SCHURTER-FMAB-N4PG-0146
| Part # | SCHURTER-FMAB-N4PG-0146 |
| Download | SCHURTER-FMAB-N4PG-0146 |
1-Phase Line Filters
FMAB HV
AC / DC Filte
r
,
H
igh Symmetrical Attenuation
See below:
Approvals and Compliances
Description
– Filter for 277 VAC or 400 VDC applications
– 1-stage
Characteristics
– For 277 VAC applications in North America WYE 480/277 volt system
For 400 VDC applications e.g. data center
– Especially designed forapplications with symmetrical noise caused by
switching semiconductors
– Suitable for use in equipment according to IEC/UL 62368-1
Suitable for use in medical equipment according to IEC/UL 60601-1 (1
MOO
P
, 1
M
OPP)
– Compact filter with high symmetrical attenuation
Unique Selling Proposition
– For high AC- or DC-voltages
– Excellent symmetrical attenuation
– Completely enclosed steel housing
– Optional overvoltage protection
Other versions on request
– Version with varistor for overvoltage protection
Weblinks
T
e
chnical Data
Ratings IEC
1 – 2
0
A @
T
a
4
0 °C / 27
7
V
AC; 5
0
H
z
Line Filter
MTBF
Standard, medical and industrial ver-
sion, IEC 60939, UL 1283, CSA C22.2
no. 8
> 200’00
0
h
a
cc. to MIL-HB-217 F
1 – 20 A @
T
u
4
0 °C / 277 VDC
1 – 2
0
A @
T
a
4
0 °C / 27
7
V
AC; 6
0
H
z
1 – 20 A @
T
u
4
0 °C / 400 VDC
industrial <
1
m
A (25
0
V /
6
0
H
z)
> 1.
7
k
VDC between L-N
> 2.
7
k
VDC between L/N-PE
T
e
st voltage (
2
s
ec)
Ratings UL/CSA
Leakage Current
Dielectric Strength
Allowable Operation
T
e
mpe-
rature
-4
0
°
C to 10
0
°
C
Climatic Category
Protection Class
40/100/21 acc. to IEC 60068-1
Suitable for appliances with protection
class I acc. to IEC 61140
Quick connect terminal 6.3 x 0.8 mm
Metal
T
e
rminal
Material
Approvals and Compliances
Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in
Details about
SCHURTER products are designed for use in industrial environments. They have approvals from independent testing bodies according to national
and international standards. Products with specific characteristics and requirements such as required in the automotive sector according to IATF
16949, medical technology according to ISO 13485 or in the aerospace industry can be offered exclusively with customer-specific, individual agree-
ments by SCHURTER.
Approvals
The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products.
Approval Reference
T
y
pe: FMAB HV
Approval Logo
Certificates
Certification Body
Description
VDE
Certificate Number: 40050001
UL
UR File Number: E495089
1
EMC Products
1-Phase Line Filters
FMAB HV
Product standards
Product standards that are referenced
Organization
Design
Standard
Description
Designed according to
IEC 60939
Passive filters for suppressing electromagnetic interference
Switches for appliances. Part 1. General requirements
Electromagnetic interference filters
Designed according to
Designed according to
Designed according to
IEC 61058-1
UL 1283
CSA C22.2 no. 8
Electromagnetic interference (EMI) filters
Application standards
Application standards where the product can be used
Organization
Design
Standard
Description
Suitable for applications acc.
IEC/UL 62368-1
Audio/video, information and communication technology equipment – Part
1: Safety requirements
Compliances
The product complies with following Guide Lines
Identification
Details
Initiator
Description
SCHURTER AG
The CE marking declares that the product complies with the applicable
requirements laid down in the harmonisation of Community legislation on
its affixing in accordance with EU Regulation 765/2008.
SCHURTER AG
The UKCA marking declares that the product complies with the applicable
requirements laid down in the British Amendment of Regulation (EC)
765/2008.
SCHURTER AG
SCHURTER AG
SCHURTER AG
Directive RoHS 2011/65/EU, Amendment (EU) 2015/863
The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March
2007. It is similar to the EU directive RoHS.
On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration,
Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as
“REACH”) entered into force.
Dimension [mm]
Case PI
max. 90
max. 65.3
max. 50.3
11.4
27
6.3×0.8
(5x)
27
max. 85.5
0.3
75
1)
2)
6.3
1) Line, 2) Load
2
EMC Products
1-Phase Line Filters
FMAB HV
Case UB
max. 90
max. 51
27
27
max. 65.3
6.3×0.8
(5x)
max. 85.5
0.3
75
1)
2)
6.3
1) Line, 2) Load
Case PH
max. 70
max. 47
45
max. 23
10.5
17
10.5
6.3×0.8
(5x)
1)
2)
ø 5.3
1) Line, 2) Load
3
EMC Products
1-Phase Line Filters
FMAB HV
Case PG
max. 58
max. 35.5
32.5
max. 24.8
9.5
15.8
9.5
6.3×0.8
(5x)
1)
2)
ø 5.3
1) Line, 2) Load
Diagrams
Standard Version or medical M80
Medical Version (M5)
1)
2)
1)
2)
1) Line
2) Load
1) Line
2) Load
4
EMC Products
1-Phase Line Filters
FMAB HV
. . . . . 0.1/100
Ω
differential mode
……….. 100/0.1
Ω
differential mode
– – – – 50
Ω
differential mode _____ 50
Ω
common mode
Attenuation Loss
Standard version
4 A
1 A
8 A
6 A
10 A
12 A
16 A
20 A
3 A
Medical version
(M5)
4 A
3 A
8 A
1 A
6 A
All Variants
Rated Filter-Type
current
T
e
rminal
Lea-
kage
Ri
Power
Loss
Weight
[g]
Housing
Packa- Order
Number
ging
[A]
[mA]
[m
Ω
]
[W]
[ST]
1
3
Standard version
Standard version
Standard version
Standard version
Standard version
Industrial version
Quick connect terminal 6.3 x 0.8 mm
Quick connect terminal 6.3 x 0.8 mm
Quick connect terminal 6.3 x 0.8 mm
Quick connect terminal 6.3 x 0.8 mm
Quick connect terminal 6.3 x 0.8 mm
Quick connect terminal 6.3 x 0.8 mm
0.5
0.5
0.5
0.5
0.5
1
560
83
1
7
2
g
PG
PH
PH
PH
PI
20
15
15
15
10
10
1.5
1.7
2.4
3.8
4.6
10
4
g
10
8
g
10
9
g
19
0
g
20
0
g
4
53
█
█
6
32.5
29.2
22.8
8
10
PI
5
EMC Products
1-Phase Line Filters
FMAB HV
Rated Filter-Type
current
T
e
rminal
Lea-
kage
Ri
Power
Loss
Weight
[g]
Housing
Packa- Order
Number
ging
[A]
[mA]
[m
Ω
]
[W]
[ST]
12
16
20
1
Industrial version
Industrial version
Industrial version
Medical (M5)
Medical (M5)
Medical (M5)
Medical (M5)
Medical (M5)
Medical (M5)
Medical (M5)
Medical (M5)
Medical (M5)
Medical (M80)
Medical (M80)
Medical (M80)
Medical (M80)
Medical (M80)
Medical (M80)
Medical (M80)
Medical (M80)
Medical (M80)
Quick connect terminal 6.3 x 0.8 mm
Quick connect terminal 6.3 x 0.8 mm
Quick connect terminal 6.3 x 0.8 mm
Quick connect terminal 6.3 x 0.8 mm
Quick connect terminal 6.3 x 0.8 mm
Quick connect terminal 6.3 x 0.8 mm
Quick connect terminal 6.3 x 0.8 mm
Quick connect terminal 6.3 x 0.8 mm
Quick connect terminal 6.3 x 0.8 mm
Quick connect terminal 6.3 x 0.8 mm
Quick connect terminal 6.3 x 0.8 mm
Quick connect terminal 6.3 x 0.8 mm
Quick connect terminal 6.3 x 0.8 mm
Quick connect terminal 6.3 x 0.8 mm
Quick connect terminal 6.3 x 0.8 mm
Quick connect terminal 6.3 x 0.8 mm
Quick connect terminal 6.3 x 0.8 mm
Quick connect terminal 6.3 x 0.8 mm
Quick connect terminal 6.3 x 0.8 mm
Quick connect terminal 6.3 x 0.8 mm
Quick connect terminal 6.3 x 0.8 mm
1
13.2
7.2
8
3.8
3.7
4.8
1
20
1
g
30
8
g
32
2
g
7
2
g
PI
UB
UB
PG
PH
PH
PH
PI
10
10
10
20
15
15
15
10
10
10
10
10
20
15
15
15
10
10
10
10
10
█
1
1
0.005
0.005
0.005
0.005
0.005
0.005
0.005
0.005
0.005
0.08
0.08
0.08
0.08
0.08
0.08
0.08
0.08
0.08
560
83
3
1.5
1.7
2.4
3.8
4.6
3.8
3.7
4.8
1
10
4
g
10
8
g
10
9
g
19
0
g
20
0
g
20
1
g
30
8
g
32
2
g
7
2
g
4
53
6
32.5
29.2
22.8
13.2
7.2
8
8
10
12
16
20
1
PI
PI
UB
UB
PG
PH
PH
PH
PI
560
83
3
1.5
1.7
2.4
3.8
4.6
3.8
3.7
4.8
10
4
g
10
8
g
10
9
g
19
0
g
20
0
g
20
1
g
30
8
g
32
2
g
4
53
6
32.5
29.2
22.8
13.2
7.2
8
8
10
12
16
20
PI
PI
UB
UB
█
Most Popula
r
.
Availability for all products can be searched real-time:
https://www.schurter.com/en/Stock-Check/Stock-Check-SCHURTER
Accessories
Description
Mounting accessory for compact 1- and 3-phase filters
The specifications, descriptions and illustrations indicated in this document are based on current
information. All content is subject to modifications and amendments. Information furnished is believed
to be accurate and reliable. Howeve
r
,
u
sers should independently evaluate the suitability and test each
product selected for their own applications.
6
EMC Products