TDK-B84142A0050R000

Part #TDK-B84142A0050R000
Download 
TDK-B84142A0050R000
EMC filters  
2-line filters  
for converters and power electronics  
Series/Type:  
B84142A*R000/G075  
The following products presented in this data sheet are being withdrawn.  
Ordering Code  
Substitute Product  
Date of  
Withdrawal  
Deadline Last
 
Last  
Orders  
Shipments  
B84142A0060G075  
B84142A0060
R
000  
2019-06-21  
2019-09-30  
2019-12-31  
Please contact your nearest TDK sales office if you need support in selecting a suitable  
electronics.tdk.com/sales.  

2-line filters  
B84142A*R000/G075  
for converters and power electronics  
Power line filters for 1-phase systems  
Rated voltage V

R

: 250 V AC/DC  
Rated current I

R

: 10 A to 60 A  
Construction  
2-line filters  
Metal case  
Features  
High insertion loss  
Easy to install  
Degree of protection IP 20

1)

for *R000  
Very compact design  
Optimized for long motor cables  
and operation under full load  
ENEC, UL and cUL approval for B84142A*R000  
Typical applications  
Frequency converters for motor drives, e.g.  
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
elevators  
conveyor systems  
pumps  
traction systems  
HVAC systems (heating, ventilation and air  
conditioning)  
Power supplies  
DC applications  
Terminals  
Finger-safe terminal blocks  
Threaded studs  
Marking  
Marking on component:  
Manufacturer’s logo, ordering code, rated voltage, rated  
current, rated temperature, climatic category, date code,  
approvals  
Minimum data on packaging:  
Manufacturer’s logo, ordering code, quantity, date code  
1) According
 
to IEC 60529  
Please read
C
autions and warnings
a
nd  
I
m
po
r
tant notes
a
t the end of this document.  
Page 2 of 13  

2-line filters  
B84142A*R000/G075  
for converters and power electronics  
Typical circuit diagram  
Technical data and measuring conditions  
Rated voltage V

R  

Rated current I

R  

Test voltage V

test  

250 V AC (50/60 Hz) / 250 V DC  
Referred to 40
°
C rated temperature  
1770 V DC, 2 s (line/line)  
2700 V DC, 2 s (lines/case)  
Overload capability (thermal)  
1.5
ꢁ
I

R

for 3 min per hour or  
2.5
ꢁ
I

R

for 30 s per hour  
Leakage current l

LK  

At V

R

and 50 Hz  
Climatic category (IEC 60068-1)  
R000: 25/100/21 (
ꢀ
25
°
C/+100
°
C/21 days damp heat test)  
G075: 25/085/21 (
ꢀ
25
°
C/+85
°
C/21 days damp heat test)  
Approvals  
IEC 60939, UL 1283, CSA C22.2 No.8  
Characteristics and ordering codes  
Screw  
stud  
Approvals  
I

R  

Terminal  
cross section  
mm

2  

I

LK  

R

typ  

Approx. Ordering
 
code  
weight  
kg  
A
mA  
m
Ω  
V

R

= 250 V AC/DC  
10  
20  
30  
40  
50  
60  
60  
4
4
6
6
16  
16  
7.9 18  
7.9 10  
0.55  
1.0  
1.0  
1.0  
2.5  
B84142A0010R000  
×
×
×
×
×
×
ꢀ
×
×
×
×
×
×
×
×
×
×
B84142A0020R000  
B84142A0030R000  
B84142A0040R000  
B84142A0050R000  
B84142A0060R000  
B84142A0060G075  
7.9  
17  
26  
26  
26  
5
3.6  
2.6  
2.45 2.5  
1.4 2.5  
M6  
ꢀ
ꢀ
×
= Approval granted  
Please read
C
autions and warnings
a
nd  
I
m
po
r
tant notes
a
t the end of this document.  
Page 3 of 13  

2-line filters  
B84142A*R000/G075  
for converters and power electronics  
Dimensional drawings  
B84142A0010R000 (10 A)  
General tolerances according to ISO 2768
ꢀ
cL  
Dimensions in mm  
B84142A0020R000 (20 A)  
General tolerances according to ISO 2768
ꢀ
cL  
Dimensions in mm  
Please read
C
autions and warnings
a
nd  
I
m
po
r
tant notes
a
t the end of this document.  
Page 4 of 13  

2-line filters  
B84142A*R000/G075  
for converters and power electronics  
B84142A0030R000, B84142A0040R000 (30 A and 40 A)  
General tolerances according to ISO 2768
ꢀ
cL  
Dimensions in mm  
B84142A0050R000, B84142A0060R000 (50 A and 60 A)  
General tolerances according to ISO 2768
ꢀ
cL  
Dimensions in mm  
Please read
C
autions and warnings
a
nd  
I
m
po
r
tant notes
a
t the end of this document.  
Page 5 of 13  

2-line filters  
B84142A*R000/G075  
for converters and power electronics  
B84142A0060G075 (60 A)  
General tolerances according to ISO 2768
ꢀ
cL  
Dimensions in mm  
Please read
C
autions and warnings
a
nd  
I
m
po
r
tant notes
a
t the end of this document.  
Page 6 of 13  

2-line filters  
B84142A*R000/G075  
for converters and power electronics  
Insertion loss
(typical values at Z = 50
Ω
)  
Filters for 10 A  
Filters for 20 A  
Filters for 30 A  
Filters for 40 A  
Please read
C
autions and warnings
a
nd  
I
m
po
r
tant notes
a
t the end of this document.  
Page 7 of 13  

2-line filters  
B84142A*R000/G075  
for converters and power electronics  
Insertion loss
(typical values at Z = 50
Ω
)  
Filters for 50 A  
Filters for 60 A  
Please read
C
autions and warnings
a
nd  
I
m
po
r
tant notes
a
t the end of this document.  
Page 8 of 13  

2-line filters  
B84142A*R000/G075  
for converters and power electronics  
Cautions and warnings  
Please read all safety and warning notes carefully before installing the EMC filter and putting it  
into operation (see
 
). The same applies to the warning signs on the filter. Please ensure that  
the signs are not removed nor their legibility impaired by external influences.  
Death, serious bodily injury and substantial material damage to equipment may occur if the  
appropriate safety measures are not carried out or the warnings in the text are not observed.  
Using according to the terms  
The EMC filters may be used only for their intended application within the specified values in low-  
voltage networks in compliance with the instructions given in the data sheets and the data book.  
The conditions at the place of application must comply with all specifications for the filter used.  
Warning  
It shall be ensured that only qualified persons (electricity specialists) are engaged on work such  
as planning, assembly, installation, operation, repair and maintenance. They must be provided  
with the corresponding documentation.  
Danger of electric shock. EMC filters contain components that store an electric charge. Danger-  
ous voltages can continue to exist at the filter terminals for longer than five minutes even after  
the power has been switched off.  
The protective earth connections shall be the first to be made when the EMC filter is installed  
and the last to be disconnected. Depending on the magnitude of the leakage currents, the par-  
ticular specifications for making the protective-earth connection must be observed.  
Impermissible overloading of the EMC filter or filter, such as with circuits able to cause reso-  
nances, impermissible voltages at higher frequencies etc. can lead to bodily injury and death as  
well as cause substantial material damages (e.g. destruction of the filter housing).  
EMC filters and filters must be protected in the application against impermissible exceeding of  
the rated currents by overcurrent protective circuitry.  
In case of leakage currents >3.5 mA you shall mount the PE conductor stationary with the  
required cross section before beginning of operation and save it against disconnecting. For  
leakage currents I

L

1)

<10 mA the PE conductor must have a KU value

2)

of 4.5 A

3)

; for leakage  
currents I

L

≥
10 mA the PE conductor must have a KU value of 6.

4)  

Output chokes and output filters must be protected in the application against impermissible  
exceeding of the component temperature.  
The converter output frequency must be within the specified range to avoid resonances and  
uncontrolled warming of the output chokes and output filters.  
1) I

L

= leakage current let-go  
2) The
 
KU value (symbol KU) is a classification parameter of safety-referred failure types designed to ensure protection against hazardous  
body currents and excessive heating.  
3) A
 
value of KU = 4.5 with respect to interruptions is attained with: a) a permanently connected protective earth circuit
≥
2.5 mm

2  

connected via shroud connectors (IEC 60309
ꢀ
2) and b) a protective earth circuit.  
4) KU
 
= 6 with respect to interruptions is achieved for fixed
ꢀ
connection lines
≥
10 mm

2

where the type of connection and line layout  
correspond to the requirements for PEN conductors as specified in relevant standards.  
Please read
C
autions and warnings
a
nd  
I
m
po
r
tant notes
a
t the end of this document.  
Page 9 of 13  

2-line filters  
B84142A*R000/G075  
for converters and power electronics  
The table below summarizes the safety instructions that must be observed without fail. A detailed  
description can be found in the relevant chapters of the databook.  
Topic  
Instructions  
Reference chapter  
(data book),  
paragraph  
Selecting a filter  
When selecting a filter, it is mandatory to observe the
 
Selection guide for  
rated data of the equipment (such as its rated input  
current, rated voltage, harmonic content etc.) as well  
as the derating instructions in Chapters 9 and 10.  
converter filters  
Rated voltage  
When power distribution systems deviating from the  
Power distribution  
symmetric TN-S system it is to check the suitability of
 
systems,  
the EMC filters and the allowed voltages including the  
fault cases.  
7
Protection from  
residual voltages  
Discharge resistors  
Active parts must be discharged within 5 s to a Safety
 
regulations,  
voltage of less than 60 V (or 50
µ
C). If this limit
 
6.1  
cannot be observed due to the operating mode, the  
hazardous point must be permanently marked in a  
clearly visible way.  
Filters which are not permanently connected (e.g.  
when the test voltage is applied to the filter at the  
incoming goods inspection) must be discharged after  
the voltage has been switched off.  
Safety regulations,  
6.2  
Installing and  
removing of EMC  
filters  
When installing and removing our EMC filters, a Safety
 
regulations,  
voltage-free state must be set up and secured with
 
6.4  
observance of the five safety rules described in  
EN 50110-1.  
Installation  
Use in IT systems  
The special features of the IT system (“first fault case”
 
Power distribution  
and other fault cases) shall be observed.  
system (network  
types), 7.6  
Safety notes on  
leakage currents  
The filter leakage currents specified in the data book
 
Leakage current,  
are intended for user information only.The maximum
 
8.4  
leakage current of the entire electrical equipment or
 
Leakage current,  
appliance has to be limited for safety reasons. Please
 
8.6  
obtain the applicable limits for your application from  
the relevant regulations, provisions and standards.  
Voltage derating  
If the permissible limits for the higher-frequency Voltage
 
derating,  
voltages at the filter are exceeded, the filter may be
 
9.8  
damaged or destroyed.  
Hazards caused by  
overloading the filters  
Current derating at  
elevated ambient  
temperatures  
Non-observance of the current derating may lead to
 
Current derating,  
overheating and consequently represents  
hazard.  
a fire 10.1  
Please read
C
autions and warnings
a
nd  
I
m
po
r
tant notes
a
t the end of this document.  
Page 10 of 13  

2-line filters  
B84142A*R000/G075  
for converters and power electronics  
Topic  
Instructions  
Reference chapter  
(data book),  
paragraph  
Protective earth  
connection at  
operating currents  
>250 A  
For operating currents greater than 250 A, we Mounting  
recommend the PE connection to be set up between
 
instructions, point  
the feed (filter: line) and output (filter: load) not via the  
PE terminal bolt in the filter housing.  
2
Mounting position  
Note the mounting position of the filters! It must Mounting  
always be ensured that natural convection is not instructions,
 
point  
impaired.  
13  
Long motor cables  
Long motor cables cause parasitic currents in the  
Mounting  
installation. The cable lengths indicated for the output
 
instructions, point  
chokes and output filters serve for orientation. The  
user must check the technical parameters and  
especially the choke temperatures for the respective  
application.  
15  
Display of ordering codes for EPCOS products  
The ordering code for one and the same product can be represented differently in data sheets,  
data books, other publications and the website of EPCOS, or in order-related documents such as  
shipping notes, order confirmations and product labels. The varying representations of the  
ordering codes are due to different processes employed and do not affect the specifications of the  
respective products. Detailed information can be found on the Internet under  
Please read
C
autions and warnings
a
nd  
I
m
po
r
tant notes
a
t the end of this document.  
Page 11 of 13  

2-line filters  
B84142A*R000/G075  
for converters and power electronics  
Symbols and terms  
Symbol  
English  
German  
α
Insertion loss  
Einfügungsdämpfung  
Bemessungskapazität  
Kapazität X-Kondensator  
Kapazität Y-Kondensator  
Spannungsabfall im Filter  
Spannungsanstiegsgeschwindigkeit  
Frequenz  
C

R  

C

X  

C

Y  

∆
V  
dv/dt  
f
Rated capacitance  
Capacitance X capacitor  
Capacitance Y capacitor  
Voltage drop (input to output)  
Rate of voltage rise  
Frequency  
f

M  

f

P  

Converter output frequency  
Pulse frequency  
Motorfrequenz  
Pulsfrequenz  
f

R  

f

res  

I

C  

I

LK  

I

max  

I

N  

Rated frequency  
Bemessungsfrequenz  
Resonanzfrequenz  
Strom durch Kondensator  
Filter-Ableitstrom  
Maximalstrom  
Nennstrom  
Resonant frequency  
Current through capacitor  
Filter leakage current  
Maximum current  
Nominal current  
I

op  

I

pk  

I

q  

I

R  

Operating current (design current)  
Rated peak withstand current  
Capacitive reactive current  
Rated current  
Betriebsstrom  
Bemessungs-Stoßstromfestigkeit  
Kapazitiver Blindstrom  
Bemessungsstrom  
I

S  

L
Interference current  
Inductance  
Störstrom  
Induktivität  
L

R  

L

stray  

P

L  

R
Rated inductance  
Stray inductance  
Power loss  
Resistance  
Bemessungsinduktivität  
Streuinduktivität  
Verlustleistung  
Widerstand  
R

is  

R

typ  

T

A  

T

max  

T

min  

T

R  

u

k  

V

eff  

V

K  

V

LE  

V

N  

V

R  

V

peak  

V

test  

V

X  

V

Y  

X

L  

Z
Insulation resistance  
DC resistance, typical value  
Ambient temperature  
Upper category temperature  
Lower category temperature  
Rated temperature  
Refered voltage drop in %  
RMS voltage  
Isolationswiderstand  
Gleichstromwiderstand, Richtwert  
Umgebungstemperatur  
Obere Kategorietemperatur  
Untere Kategorietemperatur  
Bemessungstemperatur  
Bezogener Spannungsabfall in %  
Effektivdivnung  
Voltage drop  
Spannungsabfall  
Voltage line to earth; voltage line to ground
 
Spannung Phase zu Erdpotential  
Nominal voltage  
Rated voltage  
Peak voltage  
Nenndivnung  
Bemessungsdivnung  
Spitzendivnung  
Test voltage  
Prüfdivnung  
Voltage over X capacitor  
Voltage over Y capacitor  
Inductive reactance  
Impedance  
Spannung über X-Kondensator  
Spannung über Y-Kondensator  
Induktiver Blindwiderstand  
Scheinwidertand  
|Z|  
Impedance, absolute value  
Scheinwiderstand (Betragswert)  
Please read
C
autions and warnings
a
nd  
I
m
po
r
tant notes
a
t the end of this document.  
Page 12 of 13  

Important notes  
The following applies to all products named in this publication:  
1.
Some parts of this publication contain
statements about the suitability of our products for certain  
areas of application
. These statements are based on our knowledge of typical requirements that are  
often placed on our products in the areas of application concerned. We nevertheless expressly point  
out
that such statements cannot be regarded as binding statements about the suitability of our  
products for a particular customer application.
As a rule we are either unfamiliar with individual  
customer applications or less familiar with them than the customers themselves. For these reasons, it is  
always ultimately incumbent on the customer to check and decide whether a product with the properties  
described in the product specification is suitable for use in a particular customer application.  
2.
We also point out that
in individual cases, a malfunction of electronic components or failure  
before the end of their usual service life cannot be completely ruled out in the current state of the  
art, even if they are operated as specified.
In customer applications requiring a very high level of  
operational safety and especially in customer applications in which the malfunction or failure of an  
electronic component could endanger human life or health (e.g. in accident prevention or life-saving  
systems), it must therefore be ensured by means of suitable design of the customer application or other  
action taken by the customer (e.g. installation of protective circuitry or redundancy) that no injury or  
damage is sustained by third parties in the event of malfunction or failure of an electronic component.  
3.
The warnings, cautions and product-specific notes must b
e
observed.  
4.
In order to satisfy certain technical requirements,
some of the products described in this publication  
may contain substances subject to restrictions in certain jurisdictions (e.g. because they are  
classed as hazardous)
. Useful information on this will be found in our Material Data Sheets on the  
contact our sales offices.  
5.
We constantly strive to improve our products. Consequently,
the products described in this  
publication may change from time to time
. The same is true of the corresponding product  
specifications. Please check therefore to what extent product descriptions and specifications contained  
in this publication are still applicable before or when you place an order.  
We also
reserve the right to discontinue production and delivery of products
. Consequently, we  
cannot guarantee that all products named in this publication will
 
always be available.
 
The  
aforementioned does not apply in the case of individual agreements deviating from the foregoing for  
customer-specific products.  
6.
Unless otherwise agreed in individual contracts,
all orders are subject to our General Terms and  
Conditions of Supply.  
7.
Our manufacturing sites serving the automotive business apply the IATF 16949 standard.
The  
IATF certifications confirm our compliance with requirements regarding the quality management system  
in the automotive industry. Referring to customer requirements and customer specific requirements  
(“CSR”) TDK always has and will continue to have the policy of respecting individual agreements. Even  
if IATF 16949 may appear to support the acceptance of unilateral requirements, we hereby like to  
emphasize that
only requirements mutually agreed upon can and will be implemented in our  
Quality Management System.
For clarification purposes we like to point out that obligations from IATF  
16949 shall only become legally binding if individually agreed upon.  
8.
The trade names EPCOS, CeraCharge, CeraDiode, CeraLink, CeraPad, CeraPlas, CSMP, CTVS,  
DeltaCap, DigiSiMic, ExoCore, FilterCap, FormFit, LeaXield, MiniBlue, MiniCell, MKD, MKK, MotorCap,  
PCC, PhaseCap, PhaseCube, PhaseMod, PhiCap, PowerHap, PQSine, PQvar, SIFERRIT, SIFI,  
SIKOREL, SilverCap, SIMDAD, SiMic, SIMID, SineFormer, SIOV, ThermoFuse, WindCap are  
trademarks registered or pending
in Europe and in other countries. Further information will be found  
Release 2018-10  
Page 13 of 13