SCHURTER-FPBB-U3TI-0690
| Part # | SCHURTER-FPBB-U3TI-0690 |
| Download | SCHURTER-FPBB-U3TI-0690 |
1-Phase Line Filters
FPBB RAIL
AC/DC Filter 2-Stage, DIN Rail Mounting, Overcurrent and Overvoltage Protection
Housing RI with Circuit Breaker
Housing RI with Fuseholder
Housing RI
See below:
Approvals and Compliances
Description
Characteristics
– Single-phase line filter in standard and medical versions
– 2-Stages filter
– Protection against interference voltage from the mains
Possible interferences generated in the equipment are strongly attenu-
ated
– Very high attenuation
– broadband
– Fuseholder
– Thermal circuit breaker
– Surge protection
– Especially designed for electric switch and control cabinets
– Suitable for use in equipment according to IEC/UL 62368-1
– Suitable for use in medical equipment according to IEC/UL 60601-1 (1
MOOP)
– Suitable for medical equipment intended for permanently connection
to the mains
Unique Selling Proposition
– Slim filter for DIN-rail mounting or chassis mounting
– With fuse holder or circuit breaker for equipment
– With overvoltage protection
Weblinks
– Quick wiring with cage clamp terminals
T
e
chnical Data
Ratings IEC
1 – 1
6
A @
T
a
4
0 °C / 25
0
V
AC; 5
0
H
z
48/250 VDC
1 – 1
6
A @
T
a
4
0 °C / 125/25
0
V
AC;
6
0
H
z
48/250 VDC
standard <
1
m
A (25
0
V /
5
0
H
z)
1.
7
k
VDC between L-N
2.
7
k
VDC between L/N-PE
T
e
st voltage (
2
s
ec)
-4
0
°
C to 10
0
°
C
Circuit Breakers
Acc. IEC/EN 60934, UL 1077, CSA
22.2 no. 235
3 – 15 A
Short circuit capacity Icn:
2000 A
Climatic Category 05 / 060 / 21 acc.
to IEC 60068-1
1-pole, Shocksafe category PC2 acc. to
IEC 60127-6
for fuse-links 5 x 2
0
m
m
Ratings UL/CSA
Leakage Current
Dielectric Strength
Fuseholder
Allowable Operation
T
e
mpe-
rature
Climatic Category
IP-Protection
Rated Power Acceptance @
Ta
2
3 °C
Power Acceptance @
T
a >
23°C
5 x 20: 2.
5
W
40/100/21 acc. to IEC 60068-1
IP20 IEC 60529
Suitable for appliances with protection
class I acc. to IEC 61140
Spring cage terminals ,
Admissible power acceptance at higher
ambient temperature see derating cur-
ves
Climatic Category 40 / 085 / 21 acc.
to IEC 60068-1
320 VAC , 420 VDC , 0.4 W
Standard and Industrial Version, IEC
60939, UL 60939-3, CSA C22.2 no. 8
Protection Class
T
e
rminal
Material
0.2 – 2.5 mm², 24 – 12 AWG
Plastics, black, UL 94V-0
Surge protection
Line Filter
MTBF
> 200’00
0
h
a
cc. to MIL-HB-217 F
Approvals and Compliances
Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in
Details about
SCHURTER products are designed for use in industrial environments. They have approvals from independent testing bodies according to national
and international standards. Products with specific characteristics and requirements such as required in the automotive sector according to IATF
16949, medical technology according to ISO 13485 or in the aerospace industry can be offered exclusively with customer-specific, individual agree-
ments by SCHURTER.
1
EMC Products
1-Phase Line Filters
FPBB RAIL
Approvals
The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products.
Approval Reference
T
y
pe: FPBB Rail
Approval Logo
Certificates
Certification Body
Description
VDE
Certificate Number: 40047767
UL
UR File Number: E495089
Product standards
Product standards that are referenced
Organization
Design
Standard
Description
Designed according to
IEC 60320-1
Appliance couplers for household and similar general purposes
Designed according to
Designed according to
Designed according to
Designed according to
Designed according to
Designed according to
IEC 60939
Passive filters for suppressing electromagnetic interference
Miniature fuses. Part 6. Fuse-holders for miniature fuse-links
Standard for Attachment Plugs and Receptacles
IEC 60127-6
UL 498
UL 60939-3
CSA C22.2 no. 42
CSA C22.2 no. 8
Electromagnetic interference filters
General Use Receptacles, Attachment Plugs, and Similar Wiring Devices
Electromagnetic interference (EMI) filters
Application standards
Application standards where the product can be used
Organization
Design
Standard
Description
Suitable for applications acc.
IEC/UL 62368-1
Audio/video, information and communication technology equipment – Part
1: Safety requirements
Suitable for applications acc.
IEC 60601-1
Medical electrical equipment – Part 1: General requirements for basic
safety and essential performance
Compliances
The product complies with following Guide Lines
Identification
Details
Initiator
Description
SCHURTER AG
The CE marking declares that the product complies with the applicable
requirements laid down in the harmonisation of Community legislation on
its affixing in accordance with EU Regulation 765/2008.
SCHURTER AG
The UKCA marking declares that the product complies with the applicable
requirements laid down in the British Amendment of Regulation (EC)
765/2008.
SCHURTER AG
SCHURTER AG
SCHURTER AG
Directive RoHS 2011/65/EU, Amendment (EU) 2015/863
The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March
2007. It is similar to the EU directive RoHS.
On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration,
Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as
“REACH”) entered into force.
SCHURTER AG
Suitable for use in medical equipment according to IEC/UL 60601-1 (1
MOO
P
, 1
M
OPP)
2
EMC Products
1-Phase Line Filters
FPBB RAIL
Dimension [mm]
Housing RI
85
25
10.3
Ø
Housing TI
85
25
10.3
4.9
Ø
Ø
92
104
3
EMC Products
1-Phase Line Filters
FPBB RAIL
Diagrams
Diagram S6
Diagram S5
CB
L
L
F
L
L
L
L‘
L
L‘
R
VDR
Cx
Cx
R
VDR
Cx
Cx
N
N‘
N
N‘
1) Line, 2) Load
1) Line, 2) Load
VDR only for versions with overvoltage protection
VDR only for versions with overvoltage protection
Diagram S4
Diagram S3
L
L
CB
L
L‘
L
L
L
L‘
Cy
R
VDR
Cx
Cx
R
VDR
Cx
Cx
E
Cy
N
N‘
N
N‘
1) Line, 2) Load
1) Line, 2) Load
VDR only for versions with overvoltage protection
VDR only for versions with overvoltage protection
Diagram S2
Diagram S1
L
L
L
L
F
L
L‘
L
L‘
Cy
Cy
R
VDR
Cx
Cx
E
R
VDR
Cx
Cx
E
Cy
Cy
N
N‘
N
N‘
1) Line, 2) Load
1) Line, 2) Load
VDR only for versions with overvoltage protection
VDR only for versions with overvoltage protection
– – – – 50
Ω
differential mode _____ 50
Ω
common mode
Attenuation Loss
Standard version
16 A
12 A
10 A
6 A
3 A
1 A
4
EMC Products
1-Phase Line Filters
FPBB RAIL
Medical version
(M5)
16 A
12 A
10 A
6 A
3 A
1 A
Medical version
(M80)
16 A
12 A
10 A
6 A
3 A
1 A
All Variants
Rated
current
Rated vol-
tage
Rated vol-
tage
Filter-Type
Lea-
kage
Current
Ri
Power
Loss
Fusehol-
der
Circuit-
breaker for
equipment
Surge protection
Dia-
gram
Housing
Weight
Order Number
[A]
[VAC]
[VDC]
[mA]
[m
Ω
]
[W]
[g]
1
250
250
Standard
version
0.5
780
1.3
l
–
–
S2
S1
S1
S2
S1
S2
S4
RI
RI
RI
RI
TI
TI
TI
115
1
1
1
1
1
1
250
250
250
250
250
250
250
250
250
250
250
250
Standard
version
0.5
0.5
770
770
780
770
780
770
1.3
1.3
1.3
1.3
1.3
1.3
115
115
115
115
115
115
Standard
version
VDR
VDR
–
Standard
version
0.5
l
l
█
Standard
version
0.5
Standard
version
0.5
VDR
–
Medical
Version
(M5)
0.005
1
3
250
250
250
250
Medical
Version
(M5)
0.005
0.5
780
88
1.3
1.3
l
–
–
S5
S1
TI
RI
115
115
Standard
version
5
EMC Products
1-Phase Line Filters
FPBB RAIL
Rated
current
Rated vol-
tage
Rated vol-
tage
Filter-Type
Lea-
kage
Current
Ri
Power
Loss
Fusehol-
der
Circuit-
breaker for
equipment
Surge protection
Dia-
gram
Housing
Weight
Order Number
[A]
[VAC]
[VDC]
[mA]
[m
Ω
]
[W]
[g]
3
240
48
Standard
version
0.5
250
1.3
l
–
S3
S1
S2
S3
S1
S3
S2
S4
RI
RI
RI
RI
TI
TI
TI
TI
120
3
3
3
3
3
3
3
250
250
240
250
240
250
250
250
250
48
Standard
version
0.5
0.5
88
98
1.3
1.3
1.3
1.3
1.3
1.3
1.3
VDR
VDR
VDR
–
115
115
120
115
120
115
115
Standard
version
l
█
█
█
Standard
version
0.5
250
88
l
l
250
48
Standard
version
0.5
Standard
version
0.5
250
98
VDR
VDR
–
250
250
Standard
version
0.5
l
l
Medical
Version
(M5)
0.005
88
3
250
250
Medical
Version
(M5)
0.005
98
1.3
–
S5
TI
115
6
6
6
6
6
6
6
6
6
250
250
250
250
240
250
240
250
250
250
250
250
250
48
Standard
version
0.5
0.5
30
40
30
40
60
30
60
40
30
1.73
1.73
1.73
1.73
1.73
1.73
1.73
1.73
1.73
–
S1
S2
S1
S2
S3
S1
S3
S2
S4
RI
RI
RI
RI
RI
TI
TI
TI
TI
115
115
115
115
120
115
120
115
115
█
█
Standard
version
l
l
–
Standard
version
0.5
VDR
VDR
VDR
–
Standard
version
0.5
█
█
Standard
version
0.5
l
l
250
48
Standard
version
0.5
Standard
version
0.5
VDR
VDR
–
250
250
Standard
version
0.5
l
l
Medical
Version
(M5)
0.005
6
250
250
Medical
Version
(M5)
0.005
40
1.73
–
S5
TI
115
10
10
10
10
10
10
10
10
10
250
240
250
250
240
250
250
240
250
250
48
Standard
version
0.5
0.5
25
30
25
35
30
25
35
30
25
2.64
2.64
2.64
2.64
2.64
2.64
2.64
2.64
2.64
–
S1
S3
S1
S2
S3
S1
S2
S3
S4
RI
RI
RI
RI
RI
TI
TI
TI
TI
115
120
115
115
120
115
115
120
115
█
█
Standard
version
l
l
l
–
250
250
48
Standard
version
0.5
VDR
VDR
VDR
–
Standard
version
0.5
l
l
Standard
version
0.5
█
█
250
250
48
Standard
version
0.5
Standard
version
0.5
VDR
VDR
–
Standard
version
0.5
250
Medical
Version
(M5)
0.005
10
250
250
Medical
Version
(M5)
0.005
35
2.64
l
–
S5
TI
115
12
12
12
12
250
250
240
250
250
250
48
Standard
version
0.5
0.5
0.5
0.5
12
12
25
12
1.6
1.6
1.6
1.6
–
S1
S1
S3
S1
RI
RI
RI
TI
115
115
120
115
Standard
version
VDR
VDR
–
Standard
version
l
█
250
Standard
version
6
EMC Products
1-Phase Line Filters
FPBB RAIL
Rated
current
Rated vol-
tage
Rated vol-
tage
Filter-Type
Lea-
kage
Current
Ri
Power
Loss
Fusehol-
der
Circuit-
breaker for
equipment
Surge protection
Dia-
gram
Housing
Weight
Order Number
[A]
[VAC]
[VDC]
[mA]
[m
Ω
]
[W]
[g]
12
240
48
Standard
version
0.5
25
1.6
l
VDR
–
S3
S4
TI
TI
120
12
250
250
Medical
Version
(M5)
0.005
12
1.6
115
15
15
16
16
16
16
240
240
250
250
250
250
32
32
Standard
version
0.5
0.5
20
20
8
1.55
1.55
1.55
1.55
1.55
1.55
l
l
VDR
VDR
–
S3
S3
S1
S1
S1
S4
RI
TI
RI
RI
TI
TI
120
120
115
115
115
115
Standard
version
250
250
250
250
Standard
version
0.5
█
█
Standard
version
0.5
8
VDR
–
Standard
version
0.5
8
Medical
Version
(M5)
0.005
8
–
█
Most Popula
r
.
Availability for all products can be searched real-time:
https://www.schurter.com/en/Stock-Check/Stock-Check-SCHURTER
20 Pcs
Packaging unit
The specifications, descriptions and illustrations indicated in this document are based on current
information. All content is subject to modifications and amendments. Information furnished is believed
to be accurate and reliable. Howeve
r
,
u
sers should independently evaluate the suitability and test each
product selected for their own applications.
7