Shenzhen-Kinghelm-Elec-KH-DW-K580-WZ

Part #Shenzhen-Kinghelm-Elec-KH-DW-K580-WZ
Download 
Shenzhen-Kinghelm-Elec-KH-DW-K580-WZ
产品规格书  
PRODUCT SPECIFICATION  
Customer:  
Customer’s part number:  
Product description:  
Uni Link’s part number:  
Issue Date:  
KH-DW-K580-WZ  
BD + GPS Antenna  
MS-BD+GPS-3  
2018-12-30  
Note:  
1575.42 /
 
1561MHz, SMA male , RG174
 
3m  
Application and Features  
Applications :  
1
:
1575.42 / 1561Mhz System  
2
:
Global Positioning System  
3
:
V
ehicle fixing position  
Features :  
1
:
Weight is light  
2
:
RHCP Polarization  
3
:
RoHS compliant  

INDEX  
1
、
PRODUCT TECHNICAL SPECIFIC
A
TION  
2
、
PRODUCT PICTURE  
3
、
PRODUCT SPECIFIC
A
TION CHART  
4
、
MECHANICAL CHARACTERISTICS  
5
、
DURABILITY  
6
、
PATCH TEST CURVE  
7
、
LAN TEST CURVE  

1
、
PRODUCT TECHNICAL SPECIFIC
A
TION  
Electrical Specifications  
1575.42
± 2
 
/ 1561
±
2  
Frequency Range (MHz)  
Bandwidth (MHz)  
Noise Figure (Typical )  
DC current
(
Typical
)  
Input Impedance (Ω)  
V
.
S.W.R  
4
1.5(+25
℃
±10
℃
)  
9.5mA(At 3.0V)  
50  
≤ 2.0  
28  
Gain (dBi)  
Max Input Power (w)  
5
Mechanical Specifications  
Antenna Dimension-mm
 
(mm)  
Connect Type  
49*38  
SMA male  
3-5  
Input
V
o
ltage (V)  
Work Temperature
 
℃  
Pole Diameter-mm  
Cable length-mm  
Weight (g)  
-40- +80  
Φ
40-50  
3000 + / – 30  
90  

2
、
PRODUCT PICTURE  
3
、
PRODUCT SPECIFIC
A
T
ION CHART.  
单位:
mm  

4
、
MECHANICAL CHARACTERISTICS
)  
1
BENDING  
TEST  
Put load 120g to 30cm cable from the end
 
after 1000 times test  
of the connector, fixed joints, swaying
 
no visible damage  
test at an angle of 60 degrees , test  
features after 1000 times  
STRENG TEST
 
Put 15pounds static load
 
to the end of
 
After test no visible  
the cable continue 1 minute
 
damage  
2
3
VIBRATION  
TEST  
the X-axis direction for 120 minutes, and
 
After test
 
no visible  
the Y-axis direction 120 minutes, the
 
damage  
Z-axis direction 240 minutes as vibration  
testing of 1.1mm amplitude and  
33.30Hz/sec of frequency  
5
、
DURABILITY  
1
HEAT TEST  
85+2
℃
for 24 hours, after keep in  
normal condition for 30mim the to test
.  
All characteristic  
range is 30% of  
the initial value  
2
HUMIDITY TEST  
40+2
℃
90-95%RH for 24hours, after  
keep in normal condition for 30mim the  
to test
.  
COLD TEST  
-40+2
℃
for 24hours, after keep in  
normal condition for 30mim the to test
.  
3

6
、
Patch Test Curve  

7
、
LAN Test Curve