Schneider-RXG12JD

Part #Schneider-RXG12JD
Download 
Schneider-RXG12JD
Product data sheet  
Characteristics  
RXG12JD  
Harmony, Interface plug-in relay, 10 A, 1 CO,  
with LED, with lockable test button, 12 V DC  
Main  
Range of Product  
Harmony Electromechanical Relays  
Interface relay  
Series name  
Product or Component  
Type  
Plug-in relay  
Device short name  
RXG  
Contacts type and  
composition  
1 C/O  
Complementary  
Status LED  
With  
Contacts material  
Silver alloy (AgSnO2In2O3)  
100 mOhm  
Maximum contact resistance  
[Ithe] conventional enclosed thermal current  
[Ie] rated operational current  
10 A -40…131 °F (-40…55 °C)  
10 A 30 V DC) UL  
10 A 30 V DC) IEC  
10 A 250 V AC) IEC  
10 A 250 V AC) UL  
Maximum switching voltage  
250 V AC  
30 V DC  
Load current  
10 A 250 V AC  
Maximum switching capacity  
Minimum switching capacity  
Operating rate  
2500 VA  
500 mW at 100 mA, 5 V DC  
<= 1800 cycles/hour under load  
<= 18000 cycles/hour no-load  
Utilisation coefficient  
Mechanical durability  
Electrical durability  
20 %  
10000000 cycles  
100000 Cycles NO resistive at 55 °C  
100000 cycles NC resistive at 55 °C  
[Ui] rated insulation voltage  
250 V IEC  
300 V CSA  
300 V UL  
[Uimp] rated impulse withstand voltage  
Dielectric strength  
6 kV 1.2/50 µs  
1000 V AC between contacts with micro disconnection  
5000 V AC between coil and contact with reinforced insulation  
Coil resistance  
270 Ohm +/- 10 %  
1000 MOhm at 500 V DC  
Level A  
Insulation resistance  
Test levels  
Mounting position  
Drop-out voltage threshold  
Coil insulation class  
Operate time  
Any position  
>= 0.1 Uc DC  
Class F  
20 ms  
Release time  
20 ms  
[Uc] control circuit voltage  
Safety reliability data  
Colour of cover  
12 V DC  
B10d = 100000  
Standard  
Jan 13, 2022  
1

Control Type  
Lockable test button  
Flag  
Local signalling  
Torque Value  
Net Weight  
7.08 lbf.in (0.8 N.m)  
0.04 lb(US) (0.02 kg)  
Complete product  
Device presentation  
Environment  
Vibration resistance  
3 gn +/- 0.75 mm 10…150 Hz)in operation  
5 gn +/- 0.75 mm 10…150 Hz)not in operation  
IP Degree of Protection  
Shock resistance  
IP40  
20 gn in operation  
100 gn not in operation  
Protection category  
Standards  
RT I  
UL 508  
CSA C22.2 No 14  
IEC 61810-1  
Product Certifications  
EAC  
CE  
CSA  
UL  
Pollution degree  
2
Overvoltage category  
III  
Ambient Air Temperature for Storage  
Ambient air temperature for operation  
Relative humidity  
-40…185 °F (-40…85 °C)  
-40…158 °F (-40…70 °C)  
10…85 %  
Ordering and shipping details  
Category  
21127 – ZELIO ICE CUBE RELAYS  
Discount Schedule  
GTIN  
CP2  
3606480688720  
Nbr. of units in pkg.  
Package weight(Lbs)  
Returnability  
1
8.04 oz (228 g)  
Yes  
CN  
Country of origin  
Packing Units  
Unit Type of Package 1  
Package 1 Height  
Package 1 width  
PCE  
1.36 in (34.5 mm)  
3.64 in (92.5 mm)  
3.39 in (86 mm)  
Package 1 Length  
Offer Sustainability  
Sustainable offer status  
California proposition 65  
Green Premium product  
WARNING: This product can expose you to chemicals including: Nickel  
compounds, which is known to the State of California to cause cancer, and  
Di-isodecyl phthalate (DIDP), which is known to the State of California to  
cause birth defects or other reproductive harm. For more information go to  
REACh Regulation  
Yes  
REACh free of SVHC  
EU RoHS Directive  
Pro-active compliance (Product out of EU RoHS legal scope)  
Toxic heavy metal free  
Mercury free  
Yes  
Yes  
RoHS exemption information  
China RoHS Regulation  
Environmental Disclosure  
2

Product data sheet  
Dimensions Drawings  
RXG12JD  
Dimensions  
3

Product data sheet  
Connections and Schema  
RXG12JD  
Wiring Diagram  
4

Product data sheet  
Performance Curves  
RXG12JD  
Performance Curves  
Maximum Switching Capacity  
X : Switching voltage (V)  
Y : Switching current (A)  
(1) AC Resistive Load  
(2) AC Inductive Load cos(Ø)=0.4  
(3) DC Resistive Load  
(4) DC Inductive Load (L/R=7ms)  
Life Expectancy  
Resistive Load  
X : Contact Current (A)  
Y : Operating Cycle Number  
Life Expectancy  
Inductive Load  
X : Contact Current (A)  
Y : Operating Cycle Number  
NOTE: These are typical curves, actual durability depends on load, environment, duty cycle, etc.  
Coil Operating Range  
5

DC Coil Operating Range VS Ambient Temperature  
X : Ambient temperature (°C)  
Y : Coil voltage (U/Uc)  
(1) Permitted operating range area  