SCHURTER-FMBB-37MC-1040
| Part # | SCHURTER-FMBB-37MC-1040 |
| Download | SCHURTER-FMBB-37MC-1040 |
1-Phase Line Filters
FMBB EP
AC Filter 2-Stage, excellent Attenuation
Case MF
Case ME
See below:
Approvals and Compliances
Description
Characteristics
– Line filter in standard and medical version
– 2 stage
– Designed for current applications of 1 – 36 A
– Protection against interference voltage from the mains
Possible interferences generated in the equipment are strongly attenu-
ated
– Compact design
– Very light due to partial potting
– Especially designed for industrial applications such as: Frequency Con-
verters, Stepper Motor Drives, UPS-Systems, Inverters
– Suitable for use in equipment according to IEC/UL 62368-1
Suitable for use in medical equipment according to IEC/UL 60601-1 (1
MOO
P
, 1
M
OPP)
Unique Selling Proposition
– Excellent differential and common-mode attenuation
– Broad band attenuation
– Completely closed steel housing
– Wide temperature range
References
Weblinks
T
e
chnical Data
Ratings IEC
Ratings UL/CSA
1 – 3
6
A @
T
a
4
0 °C / 25
0
V
AC; 5
0
H
z
1 – 3
6
A @
T
a
4
0 °C / 125/25
0
V
AC;
6
0
H
z
standard < 0.
5
m
A (25
0
V /
5
0
H
z)
medical (M5) < 5 µA resp. (M80) < 80
µA (250 V / 50 Hz)
Line Filter
MTBF
Standard and Medical Version, IEC
60939, UL 60939-3, CSA C22.2 no. 8
> 200’00
0
h
a
cc. to MIL-HB-217 F
Leakage Current
Dielectric Strength
1.
7
k
VDC between L-N
2.
7
k
VDC between L/N-PE
T
e
st voltage (
2
s
ec)
Allowable Operation
T
e
mpe-
rature
-4
0
°
C to 10
0
°
C
Climatic Category
IP-Protection
Protection Class
40/100/21 acc. to IEC 60068-1
rear-side IP20 IEC 60529
Suitable for appliances with protection
class I acc. to IEC 61140
Quick connect terminal 6.3 x 0.8 mm
Bolt and nut M4
T
e
rminal
Material
Nickel plated steel
Approvals and Compliances
Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in
Details about
SCHURTER products are designed for use in industrial environments. They have approvals from independent testing bodies according to national
and international standards. Products with specific characteristics and requirements such as required in the automotive sector according to IATF
16949, medical technology according to ISO 13485 or in the aerospace industry can be offered exclusively with customer-specific, individual agree-
ments by SCHURTER.
1
EMC Products
1-Phase Line Filters
FMBB EP
Approvals
The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products.
Approval Reference
T
y
pe: FMBB EP
Approval Logo
Certificates
Certification Body
Description
VDE
Certificate Number: 40051449
UL
UR File Number: E495089
Product standards
Product standards that are referenced
Organization
Design
Standard
Description
Designed according to
IEC 60939
Passive filters for suppressing electromagnetic interference
Designed according to
Designed according to
Designed according to
Designed according to
IEC 60127-6
Miniature fuses. Part 6. Fuse-holders for miniature fuse-links
Electromagnetic interference filters
UL 60939-3
CSA C22.2 no. 42
CSA C22.2 no. 8
General Use Receptacles, Attachment Plugs, and Similar Wiring Devices
Electromagnetic interference (EMI) filters
Application standards
Application standards where the product can be used
Organization
Design
Standard
Description
Suitable for applications acc.
IEC/UL 62368-1
Audio/video, information and communication technology equipment – Part
1: Safety requirements
Suitable for applications acc.
IEC 60601-1
Medical electrical equipment – Part 1: General requirements for basic
safety and essential performance
Compliances
The product complies with following Guide Lines
Identification
Details
Initiator
Description
SCHURTER AG
The CE marking declares that the product complies with the applicable
requirements laid down in the harmonisation of Community legislation on
its affixing in accordance with EU Regulation 765/2008.
SCHURTER AG
The UKCA marking declares that the product complies with the applicable
requirements laid down in the British Amendment of Regulation (EC)
765/2008.
SCHURTER AG
SCHURTER AG
SCHURTER AG
Directive RoHS 2011/65/EU, Amendment (EU) 2015/863
The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March
2007. It is similar to the EU directive RoHS.
On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration,
Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as
“REACH”) entered into force.
SCHURTER AG
Suitable for use in medical equipment according to IEC/UL 60601-1 (1
MOO
P
, 1
M
OPP)
2
EMC Products
1-Phase Line Filters
FMBB EP
Dimension [mm]
Case 09 with quick connect terminals
max. 77
max. 52
max. 46
17.5
27
6±.
4
±±.5
6.ꢀx±.8
(5x)
1)
2)
1) Line
2) Load
Case MB with bolt and nut M4
max. 160
max. 131
max. 58
15.2
27
4)
5)
max. 156
0.5
144
0.5
140
3)
4)
1)
2)
1) Line
2) Load
3) Nut torque 0.8…1 Nm, keep lock-nut fastened
4) Lock-nut do not unscrew
5) PE: M4x16, 1.2…1.5 Nm, keep lock-nut fastened
3
EMC Products
1-Phase Line Filters
FMBB EP
Case MC with quick connect terminals
max. 90
max. 66
max. 51
21
27
0.5
75
6.3×0.8
(5x)
1)
2)
1) Line
2) Load
Case UB with quick connect terminals
max. 90
max. 66
max. 51
11.4
27
10.4
0.5
75
6.3×0.8
(5x)
1)
2)
1) Line
2) Load
4
EMC Products
1-Phase Line Filters
FMBB EP
Case ME with quick connect terminals
max. 52
max. 112
max. 87
27
12
max. 115
1±4.5
±±.5
97.5
±±.5
6.3x±.8
(5x)
1)
2)
1) Line
2) Load
Case MF with bolt and nut M4
max. 85
40
max. 130
max. 98
max. 120
0.3
0.3
109
4.4
(4x)
3)
4)
5)
1)
2)
1) Line
2) Load
3) Nut torque 0.8…1 Nm, keep lock-nut fastened
4) Lock-nut do not unscrew
5) PE: M4x16, 1.2…1.5 Nm, keep lock-nut fastened
5
EMC Products
1-Phase Line Filters
FMBB EP
Diagrams
Medical M80
Standard and low leakage current
1)
2)
1)
2)
1) Line, 2) Load
Medical M5
1) Line, 2) Load
1)
2)
. . . . . 0.1/100
Ω
differential mode
……….. 100/0.1
Ω
differential mode
– – – – 50
Ω
differential mode _____ 50
Ω
common mode
Attenuation Loss
Standard version
6A
3A
1A
36 A
30 A
20 A
16 A
12 A
10 A
6
EMC Products
1-Phase Line Filters
FMBB EP
Medical version
(M5)
6 A
3 A
1 A
30 A
20 A
16 A
12 A
10 A
36 A
Medical version
(M80)
36 A
30 A
20 A
16 A
12 A
10 A
6 A
3 A
1 A
7
EMC Products
1-Phase Line Filters
FMBB EP
Low leakage current version
6 A
3 A
1 A
30 A
20 A
16 A
12 A
36 A
10 A
All Variants
Rated Filter-Type
current
T
e
rminal
Lea-
kage
Ri
Power
Loss
Weight
[g]
Housing
Packa- Order
Number
ging
[A]
[mA]
[m
Ω
]
[W]
[ST]
1
Standard version
Quick connect terminal 6.3 x 0.8 mm
Quick connect terminal 6.3 x 0.8 mm
Quick connect terminal 6.3 x 0.8 mm
Quick connect terminal 6.3 x 0.8 mm
Quick connect terminal 6.3 x 0.8 mm
Quick connect terminal 6.3 x 0.8 mm
Quick connect terminal 6.3 x 0.8 mm
Bolt and nut M4
1.47
1.47
1.47
6.91
3.14
3.14
3.14
3.14
3.14
0.15
0.15
0.15
0.15
0.15
0.15
0.15
0.15
0.15
0.005
0.005
0.005
0.005
0.005
0.005
0.005
600
168
40
1.2
3
12
5
g
12
8
g
13
3
g
19
8
g
20
1
g
26
5
g
39
0
g
85
5
g
89
0
g
12
5
g
12
8
g
13
3
g
19
8
g
20
1
g
26
5
g
39
0
g
85
5
g
89
0
g
12
5
g
12
8
g
13
3
g
19
8
g
20
1
g
26
5
g
39
0
g
09
09
15
15
15
10
10
10
5
3
Standard version
6
Standard version
2.88
4.4
4.15
4.1
4.8
10.8
10.4
1.2
3
09
█
10
12
16
20
30
36
1
Standard version
8.6
6.2
8.0
6
MC
MC
UB
ME
MF
MB
09
Standard version
█
█
Standard version
Standard version
Standard version
6
3
Standard version
Bolt and nut M4
4.2
600
168
40
4
Low leakage current
Low leakage current
Low leakage current
Low leakage current
Low leakage current
Low leakage current
Low leakage current
Low leakage current
Low leakage current
Medical Version (M5)
Medical Version (M5)
Medical Version (M5)
Medical Version (M5)
Medical Version (M5)
Medical Version (M5)
Medical Version (M5)
Quick connect terminal 6.3 x 0.8 mm
Quick connect terminal 6.3 x 0.8 mm
Quick connect terminal 6.3 x 0.8 mm
Quick connect terminal 6.3 x 0.8 mm
Quick connect terminal 6.3 x 0.8 mm
Quick connect terminal 6.3 x 0.8 mm
Quick connect terminal 6.3 x 0.8 mm
Bolt and nut M4
15
15
15
10
10
10
5
3
09
6
2.88
4.4
4.15
4.1
4.8
10.8
10.4
1.2
3
09
10
12
16
20
30
36
1
8.6
6.2
8.0
6
MC
MC
UB
ME
MF
MB
09
6
3
Bolt and nut M4
4.2
600
168
40
4
Quick connect terminal 6.3 x 0.8 mm
Quick connect terminal 6.3 x 0.8 mm
Quick connect terminal 6.3 x 0.8 mm
Quick connect terminal 6.3 x 0.8 mm
Quick connect terminal 6.3 x 0.8 mm
Quick connect terminal 6.3 x 0.8 mm
Quick connect terminal 6.3 x 0.8 mm
15
15
15
10
10
10
5
3
09
6
2.88
4.4
4.15
4.1
4.8
09
10
12
16
20
8.6
6.2
8.0
6
MC
MC
UB
ME
8
EMC Products
1-Phase Line Filters
FMBB EP
Rated Filter-Type
current
T
e
rminal
Lea-
kage
Ri
Power
Loss
Weight
[g]
Housing
Packa- Order
Number
ging
[A]
[mA]
[m
Ω
]
[W]
[ST]
30
36
1
Medical Version (M5)
Bolt and nut M4
0.005
0.005
0.073
0.073
0.073
0.073
0.073
0.073
0.073
0.073
0.073
6
10.8
10.4
1.2
85
5
g
89
0
g
12
5
g
12
8
g
13
3
g
19
8
g
20
1
g
26
5
g
39
0
g
85
5
g
89
0
g
MF
MB
09
3
4
Medical Version (M5)
Medical Version (M80)
Medical Version (M80)
Medical Version (M80)
Medical Version (M80)
Medical Version (M80)
Medical Version (M80)
Medical Version (M80)
Medical Version (M80)
Medical Version (M80)
Bolt and nut M4
4.2
600
168
40
Quick connect terminal 6.3 x 0.8 mm
Quick connect terminal 6.3 x 0.8 mm
Quick connect terminal 6.3 x 0.8 mm
Quick connect terminal 6.3 x 0.8 mm
Quick connect terminal 6.3 x 0.8 mm
Quick connect terminal 6.3 x 0.8 mm
Quick connect terminal 6.3 x 0.8 mm
Bolt and nut M4
15
15
15
10
10
10
5
3
3
09
6
2.88
4.4
09
10
12
16
20
30
36
8.6
6.2
8.0
6
MC
MC
UB
ME
MF
MB
4.15
4.1
4.8
6
10.8
10.4
3
Bolt and nut M4
4.2
4
█
Most Popula
r
.
Availability for all products can be searched real-time:
https://www.schurter.com/en/Stock-Check/Stock-Check-SCHURTER
Leakage current according IEC 60939-1
20A, 30A and 36A medical filter M5 and M80, are only suitable for medical equipment intended for permanently connection to the mains.
Accessories
Description
Mounting accessory for compact 1- and 3-phase filters
The specifications, descriptions and illustrations indicated in this document are based on current
information. All content is subject to modifications and amendments. Information furnished is believed
to be accurate and reliable. Howeve
r
,
u
sers should independently evaluate the suitability and test each
9
EMC Products
product selected for their own applications.