TDK-B84143A0020R107
| Part # | TDK-B84143A0020R107 |
| Download | TDK-B84143A0020R107 |
EMC filters
3-line filters
for converters and power electronics
Series/Type:
B84143A*R107
Date:
June
2021
TDK Electronics AG 2021. Reproduction, publication and dissemination of this publication, enclosures hereto
and the information contained therein without TDK Electronics’ prior express consent is prohibited.
3-line filters
B84143A*R107
for converters and power electronics
Power line filters for 3-phase systems
Rated voltage V
R
: 300/520 V AC
Rated current I
R
: 10 A to 100 A
Construction
3-line filters
Metal case
Schematic picture
Features
High insertion loss
Optimized leakage current
Discharge time < 60 V in 1 s for V
R
(L-L)
≤
400 V
Easy to install
Low weight
Compact design
Degree of protection: IP 20
1)
Short circuit current rating SCCR:
35 A … 100 A: 50 kA
ENEC, UL and cUL approval
Typical applications
Frequency converters for motor drives, e.g.
– elevators
– pumps
– conveyor
systems
– HVAC
systems (heating, ventilation and air conditioning)
Power supplies
Textile machines, packaging machines, machine-tools
Terminals
Finger-safe terminals
Marking
Marking on component:
Manufacturer’s logo, ordering code, rated voltage, rated
current, rated temperature, climatic category, date code,
approvals, SCCR value
Minimum data on packaging:
Manufacturer’s logo, ordering code, quantity, date code
1) According
to IEC 60529
Please read
Cautions and warnings
and
Important notes
at the end of this document.
2
6
/21
3-line filters
B84143A*R107
for converters and power electronics
Typical circuit diagrams
Technical data and measuring conditions
Rated voltage V
R
300/520 V AC (50/60 Hz)
265/460 V AC (50/60 Hz)
See also chapter “Technical information”, section 8 “Energy
supply networks”.
Rated voltage for IT mains
supply
Rated current I
R
T
e
st voltage V
test
Referred to 50
°
C rated temperature
2236 V DC, 2 s (line/line)
2720 V DC, 2 s (line/case)
Overload capability (thermal)
1.5 I
R
for 3 min per hour or
2.5 I
R
for 30 s per hour
Leakage current l
LK
Climatic category (IEC 60068-1)
Approvals
At V
R
and 50 Hz
25/100/21 (-25
°
C/+100
°
C/21 days damp heat test)
IEC 60939, UL 1283, CSA C22.2 No.8
Please read
Cautions and warnings
and
Important notes
at the end of this document.
3
6
/21
3-line filters
B84143A*R107
for converters and power electronics
Characteristics and ordering codes
I
R
Terminal cross
I
LK
section
R
typ
Approx.
weight
Ordering code
Approvals
A
mm
2
mA
m
Ω
kg
V
R
= 300/520 V AC
10
20
35
50
65
80
4
3.1
3.1
3.4
3.4
3.4
3.4
3.4
5.5
3.3
1.7
1.1
0.4
0.6
0.9
1.4
B84143A0010R107
B84143A0020R107
B84143A0035R107
B84143A0050R107
B84143A0065R107
B84143A0080R107
B84143A0100R107
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
4
10
25
25
25
0.94 1.9
0.60 2.4
0.48 2.9
100 50
x = Approval granted
SCCR values
50 kA for 35 A … 65 A types, nominal values of circuit breaker
80 A and V
[L–PE / L–L]
min. 347/600 V
50 kA for 80 A … 100 A types, nominal values of circuit breaker
125 A and V
[L–PE / L–L]
min. 347/600 V
Please read
Cautions and warnings
and
Important notes
at the end of this document.
4
6/
21
3-line filters
B84143A*R107
for converters and power electronics
Dimensional drawings
B84143A0010R107, B84143A0020R107 (10 A, 20 A)
General tolerances according to ISO 2768-cL
Dimensions in mm
Please read
Cautions and warnings
and
Important notes
at the end of this document.
5
6
/21
3-line filters
B84143A*R107
for converters and power electronics
B84143A0035R107 (35 A)
General tolerances according to ISO 2768-cL
Dimensions in mm
Please read
Cautions and warnings
and
Important notes
at the end of this document.
6
6
/21
3-line filters
B84143A*R107
for converters and power electronics
B84143A0050R107, B84143A0065R107 (50 A, 65 A)
General tolerances according to ISO 2768-cL
Dimensions in mm
Please read
Cautions and warnings
and
Important notes
at the end of this document.
7
6
/21
3-line filters
B84143A*R107
for converters and power electronics
B84143A0080R107 (80 A)
General tolerances according to ISO 2768-cL
Dimensions in mm
Please read
Cautions and warnings
and
Important notes
at the end of this document.
8
6
/21
3-line filters
B84143A*R107
for converters and power electronics
B84143A0100R107 (100 A)
General tolerances according to ISO 2768-cL
Dimensions in mm
Please read
Cautions and warnings
and
Important notes
at the end of this document.
9
6
/21
3-line filters
B84143A*R107
for converters and power electronics
Insertion loss
(typical values at Z = 50
Ω
)
unsymmetrical, adjacent branches terminated
common mode, all branches in parallel (asymmetrical)
differential mode (symmetrical)
. . . . .
Filters for 10 A
Filters for 20 A
Filters for 35 A
Filters for 50 A
Please read
Cautions and warnings
and
Important notes
at the end of this document.
10
6
/21
3-line filters
B84143A*R107
for converters and power electronics
Insertion loss
(typical values at Z = 50
Ω
)
unsymmetrical, adjacent branches terminated
common mode, all branches in parallel (asymmetrical)
differential mode (symmetrical)
. . . . .
Filters for 65 A
Filters for 80 A
Filters for 100 A
Please read
Cautions and warnings
and
Important notes
at the end of this document.
11
6
/21
3-line filters
B84143A*R107
for converters and power electronics
Cautions and warnings
Please read all warning and safety notes carefully before installing the filter and putting it into op-
eration (see
). The same applies to the warning signs on the filter. Please ensure that the signs
are not removed nor their legibility impaired by external influences.
Death, serious bodily injury and substantial material damage to equipment may occur if the appro-
priate safety measures are not carried out or the warnings in the text are not observed.
Using according to the terms
The filters may be used only for their intended application within the specified values in low-
voltage networks in compliance with the instructions given in the data sheets and the data book.
The conditions at the place of application must comply with all specifications for the filter used.
Warning
It shall be ensured that only qualified persons (electricity specialists) are engaged on work such
as planning, assembly, installation, operation, repair and maintenance. They must be provided
with the corresponding documentation.
Danger of electric shock. Filters contain components that store an electric charge. Dangerous
voltages can continue to exist at the filter terminals for longer than five minutes even after the
power has been switched off.
The protective earth connections shall be the first to be made when the filter is installed and the
last to be disconnected. Depending on the magnitude of the leakage currents, the particular
specifications for making the protective earth connection must be observed.
Impermissible overloading of the filter or filter, such as with circuits able to cause resonances,
impermissible voltages at higher frequencies etc. can lead to bodily injury and death as well as
cause substantial material damages (e.g. destruction of the filter housing).
Filters must be protected in the application against impermissible exceeding of the rated cur-
rents by overcurrent protective devices.
In case of leakage currents >3.5 mA you shall mount the PE conductor stationary with the re-
quired cross section before beginning of operation and save it against disconnecting. For leak-
1)
age currents I
L
≤
10 mA the PE conductor must have a KU value
2)
of 4.5
3
)
; for leakage currents
I
L
>10 mA the PE conductor must have a KU value of 6
4)
.
Output chokes and output filters must be protected in the application against impermissible ex-
ceeding of the component temperature.
The converter output frequency must be within the specified range to avoid resonances and un-
controlled warming of the output chokes and output filters.
Because the product can become very hot during operation, there is the risk of burns if
touched. The product can remain hot for some time after the power is switched off!
1) I =
leakage current let-go
L
2) The
KU value (symbol KU) is a classification parameter of safety-referred failure types designed to ensure protection
against hazardous body currents and excessive heating.
3) A
value of KU = 4.5 with respect to interruptions is attained with: a) permanently connected protective earth connection
2
2
≥
1.5 mm
and b) a protective earth connection
≥
2.5 mm
via connectors for industrial equipment (IEC 60309-2)
2
4) KU
= 6 with respect to interruptions is achieved for fixed-connection lines
≥
10 mm
where the type of connection and
installation correspond to the requirements for PEN conductors as specified in relevant standards.
Please read
Cautions and warnings
and
Important notes
at the end of this document.
12
6
/21
3-line filters
B84143A*R107
for converters and power electronics
The table below summarizes the safety instructions that must be observed without fail. A detailed
description can be found in the relevant chapters of the databook.
Topic
Instructions
Referenc
e
c
hapter
(data book),
paragraph
Selecting a filter
When selecting a filter, it is mandatory to observe the
Selection guide for
rated data of the equipment (such as its rated input cur-
converter filters
rent, rated voltage, harmonic content etc.) as well as
the derating instructions in Chapters 9 and 10.
Rated voltage
When power distribution systems deviating from the
Power distribution
symmetric TN-S system is to check the suitability of the
systems,
filters and the allowed voltages including the fault
7
cases.
Protection from
residual voltages
Active parts must be discharged within 5 s to a volt-
Safety regulations,
age of less than 60 V (or 50 µC). If this limit
cannot 6.1
Discharge resistors
be observed due to the operating mode, the hazard-
ous point must be permanently marked in a
clearly
visible way.
Filters which are not permanently connected (e.g. Safety
regulations,
when the test voltage is applied to the filter at the
6.2
incoming goods inspection) must be discharged after
the voltage has been switched off.
Installing and
When installing and removing our filters, a voltage-free
Safety regulations,
removing of filters
state must be set up and secured with
observance 6.4
of the five safety
rules described in
EN 50110-1.
Installation
Use in IT systems
The special features of the IT system (“first fault case”
Power distribution
and other fault cases) shall be observed.
system
(network types),
7.6
Safety notes on
leakage currents
The filter leakage currents specified in the data book
Leakage current,
are intended for user information only.The maximum
8.4
leakage current of the entire electrical equipment or
Leakage current,
appliance has to be limited for safety reasons. Please
8.6
obtain the applicable limits for your application from
the relevant regulations, provisions and standards.
Voltage derating
If the permissible limits for the higher-frequency
volt- Voltage
derating,
ages at the filter are exeeded, the filter may be 9.8
damaged or destroyed.
Hazards caused by
overloading the
filters
Current derating at
Non-observance of the current derating may lead to
Current derating,
elevated ambient
temperatures
overheating and consequently represents a fire 10.1
hazard.
Please read
Cautions and warnings
and
Important notes
at the end of this document.
13
6
/21
3-line filters
B84143A*R107
for converters and power electronics
Topic
Instructions
Referenc
e
c
hapter
(data book),
paragraph
Protective earth
connection at
For operating currents greater than 250 A, we
re- Mounting
commend the PE connection to be set up between the
instructions,
operating currents
feed (filter: line) and output (filter: load) not via the
point 2
>250 A
PE terminal bolt in the filter housing.
Mounting position
Note the mounting position of the filters! It must al-
Mounting
ways be ensured that natural convection is not im-
instructions,
paired.
point 13
Long motor cables
Long motor cables cause parasitic currents in the in-
Mounting
stallation. The cable lengths indicated for the output
instructions,
chokes and output filters serve for orientation. The user
point 15
must check the technical parameters and especially
the choke temperatures for the respective application.
Display of ordering codes for TDK Electronics products
The ordering code for one and the same product can be represented differently in data sheets, data
books, other publications, on the company website, or in order-related documents such as shipping
notes, order confirmations and product labels.
The varying representations of the ordering
codes are due to different processes employed and do not affect the specifications of the
respective products
.
Detailed information can be found on the Internet under
Please read
Cautions and warnings
and
Important notes
at the end of this document.
14
6
/21
3-line filters
B84143A*R107
for converters and power electronics
Symbols and terms
Symbol English
German
α
Insertion loss
Einfügungsdämpfung
Bemessungskapazität
C
R
C
X
C
Y
Δ
V
dv/dt
f
Rated capacitance
Capacitance X capacitor
Capacitance Y capacitor
Voltage drop (input to output)
Rate of voltage rise
Frequency
Kapazität X-Kondensator
Kapazität Y-Kondensator
Spannungsabfall (Eingang zu Ausgang)
Spannungsanstiegsgeschwindigkeit
Frequenz
f
M
Converter output frequency
Pulse frequency
Motorfrequenz
f
P
Pulsfrequenz
f
R
Rated frequency
Bemessungsfrequenz
Resonanzfrequenz
Strom durch Kondensator
Filter-Ableitstrom
f
res
I
C
Resonant frequency
Current through capacitor
Filter leakage current
Maximum current
I
LK
I
max
I
N
Maximalstrom
Nominal current
Nennstrom
I
op
I
pk
Operating current (design current)
Rated peak withstand current
Capacitive reactive current
Rated current
Betriebsstrom
Bemessungsstoßstromfestigkeit
Kapazitiver Blindstrom
Bemessungsstrom
I
q
I
R
I
S
Interference current
Inductance
Störstrom
L
Induktivität
L
R
Rated inductance
Bemessungsinduktivität
Streuinduktivität
L
stray
P
L
Stray inductance
Power loss
Verlustleistung
R
Resistance
Widerstand
R
is
R
typ
T
A
T
max
T
min
T
R
V
eff
V
K
v
k
Insulation resistance
DC resistance, typical value
Ambient temperature
Upper category temperature
Lower category temperature
Rated temperature
RMS voltage
Isolationswiderstand
Gleichstromwiderstand typisch
Umgebungstemperatur
Obere Kategorietemperatur
Untere Kategorietemperatur
Bemessungstemperatur
Effektivdivnung
Voltage drop
Spannungsabfall
Referred voltage drop in %
Voltage line to earth; voltage line to ground
Nominal voltage
Bezogener Spannungsabfall in %
Spannung Phase zu Erdpotential
Nenndivnung
V
LE
V
N
V
R
V
peak
V
test
Rated voltage
Bemessungsdivnung
Spitzendivnung
Peak voltage
Test voltage
Prüfdivnung
Please read
Cautions and warnings
and
Important notes
at the end of this document.
15
6
/21
3-line filters
B84143A*R107
for converters and power electronics
Symbol English
German
V
X
V
Y
X
L
Z
Voltage over X capacitor
Voltage over Y capacitor
Inductive reactance
Impedance
Spannung über X-Kondensator
Spannung über Y-Kondensator
Induktiver Blindwiderstand
Scheinwiderstand
|Z|
Impedance, absolute value
Scheinwiderstand (Betragswert)
Please read
Cautions and warnings
and
Important notes
at the end of this document.
16
6
/21
Important notes
The following applies to all products named in this publication:
1. Some
parts of this publication contain
statements about the suitability of our products for
certain areas of application
. These statements are based on our knowledge of typical
requirements that are often placed on our products in the areas of application concerned. We
nevertheless expressly point out
that such statements cannot be regarded as binding
statements about the suitability of our products for a particular customer application.
As
a rule, we are either unfamiliar with individual customer applications or less familiar with them
than the customers themselves. For these reasons, it is always ultimately incumbent on the
customer to check and decide whether a product with the properties described in the product
specification is suitable for use in a particular customer application.
2. We
also point out that
in individual cases, a malfunction of electronic components or
failure before the end of their usual service life cannot be completely ruled out in the
current state of the art, even if they are operated as specified.
In customer applications
requiring a very high level of operational safety and especially in customer applications in which
the malfunction or failure of an electronic component could endanger human life or health (e.g.
in accident prevention or life-saving systems), it must therefore be ensured by means of suitable
design of the customer application or other action taken by the customer (e.g. installation of
protective circuitry or redundancy) that no injury or damage is sustained by third parties in the
event of malfunction or failure of an electronic component.
3.
The warnings, cautions and product-specific notes must be observed
.
4. In
order to satisfy certain technical requirements,
some of the products described in this
publication may contain substances subject to restrictions in certain jurisdictions (e.g.
because they are classed as hazardous)
. Useful information on this will be found in our
any more detailed questions, please contact our sales offices.
5. We
constantly strive to improve our products. Consequently,
the products described in this
publication may change from time to time
. The same is true of the corresponding product
specifications. Please check therefore to what extent product descriptions and specifications
contained in this publication are still applicable before or when you place an order.
We also
reserve the right to discontinue production and delivery of products
.
Consequently, we cannot guarantee that all products named in this publication will always be
available. The aforementioned does not apply in the case of individual agreements deviating
from the foregoing for customer-specific products.
6. Unless
otherwise agreed in individual contracts,
all orders are subject to our General Terms
and Conditions of Supply
.
17
6
/21
Important notes
7.
Our manufacturing sites serving the automotive business apply the IATF 16949
standard
. The IATF certifications confirm our compliance with requirements regarding the
quality management system in the automotive industry. Referring to customer requirements
and customer specific requirements (“CSR”) TDK always has and will continue to have the
policy of respecting individual agreements. Even if IATF 16949 may appear to support the
acceptance of unilateral requirements, we hereby like to emphasize that
only requirements
mutually agreed upon can and will be implemented in our Quality Management System.
For clarification purposes we like to point out that obligations from IATF 16949 shall only
become legally binding if individually agreed upon.
8. The
trade names EPCOS, CarXield, CeraCharge, CeraDiode, CeraLink, CeraPad, CeraPlas,
CSMP,
CTVS, DeltaCap, DigiSiMic, ExoCore, FilterCap, FormFit, LeaXield, MiniBlue,
MiniCell, MKD, MKK, ModCap, MotorCap, PCC, PhaseCap, PhaseCube, PhaseMod, PhiCap,
PowerHap, PQSine, PQvar, SIFERRIT, SIFI, SIKOREL, SilverCap, SIMDAD, SiMic, SIMID,
SineFormer, SIOV, ThermoFuse, WindCap, XieldCap are
trademarks registered or pending
in Europe and in other countries. Further information will be found on the Internet at
Release 2020-06
18
6
/21