5 to 10 Amp  
General Purpose Relay  
File E29244, E22575  
File LR15734  
Users should thoroughly review the technical data before selecting a product  
part number. It is recommended that users also seek out the pertinent approvals  
files of the agencies/laboratories and review them to ensure the product meets  
the requirements for a given application.  
KRPA  
KRP  
KA  
Coil Data @ 25°C  
Features  
Nominal Power  
Maximum Power  
• Industry standard octal-type termination for quick installation.  
• Contact arrangements from 1 Form C (SPDT) to 3 Form C (3PDT).  
• Indicator lamp and push-to-test options available on certain models.  
• The KRPA is the automated manufactured version of the KR
P
.  
KRP  
KRPA  
KA  
AC  
DC  
AC  
DC  
2VA  
1
.
2W  
2VA  
Enclosed Models – 4VA  
Enclosed Models – 3W  
Open Models – 4VA  
Open Models – 4W  
125mW per movable arm  
Duty Cycle:
 
Continuous.  
Initial Insulation Resistance:
 
KR
P
,
K
RPA – 1000 Megohms, min.  
Contact Data @ 25°C  
Arrangements:
See Ordering Information
T
a
ble.  
Materials:
Silver or silve
r
–
cadmium oxide, with or without gold flashing.  
Expected Life:
 
10 million operations min., mechanical; 100,000  
operations min. @ rated loads.  
KA – 100 Megohms, min.  
Coil Data @ 25°C  
Nominal  
V
o
ltage  
DC Resistance (
Ω
)  
Nominal Coil  
Current (mA)  
10%  
KA, KR
P
,
K
RPA  
Contact Code  
UL/CSA Contact Ratings @ 25°C  
Arrangement  
Contact Rating  
6
12  
24  
48  
110  
220  
6
12  
24  
32  
120  
472  
1
,
800  
10,000  
188  
1
0
0  
51  
26.6  
11
.
5  
Y
1,
2
, 3 Poles  
5A @ 120VAC  
3A @ 240VAC  
DC  
Coils  
(Silver)  
1/10HP @ 120VAC  
1/6HP @ 240VAC  
Use
1
1
0
V relay with 10,000
Ω
5W Resistor in series  
G&N  
(Silve
r
–
Cad.  
Oxide)  
1,
2
, 3 Poles  
10A @ 240VAC  
1/2 HP @ 240VAC  
1/3HP @ 120VAC  
6
24  
85  
335  
168  
84  
AC  
Coils  
120  
240  
2,250  
9
,
110  
1
7
.
5  
8.75  
KR
P
,
K
RPA  
Factory Ratings  
Contact Code  
Arrangement  
1,
2
, 3 Poles  
1,
2
, 3 Poles  
Contact Rating  
Y
5A @ 28VDC, 120VAC, 80% PF  
Operate Data @ 25°C  
Must-Operate
V
o
ltage:  
G&N  
10A @ 28VDC, 120VAC, 80% PF  
6A @ 250VAC  
DC:
75% or less of nominal voltage.  
AC:
85% or less of nominal voltage.  
Operate Time (Excluding Bounce):  
15 milliseconds typical @ nominal voltage.  
Release Time (Excluding Bounce):  
10 milliseconds typical @ nominal voltage.  
KA UL Contact Ratings  
Contact Code  
Series  
Contact Ratings  
1
KA  
Y
5A @ 120VAC, 3A @ 240VAC,  
1/10 HP @ 120VAC, 1/6 HP @ 240VAC  
2
G
KA  
10A @ 120VAC, 6A @ 240VAC  
1/6 HP @ 120VAC, 1/3 HP @ 240VAC  
Environmental Data  
T
e
mperature Range:  
Open Models:
 
AC:
-45°C to +70°C.  
DC:
-45°C to +85°C.  
Enclosed Models:
 
AC:
-45°C to +55°C.  
DC:
-45°C to +70°C.  
1
2
Listed by C.S.A. for 5A @ 120VAC 80% PF  
Listed by C.S.A. for 10A @ 120VAC 80% PF  
Note:
See KRPA, KR
P
,
K
A Ordering Information table.  
Initial Dielectric Strength  
Mechanical Data  
Between Open Contacts:
 
500V rms.  
Between All Elements:
 
1
,
500V rms.  
T
e
rmination: Open Models:
 
Solder terminals.  
Enclosed Models:
 
Octal-type plug.  
Enclosure:
T
r
ansparent polycarbonate.  
Weight: KA:
1
.
7 oz. (48.2g) approximately.  
KRPA, KRP:
 
3.0 oz. (85g) approximately.  
Dimensions are shown for  
reference purposes only.  
Dimensions are in inches over  
(millimeters) unless otherwise  
specified.  
Specifications and availability  
subject to change.  
Technical support:  
Refer to inside back cover.  
737  

Catalog 1308242  
PDF Revised 9-03  
P&B  
Ordering Information  
T
y
pical Part No.
 
B
 
KRPA  
-5  
A
Y
-120  
1. Series:  
KRPA (Newer version, enclosed)  
KRP (Older version, enclosed)  
KA (Open style)  
2. Contact Arrangement:  
5 = 1 Form C (SPDT)  
11 = 2 Form C (DPDT)  
14 = 3 Form C (3PDT)  
3. Coil Input:  
A = AC, 50/60 Hz.  
D = DC  
4. Contact Rating and Indicator Lamp Option:  
TYPE  
KRPA  
KRP  
KA  
Codes  
Available  
Y,
G
, N,  
Y,
G
, N,  
Y,
G
,  
Y = Silver, no indicator lamp  
G = Silve
r
–
cadmium oxide, no indicator lamp  
N = Silve
r
–
cadmium oxide, with indicator lamp*  
5. Coil
V
o
ltage:  
Up to 240VAC  
Up to 125VDC  
*
Indicator Lamp not available on 25-90V coils. Only 120-240VAC and
1
1
0
VDC models are UL recognized and CSA certified.  
Our authorized distributors are more likely to stock the following items for immediate deliver
y
.  
KA-5AG-120  
KA-5
A
Y
–
120  
KA-5DG-6  
KRP-
1
1
AN-24  
KRP-
1
1
AN-120  
KRP-
1
1
A
Y
–
120  
KRP-
1
1
DG-12  
KRP-
1
1
DG-24  
KRP-
1
1
DG-48  
KRP-
1
1
DG-
1
10  
KRP-
1
1
DG-125  
KRP-
1
1
DN-12  
KRP-
1
1
DN-24  
KRP-
1
1
D
Y
–
24  
KRP-14AG-120  
KRP-14AG-240  
KRP-14AN-120  
KRP-14A
Y
–
120  
KRP-14DG-12  
KRP-14DG-24  
KRP-14DG-
1
10  
KRP-14DN-24  
KRPA-5AG-24  
KRPA-
1
1
A
Y
–
240  
KRPA-
1
1
DG-6  
KRPA-14A
Y
–
240  
KRPA-14DG-12  
KRPA-14DG-24  
KRPA-14DG-48  
KRPA-14DG-
1
10  
KRPA-14DN-24  
KRPA-14D
Y
–
24  
KRPA-5AG-120  
KRPA-5A
Y
–
120  
KRPA-5DG-6  
KRPA-5DG-12  
KRPA-5DG-24  
KRPA-5D
Y
–
12  
KRPA-5D
Y
–
24  
KRPA-
1
1
AG-6  
KRPA-
1
1
AG-12  
KRPA-
1
1
AG-24  
KRPA-
1
1
AG-120  
KRPA-
1
1
AG-240  
KRPA-
1
1
AN-12  
KRPA-
1
1
AN-24  
KRPA-
1
1
AN-120  
KRPA-
1
1
AN-240  
KRPA-
1
1
A
Y
–
6  
KRPA-
1
1
DG-12  
KRPA-
1
1
DG-24  
KRPA-
1
1
DG-48  
KRPA-
1
1
DG-
1
10  
KRPA-
1
1
DN-12  
KRPA-
1
1
DN-24  
KRPA-
1
1
DN-
1
10  
KRPA-
1
1
D
Y
–
12  
KRPA-
1
1
D
Y
–
24  
KRPA-14AG-12  
KRPA-14AG-24  
KRPA-14AG-120  
KRPA-14AG-240  
KRPA-14AN-24  
KRPA-14AN-120  
KRPA-14AN-240  
KRPA-14A
Y
–
24  
KRPA-14A
Y
–
120  
KA-5DG-12  
KA-5DG-
1
10  
KA-
1
1
AG-120  
KA-
1
1
A
Y
–
6  
KA-
1
1
A
Y
–
24  
KA-
1
1
A
Y
–
120  
KA-
1
1
DG-12  
KA-
1
1
DG-24  
KA-
1
1
DG-
1
10  
KA-14AG-120  
KA-14A
Y
–
120  
KA-14DG-24  
KA-14DG-
1
10  
KRP-5AG-120  
KRP-
1
1
AG-24  
KRP-
1
1
AG-120  
KRP-
1
1
AG-240  
KRPA-
1
1
A
Y
–
12  
KRPA-
1
1
A
Y
–
24  
KRPA-
1
1
A
Y
–
120  
Dimensions are shown for  
reference purposes only.  
Dimensions are in inches over  
(millimeters) unless otherwise  
specified.  
Specifications and availability  
subject to change.  
Technical support:  
Refer to inside back cover.  
738  

Catalog 1308242  
PDF Revised 9-03  
P&B  
KR
P
–
3-H

series  

20 Amp  
Small AC or DC Relays  
File E22575  
KRP-3-H  
Features  
Coil Data @ 25°C  
• 1 Form X (SPST – NO – DM) contact rating of 20A.  
• Heavy copper alloy movable contact arms.  
•
T
w
in silve
r
–
cadmium oxide contacts.  
• Many uses in automation controls and other applications requiring high  
current switching.  
See chart on page 105.  
Nominal Power:
 
DC Coils:
1
.
2W  
AC Coils:
2.0VA  
Initial Insulation Resistance:
 
1
,
000 megohms.  
Operate Data @ 25°C  
Must-Operate
V
o
ltage:
 
DC:
75% of nominal voltage.  
AC:
85% of nominal voltage.  
Operate Time:
 
15 milliseconds approximate (Excluding Bounce).  
Release Time:
 
10 milliseconds approximate (Excluding Bounce).  
Contact Data @ 25°C  
Arrangement:
1 Form X (SPST – NO – DM).  
Ratings:
UL Rating: 20A @ 120VAC, 3/4 HP @ 120VAC.  
Factory Rating:
 
20A @ 120VAC, 80% PF; 1 HP @  
120/240VAC.  
Material:
T
w
in, silve
r
–
cadmium oxide.  
Expected Life:
 
2.5 million operations min., mechanical. 100,000  
operations at rated contact load.  
Environmental Data  
T
e
mperature Range:
 
Enclosed Models:
 
AC:
-45°C to +55°C.  
DC:
-45°C to +70°C.  
Initial Dielectric Strength  
Between Open Contacts:
 
500V rms, 60 Hz. between all elements.  
Mechanical Data  
Mounting:
Socket mounting.  
T
e
rmination:
Octal-type plug.  
Enclosure:
Polycarbonate enclosure with octal-type mounting.  
Weight:
2 oz. (57g) approximately.  
Ordering Information  
T
y
pical Part No.
 
B  
1. Basic Series:
 
KR  
KR  
P
-3  
D
H
-12  
2. Type:  
P = Enclosed  
(20 amp models available only with Contact Arrangement 3 and Material H.)  
3. Contact Arrangement:  
3 = 1 Form X (SPST – NO – DM)  
4. Coil Input:  
A = AC  
D = DC  
5. Contact Material & Rating:  
H = Silve
r
–
cadmium oxide, 1/4″ (6.35mm) dia., 20 amps.  
6. Coil
V
o
ltage:  
To
2
40VAC, 50/60 Hz. or
1
1
0
VDC.  
Our authorized distributors are more likely to stock the following items for immediate deliver
y
.  
KRP-3AH-120  
KRP-3DH-24  
KRP-5AG-120  
Dimensions are shown for  
reference purposes only.  
Dimensions are in inches over  
(millimeters) unless otherwise  
specified.  
Specifications and availability  
subject to change.  
Technical support:  
Refer to inside back cover.  
739  

Catalog 1308242  
PDF Revised 9-03  
P&B  
Outline Dimensions  
KA Series  
1
.
468 MAX.  
(3
7
.
29)  
1
.
06 MAX.  
(26.9)  
.44  
(
1
1
.
2)  
1 STUD  
#6-32  
THREAD  
.25  
(6.4)  
.15  
(3.8)  
1
.
92 MAX.  
(48.8)  
.312  
(
7
.
92)  
T
o
lerances on .XX Decimals
 
.02 (
 
.5) Unless Otherwise Specified  
T
o
lerances on .XXX Decimals
 
.005 (
 
.
13) Unless Otherwise Specified  
KR Series Enclosures  
T
y
pe “P” Clear Dust Cover  
For KRPA and KRP  
For KRP3-H  
1
.
406 MAX.  
(35.71)  
1
.
531 MAX.  
(38.89)  
.031  
(.79)  
Hold-Down Spring  
20C176 KRPA & KRP  
20C206 KAP and KRP3  
Durable stainless steel  
spring can be moved  
aside for relay removal or  
installation. Mounts with  
same machine screws or  
rivets that secure socket  
to chassis.
T
w
o .156″  
(3.96mm) dia. holes  
required.  
Wiring Diagrams (Bottom Views)  
KA  
KAP
1
1  
KRP
1
1  
KRPA11  
KAP14  
KRP14  
KRPA14  
KRP3AH  
KR5  
KAP5  
KRP5  
KRPA5  
8
5
8
5
1
4
1
11  
1
8
5
1
10  
2
7
6
2
7
6
2
7
6
2
3
9
3
4
3
3
8
5
7
4
4
6
Dimensions are shown for  
reference purposes only.  
Dimensions are in inches over  
(millimeters) unless otherwise  
specified.  
Specifications and availability  
subject to change.  
Technical support:  
Refer to inside back cover.  
740  

Catalog 1308242  
PDF Revised 9-03  
P&B  
Sockets For KR
P
,
K
RPA Series Relays  
The following sockets are normally maintained in stock for immediate delivery.  
Screw
T
e
rminal, DIN Rail Snap-Mount Sockets  
(Use with mounting track 24A
1
10)  
27E891  
10A, 300
V
AC  
T
e
rminal  
Location  
T
e
rminal  
Location  
27E892  
10A, 300
V
AC  
T
o
p View  
T
o
p View  
1
.
295  
(32.89)  
2.060  
(52.32)  
2
1
8
7
1
11  
1
.
005  
(25.53)  
2
10  
1
.
018  
(25.84)  
3
9
2.010  
(5
1
.
05)  
2.035  
(5
1
.
69)  
.165  
(4
.
19)  
DIA.TY
P
.  
.165  
(4
.
19)  
DIA.TYP  
4
8
7
5
4
5
3
6
6
.31
2
T
Y
P
.  
(
7
.
92)  
.580  
(14.73)  
.31
2
T
Y
P
.  
(
7
.
92)  
.580  
(14.73)  
2.332  
(59.22)  
.770  
(19.56)  
1
.
575  
(40.01)  
.970  
(24.64)  
.970  
(24.64)  
Sockets have M3.5 screw terminals which accept up to two #12 AWG  
wires. Rated 10 amps @ 300VAC and meets UL 94V-0.  
Screw
T
e
rminal Sockets  
27E123  
27E122  
10A, 300
V
AC  
11-pin  
10A, 300
V
AC  
8-pin  
1
.
296  
(32.92)  
2.060  
(52.32)  
.648  
1
.
030  
.062  
(16.46)  
(26
.
16)  
(
1
.
57)  
1
.
296  
(32.92)  
.156 DIA
.
T
Y
P
.  
(3.96)  
.648  
(16.46)  
2.385 MAX.  
(60.58)  
.062  
(
1
.
57)  
1.1
8
8  
(30
.
18)  
2.385 MAX.  
(60.58)  
.093  
(2.36)  
+
+
¢
.21
0
T
Y
P
.  
(5.33)  
.781  
(19.84)  
1.1
8
8  
(30
.
18)  
1
.
572 MAX.  
(39.93)  
= 6-32 SCREWS &  
CAPTIVE WASHERS  
¢
1.1
5
6  
(29.36)  
.21
0
T
Y
P
.  
(5.33)  
.093  
(2.36)  
2.322 MAX.  
(58.98)  
= 6-32 SCREWS &  
CAPTIVE WASHERS  
.925 MAX.  
(23.50)  
¢
.925 MAX.  
(23.50)  
T
e
rminal  
Location  
6
5
4
3
8
7
6
5
4
T
e
rminal  
Location  
7
8
1
2
9
10 11  
1
2
3
Dimensions are shown for  
reference purposes only.  
Dimensions are in inches over  
(millimeters) unless otherwise  
specified.  
Specifications and availability  
subject to change.  
Technical support:  
Refer to inside back cover.  
741