TDK-B84142A0050R000
| Part # | TDK-B84142A0050R000 |
| Download | TDK-B84142A0050R000 |
EMC filters
2-line filters
for converters and power electronics
Series/Type:
B84142A*R000/G075
The following products presented in this data sheet are being withdrawn.
Ordering Code
Substitute Product
Date of
Withdrawal
Deadline Last
Last
Orders
Shipments
B84142A0060G075
B84142A0060
R
000
2019-06-21
2019-09-30
2019-12-31
Please contact your nearest TDK sales office if you need support in selecting a suitable
electronics.tdk.com/sales.
2-line filters
B84142A*R000/G075
for converters and power electronics
Power line filters for 1-phase systems
Rated voltage V
R
: 250 V AC/DC
Rated current I
R
: 10 A to 60 A
Construction
2-line filters
Metal case
Features
High insertion loss
Easy to install
Degree of protection IP 20
1)
for *R000
Very compact design
Optimized for long motor cables
and operation under full load
ENEC, UL and cUL approval for B84142A*R000
Typical applications
Frequency converters for motor drives, e.g.
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
elevators
conveyor systems
pumps
traction systems
HVAC systems (heating, ventilation and air
conditioning)
Power supplies
DC applications
Terminals
Finger-safe terminal blocks
Threaded studs
Marking
Marking on component:
Manufacturer’s logo, ordering code, rated voltage, rated
current, rated temperature, climatic category, date code,
approvals
Minimum data on packaging:
Manufacturer’s logo, ordering code, quantity, date code
1) According
to IEC 60529
Please read
C
autions and warnings
a
nd
I
m
po
r
tant notes
a
t the end of this document.
Page 2 of 13
2-line filters
B84142A*R000/G075
for converters and power electronics
Typical circuit diagram
Technical data and measuring conditions
Rated voltage V
R
Rated current I
R
Test voltage V
test
250 V AC (50/60 Hz) / 250 V DC
Referred to 40
°
C rated temperature
1770 V DC, 2 s (line/line)
2700 V DC, 2 s (lines/case)
Overload capability (thermal)
1.5
ꢁ
I
R
for 3 min per hour or
2.5
ꢁ
I
R
for 30 s per hour
Leakage current l
LK
At V
R
and 50 Hz
Climatic category (IEC 60068-1)
R000: 25/100/21 (
ꢀ
25
°
C/+100
°
C/21 days damp heat test)
G075: 25/085/21 (
ꢀ
25
°
C/+85
°
C/21 days damp heat test)
Approvals
IEC 60939, UL 1283, CSA C22.2 No.8
Characteristics and ordering codes
Screw
stud
Approvals
I
R
Terminal
cross section
mm
2
I
LK
R
typ
Approx. Ordering
code
weight
kg
A
mA
m
Ω
V
R
= 250 V AC/DC
10
20
30
40
50
60
60
4
4
6
6
16
16
7.9 18
7.9 10
0.55
1.0
1.0
1.0
2.5
B84142A0010R000
×
×
×
×
×
×
ꢀ
×
×
×
×
×
×
×
×
×
×
B84142A0020R000
B84142A0030R000
B84142A0040R000
B84142A0050R000
B84142A0060R000
B84142A0060G075
7.9
17
26
26
26
5
3.6
2.6
2.45 2.5
1.4 2.5
M6
ꢀ
ꢀ
×
= Approval granted
Please read
C
autions and warnings
a
nd
I
m
po
r
tant notes
a
t the end of this document.
Page 3 of 13
2-line filters
B84142A*R000/G075
for converters and power electronics
Dimensional drawings
B84142A0010R000 (10 A)
General tolerances according to ISO 2768
ꢀ
cL
Dimensions in mm
B84142A0020R000 (20 A)
General tolerances according to ISO 2768
ꢀ
cL
Dimensions in mm
Please read
C
autions and warnings
a
nd
I
m
po
r
tant notes
a
t the end of this document.
Page 4 of 13
2-line filters
B84142A*R000/G075
for converters and power electronics
B84142A0030R000, B84142A0040R000 (30 A and 40 A)
General tolerances according to ISO 2768
ꢀ
cL
Dimensions in mm
B84142A0050R000, B84142A0060R000 (50 A and 60 A)
General tolerances according to ISO 2768
ꢀ
cL
Dimensions in mm
Please read
C
autions and warnings
a
nd
I
m
po
r
tant notes
a
t the end of this document.
Page 5 of 13
2-line filters
B84142A*R000/G075
for converters and power electronics
B84142A0060G075 (60 A)
General tolerances according to ISO 2768
ꢀ
cL
Dimensions in mm
Please read
C
autions and warnings
a
nd
I
m
po
r
tant notes
a
t the end of this document.
Page 6 of 13
2-line filters
B84142A*R000/G075
for converters and power electronics
Insertion loss
(typical values at Z = 50
Ω
)
Filters for 10 A
Filters for 20 A
Filters for 30 A
Filters for 40 A
Please read
C
autions and warnings
a
nd
I
m
po
r
tant notes
a
t the end of this document.
Page 7 of 13
2-line filters
B84142A*R000/G075
for converters and power electronics
Insertion loss
(typical values at Z = 50
Ω
)
Filters for 50 A
Filters for 60 A
Please read
C
autions and warnings
a
nd
I
m
po
r
tant notes
a
t the end of this document.
Page 8 of 13
2-line filters
B84142A*R000/G075
for converters and power electronics
Cautions and warnings
Please read all safety and warning notes carefully before installing the EMC filter and putting it
into operation (see
). The same applies to the warning signs on the filter. Please ensure that
the signs are not removed nor their legibility impaired by external influences.
Death, serious bodily injury and substantial material damage to equipment may occur if the
appropriate safety measures are not carried out or the warnings in the text are not observed.
Using according to the terms
The EMC filters may be used only for their intended application within the specified values in low-
voltage networks in compliance with the instructions given in the data sheets and the data book.
The conditions at the place of application must comply with all specifications for the filter used.
Warning
It shall be ensured that only qualified persons (electricity specialists) are engaged on work such
as planning, assembly, installation, operation, repair and maintenance. They must be provided
with the corresponding documentation.
Danger of electric shock. EMC filters contain components that store an electric charge. Danger-
ous voltages can continue to exist at the filter terminals for longer than five minutes even after
the power has been switched off.
The protective earth connections shall be the first to be made when the EMC filter is installed
and the last to be disconnected. Depending on the magnitude of the leakage currents, the par-
ticular specifications for making the protective-earth connection must be observed.
Impermissible overloading of the EMC filter or filter, such as with circuits able to cause reso-
nances, impermissible voltages at higher frequencies etc. can lead to bodily injury and death as
well as cause substantial material damages (e.g. destruction of the filter housing).
EMC filters and filters must be protected in the application against impermissible exceeding of
the rated currents by overcurrent protective circuitry.
In case of leakage currents >3.5 mA you shall mount the PE conductor stationary with the
required cross section before beginning of operation and save it against disconnecting. For
leakage currents I
L
1)
<10 mA the PE conductor must have a KU value
2)
of 4.5 A
3)
; for leakage
currents I
L
≥
10 mA the PE conductor must have a KU value of 6.
4)
Output chokes and output filters must be protected in the application against impermissible
exceeding of the component temperature.
The converter output frequency must be within the specified range to avoid resonances and
uncontrolled warming of the output chokes and output filters.
1) I
L
= leakage current let-go
2) The
KU value (symbol KU) is a classification parameter of safety-referred failure types designed to ensure protection against hazardous
body currents and excessive heating.
3) A
value of KU = 4.5 with respect to interruptions is attained with: a) a permanently connected protective earth circuit
≥
2.5 mm
2
connected via shroud connectors (IEC 60309
ꢀ
2) and b) a protective earth circuit.
4) KU
= 6 with respect to interruptions is achieved for fixed
ꢀ
connection lines
≥
10 mm
2
where the type of connection and line layout
correspond to the requirements for PEN conductors as specified in relevant standards.
Please read
C
autions and warnings
a
nd
I
m
po
r
tant notes
a
t the end of this document.
Page 9 of 13
2-line filters
B84142A*R000/G075
for converters and power electronics
The table below summarizes the safety instructions that must be observed without fail. A detailed
description can be found in the relevant chapters of the databook.
Topic
Instructions
Reference chapter
(data book),
paragraph
Selecting a filter
When selecting a filter, it is mandatory to observe the
Selection guide for
rated data of the equipment (such as its rated input
current, rated voltage, harmonic content etc.) as well
as the derating instructions in Chapters 9 and 10.
converter filters
Rated voltage
When power distribution systems deviating from the
Power distribution
symmetric TN-S system it is to check the suitability of
systems,
the EMC filters and the allowed voltages including the
fault cases.
7
Protection from
residual voltages
Discharge resistors
Active parts must be discharged within 5 s to a Safety
regulations,
voltage of less than 60 V (or 50
µ
C). If this limit
6.1
cannot be observed due to the operating mode, the
hazardous point must be permanently marked in a
clearly visible way.
Filters which are not permanently connected (e.g.
when the test voltage is applied to the filter at the
incoming goods inspection) must be discharged after
the voltage has been switched off.
Safety regulations,
6.2
Installing and
removing of EMC
filters
When installing and removing our EMC filters, a Safety
regulations,
voltage-free state must be set up and secured with
6.4
observance of the five safety rules described in
EN 50110-1.
Installation
Use in IT systems
The special features of the IT system (“first fault case”
Power distribution
and other fault cases) shall be observed.
system (network
types), 7.6
Safety notes on
leakage currents
The filter leakage currents specified in the data book
Leakage current,
are intended for user information only.The maximum
8.4
leakage current of the entire electrical equipment or
Leakage current,
appliance has to be limited for safety reasons. Please
8.6
obtain the applicable limits for your application from
the relevant regulations, provisions and standards.
Voltage derating
If the permissible limits for the higher-frequency Voltage
derating,
voltages at the filter are exceeded, the filter may be
9.8
damaged or destroyed.
Hazards caused by
overloading the filters
Current derating at
elevated ambient
temperatures
Non-observance of the current derating may lead to
Current derating,
overheating and consequently represents
hazard.
a fire 10.1
Please read
C
autions and warnings
a
nd
I
m
po
r
tant notes
a
t the end of this document.
Page 10 of 13
2-line filters
B84142A*R000/G075
for converters and power electronics
Topic
Instructions
Reference chapter
(data book),
paragraph
Protective earth
connection at
operating currents
>250 A
For operating currents greater than 250 A, we Mounting
recommend the PE connection to be set up between
instructions, point
the feed (filter: line) and output (filter: load) not via the
PE terminal bolt in the filter housing.
2
Mounting position
Note the mounting position of the filters! It must Mounting
always be ensured that natural convection is not instructions,
point
impaired.
13
Long motor cables
Long motor cables cause parasitic currents in the
Mounting
installation. The cable lengths indicated for the output
instructions, point
chokes and output filters serve for orientation. The
user must check the technical parameters and
especially the choke temperatures for the respective
application.
15
Display of ordering codes for EPCOS products
The ordering code for one and the same product can be represented differently in data sheets,
data books, other publications and the website of EPCOS, or in order-related documents such as
shipping notes, order confirmations and product labels. The varying representations of the
ordering codes are due to different processes employed and do not affect the specifications of the
respective products. Detailed information can be found on the Internet under
Please read
C
autions and warnings
a
nd
I
m
po
r
tant notes
a
t the end of this document.
Page 11 of 13
2-line filters
B84142A*R000/G075
for converters and power electronics
Symbols and terms
Symbol
English
German
α
Insertion loss
Einfügungsdämpfung
Bemessungskapazität
Kapazität X-Kondensator
Kapazität Y-Kondensator
Spannungsabfall im Filter
Spannungsanstiegsgeschwindigkeit
Frequenz
C
R
C
X
C
Y
∆
V
dv/dt
f
Rated capacitance
Capacitance X capacitor
Capacitance Y capacitor
Voltage drop (input to output)
Rate of voltage rise
Frequency
f
M
f
P
Converter output frequency
Pulse frequency
Motorfrequenz
Pulsfrequenz
f
R
f
res
I
C
I
LK
I
max
I
N
Rated frequency
Bemessungsfrequenz
Resonanzfrequenz
Strom durch Kondensator
Filter-Ableitstrom
Maximalstrom
Nennstrom
Resonant frequency
Current through capacitor
Filter leakage current
Maximum current
Nominal current
I
op
I
pk
I
q
I
R
Operating current (design current)
Rated peak withstand current
Capacitive reactive current
Rated current
Betriebsstrom
Bemessungs-Stoßstromfestigkeit
Kapazitiver Blindstrom
Bemessungsstrom
I
S
L
Interference current
Inductance
Störstrom
Induktivität
L
R
L
stray
P
L
R
Rated inductance
Stray inductance
Power loss
Resistance
Bemessungsinduktivität
Streuinduktivität
Verlustleistung
Widerstand
R
is
R
typ
T
A
T
max
T
min
T
R
u
k
V
eff
V
K
V
LE
V
N
V
R
V
peak
V
test
V
X
V
Y
X
L
Z
Insulation resistance
DC resistance, typical value
Ambient temperature
Upper category temperature
Lower category temperature
Rated temperature
Refered voltage drop in %
RMS voltage
Isolationswiderstand
Gleichstromwiderstand, Richtwert
Umgebungstemperatur
Obere Kategorietemperatur
Untere Kategorietemperatur
Bemessungstemperatur
Bezogener Spannungsabfall in %
Effektivdivnung
Voltage drop
Spannungsabfall
Voltage line to earth; voltage line to ground
Spannung Phase zu Erdpotential
Nominal voltage
Rated voltage
Peak voltage
Nenndivnung
Bemessungsdivnung
Spitzendivnung
Test voltage
Prüfdivnung
Voltage over X capacitor
Voltage over Y capacitor
Inductive reactance
Impedance
Spannung über X-Kondensator
Spannung über Y-Kondensator
Induktiver Blindwiderstand
Scheinwidertand
|Z|
Impedance, absolute value
Scheinwiderstand (Betragswert)
Please read
C
autions and warnings
a
nd
I
m
po
r
tant notes
a
t the end of this document.
Page 12 of 13
Important notes
The following applies to all products named in this publication:
1.
Some parts of this publication contain
statements about the suitability of our products for certain
areas of application
. These statements are based on our knowledge of typical requirements that are
often placed on our products in the areas of application concerned. We nevertheless expressly point
out
that such statements cannot be regarded as binding statements about the suitability of our
products for a particular customer application.
As a rule we are either unfamiliar with individual
customer applications or less familiar with them than the customers themselves. For these reasons, it is
always ultimately incumbent on the customer to check and decide whether a product with the properties
described in the product specification is suitable for use in a particular customer application.
2.
We also point out that
in individual cases, a malfunction of electronic components or failure
before the end of their usual service life cannot be completely ruled out in the current state of the
art, even if they are operated as specified.
In customer applications requiring a very high level of
operational safety and especially in customer applications in which the malfunction or failure of an
electronic component could endanger human life or health (e.g. in accident prevention or life-saving
systems), it must therefore be ensured by means of suitable design of the customer application or other
action taken by the customer (e.g. installation of protective circuitry or redundancy) that no injury or
damage is sustained by third parties in the event of malfunction or failure of an electronic component.
3.
The warnings, cautions and product-specific notes must b
e
observed.
4.
In order to satisfy certain technical requirements,
some of the products described in this publication
may contain substances subject to restrictions in certain jurisdictions (e.g. because they are
classed as hazardous)
. Useful information on this will be found in our Material Data Sheets on the
Internet (www.tdk-electronics.tdk.com/material). Should you have any more detailed questions, please
contact our sales offices.
5.
We constantly strive to improve our products. Consequently,
the products described in this
publication may change from time to time
. The same is true of the corresponding product
specifications. Please check therefore to what extent product descriptions and specifications contained
in this publication are still applicable before or when you place an order.
We also
reserve the right to discontinue production and delivery of products
. Consequently, we
cannot guarantee that all products named in this publication will
always be available.
The
aforementioned does not apply in the case of individual agreements deviating from the foregoing for
customer-specific products.
6.
Unless otherwise agreed in individual contracts,
all orders are subject to our General Terms and
Conditions of Supply.
7.
Our manufacturing sites serving the automotive business apply the IATF 16949 standard.
The
IATF certifications confirm our compliance with requirements regarding the quality management system
in the automotive industry. Referring to customer requirements and customer specific requirements
(“CSR”) TDK always has and will continue to have the policy of respecting individual agreements. Even
if IATF 16949 may appear to support the acceptance of unilateral requirements, we hereby like to
emphasize that
only requirements mutually agreed upon can and will be implemented in our
Quality Management System.
For clarification purposes we like to point out that obligations from IATF
16949 shall only become legally binding if individually agreed upon.
8.
The trade names EPCOS, CeraCharge, CeraDiode, CeraLink, CeraPad, CeraPlas, CSMP, CTVS,
DeltaCap, DigiSiMic, ExoCore, FilterCap, FormFit, LeaXield, MiniBlue, MiniCell, MKD, MKK, MotorCap,
PCC, PhaseCap, PhaseCube, PhaseMod, PhiCap, PowerHap, PQSine, PQvar, SIFERRIT, SIFI,
SIKOREL, SilverCap, SIMDAD, SiMic, SIMID, SineFormer, SIOV, ThermoFuse, WindCap are
trademarks registered or pending
in Europe and in other countries. Further information will be found
Release 2018-10
Page 13 of 13