TE-Connectivity-1-1617088-4
CII Low Signal Relays  
Double Pole, Magnetic Latching, 2 Amps and Less
(Continued)  
Electrical Characteristics  
Contact Ratings
—  
Operating Characteristics  
Magnetic Latching,  
Grid-space, Relays  
Operate Time
— 4 ms  
Release Time
— 4 ms  
Contact Bounce
— 2 ms  
Dielectric Strength
—  
1,000 volts rms at sea level;  
700 volts rms across contact gap  
DC resistive — 2 amps at 28 volts  
DC inductive — 0.5 amps at 28 volts,  
200 mH  
AC resistive — 1 amp at 115 volts  
(single coil), case not grounded  
AC resistive — 0.25 amps at 115 volts  
(dual coil), case not grounded  
Low-level — 50 µA at 50 mV  
Peak AC or DC  
Type 3SAM (2PDT)  
1
Product Facts  
n
Special shock designs up to  
700 G, 1 ms  
Insulation Resistance
—  
1,000 megohm min.  
n
Suitable for pulse operation  
Environmental Characteristics  
Vibration
— 30 G, to 3,000 Hz  
Shock
— 150 G at 11 ms  
Contact Resistance
—  
0.050 ohms initial;  
0.100 ohms after life test  
n
No hang up feature on low  
power pulses  
This relay has “memory” in  
that the contact positions do  
not change when coil power  
is removed. Switching is  
accomplished by applying  
power to the applicable coil  
(dual coil) or with the appli-  
cable polarity (single coil).  
The low switching power  
requirements are further  
enhanced by its ability to  
operate from capacitor dis-  
charge or other pulses or  
through its own contacts for  
batteries or similarly limited  
supplies.  
Temperature
— -65°C to +125°C  
Life
—  
n
Qualified to MIL-R-39016/32  
n
Special wiring is available  
100,000 operations at rated load;  
1,000,000 at low-level  
See page 1-52 for Mounting Forms,  
T
e
rminals and Circuit Diagrams.  
† Applicable over the operating temperature range in circulating air.  
‡ Initial or inspection value. Allow 20% increase in value of maximum pickup  
during rated life.  
† Applicable over the operating temperature range in circulating air.  
‡ Initial or inspection value. Allow 20% increase in value of maximum pickup  
during rated life.  
of these relay characteristics, the  
catalog number is identified as  
3SAM6014N2. The letter R following  
sensitivity code indicates relay  
received 5000 operation miss-test.  
Ex. 3SAM6014N2R.  
Ordering Instructions  
Example:
The relay selected in this  
example is a 2PDT magnetic latch-  
ing relay, current calibrated, four-  
hole end bracket mounting, solder  
hook heade
r
,
1
500 ohms coil resist-  
ance, and 75 mW sensitivit
y
.
B
y  
choosing the proper code for each  
*
The part number example shown on this page is for catalog items. For a list of specific QPL part numbers, please see the index in Section 15.  
1-51  
Catalog 5-1773450-5  
Revised 3-13  
Dimensions are shown for  
reference purposes only.  
Specifications subject  
to change.  
Dimensions are in millimeters  
unless otherwise specified.  
USA: +1 800 522 6752  
Asia Pacific: +86 0 400 820 6015  
UK: +44 800 267 666  
For additional support numbers  

CII Low Signal Relays  
Double Pole, Magnetic Latching, 2 Amps and Less
(Continued)  
Mounting Forms (3SAM)  
(Vibration note with each  
form is acceleration from  
55 to 3000 Hz)  
Header and Connection Diagrams  
Header Types  
1-52  
Catalog 5-1773450-5  
Revised 3-13  
Dimensions are shown for  
Dimensions are in millimeters  
unless otherwise specified.  
USA: +1 800 522 6752  
Asia Pacific: +86 0 400 820 6015  
UK: +44 800 267 666  
For additional support numbers  
reference purposes only.  
Specifications subject  