCE
0.67 in (1.7 cm)
0.98 in (2.5 cm)
1.22 in (3.1 cm)
Package 1 Length
Offer Sustainability
Sustainable offer status
California proposition 65
Green Premium product
WARNING: This product can expose you to chemicals including: Nickel
compounds, which is known to the State of California to cause cancer, and
Di-isodecyl phthalate (DIDP), which is known to the State of California to
cause birth defects or other reproductive harm. For more information go to
REACh Regulation
EU RoHS Directive
Pro-active compliance (Product out of EU RoHS legal scope)
Toxic heavy metal free
Mercury free
Yes
Yes
RoHS exemption information
China RoHS Regulation
Environmental Disclosure
WEEE
The product must be disposed on European Union markets following specific
waste collection and never end up in rubbish bins.
Contractual warranty
Warranty
18 months
2
Product data sheet
Dimensions Drawings
RSB1A160RD
Dimensions
3
Product data sheet
Connections and Schema
RSB1A160RD
Wiring Diagram
(1) Terminals 11 and 21,14 and 24,12 and 22 must be linked for this references
NOTE: For DC input, A1 have to be +, otherwise it would short circuit from protection module
4
Product data sheet
Performance Curves
RSB1A160RD
Electrical Durability of Contacts
Durability (inductive load) = durability (resistive load) x reduction coefficient.
Resistive AC load
X Switching capacity (kVA)
Y Durability (Number of operating cycles)
Reduction coefficient for inductive AC load (depending on power factor cos ϕ)
Y Reduction coefficient (A)
Maximum switching capacity on resistive DC load
X Voltage DC
Y Current DC
Note :
These are typical curves, actual durability depends on load, environment, duty cycle, etc.