TDK-B84142A1600S081
| Part # | TDK-B84142A1600S081 |
| Download | TDK-B84142A1600S081 |
EMC filters
2-line filters
for converters and power electronics
Series/Type:
B84142A/C/J*S081
ꢀ
September
ꢀꢁꢂꢁ
2
Date:
©
ꢀ
TDK
ꢀ
Electronics
ꢀ
AG
ꢀ
2022
.
ꢀ
Reproduction,
ꢀ
publication
ꢀ
and
ꢀ
dissemination
ꢀ
of
ꢀ
this
ꢀ
publication,
ꢀ
enclosures
ꢀ
hereto
ꢀ
and
ꢀ
the
ꢀ
information
ꢀ
contained
ꢀ
therein
ꢀ
without
ꢀ
TDK
ꢀ
Electronics’
ꢀ
prior
ꢀ
express
ꢀ
consent
ꢀ
is
ꢀ
prohibited.
2-line filters
B84142A/C/J*S081
for converters and power electronics
EMC filters for DC systems and photovoltaics
Rated voltage V
R
: 1000 V DC and 1500 V DC
Rated current I
R
: 180 A to 1600 A
Construction
2-line filter
Metal case
Versions
Schematic picture
B84142A*S081 type for standard applications with high
voltages.
B84142C*S081 type with reduced Y capacitance for
higher asymmetrical currents and higher voltages.
B84142J*S081 type without Y capacitors, very low
leakage current.
Features
High
ꢀ
insertion
ꢀ
loss
Very
ꢀ
low
ꢀ
power
ꢀ
loss
+LJKꢀ’&ꢀ
voltage
Low
ꢀ
weight
Design
ꢀ
complies
ꢀ
with
ꢀ
IEC
ꢀ
60939,
ꢀ
UL
ꢀ
1283,
ꢀ
CSA
ꢀ
C22.2
ꢀ
No.8
UL
ꢀ
and
ꢀ
cUL
ꢀ
approval
ꢀ
(600
ꢀ
V
ꢀ
AC)
Typical applications
Photovoltaic modules
Wind farms
Power supplies
Terminals
Busbars
Marking
Marking on component:
Manufacturer’s logo, ordering code, rated voltage, rated
current, rated temperature, climatic category, date code,
approvals
Minimum data on packaging:
Manufacturer’s logo, ordering code, quantity, date code
Please read
Cautions and warnings
and
Important notes
at the end of this document.
Page 2 of 19
2-line filters
B84142A/C/J*S081
for converters and power electronics
Typical circuit diagrams
B84142A*S081
B84142C*S081
B84142J*S081
Please read
Cautions and warnings
and
Important notes
at the end of this document.
Page 3 of 19
2-line filters
B84142A/C/J*S081
for converters and power electronics
Technical data and measuring conditions
Rated voltage V
R,L
Rated voltage V
R,L
ꢀ
ꢀ
Type A*S081
Type C*S081
Type J*S081
1000 V DC
800 V DC
L
Gnd
1500 V DC
1500 V DC
1000 V DC
1000 V DC
Rated current I
R
Referred to 40
°
C rated temperature (250 A … 1600 A)
Referred to 60
°
C rated temperature (180 A)
Rated peak withstand current I
pk
Test voltage V
test
According IEC 60439-1:2011, chapter 3.8.10.2;
limited by I
2
t characteristics of fuse
Type A*S081 and
Type J*S081
3270 V DC, 2 s (line/line)
2890 V DC, 2 s (lines/case)
Type C*S081
4200 V DC, 2 s (line/line)
4200 V DC, 2 s (lines/case)
Overload capability (thermal)
1.5
ꢁ
I
R
for 3 min per hour or
2.5
ꢁ
I
R
for 30 s per hour
Climatic category (IEC 60068-1)
Approvals
25/100/21 (
ꢀ
25
°
C/+100
°
C/21 days damp heat test)
UL 1283, CSA C22.2 No.8 (600 V AC)
Please read
Cautions and warnings
and
Important notes
at the end of this document.
Page 4 of 19
2-line filters
B84142A/C/J*S081
for converters and power electronics
Characteristics and ordering codes
I
R
A
I
pk
kA
Terminal cross section
R
typ
Approx. weight
kg
Ordering code
Approvals
mm
2
m
Ω
V
R
= 1000 V DC
180
180
250
250
320
320
400
400
600
25
25
25
25
50
50
50
50
50
50
75
75
75
75
75
75
20
×
3
20
×
3
20
×
3
20
×
3
25
×
5
25
×
5
25
×
5
25
×
5
30
×
5
30
×
5
40
×
8
40
×
8
50
×
10
50
×
10
50
×
10
50
×
10
0.110 4.9
0.110 4.9
0.110 5.0
0.110 5.0
0.051 7.8
0.051 7.8
0.048 7.8
0.048 7.8
0.043 7.9
0.043 7.9
0.029 19.9
0.029 19.9
0.022 24.5
0.022 24.5
0.022 24.5
0.022 24.5
B84142A0180S081
×
B84142J0180S081
B84142A0250S081
×
B84142J0250S081
B84142A0320S081
×
B84142J0320S081
B84142A0400S081
×
B84142J0400S081
B84142A0600S081
×
B84142J0600S081
B84142A1000S081
×
B84142J1000S081
B84142A1250S081
×
B84142J1250S081
B84142A1600S081
×
B84142J1600S081
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
600
×
1000
1000
1250
1250
1600
1600
×
×
×
V
R
= 1500 V DC
180
250
320
400
600
1000
1250
1600
25
25
50
50
50
75
75
75
20
×
3
20
×
3
25
×
5
25
×
5
30
×
5
40
×
8
50
×
10
50
×
10
0.110 4.9
0.110 5.0
0.051 7.8
0.048 7.8
0.043 7.9
0.029 19.9
0.022 24.5
0.022 24.5
B84142C0180S081
×
B84142C0250S081
×
B84142C0320S081
×
B84142C0400S081
×
B84142C0600S081
×
B84142C1000S081
×
B84142C1250S081
×
B84142C1600S081
×
×
×
×
×
×
×
×
×
×
= Approval granted for 600 V AC
Please read
Cautions and warnings
and
Important notes
at the end of this document.
Page 5 of 19
2-line filters
B84142A/C/J*S081
for converters and power electronics
Dimensional drawings
B84142A/C/J0180S081, B84142A/C/J0250S081 (180 A, 250 A)
General tolerances according to ISO 2768
ꢀ
cL
Dimensions in mm
Busbar connection see section “Mechanical properties”
B84142A/C/J0320S081, B84142A/C/J0400S081 (320 A, 400 A)
General tolerances according to ISO 2768
ꢀ
cL
Dimensions in mm
Busbar connection see section “Mechanical properties”
Please read
Cautions and warnings
and
Important notes
at the end of this document.
Page 6 of 19
2-line filters
B84142A/C/J*S081
for converters and power electronics
B84142A/C/J0600S081 (600 A)
General tolerances according to ISO 2768
ꢀ
cL
Dimensions in mm
Busbar connection see section “Mechanical properties”
B84142A/C/J1000S081 (1000 A)
General tolerances according to ISO 2768
ꢀ
cL
Dimensions in mm
Busbar connection see section “Mechanical properties”
Please read
Cautions and warnings
and
Important notes
at the end of this document.
Page 7 of 19
2-line filters
B84142A/C/J*S081
for converters and power electronics
B84142A/C/J1250S081, B84142A/C/J1600S081 (1250 A, 1600 A)
General tolerances according to ISO 2768
ꢀ
cL
Dimensions in mm
Busbar connection see section “Mechanical properties”
Please read
Cautions and warnings
and
Important notes
at the end of this document.
Page 8 of 19
2-line filters
B84142A/C/J*S081
for converters and power electronics
Insertion loss
(typical values at Z = 50
Ω
)
Filters for 180 A and 250 A
Please read
Cautions and warnings
and
Important notes
at the end of this document.
Page 9 of 19
2-line filters
B84142A/C/J*S081
for converters and power electronics
Insertion loss
(typical values at Z = 50
Ω
)
Filters for 320 A and 400 A
Please read
Cautions and warnings
and
Important notes
at the end of this document.
Page 10 of 19
2-line filters
B84142A/C/J*S081
for converters and power electronics
Insertion loss
(typical values at Z = 50
Ω
)
Filters for 600 A
Please read
Cautions and warnings
and
Important notes
at the end of this document.
Page 11 of 19
2-line filters
B84142A/C/J*S081
for converters and power electronics
Insertion loss
(typical values at Z = 50
Ω
)
Filters for 1000 A
Please read
Cautions and warnings
and
Important notes
at the end of this document.
Page 12 of 19
2-line filters
B84142A/C/J*S081
for converters and power electronics
Insertion loss
(typical values at Z = 50
Ω
)
Filters for 1250 A and 1600 A
Please read
Cautions and warnings
and
Important notes
at the end of this document.
Page 13 of 19
2-line filters
B84142A/C/J*S081
for converters and power electronics
Cautions and warnings
Please read all warning and safety notes carefully before installing the filter and putting it into op-
eration (see
). The same applies to the warning signs on the filter. Please ensure that the signs
are not removed nor their legibility impaired by external influences.
Death, serious bodily injury and substantial material damage to equipment may occur if the appro-
priate safety measures are not carried out or the warnings in the text are not observed.
Using according to the terms
The filters may be used only for their intended application within the specified values in low-
voltage networks in compliance with the instructions given in the data sheets and the data book.
The conditions at the place of application must comply with all specifications for the filter used.
Warning
It shall be ensured that only qualified persons (electricity specialists) are engaged on work such
as planning, assembly, installation, operation, repair and maintenance. They must be provided
with the corresponding documentation.
Danger of electric shock. Filters contain components that store an electric charge. Dangerous
voltages can continue to exist at the filter terminals for longer than five minutes even after the
power has been switched off.
The protective earth connections shall be the first to be made when the filter is installed and the
last to be disconnected. Depending on the magnitude of the leakage currents, the particular
specifications for making the protective earth connection must be observed.
Impermissible overloading of the filter or filter, such as with circuits able to cause resonances,
impermissible voltages at higher frequencies etc. can lead to bodily injury and death as well as
cause substantial material damages (e.g. destruction of the filter housing).
Filters must be protected in the application against impermissible exceeding of the rated cur-
rents by overcurrent protective devices.
In case of leakage currents >3.5 mA you shall mount the PE conductor stationary with the re-
quired cross section before beginning of operation and save it against disconnecting. For leak-
age currents I
L
≤
10 mA the PE conductor must have a KU value
2)
of 4.5
3)
; for leakage currents
1)
I
L
>10 mA the PE conductor must have a KU value of 6
4)
.
Output chokes and output filters must be protected in the application against impermissible ex-
ceeding of the component temperature.
The converter output frequency must be within the specified range to avoid resonances and un-
controlled warming of the output chokes and output filters.
Because the product can become very hot during operation, there is the risk of burns if
touched. The product can remain hot for some time after the power is switched off!
1) I
L
= leakage current let-go
2) The
KU value (symbol KU) is a classification parameter of safety-referred failure types designed to ensure protection against hazardous
body currents and excessive heating.
3) A
value of KU = 4.5 with respect to interruptions is attained with: a) permanently connected protective earth connection
≥
1.5 mm
2
and
b) a protective earth connection
≥
2.5 mm
2
via connectors for industrial equipment (IEC 60309
ꢀ
2)
4) KU
= 6 with respect to interruptions is achieved for fixed-connection lines
≥
10 mm
2
where the type of connection and installation corre-
spond to the requirements for PEN conductors as specified in relevant standards.
Please read
Cautions and warnings
and
Important notes
at the end of this document.
Page 14 of 19
2-line filters
B84142A/C/J*S081
for converters and power electronics
The table below summarizes the safety instructions that must be observed without fail. A detailed
description can be found in the relevant chapters of the databook.
Reference chapter
(data book),
Topic
Instructions
paragraph
Selecting a filter
When selecting a filter, it is mandatory to observe the
Selection guide for
rated data of the equipment (such as its rated input
current, rated voltage, harmonic content etc.) as well
as the derating instructions in Chapters 9 and 10.
converter filters
Rated voltage
When power distribution systems deviating from the
symmetric TN-S system is to check the suitability of
the filters and the allowed voltages including the fault
cases.
Power distribution
systems,
7
Protection from
Active parts must be discharged within 5 s to a Safety
regulations,
residual voltages
voltage of less than 60 V (or 50
μ
C). If this limit
6.1
Discharge resistors
cannot be observed due to the operating mode, the
hazardous point must be permanently marked in a
clearly visible way.
Filters which are not permanently connected (e.g.
when the test voltage is applied to the filter at the
incoming goods inspection) must be discharged after
the voltage has been switched off.
Safety regulations,
6.2
Installing and
removing of filters
When installing and removing our filters, a
Safety regulations,
voltage-free state must be set up and secured with
6.4
observance of the five safety rules described in
EN 50110-1.
Installation
Use in IT systems
The special features of the IT system (“first fault case”
Power distribution
and other fault cases) shall be observed.
system (network
types), 7.6
Safety notes on
leakage currents
The filter leakage currents specified in the data book
Leakage current,
are intended for user information only.The maximum
8.4
leakage current of the entire electrical equipment or
Leakage current,
appliance has to be limited for safety reasons. Please
8.6
obtain the applicable limits for your application from
the relevant regulations, provisions and standards.
Voltage derating
If the permissible limits for the higher-frequency Voltage
derating,
voltages at the filter are exeeded, the filter may be
9.8
damaged or destroyed.
Hazards caused by
overloading the
filters
Current derating at
Non-observance of the current derating may lead to
Current derating,
elevated ambient
temperatures
overheating and consequently represents a fire 10.1
hazard.
Please read
Cautions and warnings
and
Important notes
at the end of this document.
Page 15 of 19
2-line filters
B84142A/C/J*S081
for converters and power electronics
Reference chapter
(data book),
Topic
Instructions
paragraph
Protective earth
connection at
For operating currents greater than 250 A, we Mounting
recommend the PE connection to be set up between
instructions,
operating currents
the feed (filter: line) and output (filter: load) not via the
point 2
>250 A
PE terminal bolt in the filter housing.
Mounting position
Note the mounting position of the filters! It must Mounting
always be ensured that natural convection is not instructions,
impaired.
point 13
Long motor cables
Long motor cables cause parasitic currents in the
Mounting
installation. The cable lengths indicated for the output
instructions,
chokes and output filters serve for orientation. The
user must check the technical parameters and
especially the choke temperatures for the respective
application.
point 15
Display of ordering codes for TDK Electronics products
The ordering code for one and the same product can be represented differently in data sheets,
data books, other publications, on the company website, or in order-related documents such as
shipping notes, order confirmations and product labels.
The varying representations of the or-
dering codes are due to different processes employed and do not affect the specifications
of the respective products
.
Detailed information can be found on the Internet under
Please read
Cautions and warnings
and
Important notes
at the end of this document.
Page 16 of 19
2-line filters
B84142A/C/J*S081
for converters and power electronics
Symbols and terms
Symbol English
German
α
Insertion loss
Einfügungsdämpfung
Bemessungskapazität
Kapazität X-Kondensator
Kapazität Y-Kondensator
Spannungsabfall (Eingang zu Ausgang)
Spannungsanstiegsgeschwindigkeit
Frequenz
C
R
C
X
C
Y
Δ
V
dv/dt
f
Rated capacitance
Capacitance X capacitor
Capacitance Y capacitor
Voltage drop (input to output)
Rate of voltage rise
Frequency
f
M
f
P
Converter output frequency
Pulse frequency
Motorfrequenz
Pulsfrequenz
f
R
f
res
I
C
I
LK
I
max
I
N
Rated frequency
Bemessungsfrequenz
Resonanzfrequenz
Strom durch Kondensator
Filter-Ableitstrom
Maximalstrom
Nennstrom
Resonant frequency
Current through capacitor
Filter leakage current
Maximum current
Nominal current
I
op
I
pk
I
q
I
R
Operating current (design current)
Rated peak withstand current
Capacitive reactive current
Rated current
Betriebsstrom
Bemessungs-Stoßstromfestigkeit
Kapazitiver Blindstrom
Bemessungsstrom
I
S
L
Interference current
Inductance
Störstrom
Induktivität
L
R
L
stray
P
L
R
Rated inductance
Stray inductance
Power loss
Resistance
Bemessungsinduktivität
Streuinduktivität
Verlustleistung
Widerstand
R
is
R
typ
T
A
T
max
T
min
T
R
u
k
V
eff
V
K
V
LE
V
N
V
R
V
peak
V
test
V
X
V
Y
X
L
Z
Insulation resistance
DC resistance, typical value
Ambient temperature
Upper category temperature
Lower category temperature
Rated temperature
Referred voltage drop in %
RMS voltage
Isolationswiderstand
Gleichstromwiderstand typisch
Umgebungstemperatur
Obere Kategorietemperatur
Untere Kategorietemperatur
Bemessungstemperatur
Bezogener Spannungsabfall in %
Effektivdivnung
Voltage drop
Spannungsabfall
Voltage line to earth; voltage line to ground
Spannung Phase zu Erdpotential
Nominal voltage
Rated voltage
Peak voltage
Nenndivnung
Bemessungsdivnung
Spitzendivnung
Test voltage
Prüfdivnung
Voltage over X capacitor
Voltage over Y capacitor
Inductive reactance
Impedance
Spannung über X-Kondensator
Spannung über Y-Kondensator
Induktiver Blindwiderstand
Scheinwiderstand
|Z|
Impedance, absolute value
Scheinwiderstand (Betragswert)
Please read
Cautions and warnings
and
Important notes
at the end of this document.
Page 17 of 19
Important notes
The following applies to all products named in this publication:
1.
Some parts of this publication contain
statements about the suitability of our products for
certain areas of application
. These statements are based on our knowledge of typical re-
quirements that are often placed on our products in the areas of application concerned. We
nevertheless expressly point out
that such statements cannot be regarded as binding
statements about the suitability of our products for a particular customer application
.
As a rule, we are either unfamiliar with individual customer applications or less familiar with
them than the customers themselves. For these reasons, it is always ultimately incumbent on
the customer to check and decide whether a product with the properties described in the
product specification is suitable for use in a particular customer application.
2.
We also point out that
in individual cases, a malfunction of electronic components or
failure before the end of their usual service life cannot be completely ruled out in the
current state of the art, even if they are operated as specified
. In customer applications
requiring a very high level of operational safety and especially in customer applications in
which the malfunction or failure of an electronic component could endanger human life or
health (e.g. in accident prevention or lifesaving systems), it must therefore be ensured by
means of suitable design of the customer application or other action taken by the customer
(e.g. installation of protective circuitry or redundancy) that no injury or damage is sustained by
third parties in the event of malfunction or failure of an electronic component.
3.
The warnings, cautions and product-specific notes must be observed.
4.
In order to satisfy certain technical requirements,
some of the products described in this
publication may contain substances subject to restrictions in certain jurisdictions (e.g.
because they are classed as hazardous)
. Useful information on this will be found in our Ma-
any more detailed questions, please contact our sales offices.
5.
We constantly strive to improve our products. Consequently,
the products described in this
publication may change from time to time
. The same is true of the corresponding product
specifications. Please check therefore to what extent product descriptions and specifications
contained in this publication are still applicable before or when you place an order. We also
reserve the right to discontinue production and delivery of products
. Consequently, we
cannot guarantee that all products named in this publication will always be available. The
aforementioned does not apply in the case of individual agreements deviating from the fore-
going for customer-specific products.
6.
Unless otherwise agreed in individual contracts,
all orders are subject to our General
Terms and Conditions of Supply
.
Page 18 of 19
Important notes
7.
Our manufacturing sites serving the automotive business apply the IATF 16949 stan-
dard.
The IATF certifications confirm our compliance with requirements regarding the quality
management system in the automotive industry. Referring to customer requirements and cus-
tomer specific requirements (“CSR”) TDK always has and will continue to have the policy of
respecting individual agreements. Even if IATF 16949 may appear to support the acceptance
of unilateral requirements, we hereby like to emphasize that
only requirements mutually
agreed upon can and will be implemented in our Quality Management System.
For clari-
fication purposes we like to point out that obligations from IATF 16949 shall only become
legally binding if individually agreed upon.
8.
The trade names EPCOS, CarXield, CeraCharge, CeraDiode, CeraLink, CeraPad, CeraPlas,
CSMP, CTVS, DeltaCap, DigiSiMic, ExoCore, FilterCap, FormFit, LeaXield, MiniBlue,
MiniCell, MKD, MKK, ModCap, MotorCap, PCC, PhaseCap, PhaseCube, PhaseMod, PhiCap,
PowerHap, PQSine,
PQvar, SIFERRIT, SIFI, SIKOREL, SilverCap, SIMDAD, SiMic, SIMID,
SineFormer, SIOV, ThermoFuse, WindCap, XieldCap are
trademarks registered or pend-
ing
in Europe and in other countries. Further information will be found on the Internet at
Release 2020-06
Page 19 of 19