Sensata-Tech-S2-12E
| Part # | Sensata-Tech-S2-12E |
| Download | Sensata-Tech-S2-12E |
|
S2 RELAY SERIES
AXIAL STYLE REED RELAY
The S2 reed relay series from Cynergy3 has been developed for
applications where PCB mounting is not possible.
The relay can be mounted using a variety of methods and orientations
to suit particular applications. The terminal pins are flexible enough to
allow bending for assembly into equipment.
Available with either a 10W or 50W contact in a pressurized reed switch
or a 100VA contact in a vacuum reed switch.
Features
• Variable mounting options
• 10W, 50W and 100VA contact options
• Reliable reed switch contacts
Please refer to this document for circuit design notes:
SPECIFICATIONS
Contact
Condition
Units
S2-03P
S2-XXP
S2-XXE
Ruthenium
Rhodium
Rhodium
Material
Pressurized
Pressurized
500
Vacuum
1000
Switch Atmosphere
Volts DC
Watts
200
10
Isolation Across Contacts
Switching Power Max.
Switching Power Max.
Switching Voltage DC Max.
Switching Voltage AC Max.
Switching Current DC Max.
Switching Current AC Max
Carry Current Max.
Resistive load
Resistive load
Resistive load
Resistive load
Resistive load
Resistive load
50
VA
70
100
350
Volts DC
200
140
250
250
1
350
Volts AC RMS
mA DC
300
300
700
1000
1000
2.5
mA AC RMS
Amps DC/AC RMS
Pico Farad (pF)
Milliohms (m
Ω
)
Ohms (Ω)
500
2.5
Open
0.3
0.5
0.5
Contact Capacitance Max.
Nominal coil voltage
100
10E10
100
100
Initial Contact Resistance Max.
Insulation Resistance
10E10
10E10
Hot switching
resistive load
10E7
(12V DC, 4mA)
10E6
(350V DC, 1mA)
10E7
(500V DC, 1mA)
Operations 50% duty cycle
Operations 50% duty cycle
Lifetime Operations
Dry switching
10E8
3V
10E9
12V
9
Coil
5V
3.7
1
24V
19
20°C
20°C
20°C
20°C
20°C
Volts DC
Volts DC
2.25
0.5
Must Operate Voltage
Must Release Voltage
Operate Time Inc Bounce
Release Time Inc Bounce
Resistance
2
3
Milliseconds
Milliseconds
Ohms
0.1
1.0
0.5
160
1
11
0.07
250
0.5
0.5
1000
1000
Note. The operate / release voltage and coil resistance will change at a rate of 0.4% per degree C. Values are stated at room temperature (20 degrees C)
Page 1
Copyright © 2021 Sensata Technologies, Inc.
Condition
Units
Volts DC
°C
S2-03P
S2-XXP
1000
S2-XXE
Relay
Isolation Contact/Coil Min.
Operating Temperature Range
Storage Temperature Range
-40 to +85
-40 to +125
°C
STANDARD PARTS
Coil Voltage VDC
Switching Power
Isolation VDC
Switch Atmosphere
3
5
10W
70VA
200
500
Pressurized
Pressurized
Pressurized
Pressurized
Vacuum
S2-03P
S2-05P
S2-12P
S2-24P
S2-05E
S2-12E
S2-24E
12
24
5
70VA
500
70VA
500
100VA
100VA
100VA
1000
1000
1000
12
24
Vacuum
Vacuum
Custom versions can be made for particular applications. Please contact Sensata with your requirements.
DIMENSIONS
Page 2
Made in the UK
Sensata Technologies, Inc. (“Sensata”) data sheets are solely intended to assist designers (“Buyers”) who are developing systems that
incorporate Sensata products (also referred to herein as “components”). Buyer understands and agrees that Buyer remains responsible
for using its independent analysis, evaluation and judgment in designing Buyer’s systems and products. Sensata data sheets have
been created using standard laboratory conditions and engineering practices. Sensata has not conducted any testing other than that
specifically described in the published documentation for a particular data sheet. Sensata may make corrections, enhancements,
improvements and other changes to its data sheets or components without notice.
CONTACT US
+44 (0)1202 897969
Cynergy3 Components Ltd.
7 Cobham Road,
Buyers are authorized to use Sensata data sheets with the Sensata component(s) identified in each particular data sheet. HOWEVER, NO
OTHER LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE TO ANY OTHER SENSATA INTELLECTUAL PROPERTY RIGHT, AND
NO LICENSE TO ANY THIRD PARTY TECHNOLOGY OR INTELLECTUAL PROPERTY RIGHT, IS GRANTED HEREIN. SENSATA DATA SHEETS
ARE PROVIDED “AS IS”. SENSATA MAKES NO WARRANTIES OR REPRESENTATIONS WITH REGARD TO THE DATA SHEETS OR USE
OF THE DATA SHEETS, EXPRESS, IMPLIED OR STATUTOR
Y
,
I
NCLUDING ACCURACY OR COMPLETENESS. SENSATA DISCLAIMS
ANY WARRANTY OF TITLE AND ANY IMPLIED WARRANTIES OF MERCHANTABILIT
Y
,
F
ITNESS FOR A PARTICULAR PURPOSE, QUIET
ENJOYMENT, QUIET POSSESSION, AND NON-INFRINGEMENT OF ANY THIRD PARTY INTELLECTUAL PROPERTY RIGHTS WITH REGARD
TO SENSATA DATA SHEETS OR USE THEREOF.
Ferndown Industrial Estate,
Wimborne, Dorset,
BH21 7PE, United Kingdom
All products are sold subject to Sensata’s terms and conditions of sale supplied at
www.sensata.com
SENSATA ASSUMES NO LIABILITY
FOR APPLICATIONS ASSISTANCE OR THE DESIGN OF BUYERS’ PRODUCTS. BUYER ACKNOWLEDGES AND AGREES THAT IT IS SOLELY
RESPONSIBLE FOR COMPLIANCE WITH ALL LEGAL, REGULATORY AND SAFETY-RELATED REQUIREMENTS CONCERNING ITS PRODUCTS,
AND ANY USE OF SENSATA COMPONENTS IN ITS APPLICATIONS, NOTWITHSTANDING ANY APPLICATIONS-RELATED INFORMATION
OR SUPPORT THAT MAY BE PROVIDED BY SENSATA.
Mailing Address: Sensata Technologies, Inc., 529 Pleasant Street, Attleboro, MA 02703, USA.
Copyright © 2021 Sensata Technologies, Inc.
ISO9001CERTIFIED
Rev: Cynergy3-s2-v3 03/09/21