Schneider-RXM2AB2B7PVM
| Part # | Schneider-RXM2AB2B7PVM |
| Download | Schneider-RXM2AB2B7PVM |
Product data sheet
Characteristics
RXM2AB2B7PVM
Harmony, Miniature plug-in relay pre-
assembled, 10 A, 2 CO, with LED, with
lockable test button, mixed terminals socket, 24
V AC
Main
Range of Product
Harmony Electromechanical Relays
Miniature
Series name
Product or Component
Type
Pre-assembled plug-in relay with socket
Device short name
RXM
Contacts type and
composition
2 C/O
[Uc] control circuit
voltage
24 V AC 50/60 Hz
Status LED
With
Control Type
Lockable test button
20 %
Utilisation coefficient
Complementary
[Ui] rated insulation voltage
[Uimp] rated impulse withstand voltage
Contacts material
250 V IEC
4 kV 1.2/50 µs
AgNi
[Ie] rated operational current
6 A 28 V DC) NC IEC
6 A 250 V AC) NC IEC
10 A 28 V DC) NO UL
10 A 250 V AC) NO UL
Minimum switching current
Continuous output current
Maximum switching voltage
Minimum switching voltage
Resistive rated load
10 mA
10 A
250 V
17 V
10 A 250 V AC
10 A 28 V DC
Maximum switching capacity
2500 VA AC
280 W DC
Minimum switching capacity
Operating rate
170 mW 10 mA, 17 V
<= 1200 cycles/hour under load
<= 18000 cycles/hour no-load
Mechanical durability
Electrical durability
Average coil consumption
Drop-out voltage threshold
Operate time
10000000 cycles
100000 cycles resistive
1.2 W, AC
>= 0.3 Uc AC
20 ms
Release time
20 ms
Average coil resistance
Rated operational voltage limits
Safety reliability data
Protection category
Test levels
180 Ohm 20 °C +/- 10 %
19.2…26.4 V AC
B10d = 100000
RT I
Level A
Operating position
Any position
30
Sale per indivisible quantity
CAD overall width
1.06 in (26.9 mm)
Jul 13, 2022
1
CAD overall height
CAD overall depth
3.11 in (79 mm)
3.09 in (78.45 mm)
Connections – terminals
Connector, 1 x 0.25…1 x 2.5 mm² AWG 22…AWG 14) flexible with cable end
Connector, 2 x 0.25…2 x 1 mm² AWG 22…AWG 17) flexible with cable end
Connector, 1 x 0.5…1 x 2.5 mm² AWG 20…AWG 14) solid without cable end
Connector, 2 x 0.5…2 x 1.5 mm² AWG 20…AWG 16) solid without cable end
Torque Value
Net Weight
8.85 lbf.in (1 N.m)
0.21 lb(US) (0.096 kg)
Complete product
Device presentation
Environment
Dielectric strength
1300 V AC between contacts with micro disconnection
2000 V AC between coil and contact with basic insulation
2000 V AC between poles with basic insulation
Product Certifications
CE
UL
CSA
EAC
Lloyd’s
Standards
UL 508
EN/IEC 61810-1
CSA C22.2 No 14
IEC 61984
Ambient Air Temperature for Storage
Ambient air temperature for operation
Vibration resistance
-40…185 °F (-40…85 °C)
-40…131 °F (-40…55 °C)
3 gn +/- 1 mm 10…150 Hz)5 cycles in operation
5 gn +/- 1 mm 10…150 Hz)5 cycles not operating
IP degree of protection
Shock resistance
IP20 conforming to EN/IEC 60529
10 gnin operation
30 gnnot operating
Pollution degree
2
Ordering and shipping details
Category
21127-ZELIO ICE CUBE RELAYS
Discount Schedule
GTIN
CP2
3606489563165
Nbr. of units in pkg.
Package weight(Lbs)
Returnability
1
3.17 oz (90.0 g)
Yes
Packing Units
Unit Type of Package 1
PCE
Package 1 Height
1.10 in (2.8 cm)
3.15 in (8 cm)
3.15 in (8 cm)
S03
Package 1 width
Package 1 Length
Unit Type of Package 2
Number of Units in Package 2
Package 2 Weight
Package 2 Height
270
66.39 lb(US) (30.115 kg)
11.81 in (30 cm)
11.81 in (30 cm)
15.75 in (40 cm)
BB1
Package 2 width
Package 2 Length
Unit Type of Package 3
Number of Units in Package 3
Package 3 Weight
Package 3 Height
30
6.66 lb(US) (3.023 kg)
3.94 in (10 cm)
9.84 in (25 cm)
11.81 in (30 cm)
Package 3 width
Package 3 Length
2
Offer Sustainability
Sustainable offer status
California proposition 65
Green Premium product
WARNING: This product can expose you to chemicals including: Nickel
compounds, which is known to the State of California to cause cancer, and
Di-isodecyl phthalate (DIDP), which is known to the State of California to
cause birth defects or other reproductive harm. For more information go to
REACh Regulation
Yes
REACh free of SVHC
EU RoHS Directive
Pro-active compliance (Product out of EU RoHS legal scope)
Toxic heavy metal free
Mercury free
Yes
Yes
RoHS exemption information
China RoHS Regulation
Environmental Disclosure
WEEE
The product must be disposed on European Union markets following specific
waste collection and never end up in rubbish bins.
Contractual warranty
Warranty
18 Months
3
Product data sheet
Dimensions Drawings
RXM2AB2B7PVM
Dimensions
4
Product data sheet
Connections and Schema
RXM2AB2B7PVM
Wiring Diagram
Symbols shown in blue correspond to Nema marking.
5
Product data sheet
Performance Curves
RXM2AB2B7PVM
Electrical Durability of Contacts
Durability (inductive load) = durability (resistive load) x reduction coefficient.
Resistive AC load
X Switching capacity (kVA)
Y Durability (Number of operating cycles)
A RXM2AB•••
B RXM3AB•••
C RXM4ΑΒ•••
D RXM4GΒ•••
Reduction coefficient for inductive AC load (depending on power factor cos ϕ)
Y Reduction coefficient (A)
Maximum switching capacity on resistive DC load
X Voltage DC
Y Current DC
A RXM2AB•••
B RXM3AB•••
C RXM4ΑΒ•••
D RXM4GΒ•••
Note :
These are typical curves, actual durability depends on load, environment, duty cycle, etc.
6