STMicroelectronics-M24SR02-YMN6T-2

Part #STMicroelectronics-M24SR02-YMN6T-2
Download 
STMicroelectronics-M24SR02-YMN6T-2
M24SR02-Y  
Dynamic NFC/RFID tag IC with 2-Kbit EEPROM,  
NFC Forum Type 4
T
a
g and I²C interface  
Datasheet
–
production data  
Package  
•
8-lead small-outline package (SO8)  
ECOPACK2  
•
TSSOP8 ECOPACK2  
•
UFDFPN8 ECOPACK2  
UFDFPN8  
SO8  
TSSOP8  
Digital pad  
•
GPO: configurable general purpose output  
•
RF disable: activation/deactivation of RF  
commands  
Wafer  
Temperature range  
Features  
•
From – 40 °C up to 85 °C  
I

2

C interface  
Description  
M24SR02-Y belongs to the ST25 family, which  
includes all STMicroelectronics NFC/RFID tag  
and reader products.  
2
•
Two-wire I
 
C serial interface supports  
1 MHz protocol  
•
Single supply voltage: 2.7 V to 5.5 V  
Contactless interface  
The M24SR02-Y device is a dynamic NFC/RFID  
tag IC with a dual interface embedding an  
EEPROM. It can be operated from an I
 
C  
interface or by a 13.56 MHz RFID reader or from  
an NFC phone.  
•
NFC Forum Type 4 Tag  
•
ISO/IEC 14443 Type A  
•
106 Kbps data rate  
2
•
Internal tuning capacitance: 25 pF  
2
The I
 
C interface uses a two-wire serial interface,  
consisting of a bidirectional data line and a clock  
line. It behaves as a slave in the I
 
C protocol.  
Memory  
2
•
256-byte (2-kbit) EEPROM  
•
Support of NDEF data structure  
•
Data retention: 200 years  
The RF protocol is compatible with ISO/IEC  
14443 Type A and NFC Forum Type 4
T
a
g.  
•
Write endurance:  
– 1
 
million cycles at 25 °C  
– 600
 
k cycles at 85 °C  
•
Read: up to 246 bytes in a single command  
•
Write: up to 246 bytes in a single command  
•
7-byte unique identifier (UID)  
•
128-bit passwords protection  
April 2019  
DS9985 Rev 12  
1/88  
This is information on a product in full production.  
 

Contents  
M24SR02-Y  
Contents  

Supply voltage (V

CC

) .
 
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
 
12  
CC .
 
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
.
1
2  
2

I

C answer ready configuration (GPO field = 0xX3)
 
. . . . . . . . . . . . . . . 16  
2/88  
DS9985 Rev 12  

M24SR02-Y  
Contents  
2

I

C token
 
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30  
DS9985 Rev 12  
3/88  
5

Contents  
M24SR02-Y  
4/88  
DS9985 Rev 12  

M24SR02-Y  
Contents  
DS9985 Rev 12  
5/88  
5

List of tables  
M24SR02-Y  
List of tables  
6/88  
DS9985 Rev 12  

M24SR02-Y  
List of tables  

I

C frame format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60  

I

C operating conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68  

I

C DC characteristics
 
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69  
2

I

C AC characteristics (400 kHz) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70  
2

I

C AC characteristics (1 MHz
)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7
1  
DS9985 Rev 12  
7/88  
7

List of figures  
M24SR02-Y  
List of figures  

GPO configured as I

C answer ready (GPO field = 0xX3) . . . . . . . . . . . . . . . . . . . . . . . . . 16  

Figure 16.

C AC waveforms
 
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72  
8/88  
DS9985 Rev 12  

M24SR02-Y  
Functional description  
1
Functional description  
The M24SR02-Y device is a dynamic NFC/RFID tag that can be accessed either from the  
2
2
I C
 
or the RF interface. The RF and I
 
C host can read or write to the same memory, as only  
one host can communicate at a given time with the M24SR02-Y. The management of the  
interface selection is controlled by the M24SR02-Y device itself.  
The RF interface is based on the ISO/IEC 14443 Type A standard. The M24SR02-Y is  
compatible with the NFC Forum Type 4
T
a
g specifications and supports all corresponding  
commands.  
2
The I
 
C interface uses a two-wire serial interface consisting of a bidirectional data line and a  
clock line. The devices carry a built-in 4-bit device type identifier code in accordance with  
the I²C bus definition.  
2
The device behaves as a slave in the I
 
C protocol.  

Figure 1

displays the block diagram of the M24SR02-Y device.  
Figure 1. M24SR02-Y block diagram  
6XSSOꢄYROWDJH
 
9

&&
 

ꢁ
IRUꢄ,

ꢄꢄ

&ꢄLQWHUIDFH
 
h/ꢀꢁΘꢁƐLJƐƚĞŵꢁꢁꢁꢁ  
ĂƌĞĂ  
3RZHUꢄꢄꢄꢄ
 
PDQDJHPHQWꢄꢄꢄꢄ
 
XQLW
 
$QDORJꢄ)URQWꢋHQGꢄ
 
EDVHGꢄRQꢄ
 
5)ꢄLQWHUIDFHꢄꢄ
 
EDVHGꢄRQꢄ
 
,62ꢅ,(&ꢄꢂꢆꢆꢆꢀꢄ
 
7SHꢄ$ꢄVWDQGDUG
 
$&ꢂ
 
$&ꢊ
 
,62ꢅ,(&ꢄꢂꢆꢆꢆꢀꢄ
 
7SHꢄ$ꢄ
 
,QWHUQDOꢄWXQLQJ
 
FDSDFLWDQFHꢄꢄ
 
VWDQGDUG
 
1)&ꢄ)RUXPꢄ
 
7SHꢄꢆꢄ
7
D
Jꢄ
 
SURWRFRO
 
5)ꢄ
 
GLVDEOH
 
hƐĞƌꢁŵĞŵŽƌLJ  
*32
 
‘LJLWDOꢄXQLW
 
6&/
 
6’$
 
,

ꢁ

&ꢄLQWHUIDFH
 
ꢁꢇꢈꢄ9ꢄ±ꢄꢉꢇꢉꢄ9
 
1)&B,ꢁ&
 
LQWHUIDFH
 
*1′
 
06ꢀꢁꢀꢂꢃ9ꢀ
 
DS9985 Rev 12  
9/88  
20  
 
 

Functional description  
M24SR02-Y  
Table 1. Signal names  
Function  
Signal name  
Direction  
SDA  
Serial data  
I/O  
SCL  
Serial clock  
Input  
AC0, AC1  
V

CC  

Antenna coils  
–
–
–
Supply voltage  
V

SS  

Ground  
GPO  
Interrupt output

(1)  

Disables the RF communication

(2)  

Open drain output  
Input  
RF disable  
1. An
 
external pull-up > 4.7 k
Ω
is required.  
2. An
 
external pull-down is required when the voltage on V

cc

is above its POR level.  
Figure 2. 8-pin package connections  
ꢂ
ꢁ
ꢀ
ꢆ
ꢃ
ꢈ
ꢌ
ꢉ
5)ꢄGLVDEOH
 
$&ꢊ
 
9

&&
 

*32
 
6&/
 
6’$
 
$&ꢂ
 
9

66
 

06ꢀꢊꢈꢆꢆ9ꢁ
 
1. See
 

for package dimensions, and how to identify pin 1.  
1.1  
Functional modes  
The M24SR02-Y has two functional modes available. The difference between the modes  
lies in the power supply source (see

).  
Table 2. Functional modes  
Modes  
I

2

C mode  
Supply source  
Comments  
V

cc  

The I

2

C interface is available  
T
a
g mode  
RF field only  
The I

2

C interface is disconnected  
Both I

2

C and RF interfaces are available  
Dual interface mode  
RF field or V

cc  

2
1.1.1  
1.1.2  
I C
 
mode  
2
2
M24SR02-Y is powered by V
 
. The I
 
C interface is connected to the M24SR02-Y. The I
 
C  
host can communicate with the M24SR02-Y device.  
CC  
Tag mode  
The M24SR02-Y is supplied by the RF field and can communicate with an RF host (RFID  
reader or an NFC phone). The User memory can only be accessed by the RF commands.  
10/88  
DS9985 Rev 12  
 
 
 
 
 
 

M24SR02-Y  
Functional description  
1.1.3  
Dual interface mode  
2
2
Both interfaces, RF and I
 
C, are connected to the M24SR02-Y and both RF or I
 
C host can  
communicate with the M24SR02-Y device. The power supply and the access management  
are carried out by the M24SR02-Y itself. For further details refer to

DS9985 Rev 12  
11/88  
20  
 

Description of signals  
M24SR02-Y  
2
Description of signals  
2.1  
Serial clock (SCL)  
This input signal is used to strobe all data in and out of the device. In applications where this  
signal is used by slave devices to synchronize the bus to a slower clock, the bus master  
must have an open drain output, and a pull-up resistor must be connected from Serial clock  
(SCL) to V
 
. (

indicates how the value of the pull-up resistor can be calculated).  
CC  
In most applications, though, this method of synchronization is not employed, and so the  
pull-up resistor is not necessary, provided that the bus master has a push-pull (rather than  
an open drain) output.  
2.2  
2.3  
Serial data (SDA)  
This bidirectional signal is used to transfer data in or out of the device. It is an open drain  
output that may be wire-OR’ed with other open drain or open collector signals on the bus. A  
pull-up resistor must be connected from Serial data (SDA) to V
 
. (

indicates how  
CC  
the value of the pull-up resistor can be calculated).  
Antenna coil (AC0, AC1)  
These inputs are used to connect the device to an external coil exclusively. It is advised not  
to connect any other DC or AC path to AC0 or AC1.  
When correctly tuned, the coil is used to access the device using NFC Forum Type 4  
commands.  
2.4  
Ground (V

SS

)  
V
, when connected, is the reference for the V
 
supply voltage for all pads, including AC0  
CC  
SS  
and AC1.  
2.5  
Supply voltage (V

CC

)  
This pin can be connected to an external DC supply voltage.  
Note:  
2.5.1  
An internal voltage regulator allows the external voltage applied on V
 
to supply the  
M24SR02-Y.  
CC  
Operating supply voltage V  
CC  
Prior to selecting the M24SR02-Y and issuing instructions to it, a valid and stable V  
CC  
voltage within the specified [V
 
(min), V
 
(max)] range must be applied.
T
o
m
aintain a  
CC  
CC  
stable DC supply voltage, it is recommended to decouple the V
 
line with suitable  
CC  
capacitors (usually of the order of 10 nF and 100 pF) close to the V
 
/ V
 
package pins.  
CC  
SS  
This voltage must remain stable and valid until the end of the transmission of the instruction  
and, for a writing instruction (UpdateBinary, ChangeReferenceData,  
12/88  
DS9985 Rev 12  
 
 
 
 
 
 
 
 

M24SR02-Y  
Description of signals  
EnableVerificationRequirement, DisableVerificationRequirement, EnablePermanentState,  
DisablePermanentState, until the completion of the internal I²C write cycle (t
 
).  
W
2.5.2  
2.5.3  
Power-up conditions  
When the power supply is turned on, V
 
rises from V
 
to V
 
. The V
 
rise time must not  
vary faster than 1 V/µs.  
CC  
SS  
CC  
CC  
Device reset in I²C mode  
In order to prevent inadvertent write operations during power-up, a power-on reset (POR)  
circuit is included. At power-up (continuous rise of V
 
), the M24SR02-Y does not respond  
CC  
to any I²C instruction until V
 
has reached the power-on reset threshold voltage (this  
CC  
threshold is lower than the minimum V
 
operating voltage defined). When V
 
passes  
CC  
CC  
over the POR threshold, the device is reset and enters the Standby power mode. However,  
the device must not be accessed until V
 
has reached a valid and stable V
 
voltage  
CC  
CC  
within the specified [V
 
(min), V
 
(max)] range.  
CC  
CC  
In a similar way, during power-down (continuous decrease in V
 
), as soon as V
 
drops  
CC  
CC  
below the power-on reset threshold voltage, the M24SR02-Y stops responding to any  
instruction sent to it.  
2.5.4  
Power-down conditions  
During power-down (continuous decay of V
 
), the M24SR02-Y must be in Standby power  
CC  
mode (mode reached after decoding a Stop condition, assuming that there is no internal  
operation in progress).  
2.6  
RF disable  
This input signal is used to disable the RF communication. When the voltage on the V
 
pin  
CC  
is below the POR level or not connected, an internal pull-down resistor is connected on this  
pad. Thus, the RF disable pad is maintained to the low level and the RF analog front end is  
activated. When the voltage on the V
 
pin is higher than the POR level, the I²C host must  
CC  
set this pin to enable or disable the RF communication. In Dual interface mode, RF disable  
must not be left floating.  
2.7  
General purpose output (GPO)  
The GPO pad is an open drain pad and a external pull-up resistor must be connected to it.  
This pad is a configurable output signal. On delivery, GPO is configured as Session opened.  
2
Its behavior is consistent with the I
 
C or RF session activated and with the mode chosen by  
2
the user. The GPO pad is enable when an RF or an I
 
C session is open. When neither an  
2
RF nor an I
 
C session is open, the GPO is high impedance.  
DS9985 Rev 12  
13/88  
20  
 
 
 
 
 

Description of signals  
M24SR02-Y  
(a)  
The user can select one of these configurations  
:
2
•
•
SessionOpen: an RF or I C session is ongoing.  
MIP (NDEF Message updating In Progress): the RF host is writing an NDEF length  
different from 0x0000. This mode can be used to detect when the RF host changes the  
NDEF message as defined by the NFC Forum.  
•
•
WIP (Writing In Progress): the M24SR02-Y is executing a writing operation.  
2
INT (interrupt): the I C or RF host can force the M24SR02-Y to send a negative pulse  
on the GPO pin.  
2
2
•
•
I C ready response: an I C response is ready to be read by the I²C host.  
2
State mode: the I C or RF host can control the state of the GPO pad during the RF  
session.  
•
RF busy: an RF host is communicating with the M24SR02-Y.  
2.7.1  
Session Open configuration (GPO field = 0xX1 or 0x1X)  
2
When the GPO is configured as “Session Open”, it goes to the Low state when an RF or I
 
C  
session is ongoing (see

).  
An RF session is taken when M24SR02-Y receives a valid Select Application. The session  
is released after M24SR02-Y has received a valid Deselect command, if M24SR02-Y has  
2
received a Kill RF session command in I
 
C or when the RF field became OF
F
.  
2
An I
 
C session is taken when M24SR02-Y receives a valid Get session command or a valid  
2
Kill RF session command. The session is released after M24SR02-Y has received I
 
C token  
release sequence or after a power-off.  
GPO is driven low after a delay (1) or (3) when the session is open.  
GPO is released after a delay (2) or (4) when the session is released.  
Figure 3. GPO configured as Session Open (GPO field = 0xX1 or 0x1X)  
^ĞƐƐŝŽŶ  
Z&ꢁ  
^ĞƐƐŝŽŶ  
Z&ꢁ^ĞƐƐŝŽŶ  
/Ϯꢂꢁ^ĞƐƐŝŽŶ  
;ϰͿ  
;ϯͿ  
;ϭͿ  
;ϮͿ  
‘WKꢁĂƐꢁ^ĞƐƐŝŽŶꢁKƉĞŶ  
D^ϯϬϳϴϰsϮ  
1. CmdEOFtoGPlow
 
(RF command End of frame to GPORF Session pad low)  
2. CmdEOFtoGPHZ
 
(RF command End of frame to GPORF Session pad HZ)  
3. CmdSTPtoGPlow
 
(I2C command stop to GPO low)  
4. AnswerlbLBtoGPHZ
 
(I2C answer last bit of last byte to GPO HZ)  
a. See
 

for more details.  
14/88  
DS9985 Rev 12  
 
 
 

M24SR02-Y  
Description of signals  
2.7.2  
WIP Writing in Progress configuration (GPO field = 0xX2 or 0x2X)  
2
When the GPO is configured as “WIP”, it goes to the Low state during an I C or RF writing  
operation.  
2
During an RF or I
 
C session, when M24SR02-Y updates a file, GPO is driven low after a  
delay (1) or (3) following the beginning of the correspondent UpdateBinary command  
execution.  
GPO will remain low during the writing time (2) or (4), before being released.  
Figure 4. GPO configured as WIP (GPO field = 0xX2 or 0x2X)  
;ϭͿꢁ  
Z&ꢁŽƌꢁ/Ϯꢂꢁ  
ĐŚĂŶŶĞůꢁꢁ  
Žƌꢁ  
;ϯͿ  
hƉĚĂƚĞꢁ  
ĐŽŵŵĂŶĚ  
ꢄŶĚꢁŽĨꢁǁƌŝƚŝŶŐꢁ  
ŽƉĞƌĂƚŝŽŶ  
ꢃŶLJꢁŽƚŚĞƌꢁ  
ĐŽŵŵĂŶĚ  
‘WKꢁĂƐꢁt/W  
;ϮͿꢁŽƌꢁ;ϰͿ  
D^ϯϬϳϴϲsϯ  
1. CmdSTPtoGPlow
 
(I2C Command Stop to GPO low)  
2. Writing
 
time duration  
3. CmdEOFtoGPlow
 
(RF Command End of frame to GPO low)  
4. Writing
 
time duration  
DS9985 Rev 12  
15/88  
20  
 
 

Description of signals  
2
M24SR02-Y  
2.7.3  
I C
 
answer ready configuration (GPO field = 0xX3)  
2
When the GPO is configured as I C answer ready, it goes to the low state when the  
2
2
M24SR02-Y has finished to treat the I
 
C command and is ready to send the I C response.  
2
2
During an I
 
C session, after receiving a valid I
 
C command, GPO pin is driven low after a  
2
delay when M24SR02-Y is ready to deliver a response on the I C bus.  
GPO is released when M24SR02-Y receives a new command.  
2
Figure 5. GPO configured as I C answer ready (GPO field = 0xX3)  
/ϸꢂꢁĐŚĂŶŶĞů  
KƉĞŶꢁ  
^ĞƐƐŝŽŶ  
ꢃŶLJꢁ/ϸꢂꢁ  
ĐŽŵŵĂŶĚ  
DϮϰ^Zdždžꢁ  
ƌĞƐƉŽŶƐĞ  
ꢃŶLJꢁ/ϸꢂꢁ  
ĐŽŵŵĂŶĚ  
DϮϰ^Zdždžꢁ  
ƌĞƐƉŽŶƐĞ  
ꢃŶLJꢁ/ϸꢂꢁ  
ĐŽŵŵĂŶĚ  
DϮϰ^Zdždžꢁ  
ƌĞƐƉŽŶƐĞ  
‘WKꢁĂƐꢁ/ϸꢂꢁ  
ĂŶƐǁĞƌꢁƌĞĂĚLJ  
D^ϯϬϳϴϴsϰ  
16/88  
DS9985 Rev 12  
 
 
 

M24SR02-Y  
Description of signals  
2.7.4  
MIP NDEF Message writing in Progress configuration  
(GPO field = 0x3X)  
When the GPO is configured as MI
P
,
i
ts state goes to the low state when the RF host writes  
the NDEF length to another value than 0x0000.  
During an RF session, when M24SR02-Y changes an NDEF file and updates the NDEF  
length with a value different from 0x0000, GPO is driven low after a delay (1) following the  
beginning of the correspondent UpdateBinary command execution.  
GPO will remain low during the writing time (2), before being released.  
Figure 6. GPO configured as MIP (GPO field = 0x3X)  
Z&ꢁĐŚĂŶŶĞů  
hƉĚĂƚĞꢁƚŚĞꢁEꢀꢄ&ꢁ  
ůĞŶŐƚŚꢁ͊сꢁϬdžϬϬϬϬ  
DϮϰ^Zdždžꢁ  
ƌĞƐƉŽŶƐĞ  
ꢃŶLJꢁŽƚŚĞƌꢁ  
ĐŽŵŵĂŶĚ  
‘WKꢁĂƐꢁD/W  
;ϭͿ  
;ϮͿ  
D^ϯϬϳϴϱsϯ  
1. CmdEOFtoGPlow
 
(RF command End of frame to GPO low)  
2. Writing
 
time duration  
DS9985 Rev 12  
17/88  
20  
 
 

Description of signals  
M24SR02-Y  
2.7.5  
INT interrupt configuration (GPO field = 0xX4 or 0x4X)  
2
The I
 
C or RF host can send a negative pulse on the GPO pad. The GPO pad goes to the  
low state at the end of the command and goes to the high state at the end of the M24SR02-  
Y response.  
2
During an RF or I
 
C session, when M24SR02-Y receives a valid Interrupt command,  
M24SR02-Y GPO pin is driven low after (1) or (3) for a duration of (4) in R
F
,
o
r after  
responding in I2C (2). Then GPO pin is released.  
Figure 7. GPO configured as INT (GPO field = 0xX4 or 0x4X)  
Z&ꢁŽƌꢁ/ϸꢂꢁ  
ĐŚĂŶŶĞů  
;ϭͿꢁ  
Žƌꢁ  
;ϯͿ  
;ϮͿꢁꢁ  
DϮϰ^Zdždžꢁ  
ƌĞƐƉŽŶƐĞ  
^ĞŶĚꢁ  
/ŶƚĞƌƌƵƉƚ  
ꢃŶLJꢁŽƚŚĞƌꢁ  
ŽƉĞƌĂƚŝŽŶ  
‘WKꢁĂƐꢁ/Ed  
;ϰͿꢁꢁ  
D^ϯϬϳϴϳsϯ  
1. CmdSTPtoGPlow
 
(I2C command Stop to GPO low)  
2. After
 
NewCmdlbFB (new I2C command last bit of first byte)  
or  
after AnswerlbFB (I2C answer last bit of first byte)  
3. CmdEOFtoGPlow
 
(RF command End of frame to GPO low)  
4. GPO
 
pulse duration  
18/88  
DS9985 Rev 12  
 
 

M24SR02-Y  
Description of signals  
2.7.6  
State control configuration (GPO field = 0xX5 or 0x5X)  
2
When the GPO is configured as State control, the I
 
C or RF host can control the state of the  
GPO by sending a dedicated command.  
2
During an RF or I
 
C session, the M24SR02-Y can control the GPO pin. After receiving a  
valid Set GPO command, GPO pin is driven low after a delay (1) or (3). GPO will be  
released after a valid Reset command or after a power-off or upon closing the RF session.  
Figure 8. GPO configured as State control (GPO field = 0xX5 or 0x5X)  
5)ꢄRUꢄ,ð&ꢄ
 
FKDQQHO
 
ꢎꢂꢏꢄ
 
RUꢄ
 
ꢎꢀꢏ
 
ꢎꢁꢏꢄ
 
RUꢄ
 
ꢎꢆꢏ
 
5HVHWꢄ*32ꢄ
 
FRPPDQGꢄꢄ
 
$QꢄRWKHUꢄ
 
FRPPDQG
 
6HWꢄ*32ꢄ
 
FRPPDQG
 
*32ꢄDVꢄ
 
6WDWH&RQWURO
 
06ꢀꢊꢈꢃꢍ9ꢆ
 
1. CmdSTPtoGPlow
 
(I2C Set GPO command Stop to GPO low)  
2. CmdSTPtoGPHZ
 
(I2C Reset GPO command Stop to GPO HZ)  
3. CmdEOFtoGPlow
 
(RF Set GPO command End of frame to GPO low)  
4. CmdEOFtoGPHZ
 
(RF Reset GPO command End of frame to GPO HZ)  
DS9985 Rev 12  
19/88  
20  
 
 
 
 

Description of signals  
M24SR02-Y  
2.7.7  
RF busy configuration (GPO field = 0x6X)  
When the GPO is configured as RF busy, the GPO goes to the low state when the  
M24SR02-Y is processing an RF command or when an RF session is ongoing.  
When an RF field is present, GPO is driven low after a delay (1) when M24SR02-Y detects  
the first command. If the RF session is ongoing and M24SR02-Y receives a not-supported  
command, GPO remains low. It will be released only at the end of the RF session, after (2).  
Figure 9. GPO configured as RF busy (GPO field = 0x6X)  
Z&ꢁĐŚĂŶŶĞů  
;ϭͿ  
;ϮͿ  
;ϭͿ  
;ϮͿ  
Z&ꢁ  
ĐŽŵŵĂŶĚ  
^ĞŶƐZĞƋꢁΘꢁ  
^ĞŶƐZĞƐ  
Z&ꢁĐŽŵŵĂŶĚꢁ  
ŶŽƚꢁƐƵƉƉŽƌƚĞĚꢁꢁꢁꢁ  
^;ꢀꢄ^Ϳ  
‘WKꢁĂƐꢁZ&ꢁďƵƐLJ  
D^ϯϬϳϵϬsϯ  
1. CmdSOFtoGPlow
 
(RF command Start of frame to GPO low)  
2. CmdEOFtoGPHZ
 
(RF command End of frame to GPO HZ)  
20/88  
DS9985 Rev 12  
 
 

M24SR02-Y  
M24SR02-Y memory management  
3
M24SR02-Y memory management  
3.1  
Memory structure  
The M24SR02-Y supports the NDEF tag application as defined in the NFC Forum Type 4  
T
a
g. The M24SR02-Y is composed of three files:  
•
•
•
a CC (capability container) file  
an NDEF file  
a System file: this is an ST-proprietary file  
The System file contains information on the configuration of the M24SR02-Y device. The  
CC file gives information about the M24SR02-Y itself and the NDEF file. The NDEF file  
contains the User data.  
3.1.1  
File identifier  
The file identifier is the value used in the Select command to select a file.  
Table 3. File identifier  
File identifier  
0xE101  
Meaning  
System file  
CC file  
0xE103  
0x0001  
NDEF file  
3.1.2  
CC file layout  
The CC file gives information about the M24SR02-Y and the NDEF file. This is a read-only  
file for the RF or I²C host and cannot be modified by issuing a write command.  
The T field, Read Access and Write Access fields can be changed by the RF or I²C host by  
issuing a specific process (refer to

).  
DS9985 Rev 12  
21/88  
29  
 
 
 
 
 
 

M24SR02-Y memory management  
File offset  
M24SR02-Y  
Comments  
Table 4. CC file layout for 1 NDEF file  
Meaning Value  
0x0000  
0x0002  
0x0003  
0x0005  
0x0007  
0x0008  
0x0009  
Number of bytes of CC file  
0x000F  
15 bytes  
Mapping version

(1)  

0x20 or 0x10  
0x00F6  
V 2.0 or V 1.0  
246 bytes  
246 bytes  
T field  
Maximum number of bytes that can be read  
Maximum number of bytes that can be written
 
0x00F6  
0x04

(2)  

0x06  
L field  
0x0001  
FileID  
NDEF file control TLV  
0x0100  
Maximum NDEF  
file size  
0x000B  
0x000D  
0x000E  
0x00

(2)  

0x00

(2)  

Read access  
Write access  
1. According
 
to the reader.  
2. Delivery
 
state.  
3.1.3  
NDEF file layout  
The NDEF file contains the NDEF message, which contains the user data. The RF host or  
the I²C host can read and write data inside the file. The first two bytes (named NDEF  
message length) define the size of the NDEF message. The NDEF message length must be  
managed by the application and the M24SR02-Y device does not check if its value is  
relevant vs. the data written by the RF or I²C host. The M24SR02-Y device uses the NDEF  
message length, e. g. the standard read can be processed only inside the NDEF message;  
otherwise, the M24SR02-Y device returns an error code. For more details about the read  
22/88  
DS9985 Rev 12  
 
 
 

M24SR02-Y  
M24SR02-Y memory management  
Table 5. NDEF file layout  
Byte 0
 
Byte 1  
NDEF message length  
File offset  
Byte 2  
Byte 3  
0x0000  
0x0004  
…  
User data  
User data  
User data  
User data  
User data  
User data  
…  
…  
…  
…  
…  
…  
…  
…  
…  
…  
…  
…  
…  
…  
…  
…  
…  
0x00FC  
User data  
3.1.4  
System file layout  
The system file specifies the configuration of the M24SR02-Y.

lists the different  
fields.  
Table 6. Field list  
File  
offset  
Number  
of bytes  
Read  
access  
Write  
access  
Field name  
Delivery state

(1)  

0x0000 Length
 
system file  
0x0002 I²C
 
protect  
0x0003 I²C
 
watchdog  
0x0004 GPO  
2
1
1
1
1
1
1
7
2
1
I²C or RF  
I²C or RF  
I²C or RF  
I²C or RF  
I²C or RF  
I²C or RF  
I²C or RF  
I²C or RF  
I²C or RF  
I²C or RF  
–
0x0012  
I²C

(2)  

I²C

(2)  

I²C

(2)  

I²C

(2)  

I²C

(2)  

none  
none  
none  
none  
0x01  
0x00  
0x11  
0x0005 ST
 
reserved  
0x0006 RF
 
enable  
0x0007 NDEF
 
file number (RFU)  
0x0008 UID  
0x00  
0x xxxx xxx1

(3)  

0x00  
0x0282 xx xx xx xx xx

(4)  

0x000F Memory
 
size  
0x0011 Product
 
code  
0x00FF  
0x82  
1. The
 
delivery state for all passwords is 0x00000000000000000000000000000000.  
2. The
 
access is granted when the field I²C protect is set to the state Unprotected or when the right I²C  
password is correctly received (see

).  
3. Refer
 
to

.  
4. x
 
values are defined by ST to insure UID unicity.  
DS9985 Rev 12  
23/88  
29  
 
 
 
 
 

M24SR02-Y memory management  
File offset  
M24SR02-Y  
2
Table 7. Details about I C watchdog  
b7- b0  
The I

2

C watchdog ensures that the I2C host will not keep the session open while there  
is no more activity on the I

2

C bus (between the stop bit of the previous transaction and  
the start bit of the next one).  
– b7-b3: RFU  
– b2-b0

(1)  

:
000: watchdog
 
disabled  
001: N
 
= 1
→
30 ms  
010: N
 
= 2
→
60 ms  
011: N
 
= 4
→
120 ms  
100: N
 
= 8
→
240 ms  
101: N
 
= 16
→
480 ms  
110: N
 
= 32
→
960 ms  
111: N
 
= 64
→
1920 ms  
0x0003  
1. If
 
b2-b0 are programmed to a non null value (N), the watchdog is enabled and starts counting for the  
indicated (approximate) duration, before releasing the I

2

C session.  
Table 8. Details about the GPO field  
File offset  
0x0004  
RFU  
b7  
b6-b4  
b3  
b2-b0  
When an RF session is open:  
0b000: High impedance  
0b001: Session opened  
0b010: WIP  
0b011: MIP  
0b100: Interrupt  
0b101: State control  
0b110: RF busy  
0b111: RFU  
RFU  
When an I²C session is open:  
0b000: High impedance  
0b001: Session opened  
0b010: WIP  
0b011: I²C answer ready  
0b100: Interrupt  
0b101: State control  
0b110: RFU  
0b111: RFU  
24/88  
DS9985 Rev 12  
 
 
 

M24SR02-Y  
M24SR02-Y memory management  
Table 9. Details about the RF session field  
b7 b6-b4  
File offset  
0x0004  
b3-b0  
RFU  
When an RF session is open:  
0b001: Session opened  
RFU  

T

gives some details about the ST reserved field.  
Table 10. Details about the ST reserved field  
File offset
 
b7-b0  
0x0005  
0x00  

T

gives some details about the RF enable field.  
Table 11. Details about the RF enable field  
b7 b6-b4
 
b3 b2-b1  
File offset  
0x0006  
b0  
0: the RF field is off

(1)  

1: the RF field is on

(1)  

RFU  
0: the RF disable pad is at low state

(1)  

1: the RF disable pad is at high state

(1)  

RFU  
0: the M24SR02-Y does not decode the command received from the RF interface  
1: the M24SR02-Y decodes the command received from the RF interface  
1. this
 
field is written by the M24SR02-Y.  
3.2  
Read and write access rights to the memory  
An NDEF file can be locked for read or write accesses. It is also protected by a 128-bit  
password that the host must present before accessing the NDEF file. There are two 128-bit  
passwords, one for the read access and the other one for the write access.  
An NDEF file can be permanently locked for read or write accesses. Thus, the host cannot  
access the NDEF file.  
The read password must be sent to the M24SR02-Y device before reading a read-locked  
NDEF file.  
DS9985 Rev 12  
25/88  
29  
 
 
 
 

M24SR02-Y memory management  
M24SR02-Y  
The write password must be present on the M24SR02-Y device before writing a write-  
locked NDEF file. The write password must be sent to change the read or write access. The  
read or write access right is defined for the NDEF file.  
3.2.1  
State of the Read and Write access rights  
Two bytes in the CC file are used to define the Read and Write access rights to the NDEF  
file. For more details refer to

.  
Table 12. Read access right  
Value  
Meaning  
0x00  
0x80  
0xFE  
Read access without any security  
Locked

(1)  

Read not authorized  
1. The
 
read password must be sent before reading in the NDEF file.  
Table 13. Write access right  
Value  
Meaning  
0x00  
0x80  
0xFF  
Write access without any security  
Locked

(1)  

Write not authorized  
1. The
 
write password must be sent before writing in the NDEF file.  
The state 0xFF and 0xFE cannot be changed by using the Read or Write passwords.  
26/88  
DS9985 Rev 12  
 
 
 

M24SR02-Y  
M24SR02-Y memory management  
3.2.2  
Changing the read access right to NDEF files  
The state diagram on

shows how to change the access right to read an NDEF file.  
Figure 10. Changing the read access right to an NDEF file  
ꢊ[ꢊꢊ
 
/RFNꢄWKHꢄ1′()ꢄILOHꢄ

ꢎꢂꢏ
 

3HUPDQHQWOꢄORFNꢄWKHꢄ1′()ꢄILOHꢄ

ꢎꢀꢏ
 

8QORFNꢄWKHꢄ1′()ꢄILOHꢄ

ꢎꢁꢏ
 

3HUPDQHQWOꢄORFNꢄWKHꢄ1′()ꢄILOHꢄ

ꢎꢀꢏ
 

ꢊ[ꢃꢊꢄ

ꢎꢆꢏ
 

ꢊ[)(ꢄ

ꢎꢆꢏ
 

3HUPDQHQWOꢄXQORFNꢄWKHꢄ1′()ꢄILOH
 
06Yꢆꢃꢊꢀꢀ9ꢂ
 
1. See
 
the procedure to lock the read access (

).  
2. See
 
the procedure to unlock the read access (

).  
3. See
 
the procedure to permanently lock the read access (

4. Proprietary
 
state, not defined by NFC Forum Type 4 Tag. For NFC Forum compatible tags, the only  
possible value of the read access rights are 0x00 (no restrictions on reads).  
DS9985 Rev 12  
27/88  
29  
 
 
 
 

M24SR02-Y memory management  
M24SR02-Y  
3.2.3  
Changing the write access right to NDEF files  
The state diagram on
Figure 1
shows how to change the write access right to an NDEF file.  
Figure 11. Changing the write access right to an NDEF file  
ꢊ[ꢊꢊ
 
/RFNꢄWKHꢄ1′()ꢄILOHꢄ

ꢎꢂꢏ
 

3HUPDQHQWOꢄORFNꢄWKHꢄ1′()ꢄILOHꢄ

ꢎꢀꢏ
 

8QORFNꢄWKHꢄ1′()ꢄILOHꢄ

ꢎꢁꢏ
 

3HUPDQHQWOꢄORFNꢄWKHꢄ1′()ꢄILOHꢄ

ꢎꢀꢏ
 

ꢊ[ꢃꢊꢄ

ꢎꢆꢏ
 

ꢊ[))
 
3HUPDQHQWOꢄXQORFNꢄWKHꢄ1′()ꢄILOH
 
06Yꢆꢃꢊꢀꢆ9ꢂ
 
1. See
 
the procedure to lock the write access.  
2. See
 
the procedure to unlock the write access.  
3. See
 
the procedure to permanently lock the write access (

4. Proprietary
 
state, not defined by NFC Forum Type 4 Tag. For NFC Forum compatible tags, it is mandatory  
that the write access rights are set to either 0x00 (no restrictions on writes) or to 0xFF (permanently  
locked). 0x80 might not be fully decoded by some smart phones.  
3.3  
3.4  
Access right life time  
The access right life time is validated while the NDEF file is selected or until the end of the  
RF or I²C session. Once the read or write access right is granted, the host can send one or  
more ReadBinary or UpdateBinary commands.  
At the end of a session or when the host selects another file, the read and write access  
rights are initialized.  
NDEF file passwords  
The NDEF file passwords protect the read or write access from an RF or I²C interface  
from/to an NDEF file.  
Two NDEF file passwords are available for each NDEF file:  
•
•
Read password  
Write password  
The length of a password is 128 bits (16 bytes).  
28/88  
DS9985 Rev 12  
 
 
 
 
 
 

M24SR02-Y  
M24SR02-Y memory management  
3.5  
I

2

C password  
The I²C password can be sent only by the I²C host. It activates the SuperUser rights. The I²C  
host with the SuperUser rights can:  
•
access the NDEF file regardless of the right access and without sending the NDEF file  
passwords  
•
change the access rights regardless of the current state.  
The length of the I²C password is 128 bits (16 bytes).  
3.5.1  
I²C password and I²C protect field of the System file  
The I²C protect field in the system file can be set to:  
•
•
0x00: the I²C host has the SuperUser right access without sending the I²C password  
0x01: the I²C host has the SuperUser right access after sending the I²C password.  
For more details about the system file layout, refer to

.  
DS9985 Rev 12  
29/88  
29  
 
 

Communication mechanism  
M24SR02-Y  
4
Communication mechanism  
2
This section describes the principle of communication between an RF or an I
 
C host and the  
M24SR02-Y device.  
4.1  
Master and slave  
2
The M24SR02-Y acts as a slave device on either the I C-bus or the RF channel and  
2
therefore waits for a command from the I
 
C master or the RF host before sending its  
response.  
The RF host must generate the RF field and the RF commands.  
2
2
The I
 
C host must supply the M24SR02-Y through the V
 
pin and must generate the I C  
CC  
clock on the SCL pad.  
4.2  
M24SR02-Y session mechanism  
2
The M24SR02-Y is a dynamic NFC/RFID tag that can be accessed either from the RF or I
 
C  
interface. The M24SR02-Y implements a token system. This token has two possible values,  
2
2
RF or I C. When the token exists and is assigned to one interface (RF or I C), the  
M24SR02-Y cannot communicate with the other host.  
4.2.1  
4.2.2  
RF token  
The token is given to the RF interface once the anticollision is done. The release condition  
can be either an RF field cut-off, or the reception of the command deselect, or when the I²C  
host sends the KillRFsession.  
2
I C
 
token  
2
2
The token is given to the I
 
C interface when the I
 
C host has sent the correct device Select.  
The release condition can be either a power down condition on V
 
pin or the reception of a  
CC  
2
2
I C token release sequence from the I C host, after which M24SR02-Y goes in Standby  
power mode.  
30/88  
DS9985 Rev 12  
 
 
 
 
 
 
 

M24SR02-Y  
I²C and RF command sets  
5
I²C and RF command sets  
The command sets of the M24SR02-Y can be split in different command families. Most  
commands are common between the RF and the I²C interface. Some commands are  
specific to the RF interface and some others are specific to the I²C interface. This section  
describes the M24SR02-Y command sets that can be issued by the RF or the I²C host.  
There are three command families:  
•
•
•
the NFC Forum Type 4
T
a
g command set  
the ISO/IEC 7816-4 command set  
the proprietary command set  
The NFC Forum Type 4
T
a
g command set and the ISO/IEC 7816-4 command set use the  
I-Block format. For more details about the I-Block format, refer to

.  
Two other command formats exist:  
•
•
the commands using the R-Block format (refer to

)  
the commands using the S-Block format (refer to

).  
This section gives a brief description of the RF and I²C host common commands. The  
format of these command sets is the I-Block format.  

T

lists the RF and I²C command sets.  
Table 14. RF and I²C command sets  
Family  
command set  
Class Instruction  
Command name  
Brief description  
byte  
code  
NDEF
T
a
g Application  
Select  
NDEF
T
a
g Application Select  
0x00  
0xA4  
CC select  
0x00  
0x00  
0x00  
0x00  
0xA4  
0xA4  
0xA4  
0xB0  
Select the CC file  
NDEF select  
System select  
ReadBinary  
Select the NDEF file  
Select the system file  
Read data from file  
NFC Forum  
Type 4
T
a
g  
Write or erase data to a  
NDEF file  
UpdateBinary  
Verify  
0x00  
0x00  
0x00  
0xD6  
0x20  
Checks the right access of  
a NDEF file or sends a  
password  
Change a Read or write  
password  
ChangeReferenceData  
0x24  
0x28  
0x26  
ISO/IEC 7816-4  
Activate the password  
security  
EnableVerificationRequirement 0x00  
DisableVerificationRequirement 0x00  
Disable the password  
security  
Enable the Read only or  
Write only security state  
EnablePermanentState  
ExtendedReadBinary  
0xA2  
0xA2  
0x28  
0xB0  
ST proprietary  
Read data from file  
DS9985 Rev 12  
31/88  
78  
 
 

I²C and RF command sets  
M24SR02-Y  
5.1  
Structure of the command sets  
The exchange of data between the RF or the I²C host and the M24SR02-Y uses three kinds  
of data formats, called blocks:  
•
•
•
I-Block: to exchange the command and the response  
R-Block: to exchange positive or negative acknowledgment  
S-Block: to use either the Deselect command or the Frame waiting extension (WTX)  
command or response.  
Note:  
Max WTX value = 0x0B  
This section describes the structure of the I-Block, R-block and S-Block. This format is used  
for the application command set.  
5.2  
I-Block format  
The I-Block is used to exchange data between the RF or the I²C host and the M24SR02-Y.  
It is composed of three fields.

details the I-Block format.  
Table 15. I-Block format  
SoD  
Payload  
0
EoD  
CRC  
Name  
PCB  
DID  
Length  
1 byte  
1 byte  
1 to 251 bytes  
2 bytes  
PCB field  
DID field (optional)  
RF or I²C host to M24SR02-Y: C-APDU  
M24SR02-Y to RF or I²C host: R-APDU  
2 CRC bytes  
32/88  
DS9985 Rev 12  
 
 
 

M24SR02-Y  
I²C and RF command sets  
Table 16. PCB field of the I-Block format  
b7-b6  
0b00  
b5  
0
b4  
0
b3  
X
b2  
0
b1  
1
b0  
X
–
I-Block  
RFU  
Must be set to 0  
DID field, if bit is set  
Must be set to 0  
Must be set to 1  
Block number  
When the RF or I²C host sends a command to the M24SR02-Y the format of the payload is  
the C-APDU.  
When the M24SR02-Y sends a command to the RF or I²C host, the format of the payload is  
the R-APDU.  
5.2.1  
C-APDU: payload format of a command  
The C-APDU format is used by the RF or the I²C host to send a command to the M24SR02-  
Y.

describes its format.  
Table 17. C-APDU format  
Payload field  
Name  
CLA  
INS  
P1  
P2  
LC  
Data  
Le  
Length  
1 byte  
1 byte  
1 byte  
1 byte  
1 byte  
Lc byte  
1 byte  
Class byte  
0x00: standard command  
0xA2: ST command  
Instruction byte  
Parameter Byte 1  
Parameter Byte 2  
Number of bytes of the Data field  
Data bytes  
Number of bytes to be read in the M24SR02-Y memory  
5.2.2  
R-APDU: payload format of a response  
The M24SR02-Y uses the I-Block format to reply to a command that used the I-Block  
format. This format is described in

.  
DS9985 Rev 12  
33/88  
78  
 
 
 
 

I²C and RF command sets  
M24SR02-Y  
Table 18. R-APDU format  
Payload field  
Name  
Data (optional)  
Le byte  
SW1  
SW2  
1 byte  
Length  
1 byte  
Data  
Status byte 1  
Status byte 2  
5.3  
R-Block format  
The R-Block is used to convey positive or negative acknowledgment between the RF or I²C  
host and the M24SR02-Y.  
Table 19. R-Block format  
PCB  
CRC  
R(ACK) without the DID field: 0xA2 or 0xA3  
R(ACK) with the DID field: 0xAA or 0xAB  
R(NAK) without the DID field: 0xB2 0xB3  
R(NAK) with the DID field: 0xBA 0xBB  
2 CRC bytes  
There are two kinds of R-Blocks:  
•
•
R(ACK): the acknowledgment block sent by the RF or I²C host or by the M24SR02-Y.  
R(
NAK
): the non-acknowledgment block sent by the RF or I²C host or by the  
M24SR02-Y.  
34/88  
DS9985 Rev 12  
 
 
 

M24SR02-Y  
I²C and RF command sets  
Table 20. R-Block detailed format  
b7-b6  
0b10  
b5  
1
b4  
X
b3  
X
b2  
0
b1  
1
b0  
X
–
R-Block  
RFU  
1: NAK  
0: ACK  
0: DID field is not present  
1: DID field is present  
Must be set to 0  
Must be set to 1  
Block number  
5.4  
S-Block format  
The S-Block is used to exchange control information between a reader and a contactless  
tag.  
Table 21. S-Block format  
SoD  
EoD  
CRC  
NFC frame  
Length  
PCB  
DID  
Payload  
1 byte  
1 byte  
1 to 255 bytes  
2 bytes  
0xC2: for S(DES) when the DID field is not present  
0xCA: for S(DES) when the DID field is present  
0xF2: for S(WTX) when the DID field is not present  
0xFA: for S(WTX) when the DID field is present  
DID field (optional)  
WTX field

(1)  

2 CRC bytes  
1. This
 
field is present when b5-b4 bits are set to 0b11 (S-Block is a WTX). see

.  
There are two requests using the S-Block format:  
•
•
•
S(DES): the deselect command  
S(DES) is only applicable to RF  
S(WTX): the Waiting frame extension command or response.  
2
A Waiting time extension request occurs, in RF or I
 
C, when the operating time needed  
by M24SRxx is greater than 9.6 ms.  
The WTX field indicates the increase time factor to be used in this command execution  
(FDTtemp = WTX * 9.6 ms). The max WTX value is equal to 0x0B.  
DS9985 Rev 12  
35/88  
78  
 
 
 
 
 

I²C and RF command sets  
M24SR02-Y  
Table 22. S-Block detailed format  
b7-b6  
0b11  
b5-b4  
X
b3  
X
b2  
0
b1  
1
b0  
0
S-Block  
0b00: Deselect  
0b11: WTX  
0: DID field is not present  
1: DID field is present  
–
RFU  
RFU  
Note:  
After receiving the deselect command, the session is released and M24SR02-Y enters the  
Standby power mode. In I
 
C, the session is released after executing the I2C token release  
2
sequence.  
In response to a RATS command, M24SR02-Y returns FWI parameter (default frame waiting  
time used); when M24SR02-Y needs more time for a command execution, it requests a  
frame waiting time extension by responding 0xF2 0xWTX (request waiting time = FWI *  
WTX). If the reader accepts M24SR02-Y request, it acknowledges by sending the command  
0xF2 0xWTX. The frame waiting time becomes FWI * WTX for the current command only.  
5.5  
CRC of the I

2

C and RF frame  
The two CRC bytes check the data transmission between the RF host or I²C host and the  
M24SR02-Y. For the RF frame, the CRC is computed on all the data bits in the frame,  
excluding parity bits, SOF and EO
F
,
a
nd the CRC itself.  
For the I²C frames, the CRC is computed on all data bits of the frame excluding Device  
select and the CRC itself.  
The CRC is as defined in ISO/IEC 13239. The initial register content must be 0x6363 and  
the register content must not be inverted after calculation.  
36/88  
DS9985 Rev 12  
 
 
 

M24SR02-Y  
I²C and RF command sets  
5.6  
NFC Forum Type 4 Tag protocol  
5.6.1  
Command set  
With the NFC Forum Type 4
T
a
g protocol, the commands are common to RF and I²C.  
Table 23. Command set overview  
Command name  
Brief description  
Select the NDEF
T
a
g Application  
NDEF
T
a
g Application Select  
Capability Container Select  
NDEF Select  
Select the capability container (CC) file using the Select command  
Select the NDEF file  
System File Select  
ReadBinary  
Select the system file  
Read data from a file  
UpdateBinary  
Write new data to a file  
5.6.2  
Status and error codes  
This section lists the status and the error code of the M24SR02-Y.  
Table 24. Status code of the M24SR02-Y  
–
SW1  
SW2  
Comment  
Value  
0x90  
0x00  
Command completed successfully  
Table 25. Error codes of the M24SR02-Y  
–
SW1  
SW2  
Comment  
Length  
1 byte  
0x62  
0x62  
0x63  
0x63  
0x65  
0x67  
0x69  
0x69  
0x69  
0x6A  
0x6A  
0x6A  
0x6A  
1 byte  
0x80  
0x82  
0x00  
0xCX  
0x81  
0x00  
0x81  
0x82  
0x84  
0x80  
0x82  
0x84  
0x86  
–
Value  
Value  
Value  
Value  
Value  
Value  
Value  
Value  
Value  
Value  
Value  
Value  
Value  
File overflow (Le error)  
End of file or record reached before reading Le bytes  
Password is required  
Password is incorrect, X further retries allowed (X = 0, 1, 2)  
Unsuccessful updating  
Wrong length  
Command is incompatible with the file structure  
Security status not satisfied  
Reference data not usable  
Incorrect parameters Le or Lc  
File or application not found  
File overflow (Lc error)  
Incorrect P1 or P2 values  
DS9985 Rev 12  
37/88  
78  
 
 
 
 
 
 

I²C and RF command sets  
M24SR02-Y  
Table 25. Error codes of the M24SR02-Y (continued)  
–
SW1  
SW2  
Comment  
Value  
Value  
0x6D  
0x6E  
0x00  
0x00  
INS field not supported  
Class not supported  
5.6.3  
NDEF Tag Application Select command  
The RF or the I²C host must send this command to activate the NDEF
T
a
g Application.  
To
a
ctivate the NDEF
T
a
g Application, the RF host sends the Select command (see  

T

) in addition to the sequence defined in the NFC Forum digital protocol.  
To
a
ctivate the NDEF
T
a
g Application, the I²C host sends the Select command (see  

T

) in addition to the GetSession or the Kill RF session command.  

T

defines the C-APDU of the Select command to select the NDEF
T
a
g Application  
(called NDEF
T
a
g Application Select).  
Table 26. C-APDU of the NDEF Tag Application Select command  
Name  
Value  
Class byte  
CLA  
INS  
P1  
P2  
Lc  
Data  
Le  
0xD27600  
00850101  
0x00  
0xA4  
0x04  
0x00  
0x07  
0x00  
Select instruction code  
P1 field  
P2 field  
Number of bytes of data  
Application ID  
Le field  

T

defines the R-APDU of the NDEF
T
a
g Application Select command.  
Table 27. R-APDU of the NDEF Tag Application Select command  
–
Data  
SW1  
SW2  
Comment  
Length  
Value  
Value  
Value  
–
–
–
–
1 byte  
0x90  
0x6A  
0x6D  
1 byte  
0x00  
0x82  
0x00  
–
Command completed  
NDEF
T
a
g Application not found  
Class not supported  
5.6.4  
Capability Container Select command  
The RF or I²C host uses the Capability Container Select procedure to select the capability  
container (CC) file.  
38/88  
DS9985 Rev 12  
 
 
 
 
 

M24SR02-Y  
I²C and RF command sets  
The CC file is selected when this command returns “command completed” in the R-APDU.  

T

defines the C-APDU of the Select command to select the CC file (called Capability  
Container Select).  
Table 28. C-APDU of the Capability Container Select command  
Name  
Value  
Class byte  
CLA  
INS  
P1  
P2  
Lc  
Data  
Le  
0x00  
0xA4  
0x00  
0x0C  
0x02  
0xE103  
–
Select instruction code  
P1 field  
P2 field  
Number of bytes of data  
CC file ID  
–

T

defines the R-APDU of the CC Select command.  
Table 29. R-APDU of the Capability Container Select command  
–
Data  
SW1  
SW2  
Comment  
Length  
Value  
Value  
Value  
–
–
–
–
1 byte  
0x90  
0x6A  
0x6D  
1 byte  
0x00  
0x82  
0x00  
–
Command completed  
File or application not found  
Class not supported  
5.6.5  
NDEF Select command  
The RF or I²C host uses the NDEF Select command to select the NDEF file.  
The NDEF file is selected when this command returns “command completed” in the  
R-APDU.

defines the C-APDU of the Select command to select the NDEF file  
(called NDEF Select).  
In case of a password is required to access the NDEF file, the NDEF Select command will  
disable any previously granted access rights to this file. The Verify command might be  
required to access the file.  
DS9985 Rev 12  
39/88  
78  
 
 
 
 

I²C and RF command sets  
M24SR02-Y  
Table 30. C-APDU of the NDEF Select command  
Name  
CLA  
INS  
P1  
P2  
Lc  
Data  
Le  
Value  
0x00  
0xA4  
0x00  
0x0C  
0x02  
0x000X  
–
Class byte  
Select instruction code  
P1 field  
P2 field  
Number of bytes of data  
0x0001: first NDEF file  
–

T

defines the R-APDU of the NDEF Select command.  
Table 31. R-APDU of the NDEF Select command  
–
Data  
SW1  
1 byte  
SW2  
1 byte  
Comment  
Length  
Value  
Value  
–
–
–
–
0x90  
0x6A  
0x00  
0x82  
Command completed  
File or application not found  
5.6.6  
System File Select command  
The RF or I²C host uses this command to select the system file.  
The System file is selected when this command returns “command completed” in the R-  
APDU.  

T

defines the C-APDU of the command to select the System file (called System  
Select).  
Table 32. C-APDU of the System File Select command  
Name  
CLA  
INS  
P1  
P2  
Lc  
Data  
Le  
0x00  
0xA4  
0x00  
0x0C  
0x02  
0xE101  
–
Class byte  
Select instruction code  
P1 field  
P2 field  
Number of bytes of data  
System file ID  
–

T

defines the R-APDU of the System File Select command.  
40/88  
DS9985 Rev 12  
 
 
 
 

M24SR02-Y  
I²C and RF command sets  
Table 33. R-APDU of the System File Select command  
–
Data  
SW1  
SW2  
Comment  
Length  
Value  
Value  
–
–
–
1 byte  
0x90  
1 byte  
0x00  
0x82  
–
Command completed  
0x6A  
Capability container not found, no data is returned  
5.6.7  
ReadBinary command  
On receiving the ReadBinary command, the M24SR02-Y reads the requested memory field  
and sends back its value in the R-APDU response.  
Before sending a ReadBinary command, a file must be selected by using a Select  
command.  
The Response of the ReadBinary command is successful when the data to be read is within  
(a)  
the selected file
 
; in other words, when the sum of P1-P2 and Le fields is equal to or lower  
than the selected file length.  

T

defines the ReadBinary command.  
Table 34. C-APDU of the ReadBinary command  
Name  
CLA  
INS  
P1 and P2  
Lc  
Data  
Le  
–
0x00  
0xB0  
2 bytes  
–
–
1 byte  
Class byte  
Read instruction code  
Offset in the file selected  
–
–
Number of bytes to read between  
0x01
≤
Le
≤
max(Selected File length, 0xF6)  

T

defines the R-APDU of the ReadBinary command.  
Table 35. R-APDU of the ReadBinary command  
–
Data  
SW1  
SW2  
Comment  
Length  
Value  
Value  
Value  
–
1 byte  
0x90  
0x67  
0x69  
1 byte  
–
Content read  
Don’t care

(1)

Command completed  
–
–
0x00  
0x82  
Wrong length  
Security status not satisfied  
a. For
 
more details about CC file, refer to

.  
For more details about NDEF file, refer to

.  
For more details about System file, refer to

.  
DS9985 Rev 12  
41/88  
78  
 
 
 
 
 
 

I²C and RF command sets  
M24SR02-Y  
Table 35. R-APDU of the ReadBinary command (continued)  
–
Data  
SW1  
SW2  
Comment  
Value  
Value  
–
–
0x6A  
0x6E  
0x82  
0x00  
File or application not found  
Class not supported  
1. For
 
more information, please contact your local ST support.  
5.6.8  
UpdateBinary command  
On receiving the UpdateBinary command, the M24SR02-Y writes the data field into the  
selected file and sends back a status in the R-APDU response. If needed, the device will  
request a timing extension (see

).  
Before sending an UpdateBinary command, a file must be selected by issuing a Select  
command.  

T

defines the UpdateBinary command.  
Table 36. C-APDU of the UpdateBinary command  
Name  
CLA  
INS  
P1 and P2  
Lc  
Data  
Le  
–
0x00  
0xD6  
2 bytes  
1 byte  
Lc bytes  
–
Class byte  
Write instruction code  
Offset in the file selected  
Number of bytes of data (0x01
≤
Lc
≤
0xF6)  
Data to write in the M24SR02-Y memory  
–

T

defines the R-APDU of the UpdateBinary command.  
Table 37. R-APDU of the UpdateBinary command  
–
Data  
SW1  
SW2  
Comment  
Length  
Value  
Value  
Value  
Value  
Value  
Value  
–
–
–
–
–
–
–
1 byte  
0x90  
0x65  
0x67  
0x69  
0x6A  
0x6E  
1 byte  
0x00  
0x81  
0x00  
0x82  
0x82  
0x00  
–
Command completed  
Unsuccessful updating  
Wrong length  
Security status not satisfied  
File or application not found  
Class not supported  
Note:  
Chaining is not supported on “UpdateBinay” command. For further return codes and  
definitions, refer to

.  
42/88  
DS9985 Rev 12  
 
 
 
 

M24SR02-Y  
I²C and RF command sets  
5.7  
ISO/IEC 7816-4 commands  
The ISO/IEC 7816-4 command set offers some extended features such as the protection of  
the NDEF file. This command set is used to manage the right access of the NDEF file.  
5.7.1  
Verify command  
The Verify command has two functions:  
1. check
 
if a password is required to access to the NDEF file (the LC field = 0x00)  
2. check
 
that the password embedded in the Verify command enables the access to the  
memory (the Lc field = 0x10 and the password is present).  
When the Lc field is equal to 0x00, the verify command returns a success code (0x90 00)  
provided that the access to the NDEF file does not require a password. When the access to  
the NDEF file is protected, the response to the Verify command returns an error code  
(0x63 00).  
When the Lc field equals 0x10, on receiving the Verify command, the M24SR02-Y  
compares the requested password with the data contained in the request and reports  
whether the operation has been successful in the response.  
Before sending this command, an NDEF file must be selected by issuing the NDEF Select  
command. Thus, this command checks the right access condition of the last NDEF file  
selected.  
After a successful command, an access is granted for the whole NDEF file.  

T

defines the Verify command.  
Table 38. Verify command format  
Name  
CLA  
INS  
P1 and P2  
Lc  
Data  
Le  
–
0x00  
0x20  
2 bytes  
1 byte  
Lc bytes  
–
Class byte  
Instruction code  
Password identification  
0x0001: Read NDEF password transmit  
0x0002: Write NDEF password transmit  
0x0003: I²C password transmit

(1)  

Other: RFU  
0x00: the password is not present  
0x10: the password is present in the data field  
Password  
–
1. This
 
code can only be issued by the I²C host.  
DS9985 Rev 12  
43/88  
78  
 
 
 

I²C and RF command sets  
M24SR02-Y  

T

defines the R-APDU of the Verify command.  
Table 39. R-APDU of the Verify command  
SW1 SW2
 
Comment  
1 byte
 
1 byte  
–
Data  
Length  
Value  
–
–
–
0x90  
0x69  
0x00  
0x85  
Command completed, the password is correct  
The conditions of use are not satisfied (e.g. no  
NDEF file was selected)  
Value  
–
Value  
Value  
Value  
Value  
–
–
–
–
0x69  
0x69  
0x6A  
0x63  
0x81  
0x82  
0x80  
0x00  
Cmd incompatible with file structure  
Security status not satisfied  
Incorrect parameter in cmd data field  
A password is required  
The password transmitted is incorrect and X  
encodes the number of further allowed retries.  
Value  
Value  
–
–
0x63  
0x6E  
0xCX

(1)  

0x00  
Class not supported  
1. At
 
each session, the RF host can check a password 3 times.  
5.7.2  
Change Reference Data command  
The Change Reference Data command replaces the read or write password related to the  
NDEF files previously selected. It can be performed only if the security status satisfies the  
security attributes for this command.  
Before sending this command, the verify command with the correct NDEF write password  
must be issued. Thus, this command changes the reference data of the NDEF file.  

T

defines the Change Reference Data command.  
Table 40. Change reference data command format  
Name  
CLA  
INS  
P1 and P2  
Lc  
Data  
Le  
–
0x00  
0x24  
2 bytes  
1 byte  
Lc bytes  
–
Class byte  
Instruction code  
Password identification  
0x0001: Read password transmit  
0x0002: Write password transmit  
0x0003: I²C password transmit

(1)  

Other: RFU  
0x10: the password is present in the data field  
NDEF file or I²C Password  
–
1. This
 
code can only be issued by the I²C host.  
44/88  
DS9985 Rev 12  
 
 
 

M24SR02-Y  
I²C and RF command sets  

T

defines the R-APDU of the Change Reference Data command.  
Table 41. R-APDU of the Change Reference Data command  
–
Data  
SW1  
SW2  
Comment  
Length  
0
1 byte  
1 byte  
–
Command completed, the access right has  
been changed  
Value  
–
0x90  
0x00  
Value  
Value  
Value  
Value  
Value  
Value  
Value  
–
–
–
–
–
–
–
0x69  
0x65  
0x69  
0x6A  
0x6A  
0x6A  
0x6E  
0x81  
0x81  
0x82  
0x80  
0x82  
0x86  
0x00  
Command is incompatible with the file structure  
Unsuccessful updating  
Security status not satisfied  
CC file or System file selected  
File or application not found  
Incorrect P1 or P2 values  
Class not supported  
5.7.3  
Enable Verification Requirement command  
The Enable Verification Requirement command activates the protection by password of the  
NDEF file. When this command is successful, the read or write access to the NDEF file is  
protected by a 128-bit password. It can be performed only if the security status satisfies the  
security attributes for this command.  
This command can update the right access of the NDEF file by writing into the EEPROM. In  
this case, the response timing will be around 5 ms.  
Before sending this command, the verify command with the correct NDEF write password  
must be issued. Thus, this command changes the access right of the NDEF file.  

T

defines the Enable Verification requirement command.  
Table 42. Enable Verification Requirement command format  
Name  
CLA  
INS  
P1 and P2  
Lc  
Data  
Le  
–
0x00  
0x28  
2 bytes  
–
–
–
Class byte  
Instruction code  
New security attributes  
0x0001: Enable the read protection of the NDEF file  
0x0002: Enable the write protection of the NDEF file  
Other: RFU  
–
–
–
The last five bits identify the password sent in the Verify command.  
DS9985 Rev 12  
45/88  
78  
 
 
 

I²C and RF command sets  
M24SR02-Y  

T

defines the R-APDU of the Enable Verification Requirement command.  
Table 43. R-APDU of the Enable Verification Requirement command  
–
Data  
SW1  
SW2  
Comment  
Length  
Value  
Value  
Value  
Value  
Value  
Value  
0
–
–
–
–
–
–
1 byte  
0x90  
0x69  
0x69  
0x6A  
0x6A  
0x6A  
1 byte  
0x00  
0x81  
0x82  
0x80  
0x82  
0x86  
–
Command completed, the password is correct  
Command is incompatible with the file structure  
Security status not satisfied  
CC file or System file selected  
File or application not found  
Incorrect P1 or P2 values  
5.7.4  
Disable Verification Requirement command  
The Disable Requirement command deactivates the protection by password of the NDEF  
file. When this command is successful, the read or write access to the NDEF file is granted  
without security requirements. It can be performed only if the security status satisfies the  
security attributes for this command.  
Before sending this command, the verify command with the correct NDEF write password  
must be issued. Thus, this command changes the access right of the NDEF file.  
This command can update the right access of the NDEF file by writing into the EEPROM. In  
this case, the response timing will be around 6 ms.  

T

defines the Disable Verification Requirement command.  
Table 44. Disable Verification Requirement command format  
Name  
CLA  
INS  
P1 and P2  
Lc  
Data  
Le  
–
0x00  
0x26  
2 bytes  
–
–
–
Class byte  
Instruction code  
New security attributes  
0x0001: Disable the read protection of the NDEF file  
0x0002: Disable the write protection of the NDEF file  
Other: RFU  
–
–
–

T

defines the R-APDU of the Disable Verification Requirement command.  
46/88  
DS9985 Rev 12  
 
 
 

M24SR02-Y  
I²C and RF command sets  
Table 45. R-APDU of the Disable Verification Requirement command  
–
Data  
SW1  
SW2  
Comment  
Length  
Value  
Value  
Value  
Value  
Value  
Value  
Value  
Value  
0
–
–
–
–
–
–
–
–
1 byte  
0x90  
0x69  
0x69  
0x6A  
0x6A  
0x6A  
0x6E  
0x65  
1 byte  
0x00  
0x81  
0x82  
0x80  
0x82  
0x86  
0x00  
0x81  
–
Command completed, the password is correct  
Command is incompatible with the file structure  
Security status not satisfied  
CC file or System file selected  
File or application not found  
Incorrect P1 or P2 values  
Class not supported  
Update failed  
5.8  
ST proprietary command set  
The RF or I²C host can be issued with the command set described in this section.  
5.8.1  
ExtendedReadBinary command  
On receiving the ExtendedReadBinary command, the M24SR02-Y reads the requested  
memory field and sends back its value in the R-APDU response.  
Before sending an ExtendedReadBinary command, a file must be selected by issuing an  
NDEF select command.  
The response of the ExtendedReadBinary command will be successful even if the data to  
be read is beyond the NDEF message. The command returns an error code if the data to be  
read goes beyond the end of the file.  
Table 46. C-APDU of the ExtendedReadBinary command  
Name  
Length  
ST Class byte  
CLA  
INS  
P1 and P2  
Lc  
Data  
Le  
0xA2  
0xB0  
2 bytes  
–
–
1 byte  
Read instruction code  
Offset in the file selected  
–
–
–
Number of bytes to read between 0x01
≤
Le
≤
0xF6  

T

defines the R-APDU of the read binary command.  
DS9985 Rev 12  
47/88  
78  
 
 
 
 
 

I²C and RF command sets  
M24SR02-Y  
Table 47. R-APDU of the ExtendedReadBinary command  
Data SW1 SW2
 
Comment  
Length Le
 
bytes 1
 
byte  
–
1 byte  
0x90  
0x67  
0x69  
0x6A  
0x6A  
0x6E  
–
Value  
Value  
Value  
Value  
Value  
Value  
Content read  
Don’t care

(1)  

Command completed  
Wrong length  
–
–
–
–
–
0x00  
0x82  
Security status not satisfied  
File or application not found  
Incorrect P1 or P2 values  
Class not supported  
0x82  
0x86  
0x00  
1. For
 
more information, please contact your local ST support.  
5.8.2  
EnablePermanentState command  
The command configures the NDEF file to the ReadOnly or to the WriteOnly State.  
This command can update the right access to the NDEF file by writing into the EEPROM. In  
this case, the response timing will be around 6 ms.  

T

defines the EnablePermanentState requirement command.  
Table 48. EnablePermanentState command format  
Name  
Length  
CLA  
INS  
P1 and P2  
Lc  
Data  
Le  
0xA2  
0x28  
2 bytes  
–
–
–
Class byte  
Instruction code  
New security attributes  
0x0001: Enable the read protection of the NDEF file  
0x0002: Enable the write protection of the NDEF file  
Other: RFU  
–
–
–
–

T

defines the R-APDU of the EnablePermanentState command.  
Table 49. R-APDU table of the EnablePermanentState command  
–
Data  
SW1  
SW2  
Comment  
Length  
Value  
Value  
Value  
–
–
–
–
1 byte  
0x90  
0x65  
0x67  
1 byte  
0x00  
0x81  
0x00  
–
Command completed  
Update failed  
Wrong length  
48/88  
DS9985 Rev 12  
 
 
 
 
 

M24SR02-Y  
I²C and RF command sets  
Table 49. R-APDU table of the EnablePermanentState command (continued)  
–
Data  
SW1  
SW2  
Comment  
Value  
Value  
Value  
Value  
Value  
–
–
–
–
–
0x69  
0x6A  
0x6A  
0x6A  
0x6E  
0x82  
0x80  
0x82  
0x86  
0x00  
Security status not satisfied  
CC file or System file selected  
File or application not found  
Incorrect P1 or P2 values  
Class not supported  
5.8.3  
DisablePermanentState command  
The command configures the NDEF file to the Lock state.  
This command can update the right access of the NDEF file by writing into the EEPROM. In  
2
this case, the response timing will be around 6 ms. This command is only valid in I
 
C. The  
SuperUser rights must have been granted to execute the command.  
Before sending this command, an NDEF file must be selected by issuing the NDEF Select  
command.  

T

defines the DisablePermanentState requirement command.  
Table 50. DisablePermanentState command format  
Name  
Length  
CLA  
INS  
P1 and P2  
Lc  
Data  
Le  
0xA2  
0x26  
2 bytes  
–
–
–
Class byte  
Instruction code  
New security attributes  
0x0001: Disable the read protection of the NDEF file  
0x0002: Disable the write protection of the NDEF file  
Other: RFU  
–
–
–

T

defines the R-APDU of the DisablePermanentState command.  
Table 51. R-APDU of the DisablePermanentState command  
–
Data  
SW1  
SW2  
Comment  
Length  
Value  
Value  
Value  
Value  
–
–
–
–
–
1 byte  
0x90  
0x65  
0x67  
0x69  
1 byte  
0x00  
0x81  
0x00  
0x82  
–
Command completed  
Update failed  
Wrong length  
Security status not satisfied  
DS9985 Rev 12  
49/88  
78  
 
 
 
 

I²C and RF command sets  
M24SR02-Y  
Table 51. R-APDU of the DisablePermanentState command (continued)  
–
Data  
SW1  
SW2  
Comment  
Value  
Value  
Value  
Value  
–
–
–
–
0x6A  
0x6A  
0x6A  
0x6E  
0x80  
0x82  
0x86  
0x00  
CC file or System file selected  
File or application not found  
Incorrect P1 or P2 values  
Class not supported  
5.8.4  
UpdateFileType command  
This command allows to modify the file type of a selected file to Proprietary file (0x05) or  
NDEF file (0x04).  
NFC Forum compatible tags must configure the file as NDEF file (0x04).  
This command is granted only, when application and file are selected and if the file length  
and access right have previously been set to 0X00h (message invalid, all access rights  
granted).  
This command will update the file type located in the CC file by writing into the EEPROM. In  
this case, the response timing will be around 6 ms.  

T

defines the UpdateFileType command.  
Table 52. UpdateFileType command format  
Name  
Value  
Class byte  
CLA  
INS  
P1  
P2  
Lc  
Data  
Le  
0x04 or  
0x05  
0xA2  
0xD6  
0x00  
0x00  
0x01  
–
Select instruction code  
P1 field  
P2 field  
Number of bytes of data  
File type  
–

T

describes the R-APDU of the UpdateFileType command.  
Table 53. R-APDU of the UpdateFileType command  
–
Data  
SW1  
SW2  
Comment  
Length  
Value  
Value  
Value  
–
–
–
–
1 byte  
0x90  
0x69  
0x6A  
1 byte  
0x00  
0x82  
0x80  
–
Command completed  
Security status not satisfied  
CC file or System file selected  
50/88  
DS9985 Rev 12  
 
 
 
 

M24SR02-Y  
I²C and RF command sets  
Table 53. R-APDU of the UpdateFileType command (continued)  
–
Data  
SW1  
SW2  
Comment  
File or application not found  
Incorrect P1 or P2 values  
Value  
Value  
–
–
0x6A  
0x6A  
0x82  
0x86  
5.8.5  
SendInterrupt command  
On receiving the SendInterrupt command, the M24SR02-Y generates a negative pulse on  
the GPO pin. It starts at the end of the command and ends at the end of the RF response.  
Before sending this command, the system file must be selected by issuing the System  
Select command.  

T

defines the SendInterrupt command.  
Table 54. SendInterrupt command format  
–
CLA  
INS  
P1&P2  
Lc  
Data  
Le  
Length  
Value  
1 byte  
0xA2  
1 byte  
0xD6  
2 bytes  
0x001E  
1 byte  
0x00  
–
–
–
–

T

describes the R-APDU of the SendInterrupt command.  
Table 55. R-APDU of the SendInterrupt command  
Data  
SW1  
SW2  
Comment  
Length  
Value  
Value  
Value  
Value  
Value  
–
–
–
–
–
–
1 byte  
0x90  
0x6A  
0x6A  
0x6A  
0x6E  
1 byte  
0x00  
0x80  
0x82  
0x86  
0x00  
–
The interrupt has been sent  
The GPO is not configured as an interrupt mode  
File or application not found  
Incorrect P1 or P2 values  
Class not supported  
5.8.6  
StateControl command  
On receiving the StateControl command with reset value: data 0x00, the M24SR02-Y drives  
the GPO pin low. On receiving the StateControl command with set value: data 0x01, the  
M24SR02-Y releases the GPO pin, which returns to HZ.  
Before sending this command, the system file must be selected by issuing the System  
Select command.  

T

defines the StateControl command.  
DS9985 Rev 12  
51/88  
78  
 
 
 
 
 

I²C and RF command sets  
M24SR02-Y  
Le  
Table 56. StateControl command format  
–
CLA  
INS  
P1&P2  
Lc  
Data  
Length  
1 byte  
0xA2  
0xA2  
1 byte  
0xD6  
0xD6  
2 bytes  
0x001F  
0x001F  
1 byte  
0x01  
0x01  
–
–
–
–
Reset value  
Set value  
0x00  
0x01  
Table 57. R-APDU of the StateControl command  
–
Data  
SW1  
SW2  
Comment  
Length  
Value  
Value  
Value  
Value  
Value  
–
–
–
–
–
–
1 byte  
0x90  
0x6A  
0x6A  
0x6A  
0x6E  
1 byte  
0x00  
0x80  
0x82  
0x86  
0x00  
–
The set or reset has been sent  
The GPO is not configured in StateControl mode  
File or application not found  
Incorrect P1 or P2 values  
Class not supported  
5.9  
Specific RF command set  
This section describes the command set that can be issued only by the RF host.  
5.9.1  
Anticollision command set  

T

lists the commands that can be issued only by the RF host. The format of these  
commands is described in the NFC Forum Digital Protocol specification.  
Table 58. Commands issues by the RF host  
Family command set  
Command name  
Instruction code  
0x52

(1)  

ALL_REQ  
SENS_REQ  
SDD_REQ  
SEL_REQ  
SLP_REQ  
0x26

NFC-A technology  
1. Coded
 
on 7 bits.  
0x93 or 0x95 or 0x97  
0x93 or 0x95 or 0x97  
0x50  
5.9.2  
RATS command and ATS response  
RATS command and ATS response are used for NFC Forum Type 4A
T
a
g Platform Device  
Activation (as defined in NFC Forum Digital Protocol specification).  

T

details the RATS command. This command must be sent after the anticollision  
process.  
52/88  
DS9985 Rev 12  
 
 
 
 
 
 
 
 

M24SR02-Y  
I²C and RF command sets  
Table 59. RATS command  
Param  
Name  
Byte field  
Bit field  
INS  
0xE0  
–
CRC  
1 byte  
b7-b4  
2 bytes  
b3-b0  
–
Instruction code  
FSDI  
DID (0
≤
DID
≤
14)  
2 CRC bytes  
The FSDI field codes the FSD that defines the maximum size that an RF or I²C host is able  
to receive.

gives the conversion from FDSI to FSD.  
Table 60. Conversion from FDSI to FSD  
0x9h-  
FSDI  
0x0  
0x1  
0x2  
0x3  
0x4  
0x5  
0x6  
0x7  
0x8  
0xF  
0xE  
FSD  
16  
24  
32  
40  
48  
64  
96  
128  
256  
RFU  
256  
The DID field defines the value of the addressed M24SR02-Y.  
Table 61. ATS response  
Name  
Byte field  
Bit field  
TL  
0x05  
–
T0  
0x78  
–
TA(1)  
1 byte  
–
TB(1)  
TC(1)  
CRC  
2 bytes  
–
1 byte  
0x02  
–
b8-b5  
b4-b1  
Length of the ATS  
response  
FSCI = 256 bytes  
The maximum ascending data rate is 106 kbps  
The maximum descending data rate is 106 kbps  
FWI field (9.6 ms when TB = 0x50)  
SFGI field (302 µs when TB = 0x50)  
The DID is supported  
2 CRC bytes  
The FSCI codes the FSC, which stands for the maximum frame size that the M24SR02-Y is  
able to receive. The M24SR02-Y is able to receive up to 256 bytes of command. If the RF or  
I²C host sends a command with more than 256 bytes, the M24SR02-Y will not be able to  
treat the command and will not reply.  
The FWI, which stands for the frame waiting time integer codes the FW
T
.
T
his time  
corresponds to the maximum duration while an RF or I²C host must wait before sending the  
next command.  
DS9985 Rev 12  
53/88  
78  
 
 
 
 

I²C and RF command sets  
M24SR02-Y  
The SFGI, which stands for the start-up frame guard time is the minimum time that the  
reader must wait after receiving the response of the M24SR02-Y.  
5.9.3  
PPS command and response  
PPS (protocol and parameter selection) command and response are defined in ISO/IEC  
14443-4, in the protocol activation of PICC Type A.  
The PPS command makes possible to change the data rates of the ascending (RF host to  
M24SR02-Y) and descending (M24SR02-Y to RF host) data rates.  
Table 62. PPS command  
Name  
Byte field  
Bit field  
INS  
PPS0  
0x11  
–
PPS1  
1 byte  
b3-b2  
CRC  
2 bytes  
–
–
0xDX  
b7-b4  
b3-b0  
0b0000  
b1-b0  
Instruction code  
DID  
INS  
–
PPS1 is present  
RFU  
PPS1 Descending
 
data rate  
Ascending data rate  
–
2 CRC bytes  
The ascending and descending data rates must be coded as described in

.  
Table 63. Ascending and descending data rate coding  
Value  
0b00  
0b01  
0b10  
0b11  
Data rate  
106 kbps  
RFU  
RFU  
RFU  
When the M24SR02-Y is able to change both data rates, it returns the following response.  
The data rate of this response is 106 kbps; then, the M24SR02-Y changes the ascending  
and descending data rates.  

T

gives the details of the PPS response.  
Table 64. PPS response  
Name  
Byte field  
Bit field  
INS  
–
–
PPS0  
0x11  
0xDX  
b8-b5  
b4-b1  
Response code  
DID field  
2 CRC bytes  
54/88  
DS9985 Rev 12  
 
 
 
 

M24SR02-Y  
I²C and RF command sets  
5.10  
Specific I
²
C command set  

T

lists the commands that can only be issued by the I²C host.  
Table 65. Specific I
²
C commands  
Command name
 
Format Class
 
byte Instruction
 
code  
Brief description  
Open an I
²
C session when the  
RF session is not ongoing  
GetI2Csession  
KillRFsession  
–
–
–
–
0x26  
0x52  
Kill the RF session and open an  
I
²
C session  
5.10.1  
GetI2Csession command  
The GetI2Csession command opens an I²C session if an RF session is not ongoing.  

T

defines the GetI2Csession command.  
Table 66. GetI2Csession command format  
–
INS  
Length  
Value  
1 byte  
0x26  
The GetI2Csession command does not create a reply.  
When an RF session is ongoing, the M24SRxx will not acknowledge the command.  
When no RF session is ongoing, the M24SRxx will acknowledge the command and open an  
I²C session.  
5.10.2  
KillRFsession command  
The KillRF session command closes the RF session and opens an I²C session.  

T

defines the KillRFsession command.  
Table 67. KillRFsession command format  
–
INS  
Length  
Value  
1 byte  
0x52  
The KillRFsession command does not create a reply. The RF session is closed when the  
device acknowledges the command.  
Caution:  
A successful completion of the RF command is not certain.  
DS9985 Rev 12  
55/88  
78  
 
 
 
 
 
 

RF device operation  
M24SR02-Y  
6
RF device operation  
6.1  
Anticollision and Device activation command set for the RF  
interface  
The M24SR02-Y device supports the command set defined in the NFC-A
T
e
chnology and  
the Type 4A
T
a
g Platform chapters of the NFC Digital Protocol V1.0 specification.  
6.2  
Open an RF session  
Once the RF host has terminated the anticollision procedure and retrieve the ATS response,  
it must send the SelectApplication command. The M24SR02-Y will open an RF session. At  
this point, the RF host can send the applicative command set and the I²C cannot  
2
communicate with the M24SR02-Y without closing first the RF session using the I C  
KillRFsession command.  
6.3  
6.4  
Close an RF session  
The RF host can close the RF session through one of these methods:  
•
•
send an S(DES) command  
turn off the RF field.  
Applicative command set  
The applicative command set is composed of the following command sets:  
•
•
•
the NFC Forum Type 4
T
a
g command set  
the ISO/IEC 7816-4 command set  
the proprietary command set.  
56/88  
DS9985 Rev 12  
 
 
 
 
 

M24SR02-Y  
I2C device operation  
2
7
I C
 
device operation  
2
The M24SR02-Y device supports the I
 
C protocol. The device that controls the data transfer  
is known as the bus master, and the other one as the slave device. A data transfer can only  
be initiated by the bus master, which also provides the serial clock for synchronization. The  
M24SR02-Y device is a slave in all communications.  
7.1  
I

2

C communication protocol  
2
2
The I C communication is built on a system of command and reply exchange. The I
 
C host  
starts the communication by sending a request. Once a valid request is received by the  
M24SR02-Y device, it carries out an internal operation and creates its answer.  
As defined in this document, and except for the GetI2C session and Kill RF session  
commands, the definition of a valid request is a command with a right CRC value.  

Figure 12

shows an exchange of a command and a response between the I²C host and the  
M24SR02-Y. Once the I²C session is open, the I²C host can send a command. The  
command is composed of:  
•
•
a Device Select field with the R/W bit set to 0  
the command field.  
The M24SR02-Y acknowledges on the reception of each byte.  
Once the M24SR02-Y is ready to send the answer, the I²C host must:  
•
•
send a Device Select field with the R/W bit set to 1  
release the SDA line and send an SCL clock.  
The I²C host must acknowledge on the reception of each byte.  
Figure 12. Command and response exchange  
,ꢁ&ꢄEXV
 
5ꢅ:ꢄ ꢄꢊ
 
5ꢅ:ꢄ ꢄꢂ
 
‘HYLFH6HOHFW
 
&RPPDQG
 
3
6
‘HYLFH6HOHFW
 
5HVSRQVH
 
3
6
06ꢀꢊꢈꢍꢁ9ꢂ
 
Legend:  
2
S is the I C Start bit sequence  
P is the I C Stop bit sequence  
R/W is the 8
 
bit of Device Select.  
2
th  
Note:  
A restart during a command and response exchange is not supported by the M24SR02-Y.  
2
After a command, the I
 
C host can execute a Polling sequence to determine when the  
response is available.  
Polling sequence: Loop on
 
< START (S) + DeviceSelect with RW=0 + read NACK/ACK  
+ STOP (P) >  
The response is available as soon as the M24SR02-Y sends an ACK ( host read will a  
‘0’).  
DS9985 Rev 12  
57/88  
78  
 
 
 
 
 

I2C device operation  
M24SR02-Y  
7.2  
Start condition  
A Start condition is identified by a falling edge of serial data (SDA) while the serial clock  
(SCL) is stable in the high state. A Start condition must precede any data transfer command.  
The device continuously monitors (except during an instruction processing) the SDA and the  
SCL for a Start condition, and does not respond unless one is given.  
7.3  
7.4  
Stop condition  
A Stop condition is identified by a rising edge of serial data (SDA) while the serial clock  
(SCL) is stable and driven high. A Stop condition terminates a command between the device  
and the bus master.  
I²C token release sequence  
As explained in the M24SR02-Y session mechanism, the I²C communication is reserved to  
the I²C host when the session token has the I²C value.  
The following sequence explains how to release the I²C value of the session token.  
I²C communication with the M24SR02-Y starts with a valid Start condition, followed by a  
device select code.  
If the delay between the Start condition and the following rising edge of the Serial Clock  
(SCL) that samples the most significant of the Device Select exceeds the t  
START_OUT_MAX  
time (see

), the I²C logic block is reset and further incoming data transfer is ignored  
until the next valid Start condition.  
Figure 13. I²C token release sequence  
ꢄ
!ꢄW

67$57B287BPD[ꢄ
 

6&/
 
6’$
 
0ꢁꢆ65ꢄ’HYLFHꢄ
 
6HOHFWꢄFRGH
 
6WDUWꢄ
 
FRQGLWLRQ
 
6WRSꢄ
 
FRQGLWLRQ
 
06Yꢆꢀꢊꢍꢈ9ꢂ
 
2
Note:  
If the above delay is below t  
unmodified.  
(see

), I
 
C session token stays  
START_OUT_min  
2
If the delay is between t  
and t  
, I C session token might or not  
START_OUT_min  
START_OUT_max  
be released. This range of delay is not authorized for safe operation.  
58/88  
DS9985 Rev 12  
 
 
 
 
 
 

M24SR02-Y  
I2C device operation  
7.5  
I²C timeout on clock period  
2
During a data transfer on the I
 
C bus, if the serial clock high pulse or serial clock low pulse  
2
exceeds t  
value that is the maximum value specified in

, the I
 
C logic  
CL_RESET  
block is reset and any further incoming data transfer is ignore

xt valid Start  
condition.  
If the serial clock high pulse is under the maximum value of
t

CHCL

and the serial clock low  
2
pulse is under the maximum value of t  
in

, the I
 
C logic block is not reset.  
CLCH  
For proper operation, the serial clock high pulse must not be higher than
t

CHCL

and lower  
than t
 
, and the serial clock low pulse must not be higher than
t

CHCH

and lower  
CL_RESET  
t
.
CL_RESET  
7.6  
Acknowledge bit (ACK)  
The acknowledge bit is used to indicate a successful byte transfer. The bus transmitter,  
whether a bus master or a slave device, releases the serial data (SDA) after sending eight  
bits of data. During the 9th clock pulse period, the receiver pulls the SDA low to  
acknowledge the receipt of the eight data bits.  
7.7  
7.8  
Data input  
During data input, the device samples serial data (SDA) on the rising edge of the serial clock  
(SCL). For a correct device operation, the SDA must be stable during the rising edge of the  
SCL, and the SDA signal must change only when the SCL is driven low.  
I²C device address  
2
The device address is the concatenation of the group number coded on 4 bits and the I C  
address coded on 3 bits, as shown in

.  
2
Table 68. I
 
C device address format  
b7-b4  
b3  
1
b2  
1
b1  
0
b0  
–
0b1010  
0bx  
Group number  
E2 bit  
E1 bit  
E0 bit  
0 = Request  
1 = Answer  
DS9985 Rev 12  
59/88  
78  
 
 
 
 
 
 

I2C device operation  
M24SR02-Y  
7.9  
I²C frame format  
2
The I
 
C frame is composed of three fields:  
1. SOD
 
field: contains the device select and the PCB. The PCB field is detailed in  
2
2. Payload
 
field: contains the command and its parameter, as defined in the I
 
C command  
set.  
3. EOD
 
field: contains the two CRC bytes computed on the SOD but excluding the device  
select byte field.  
2

T

shows the format of an I
 
C frame.  
2
Table 69. I C frame format  
SOD  
Payload  
EOD  
I

2

C frame  
0xAC or 0xAD  
1 byte  
1 to 251 bytes  
2 bytes  
Device select  
0xAC: to send a request to the M24SR02-Y  
0xAD: to read a response of the M24SR02-Y  
PCB field  
I

2

C command or I

2

C answer  
2 CRC bytes  
7.9.1  
Example of I²C frame commands  
NDEF Tag Application command  
2
2
This example presents the I
 
C frame of an NDEF
T
a
g Application Select command. The I
 
C  
frame is detailed in

.  
2
Table 70. I C host to M24SR02-Y  
Field  
SOD  
Payload  
EOD  
Value  
0xAC  
0x02 or 0x03  
Command field  
35 C0 or DF BE  
Device select  
PCB field  
0x00 A4 04 00 07 D2 76 00 00 85 01 01 00  
2 CRC bytes  
2
2
Before sending a new command, the I
 
C host can send an I C frame to read the  
M24SR02-Y answer to the NDEF tag Application Select command.  
60/88  
DS9985 Rev 12  
 
 
 
 
 
 

M24SR02-Y  
I2C device operation  
2
Table 71. M24SR02-Y to I C host  
SOD  
Payload  
M24SR02-Y to I

2

C host  
EOD  
Field  
I

2

C host to M24SR02-Y  
0xAD  
Value  
0x02 or 0x03  
0x90 00  
F1 09 or 2D 53  
Device select  
PCB field  
I

2

C command  
2 CRC bytes  
2

Figure 14

shows the I
 
C frame of the NDEF tag Application Select command.  
Figure 14. NDEF tag Application Select command  
6WDUWꢄRIꢄWKHꢄ
 
WUDQVPLVVLRQꢄ
 
RIꢄWKHꢄUHTXHVW
 
,ð&ꢄEXV
 
6
$&.
 
$&.
 
$&.
 
$&.
 
$&.
 
$&.
 
$&.
 
$&.
 
$&.
 
$&.
 
$&.
 
$&.
 
$&.
 
$&.
 
͘͘͘  
Ϭdžꢃꢂ  
Ϭ
džϬϮ ϬdžϬϬ Ϭdžꢃϰ ϬdžϬϰ ϬdžϬϬ ϬdžϬϳ ϬdžꢀϮ Ϭdžϳϲ ϬdžϬϬ ϬdžϬϬ Ϭdžϴϱ ϬdžϬϭ ϬdžϬϭ  
(QGꢄRIꢄWKHꢄ
 
WUDQVPLVVLRQꢄ
 
RIꢄWKHꢄUHTXHVW
 
,ð&ꢄEXV
 
$&.
 
$&.
 
$&.
 
͘͘͘
ꢊ[ꢊꢊ
 
ꢊ
[ꢀꢉ
 
ꢊ[&ꢊ
 
W
6WDUWꢄRIꢄWKHꢄ
 
WUDQVPLVVLRQꢄ
 
RIꢄWKHꢄDQVZHU
 
ꢄŶĚꢁŽĨꢁƚŚĞꢁ  
ƚƌĂŶƐŵŝƐƐŝŽŶꢁ  
ŽĨꢁƚŚĞꢁƌĞƋƵĞƐƚ  
,ð&ꢄEXV
 
^
ꢃꢂ< ꢃꢂ< ꢃꢂ< ꢃꢂ< ꢃꢂ< ꢃꢂ<  
͘͘͘  
Ϭdžꢃꢀ ϬdžϬϮ ϬdžϵϬ ϬdžϬϬ Ϭdž&ϭ ϬdžϬϵ  
W
$&.
 
$&.
 
/HJHQG  
$FNQRZOHGJHꢄEꢄWKHꢄ,ð&ꢄKRVW
 
$FNQRZOHGJHꢄEꢄ0ꢁꢆ65[[ꢋ<
 
%WHꢄVHQWꢄEꢄWKHꢄ,ð&ꢄKRVW
 
%WHꢄVHQWꢄEꢄWKHꢄ0ꢁꢆ65[[ꢋ<
 
ꢊ[ꢊꢁ
 
ꢊ[ꢊꢊ
 
6
6WDUWꢄVHQWꢄEꢄWKHꢄ,ð&ꢄKRVW
 
6WRSꢄVHQWꢄEꢄWKHꢄ,ð&ꢄKRVW
 
3
06ꢀꢀꢃꢆꢀ9ꢂ
 
DS9985 Rev 12  
61/88  
78  
 
 

I2C device operation  
M24SR02-Y  
7.10  
Open an I²C session  
To
o
pen an I²C session, the I²C host must send either the GetSession command or the  
KillRFsession command. The GetSession Command opens an I²C session if an RF session  
in not currently opened.  
A KillRFsession command closes the current RF session if it exists, and opens an I²C  
session.  
When an I²C session is opened, the RF host cannot communicate with the M24SR02-Y and  
cannot close the I²C session.  
7.11  
Close the I²C session  
There are four ways to close an I²C session:  
•
•
•
•
turn off the Vcc power supply  
send the I²C token release sequence  
wait for the I²C watchdog when it is enabled  
wait for the I²C timeout on clock period.  
62/88  
DS9985 Rev 12  
 
 
 

M24SR02-Y  
Functional procedures  
8
Functional procedures  
This section describes some procedure to access the memory or manage its protection.  
8.1  
Selection of an NDEF message  
The RF or I²C host must use this procedure to detect the NDEF message inside an  
M24SR02-Y.  
The NDEF detection procedure is as follows:  
1. Open
 
an RF or an I²C session  
2. Send
 
the SelectNDEF
T
a
gApplication command  
3. Select
 
the CC file  
4. Read
 
the CC file  
5. Select
 
the NDEF file  
8.2  
Reading of an NDEF message  
The RF or I²C host executes the NDEF read procedure to read the NDEF file.  
1. Detect
 
successfully the NDEF file using the NDEF detection procedure  
2. Check
 
that the read access without any security is granted for the NDEF file from the  
information provided by the CC file  
3. Select
 
the NDEF file  
4. Read
 
the NDEF file  
Note:  
Reading the NDEF file must not go beyond the NDEF Length field (NLEN), which indicates  
the size of the NDEF message stored in the NDEF file.  
8.3  
Reading a locked NDEF file  
The RF or I²C host executes this procedure to read an NDEF file that has been previously  
locked.  
1. Select
 
the NDEF
T
a
g Application  
2. Select
 
the NDEF file  
3. Verify
 
the Read password by using the Verify command  
4. Read
 
the data in the NDEF file  
DS9985 Rev 12  
63/88  
78  
 
 
 
 
 
 

Functional procedures  
M24SR02-Y  
8.4  
Locking an NDEF file  
The RF or I²C host executes this procedure to protect an NDEF file.  
1. Select
 
the NDEF
T
a
g Application  
2. Check
 
the right access provided by the CC file  
3. Select
 
the NDEF file  
4. Transmit
 
the NDEF file Write password by using the Verify command  
5. Lock
 
the NDEF file by sending the Enable verification command.  
8.5  
8.6  
Unlocking an NDEF file  
The RF or I²C host executes this procedure to unlock an NDEF file that has been previously  
locked.  
1. Select
 
the NDEF
T
a
g Application  
2. Select
 
the NDEF file  
3. Verify
 
the NDEF file Write password or the I²C password by using the Verify command  
4. Unlock
 
the NDEF file by sending the Disable verification command.  
Reaching the read-only state for an NDEF file  
The RF or I²C host executes this procedure to reach the read-only state for an NDEF file.  
1. Select
 
the NDEF
T
a
g Application  
2. Select
 
the NDEF file  
3. Transmit
 
the NDEF file Write password or the I²C password by using the Verify  
command  
4. Send
 
an EnablePermanentState command as the Write access right of the previous  
Select NDEF file.  
8.7  
Changing an NDEF password procedure  
The RF or I²C host could use this procedure to change one NDEF password. it can be a  
Read or Write password.  
1. Select
 
the NDEF
T
a
g Application  
2. Select
 
the NDEF file  
3. Transmit
 
the NDEF file Write password or the I²C password by using the Verify  
command  
4. Change
 
the password by sending a ChangeReferenceData command.  
64/88  
DS9985 Rev 12  
 
 
 
 
 
 
 

M24SR02-Y  
Functional procedures  
8.8  
Changing a File type Procedure  
The RF or I²C host executes this procedure to change the File Type of a file for which all  
access rights were previously granted.  
1. Select
 
the NDEF
T
a
g Application  
2. Select
 
the File to be modified  
3. Set
 
the File Length to 0x00 using the UpdateBinary command  
4. Send
 
an UpdateFileType command with the New file Type as data.  
8.9  
Updating an NDEF file  
When there’s enough space in the file to update it with new content, the following steps must  
be followed to update the NDEF message:  
1. Select
 
the NDEF
T
a
g Application  
2. Select
 
the NDEF file  
3. Unlock
 
the NDEF file if necessary  
4. Write
 
the NDEF length to 0x0000 with the Update Binary command.  
5. Write
 
the NDEF message in the NDEF message field using one or more Update Binary  
commands.  
6. Write
 
the NDEF length of the NDEF message using the Update Update command.  
It is recommended the NDEF length is read back and checked against the desired value to  
ensure the Update sequence has been correctly performed.  
DS9985 Rev 12  
65/88  
78  
 
 
 

UID: unique identifier  
M24SR02-Y  
9
UID: unique identifier  
The M24SR02-Y is uniquely identified by a 7-byte unique identifier (UID). The UID is a  
read-only code and comprises:  
•
•
•
the IC manufacturer code on 1 byte (0x02 for STMicroelectronics)  
the product code on 1 byte  
a device number on 5 bytes.  

T

describes the UID format.  
Table 72. UID format  
0x02 0x82  
–
5 bytes  
IC manufacturer code  
M24SR02-Y product code  
Device number  
66/88  
DS9985 Rev 12  
 
 
 

M24SR02-Y  
Maximum ratings  
10  
Maximum ratings  
Stressing the device above the ratings listed in

may cause permanent damage to  
the device. These are stress ratings only and operation of the device at these or any other  
conditions above those indicated in the operating sections of this specification is not implied.  
Exposure to absolute maximum rating conditions for extended periods may affect the device  
reliability.  
Table 73. Absolute maximum ratings  
Symbol  
Parameter  
Min.  
Max.  
Unit  
T

A  

Ambient operating temperature  
-40  
15  
85  
25  
°C  
°C  
T

ST
G

, h

STG  

,
Sawn wafer on  
UV tape  
Storage conditions  
9

(1)  

months  
t

STG  

Kept in its original packing form  
UFDFPN8, SO8,  
TSSOP8  
T

STG  

Storage temperature  
–65  
15  
150  
°C  
Storage temperature  
Storage time  
Sawn bumped  
wafer (kept in its  
antistatic bag)  
25  
9
°C  
T

STG  

months  
Lead temperature  
during soldering  
UFDFPN8, SO8,  
TSSOP8  
T

LEAD  

V

IO  

See note

(2)  

°C  
I

2

C input or output range and GPO  
-0.50  
–
6.5  
V
(3)  
I

CC  

RF supply current AC0 – AC1  
100  
mA  
RF input voltage  
amplitude between AC0  
and AC1, GND pad left  
floating  
(3)  
V

MAX_1  

VAC0-VAC1  
–
10  
V
AC voltage between  
AC0 and GND, or AC1  
and GND  
VAC0-GND or  
VAC1-GND  
(3)  
V

MAX_2  

-0.5  
4.5  
V
V
V
Electrostatic discharge  
voltage (human body  
model)

(4)  

V

ESD  

AC0-AC1  
–
–
1000  
3500  
Electrostatic discharge  
voltage (human body  
model)

V

ESD  

Other pads  
1. Counted
 
from ST shipment date.  
2. Compliant
 
with JEDEC Std J-STD-020D (for small body, Sn-Pb or Pb assembly), the ST ECOPACK  
7191395 specification, and the European directive on Restrictions on Hazardous Substances (ROHS  
directive 2011/65/EU, July 2011).  
3. Based
 
on characterization, not tested in production. Maximum adsorbed power = 100 mW @ 7.5 A/m  
4. AEC-Q100-002
 
(compliant with JEDEC Std JESD22-A114A, C1 = 100 p
F
,
R
1 = 1500
ꢀ
, R2 = 500
ꢀ
)  
DS9985 Rev 12  
67/88  
78  
 
 
 
 

I2C DC and AC parameters  
M24SR02-Y  
2
11  
I C
 
DC and AC parameters  
This section summarizes the operating and measurement conditions, and the DC and AC  
2
characteristics of the device in I
 
C mode. The parameters in the DC and AC characteristic  
tables that follow are derived from tests performed under the measurement conditions  
summarized in the relevant tables. Designers must check that the operating conditions in  
their circuit match the measurement conditions when relying on the quoted parameters.  
2
Table 74. I C operating conditions  
Symbol  
Parameter  
Min.  
Max.  
Unit  
V

CC  

T

A  

Supply voltage  
Ambient operating temperature  
2.7  
5.5  
85  
V
– 40  
°C  
Table 75. AC test measurement conditions  
Symbol  
Parameter  
Min.  
Max.  
Unit  
C

L  

Load capacitance  
100  
pF  
ns  
V
t

r,

t

f  

Input rise and fall times  
Input levels  
–
50  
V

hi-lo  

V

ref(t)  

0.2 V

CC

to 0.8 V

CC  

0.3 V

CC

to 0.7 V

CC  

Input and output timing reference levels  
V
Figure 15. AC test measurement I/O waveform  
,QSXWꢄOHYHOV
 
,QSXWꢄDQGꢄRXWSXW
 
WLPLQJꢄUHIHUHQFHꢄOHYHOV
 
ꢊꢇꢃꢄ9
 
FF
 
ꢊꢇꢈꢄ9
 
ꢊꢇꢀꢄ9
 
FF
 
FF
 
ꢀꢁꢂ 6  
CC  
06ꢆꢈꢉꢊꢂ9ꢂ
 
Table 76. Input parameters  
Parameter  
Symbol  
Min.  
Max.  
Unit  
C

IN  

C

IN  

t

NS  

Input capacitance (SDA)  
–
–
–
8
6
pF  
pF  
ns  
Input capacitance (other pins)  
Pulse width ignored (Input filter on SCL and SDA)  
80  
68/88  
DS9985 Rev 12  
 
 
 
 
 
 
 

M24SR02-Y  
Symbol  
I2C DC and AC parameters  
2
Table 77. I C DC characteristics  
Parameter  
Test condition  
Min.  
Max.  
Unit  
Input leakage current  
(SCL, SDA)  
V

IN

= V

SS

or V

CC  

device in Standby mode  
I

LI  

–
± 2  
µA  
SDA in Hi-Z, external voltage applied on  
SDA: V
SS
or V
CC  
I

LO  

Output leakage current  
–
± 2  
µA  
V

CC

= 3.3
V
,
w
ith RF ON  

CC

= 3.3
V
,
w
ith RF OFF  

CC

= 5.5 V, with RF ON

(1)  

V

CC

= 5.5
V
,
w
ith RF OFF  

CC

= 3.3
V
,
w
ith RF ON  

CC

= 3.3
V
,
w
ith RF OFF  
V

CC

= 5.5
V
,
w
ith RF ON  
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
30  
5
V
Standby power mode supply  
current  
I

CC0  

I

CC1  

I

CC2  

I

CC3  

µA  
V
30  
5
V
150  
150  
150  
150  
250  
200  
250  
200  
550  
500  
550  
500  
V
Supply current  
µA  
µA  
µA  
(I

2

C Session open)  
V

CC

= 5.5
V
,
w
ith RF OFF  
V

CC

= 3.3 V (f

C

= 1 MHz), with RF ON

(3)  

Supply current

(2)  

(Read binary)  
V

CC

= 3.3 V (f

C

= 1 MHz), with RF OFF

(3)  

CC

= 5.5 V (f

C

= 1 MHz), with RF ON

(3)  

V

CC

= 5.5 V (f

C

= 1 MHz), with RF OFF

(3)  

CC

= 3.3 V (f

C

= 1 MHz), with RF ON

(3)  

CC

= 3.3 V (f

C

= 1 MHz),with RF OFF

(3)  

V
V
Supply current

(2)  

(Update binary)  
V
V

CC

= 5.5 V (f

C

= 1 MHz), with RF ON

(3)  

V

CC

= 5.5 V (f

C

= 1 MHz), with RF OFF

(3)  

V

CC

= 2.7 V  
V

IL  

V

IH  

V

IL  

V

IH  

Input low voltage (SDA, SCL)  
Input high voltage (SDA, SCL)  
Input low voltage (RF disable)  
Input high voltage (RF disable)  
-0.45  
0.7 V

CC  

–
0.3 V

CC  

6.5  
V
V
V
V
V

CC

= 5.5 V  
V

CC

= 2.7 V  
V

CC

= 5.5 V  
V

CC

= 2.7 V  
V

CC

= 5.5 V  
0.45  
–
V

CC

= 2.7 V  
1.4  
V

CC

= 5.5 V  
Output low voltage (SDA)  
Output low voltage (GPO)  
I

OL

= 3 mA, V

CC

= 5.5 V  

OL

= 1 mA, V

CC

= 2.7 to 5.5 V  
–
–
0.4  
0.4  
V
V
V

OL  

I
1. When
 
an RF session is Opened, I

cc

corresponds to the standby power mode.  
2. Characterized
 
only.  
3. Input
 
levels as defined in

.  
DS9985 Rev 12  
69/88  
78  
 
 

I2C DC and AC parameters  
M24SR02-Y  
2
Table 78. I
 
C AC characteristics (400 kHz)  
Test conditions specified in

(preliminary data based on design simulations)  
Symbol  
Alt.  
Parameter  
Min.  
Max.  
Unit  
f

C  

f

SCL  

t

HIGH  

t

LOW  

–
Clock frequency  
0.05  
0.6  
400  
kHz  
µs  
µs  
µs  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ms  
ms  
ns  
ms  
(1)  
t

CHCL  

Clock pulse width high  
Clock pulse width low  
Clock reset  
20000  
20000  
(2)  
t

CLCH  

1.3  
t

CL_reset  

t

XH1XH2  

t

XL1XL2  

t

DL1DL2  

t

DXCX  

40000  
–
(3)  
(3)  
t

R  

Input signal rise time  
Input signal fall time  
SDA (out) fall time  
(3)  
(3)  
t

F  

t

F  

20  
100  
0
300  
t

SU:DAT

Data in set up time  
t

HD:DAT

Data in hold time  
–
–
t

CLDX  

(4)  
t

CLQX  

t

DH  

t

AA  

Data out hold time  
100  
–
–
(5)  
t

CLQV  

Clock low to next data valid (access time)  
900  
–
(6)  
t

CHDX  

t

SU:STA

Start condition set up time  
t

HD:STA

Start condition hold time  
t

SU:STO

Stop condition set up time  
600  
600  
600  
1300  
–
t

DLCL  

t

CHDH  

t

DHDL  

–
–
t

BUF  

Time between Stop condition and next Start condition  
–
I²C write time in one page  
5
t

W  

t

WR  

I²C write time up to 246 bytes  
–
90  
80  
40  
(7)  
t

NS  

–
–
Pulse width ignored (input filter on SCL and SDA)  
Delay for I²C token release  
–
t

START_OUT  

20  
1. t

CHCL

timeout.  
2. t

CLCH

timeout.  
3. There
 
is no min. or max. value for the input signal rise and fall times. It is however recommended by the I²C specification that the input  
signal rise and fall times be more than 20 ns and less than 300 ns when f

C

< 400 kHz.  
4.
T
o
 
a
void spurious Start and Stop conditions, a minimum delay is placed between SCL=1 and the falling or rising edge of  
SDA.  
5. t

CLQV

is the time (from the falling edge of SCL) required by the SDA bus line to reach 0.8V

CC

in a compatible way with the  
I

2

C specification (which specifies t

SU:DAT

(min) = 100 ns), assuming that the R

bus

× C

bus

time constant is less than 500 ns  
(as specified in

).  
6. For
 
a restart condition, or following a write cycle.  
7. Characterized
 
only, not tested in production.  
70/88  
DS9985 Rev 12  
 
 
 

M24SR02-Y  
I2C DC and AC parameters  
2
Table 79. I C AC characteristics (1 MHz)  
Test conditions specified in

(preliminary data based on design simulations)  
Symbol  
Alt.  
Parameter  
Min.  
Max.  
Unit  
f

C  

f

SCL

Clock frequency  
0.05  
260  
1000  
–
kHz  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
(1)  
t

CHCL  

t

HIGH

Clock pulse width high  
t

LOW

Clock pulse width low  
(2)  
t

CLCH  

500  
–
(3)  
(3)  
t

XH1XH2  

t

XL1XL2  

t

DL1DL2  

t

DXCX  

t

R  

t

F  

t

F  

Input signal rise time  
Input signal fall time  
SDA (out) fall time  
(3)  
(3)  
20  
50  
120  
t

SU:DAT

Data in set up time  
t

HD:DAT

Data in hold time  
–
t

CLDX  

0
–
t

CLQX  

t

DH  

t

AA  

Data out hold time  
100  
–
–
(4)(5)  
t

CLQV  

Clock low to next data valid (access time)  
450  
(6)  
t

CHDX  

t

SU:STA

Start condition set up time  
t

HD:STA

Start condition hold time  
t

SU:STO

Stop condition set up time  
250  
250  
250  
–
–
–
t

DLCL  

t

CHDH  

Time between Stop condition and next Start  
condition  
t

DHDL  

t

BUF  

t

WR  

–
500  
–
ns  
I²C write time in one page  
I²C write time up to 246 bytes  
–
–
5
ms  
ms  
t

W  

90  
Pulse width ignored (input filter on SCL and  
SDA)  
(7)  
t

NS  

–
80  
ns  
1. t

CHCL

timeout.  
2. t

CLCH

timeout.  
3. There
 
is no min. or max. value for the input signal rise and fall times. It is however recommended by the I²C  
specification that the input signal rise and fall times be less than 120 ns when f

C

< 1 MHz.  
4.
T
o
 
a
void spurious Start and Stop conditions, a minimum delay is placed between SCL = 1 and the falling or  
rising edge of SDA.  
5. t

CLQV

is the time (from the falling edge of SCL) required by the SDA bus line to reach 0.8V

CC

in a  
compatible way with the I

2

C specification (which specifies t

(min) = 100 ns), assuming that the R

bus  

× C

bus

time constant is less than 500 ns (as specified in

).  
6. For
 
a reStart condition, or following a write cycle.  
7. Characterized
 
only, not tested in production.  
DS9985 Rev 12  
71/88  
78  
 
 
 

I2C DC and AC parameters  
M24SR02-Y  
2
Figure 16. I C AC waveforms  
W
W
&+&/
 
;/ꢂ;/ꢁ
 
W
W
W
&/&+
 
;+ꢂ;+ꢁ
 
6&/
 
W
‘/&/
 
;/ꢂ;/ꢁ
 
6’$ꢄ,Q
 
W
W
W
‘;&+
 
6’$
 
&KDQJH
 
W
W
W
‘+’/
 
&+’/
 
6WDUW
 
FRQGLWLRQ
 
&/’;
 
;+ꢂ;+ꢁ
 
&+’+
 
6WDUW
 
6’$
 
,QSXW
 
6WRS
 
FRQGLWLRQ
 
FRQGLWLRQ
 
6&/
 
6’$ꢄ,Q
 
W
:
W
W
&+’+
 
&+’/
 
6WRS
 
FRQGLWLRQ
 
:ULWHꢄFFOH
 
6WDUW
 
FRQGLWLRQ
 
W
&+&/
 
6&/
 
W
W
W
4/ꢂ4/ꢁ
 
&/49
 
&/4;
 
‘DWDꢄYDOLG
 
‘DWDꢄYDOLG
 
6’$ꢄ2XW
 
06ꢆꢈꢉꢀꢁ9ꢂ
 
72/88  
DS9985 Rev 12  
 
 

M24SR02-Y  
I2C DC and AC parameters  
11.1  
I

2

C timing measurement condition  

Figure 17

represents the maximum R  
value versus bus parasitic capacitance (C
 
) for  
bus  
bus  

an I

m frequency f
 
= 400 kHz.  
C
Figure 17. Maximum Rbus value with f
 
= 400 kHz  
C
ꢃꢀꢀ  
4HE 2  
X #
 
TIME CONSTANT  
BUS  
BUS  
MUST BE BELOW THE ꢄꢀꢀ NS  
TIME CONSTANT LINE REPRESENTED  
ON THE LEFTꢁ  
6
##  
ꢃꢀ  
2
BUS  
(ERE 2  
BUS  
§ #
 
ꢋ ꢃꢂꢀ NS  
BUS  
ꢄ K
½
 
3#,  
3$!  
)£# BUS  
MASTER  
-ꢂꢄXXX  
ꢃ
ꢌꢀ P&  
#
BUS  
ꢃꢀ  
ꢃꢀꢀ  
“US LINE CAPACITOR ꢈP&ꢉ  
ꢃꢀꢀꢀ  
AIꢃꢄꢅꢆꢇB  

Figure 18

represents the Maximum Rbus value versus bus parasitic capacitance (Cbus) for  
an I
 
C bus at maximum frequency f
 
= 1 MHz.  
C
Figure 18. Maximum Rbus value with f
 
= 1 MHz  
C
6
ꢃ
ꢀ
ꢀ  
##  
2
BUS  
4HE 2  
§ #  
TIME CONSTANT  
BUS  
BUS  
MUST BE BELOW THE ꢃꢍꢀ NS  
TIME CONSTANT LINE REPRESENTED  
ON THE LEFTꢁ  
3#,  
3$!  
)£# BUS  
MASTER  
ꢃꢀ  
ꢄ
-ꢂꢄXXX  
(EREꢎ  
#
§
BUS  
ꢋ ꢃꢂꢀ NS  
#
2
BUS  
BUS  
ꢃ
ꢃꢀ  
ꢌꢀ  
“US LINE CAPACITOR ꢈP&ꢉ  
ꢃꢀꢀ  
-3ꢃꢆꢅꢄꢍ6ꢃ  
DS9985 Rev 12  
73/88  
78  
 
 
 
 

I2C DC and AC parameters  
M24SR02-Y  
2
Figure 19. I
 
C bus protocol  
6&/
 
6’$
 
6’$
 
,QSXW
 
6’$
 
&KDQJH
 
6WDUW
 
6WRS
 
FRQGLWLRQ
 
FRQGLWLRQ
 
6&/
 
6’$
 
ꢂ
ꢁ
ꢀ
ꢈ
ꢃ
ꢍ
$&.
 
06%
 
6WDUWꢄ
 
FRQGLWLRQ
 
ꢂ
ꢁ
ꢀ
ꢈ
ꢃ
ꢍ
6&/
 
6’$
 
06%
 
$&.
 
6WRS
 
FRQGLWLRQ
 
-3ꢄꢅꢍꢃꢌ6ꢃ  
Table 80. Device select code  
Device type identifier

(1)  

Chip Enable address  
RW  
b7  
b6  
b5  
b4  
b3  
b2  
b1  
b0  
1
0
1
0
1
1
0
RW  
1. The
 
most significant bit, b7, is sent first.  
74/88  
DS9985 Rev 12  
 
 
 

M24SR02-Y  
GPO parameters  
12  
GPO parameters  
This section lists the timing of the GPO according to its configuration.  
(1)  
Table 81. GPO timings measurement  
GPO field  
I/F  
Condition  
Command  
Symbol  
CmdSTPtoGPlow  
Typ. Unit  
Kill session  
Get session  
15

(2)  

GPO low when  
session active  
I

2

C  
µs  
ns  
0xX1  
0x1X  
I

2

C token release  
sequence  
I

2

C  
RF  
GPO return HZ  
AnswerlbLBtoGPHZ 105  
Session open  
GPO low when  
session active  
NDEF select  
Deselect  
CmdEOFtoGPlow  
170  
µs  
RF  
I

2

C  
GPO return HZ  
CmdEOFtoGPHZ  
CmdSTPtoGPlow  
370  
45  
µs  
ms  
µs  
GPO low when  
programming  
Update Binary  
Update Binary  
Writing time duration  
(No time extension)  
0xX2  
0x2X  
I

2

C  
RF  
RF  
5
75  
5
WIP  
CmdEOFtoGPlow  
GPO low when  
programming  
Writing time duration  
(No time extension)  
ms  
µs  
GPO low when a  
command is  
computed  
ReadBinary  
or  
UpdateBinary  
55  
or  
5
I

2

C  
CmdSTPtoGPlow  
ms  
ns  
Answer ready  
0xX3  
0x3X  
GPO return HZ on  
new command  
After NewCmdlbFB  
or AnswerlbFB  
I

2

C  
RF  
RF  
All commands  
105  
75  
5
GPO low when  
modifying NDEF  
UpdateBinary  
(Msg Length #0)  
CmdEOFtoGPlow  
µs  
Message in  
progress  
GPO low when  
modifying NDEF  
Writing time duration  
(No time extension)  
UpdateBinary  
SendInterrupt  
All commands  
SendInterrupt  
ms  
GPO low after  
receiving an  
Interrupt command  
I

2

C  
I

2

C  
CmdSTPtoGPlow  
50  
µs  
ns  
µs  
0xX4  
0x4X  
After NewCmdlbFB  
or AnswerlbFB  
Interrupt  
GPO return HZ  
105  
RF  
RF  
GPO low after  
receiving an  
Interrupt command  
CmdEOFtoGPlow  
Pulse duration  
75  
540  
DS9985 Rev 12  
75/88  
78  
 
 
 

GPO parameters  
GPO field  
M24SR02-Y  
(1)  
Table 81. GPO timings measurement  
(continued)  
Symbol  
I/F  
Condition  
Command  
Typ. Unit  
GPO low when  
reset  
I

2

C  
Reset GPO  
CmdSTPtoGPlow  
CmdSTPtoGPHZ  
CmdEOFtoGPlow  
CmdEOFtoGPHZ  
40  
0xX5  
0x5X  
GPO return HZ  
when set  
I

2

C  
RF  
RF  
Set GPO  
Reset GPO  
Set GPO  
40  
60  
State control  
GPO low when  
reset  
GPO return HZ  
when set  
60  
µs  
6
Anticollision  
command or start  
of RF disturb  
(command using  
another RF  
GPO low after  
receiving an RF  
command  
RF  
RF  
CmdSOFtoGPlow  
CmdEOFtoGPHZ  
protocol)  
RF busy  
0x6X  
Deselect or end of  
RF disturb  
(command using  
another RF  
GPO return HZ  
after deselection or  
RF command in  
another protocol  
460  
protocol)  
1. Characterized
 
only.  
2. Add
 
100 µs for boot after POR.  
76/88  
DS9985 Rev 12  

M24SR02-Y  
Write cycle definition  
13  
Write cycle definition  
(1)  
Table 82. Write cycle definition  
Test Conditions  
Symbol  
Parameter  
Min  
Max  
Units  
T

A

≤
25 °C, V

CC(min)

< V

CC

< V

CC(max)  

T

A

≤
85 °C, V

CC(min)

< V

CC

< V

CC(max)  

–
–
1,000,000  
600,000  
Write cycle  
Ncycle  
Write cycle  
endurance

(2)  

1. A
 
write cycle is calculated per byte, and corresponds to a write to this byte.  
2. Write
 
cycle endurance is defined by characterization and qualification.  
DS9985 Rev 12  
77/88  
78  
 
 
 
 

RF electrical parameters  
M24SR02-Y  
14  
RF electrical parameters  
This section summarizes the operating and measurement conditions, and the DC and AC  
characteristics of the device in RF mode.  
The parameters in the following tables are derived from tests performed under the  
measurement conditions summarized in the relevant tables. Designers have to check that  
the operating conditions in their circuit match the measurement conditions when relying on  
the quoted parameters.  
Table 83. Default operating conditions  
Symbol  
Parameter  
Min.  
Max.  
Unit  
T

A  

Ambient operating temperature  
–40  
85  
°C  
(1)  
Table 84. RF characteristics  
Symbol  
Parameter  
Condition  
Min  
Typ  
Max  
Unit  
f

C  

External RF signal frequency  
13.553  
1500  
13.560 13.567
 
MHz  
H_ISO  
Operating field according to ISO  
T

A

= 0 °C to 50 °C  
–
–
7500 mA/m  
7500 mA/m  
Operating field in extended  
temperature range  
H_Extended  
T

A

= -40 °C to 85 °C  
500  
MI

CARRIER

100% carrier modulation index  
MI=(A-B)/(A+B)  
90  
28 / f

C  

7 / f

C  

1.5 x t

4  

0
–
–
–
–
–
100  
40.5 / f

C  

t

1  

%
t

1  

t

2  

t

3  

t

4  

Pause A length  
–
–
–
–
Pause A low time  
Pause A rise time  
Pause A rise time section  
µs  
16 / f

C  

6 / f

C  

Minimum time from carrier  
generation to first data  
t

MIN CD  

W

t  

From H-field min  
–
–
–
–
5
–
ms  
RF write time (including internal  
verify) for one page  
6
C

TUN  

Internal tuning capacitor in SO8

(2)  

f

C

= 13.56 MHz  
Chip reset  
22.5  
–
25  
–
27.5  
5
pF  
t

RF_OFF  

RF OFF time  
ms  
1. All
 
timing characterizations are performed on a reference antenna with the following characteristics:  
External size: 75 mm x 48 mm  
Number of turns: 6  
Width of conductor: 0.6 mm  
Space between two conductors: 0.6 mm  
Value of the tuning capacitor in SO8: 25 pF (M24SR02-Y)  
Value of the coil: 5 µH  
Tuning frequency: 14.2 MHz.  
2. Characterized
 
only, at room temperature only, measured at VAC0-VAC1 = 2 V peak to peak at 13.56 MHz.  
78/88  
DS9985 Rev 12  
 
 
 
 

M24SR02-Y  
Package information  
15  
Package information  
In order to meet environmental requirements, ST offers these devices in different grades of  
ECOPACK packages, depending on their level of environmental compliance. ECOPACK  
specifications, grade definitions and product status are available at:

.  
ECOPACK is an ST trademark.  
15.1  
SO8N package information  
Figure 20. SO8N – 8-lead plastic small outline, 150 mils body width, package outline  
H X
ꢂ
ꢃƒ  
!ꢄ  
!
C
CCC  
B
E
ꢀꢁꢂꢃꢄPP  
*$8*(ꢄ3/$1(  
$
K
ꢁ
%ꢀ  
%
,
ꢀ
!ꢀ  
,ꢀ  
62ꢋ$B9ꢁ
 
1. Drawing
 
is not to scale.  
Table 85. SO8N – 8-lead plastic small outline, 150 mils body width,  
package data  
millimeters  
Typ  
inches

(1)  

Symbol  
Min  
Max  
Min  
Typ  
Max  
A
A1  
A2  
b
–
–
1.750  
0.250  
–
–
0.0689  
0.0098  
–
0.100  
1.250  
0.280  
0.170  
4.800  
5.800  
3.800  
–
–
0.0039  
0.0492  
0.0110  
0.0067  
0.1890  
0.2283  
0.1496  
–
–
–
–
–
0.480  
0.230  
5.000  
6.200  
4.000  
–
–
0.0189  
0.0091  
0.1969  
0.2441  
0.1575  
–
c
–
4.900  
6.000  
3.900  
1.270  
–
–
D
E
0.1929  
0.2362  
E1  
e
0.1535  
0.0500  
h
0.250  
0°  
0.500  
8°  
0.0098  
0°  
–
–
–
0.0197  
8°  
k
–
L
0.400  
–
1.270  
0.0157  
0.0500  
DS9985 Rev 12  
79/88  
84  
 
 
 
 
 
 

Package information  
M24SR02-Y  
Table 85. SO8N – 8-lead plastic small outline, 150 mils body width,  
package data (continued)  
millimeters  
inches

(1)  

Symbol  
Min  
Typ  
Max  
Min  
Typ  
Max  
L1  
–
–
1.040  
–
–
–
–
0.0409  
–
–
ccc  
0.100  
0.0039  
1. Values
 
in inches are converted from mm and rounded to four decimal digits.  
Figure 21. SO8N – 8-lead plastic small outline, 150 mils body width,  
package recommended footprint  
ꢊꢇꢌꢄꢎ[ꢃꢏ
 
ꢂꢇꢁꢈ
 
2ꢈB62ꢃ1B)3B9ꢂ
 
80/88  
DS9985 Rev 12  
 

M24SR02-Y  
Package information  
15.2  
TSSOP8 package information  
Figure 22. TSSOP8 – 8-lead thin shrink small outline, 3 x 6.4 mm, 0.65 mm pitch,  
package outline  
ꢀ
ϴ
ϱ
Đ
ꢄϭ  
ꢄ
ϭ
ϰ
ɲ
>
ꢃϭ  
ꢃϮ  
ꢃ
>ϭ  
ꢂW  
ď
Ğ
76623ꢃ$0B9ꢁ
 
1. Drawing
 
is not to scale.  
/
Table 86. TSSOP8 – 8-lead thin shrink small outline, 3 x 6.4 mm, 0.65 mm pitch,  
package mechanical data  
millimeters  
Min  
inches

(1)  

Symbol  
Typ  
Max  
Typ  
Min  
Max  
A
A1  
A2  
b
–
–
1.200  
0.150  
1.050  
0.300  
0.200  
0.100  
3.100  
–
–
–
0.0472  
0.0059  
0.0413  
0.0118  
0.0079  
0.0039  
0.1220  
–
0.050  
0.800  
0.190  
0.090  
–
–
0.0020  
0.0315  
0.0075  
0.0035  
–
–
0.0394  
–
1.000  
–
c
–
–
CP  
D
–
–
2.900  
–
3.000  
0.650  
6.400  
4.400  
0.600  
1.000  
0.1142  
–
0.1181  
0.0256  
0.2520  
0.1732  
0.02636  
0.0394  
–
e
E
6.200  
4.300  
0.450  
–
6.600  
4.500  
0.750  
–
0.2441  
0.1693  
0.0177  
–
0.2598  
0.1772  
0.0295  
–
E1  
L
L1  
α
0°  
8°  
0°  
8°  
1. Values
 
in inches are converted from mm and rounded to four decimal digits.  
DS9985 Rev 12  
81/88  
84  
 
 
 
 
 

Package information  
M24SR02-Y  
15.3  
UFDFPN8 package information  
Figure 23. UFDFPN8 – 8-lead, 2 x 3 mm, 0.5 mm pitch ultra thin profile fine pitch  
dual flat package outline  
$
‘
%
1
$
$ꢂ
 
FFF
 
ꢂ
3LQꢄꢐꢂꢄ
 
,’ꢄPDUNLQJ
 
&
(
HHH
 
&
 
6HDWLQJꢄSODQH
 
$ꢀ
 
6LGHꢄYLHZ
 
DDD
 
&
ꢁ[
 
ꢂ
ꢁ
ꢁ[
 
DDD
 
&
 
7
R
SꢄYLHZ
 
‘ꢁ
 
H
‘DWXPꢄ$
 
E
ꢂ
ꢁ
/ꢂ
 
/ꢀ
 
3LQꢄꢐꢂꢄ
 
/
/ꢀ
 
(ꢁ
 
.
,’ꢄPDUNLQJ
 
Hꢅꢁ
 
/ꢂ
 
7
H
UPLQDOꢄWLS
 
H
‘HWDLOꢄ³$´
 
/
(YHQꢄWHUPLQDO
 
1’ꢋꢂꢄ
[
H
 
%RWWRPꢄYLHZ
 
6HHꢄ’HWDLOꢄ³$´
 
=:EB0(B9ꢂ
 
1. Max
 
package warpage is 0.05 mm.  
2. Exposed
 
copper is not systematic and can appear partially or totally according to the cross section.  
3. Drawing
 
is not to scale.  
4. The
 
central pad (the area E2 by D2 in the above illustration) must be either connected to V

SS

or left floating  
(not connected) in the end application.  
82/88  
DS9985 Rev 12  
 
 
 
 

M24SR02-Y  
Package information  
Table 87. UFDFPN8 – 8- lead, 2 x 3 mm, 0.5 mm pitch ultra thin profile fine pitch  
dual flat package mechanical data  
millimeters  
Typ  
inches

(1)  

Symbol  
Min  
Max  
Min  
Typ  
Max  
A
0.450  
0.550  
0.600  
0.050  
0.300  
2.100  
1.600  
3.100  
1.600  
–
0.0177  
0.0217  
0.0236  
0.0020  
0.0118  
0.0827  
0.0630  
0.1220  
0.0630  
–
A1  
0.000  
0.020  
0.0000  
0.0008  
b

(2)  

0.200  
0.250  
0.0079  
0.0098  
D
1.900  
2.000  
0.0748  
0.0787  
D2 (rev MC)  
1.200  
–
0.0472  
–
E
2.900  
3.000  
0.1142  
0.1181  
E2 (rev MC)  
1.200  
–
0.0472  
–
e
K (rev MC)  
L
–
0.500  
–
0.0197  
0.300  
–
–
–
–
–
–
–
–
–
–
0.0118  
–
–
–
–
–
–
–
–
–
–
0.300  
0.500  
0.150  
–
0.0118  
0.0197  
0.0059  
–
L1  
–
–
L3  
0.300  
0.0118  
aaa  
–
–
–
–
–
0.150  
0.100  
0.100  
0.050  
0.080  
–
–
–
–
–
0.0059  
0.0039  
0.0039  
0.0020  
0.0031  
bbb  
ccc  
ddd  
eee

(3)  

1. Values
 
in inches are converted from mm and rounded to four decimal digits.  
2. Dimension
 
b applies to plated terminal and is measured between 0.15 and 0.30 mm from the terminal tip.  
3. Applied
 
for exposed die paddle and terminals. Exclude embedded part of exposed die paddle from  
measuring.  
DS9985 Rev 12  
83/88  
84  
 

Ordering information  
M24SR02-Y  
16  
Ordering information  
Example:  
M24 SR  
02- Y
 
MN  
6
T
/2  
Device type  
M24 = I

2

C interface device  
Device feature  
SR = Short range  
Memory size  
02 = memory size in Kbits  
Voltage range  
Y = 2.7 to 5.5 V  
Package  
MN = SO8N  
DW = TSSOP8  
MC = UFDFPN8  
SG12I = 120 µm ± 15 µm bumped and sawn inkless wafer on 8-inch frame  
U = unsawn wafer 725 µm ± 20 µm  
Device grade  
6 = industrial: device tested with standard test flow over –40 to 85 °C  
(no parameter for SG12I)  
Option  
T =
T
a
pe and reel packing  
(no parameter for SG12I)  
Capacitance  
/2 = 25 pF  
Note:  
Parts marked as “ES”, “E” or accompanied by an Engineering Sample notification letter, are  
not yet qualified and therefore not approved for use in production. ST is not responsible for  
any consequences resulting from such use. In no event will ST be liable for the customer  
using any of these engineering samples in production. ST Quality has to be contacted prior  
to any decision to use these Engineering samples to run qualification activity.  
84/88  
DS9985 Rev 12  
 
 

M24SR02-Y  
Revision history  
17  
Revision history  
Table 88. Document revision history  
Changes  
Date  
Revision  
29-Oct-2013  
1
Initial release.  
09-Nov-2013  
2
Changed the datasheet status from “Preliminary data” to “Production  
data”.  
Restored the whole content of

.  
Updated the capacitor values in

VCC

.  
Updated V

ESD

value in

, I

CC  

20-Dec-2013  
3
Added details to “S(WTX)” bullet in

.  
Added sentences to

and to  
Changed ‘0x001E’ value into ‘0x001F’ in

Updated values in

.  

file

.  
Added I

2

C text to the Note below

.  
Edited the third paragraph of

Updated bullet 3 in

, and the Payload row  
28-Feb-2014  
4
Edited V

IO

row and removed V

ESD

(machine model) row from

Updated I

CC

rows and added a Note to

.  
changed into UFDFPN8.  
DS9985 Rev 12  
85/88  
87  
 
 

Revision history  
M24SR02-Y  
Table 88. Document revision history (continued)  
Revision Changes  
Date  
Added data for automotive grade in

and

Added WFDFPN8 package for automotive grade under qualification  
Added
Figure 24: WFDFPN8 (MLP8) 8-lead, 2 x 3 mm, 0.5 mm pitch  
very thin fine pitch dual flat package outline  
04-Jun-2014  
5
Added
T
a
ble 88: WFDFPN8 8-lead thin fine pitch dual flat package no  
lead mechanical data  
Added MF = WFDFPN8 inside
Table 88: Ordering information scheme  
for packaged devices  
Inserted byte <04> between A4 and 00 inside

Added  
Updated:  
04-May-2016  
6
Updated:  
08-Aug-2016  
7
Updated:  
04-Oct-2016  
23-Nov-2016  
8
9
Updated:  
86/88  
DS9985 Rev 12  

M24SR02-Y  
IMPORTANT NOTICE – PLEASE READ CAREFULLY  
STMicroelectronics NV and its subsidiaries (“ST”) reserve the right to make changes, corrections, enhancements, modifications, and  
improvements to ST products and/or to this document at any time without notice. Purchasers should obtain the latest relevant information on  
ST products before placing orders. ST products are sold pursuant to ST’s terms and conditions of sale in place at the time of order  
acknowledgement.  
Purchasers are solely responsible for the choice, selection, and use of ST products and ST assumes no liability for application assistance or  
the design of Purchasers’ products.  
No license, express or implied, to any intellectual property right is granted by ST herein.  
Resale of ST products with provisions different from the information set forth herein shall void any warranty granted by ST for such product.  
ST and the ST logo are trademarks of S
T
.
F
or additional information about ST trademarks, please refer to

.
All other  
product or service names are the property of their respective owners.  
Information in this document supersedes and replaces information previously supplied in any prior versions of this document.  
© 2019 STMicroelectronics – All rights reserved  
88/88  
DS9985 Rev 12