Sensata-Tech-S2-24EU

Part #Sensata-Tech-S2-24EU
Download 
Sensata-Tech-S2-24EU
|
S2(UL) SERIES  
UL APPROVED* AXIAL STYLE REED RELAY  
The S2(UL) reed relay series from Cynergy3 has been developed and  
approved by UL for applications where PCB mounting is not possible.  
The relay can be mounted in a variety of methods and orientations to suit  
particular applications. The terminal pins are flexible enough to allow  
bending for assembly into equipment.  
Available with either a 10W or 50W contact in a pressurised reed switch  
or a 100VA contact in a vacuum reed switch.  
Features  
• Variable mounting options  
• 10W, 50W and 100VA contact options  
• Reliable reed switch contacts  
Please refer to this document for circuit design notes:-  
*Consult factory for UL ratings  
These products have been UL approved for use as per pollution degree  
2 classification. If you require further information as to how this may  
affect product usage, please contact c3w_sales@sensata.com  
SPECIFICATIONS  
Conditions  
Units  
S2-03P  
S2-XXP  
Rhodium  
Pressurised  
500  
S2-XXE  
Rhodium  
Vacuum  
1000  
–
Contact  
Ruthenium  
Material  
Pressurised  
Switch atmosphere  
Volts DC  
Watts  
200  
10  
Isolation across contacts  
Switching Power Max.  
Switching Power Max.  
Switching Voltage DC Max.  
Switching Voltage AC Max.  
Switching Current DC Max.  
Switching Current AC Max  
Resistive load  
Resistive load  
Resistive load  
Resistive load  
Resistive load  
Resistive load  
50  
VA  
–
70  
100  
Volts DC  
Volts AC RMS  
mA DC  
200  
140  
250  
250  
1
350  
350  
300  
300  
700  
1000  
1000  
2.5  
mA AC RMS  
500  
Amps DC/AC  
RMS  
2.5  
Carry Current Max.  
open  
Pico Farad (pF)  
0.3  
0.5  
0.5  
Contact capacitance max.  
Initial contact resistance max.  
Insulation resistance  
@Nominal  
coil voltage  
Milliohms (m
Ω
)  
100  
100  
100  
Ohms (Ω)  
10E10  
10E10  
10E10  
Hot switching  
resistive load  
Operations 50%  
duty cycle  
10E7  
(12V DC, 4mA)  
10E6  
(350V DC, 1mA  
10E7  
(500V DC, 1mA  
Lifetime Operations  
Dry switching  
Operations 50%  
duty cycle  
10E8  
10E9  
Page 1  
Copyright © 2021 Sensata Technologies, Inc.  

Conditions  
Units  
S2-03P  
3V  
S2-XXP  
5V  
S2-XXE  
24V  
Contact  
12V  
9
Coil  
@20°C  
@20°C  
@20°C  
@20°C  
@20°C  
Volts DC  
Volts DC  
2.25  
0.5  
3.7  
19  
3
Must Operate Voltage  
Must Release Voltage  
Operate time inc bounce  
Release time inc bounce  
Resistance  
1
2
Milliseconds  
Milliseconds  
Ohms  
0.1  
1.0  
1
11  
0.07  
250  
0.5  
0.5  
1000  
0.5  
1000  
160  
Note. The operate / release voltage and coil resistance will change at a rate of 0.4% per degree C. Values are stated at room temperature (20 degrees C)  
Relay  
Volts DC  
°C  
1000  
Isolation contact/coil  
Operating temp range min.  
Storage temp range  
-40 to +85  
-40 to +125  
°C  
Coil Volts VDC  
Switching Power  
Isolation VDC  
Switch Atmosphere  
Standard Parts  
S2-03PU  
S2-05PU  
S2-12PU  
S2-24PU  
S2-05EU  
3
5
10W  
70VA  
200  
500  
Pressurized  
Pressurized  
Pressurized  
Pressurized  
Vacuum  
12  
24  
5
70VA  
500  
70VA  
500  
100VA  
100VA  
100VA  
1000  
1000  
1000  
12  
24  
Vacuum  
S2-12EU  
Vacuum  
S2-24EU  
Custom versions can be made for particular applications. Please contact Sensata with your requirements.  
DIMENSIONS  
Page 2  
Made in the UK  
Sensata Technologies, Inc. (“Sensata”) data sheets are solely intended to assist designers (“Buyers”) who are developing systems that  
incorporate Sensata products (also referred to herein as “components”). Buyer understands and agrees that Buyer remains responsible  
for using its independent analysis, evaluation and judgment in designing Buyer’s systems and products. Sensata data sheets have  
been created using standard laboratory conditions and engineering practices. Sensata has not conducted any testing other than that  
specifically described in the published documentation for a particular data sheet. Sensata may make corrections, enhancements,  
improvements and other changes to its data sheets or components without notice.  
CONTACT US  
+44 (0)1202 897969  
Cynergy3 Components Ltd.  
7 Cobham Road,  
Buyers are authorized to use Sensata data sheets with the Sensata component(s) identified in each particular data sheet. HOWEVER, NO  
OTHER LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE TO ANY OTHER SENSATA INTELLECTUAL PROPERTY RIGHT, AND  
NO LICENSE TO ANY THIRD PARTY TECHNOLOGY OR INTELLECTUAL PROPERTY RIGHT, IS GRANTED HEREIN. SENSATA DATA SHEETS  
ARE PROVIDED “AS IS”. SENSATA MAKES NO WARRANTIES OR REPRESENTATIONS WITH REGARD TO THE DATA SHEETS OR USE  
OF THE DATA SHEETS, EXPRESS, IMPLIED OR STATUTOR
Y
,
I
NCLUDING ACCURACY OR COMPLETENESS. SENSATA DISCLAIMS  
ANY WARRANTY OF TITLE AND ANY IMPLIED WARRANTIES OF MERCHANTABILIT
Y
,
F
ITNESS FOR A PARTICULAR PURPOSE, QUIET  
ENJOYMENT, QUIET POSSESSION, AND NON-INFRINGEMENT OF ANY THIRD PARTY INTELLECTUAL PROPERTY RIGHTS WITH REGARD  
TO SENSATA DATA SHEETS OR USE THEREOF.  
Ferndown Industrial Estate,  
Wimborne, Dorset,  
BH21 7PE, United Kingdom  
All products are sold subject to Sensata’s terms and conditions of sale supplied at

SENSATA ASSUMES NO LIABILITY  
FOR APPLICATIONS ASSISTANCE OR THE DESIGN OF BUYERS’ PRODUCTS. BUYER ACKNOWLEDGES AND AGREES THAT IT IS SOLELY  
RESPONSIBLE FOR COMPLIANCE WITH ALL LEGAL, REGULATORY AND SAFETY-RELATED REQUIREMENTS CONCERNING ITS PRODUCTS,  
AND ANY USE OF SENSATA COMPONENTS IN ITS APPLICATIONS, NOTWITHSTANDING ANY APPLICATIONS-RELATED INFORMATION  
OR SUPPORT THAT MAY BE PROVIDED BY SENSATA.  
Mailing Address: Sensata Technologies, Inc., 529 Pleasant Street, Attleboro, MA 02703, USA.  
Copyright © 2021 Sensata Technologies, Inc.  
ISO9001CERTIFIED
Rev: Cynergy3-s2-ul-v3 03/09/21