TE-Connectivity-PRD-7AY0-208
| Part # | TE-Connectivity-PRD-7AY0-208 |
| Download | TE-Connectivity-PRD-7AY0-208 |
General Purpose
Panel/Plug-in Relays
Potter & Brumfield
PRD Series Power Relay
n
n
n
n
n
Contact ratings to 50A
Magnetic blowouts available for switching DC loads
Contact arrangement up to 2 form C (2CO)
1 form C auxiliary switch available
UL class B insulation
Typical applications
Industrial controls, lighting.
Approvals
Contact ratings
(continued)
UL E22575; CSA LR15734;
T
y
pe
Load
Cycles
UL 508
1)
Models with all screw terminals are UL Listed. Others are UL Recognized.
T
e
chnical data of approved types on request.
Models with screws or quick connects for main terminals
Code
F
,
A
gCdO, 1 pole
50A, 240VAC, general purpose
2)
30A, 277VAC, resistive
1.5H
P
,
1
20VAC
2H
P
,
2
50VAC
10A, 600VAC
Code
F
,
A
gCdO, 2 pole
50A, 240VAC, general purpose
2)
30A, 240VAC
20×10
3
100×10
3
100×10
3
100×10
3
100×10
3
Contact Data
Contact arrangement
1 and 2 form A (NO); 1 and 2 form C (CO);
1 form X (NO-DM)
600VAC,125VDC
50A
Ag, AgCdO, W
1A, 12VDC or 12VAC
75mΩ max.
75mV
Rated voltage
Rated current
Contact material
Min. recommended contact load
Initial contact resistance
Initial voltage drop
Frequency of operation
Operate/releases time max.
Bounce time max.
20×10
3
100×10
3
100×10
3
100×10
3
100×10
3
100×10
3
20A, 277VAC
1.5H
P
,
1
20VAC
2H
P
,
2
50VAC
10A, 600VAC
7200 ops/hr
40/20ms
10ms
2) In order to achieve 50A rating with contact code
F
,
t
ermination Code 0 or A is required.
Contact ratings
Code H, Ag with magnetic blowout, 1 or 2 pole
T
y
pe
Load
Cycles
20A, 125VDC
1/3H
P
,
1
25VDC
Code J, AgCdO with magnetic blowout, 1 or 2 pole
20A, 125VDC
1/3H
P
,
1
25VDC
Code N, W stationary with AgCdO movable, 1 or 2 pole
25A, 250VAC
100×10
3
100×10
3
UL 508
1)
Models with screws or quick connects for main terminals
Code
Y
,
A
g, 1 pole
25A, 277VAC
100×10
3
100×10
3
100×10
3
100×10
3
100×10
3
100×10
3
100×10
3
1H
P
,
1
20VAC
2H
P
,
2
50VAC
10A, 600VAC
100×10
3
100×10
3
100×10
3
1H
P
,
1
25VAC
7A, 50VDC, resistive
Code
Y
,
A
g, 2 pole
25A, 240VAC
2H
P
,
2
50VAC
UL 508
1)
100×10
3
100×10
3
100×10
3
100×10
3
100×10
3
100×10
3
Models with box lugs for main terminals
Code
P
,
A
g, 1 form X
20A, 277VAC
1H
P
,
1
20VAC
2H
P
,
2
50VAC
7A, 50VDC, resistive
10A, 600VAC
50A, 277VAC, general purpose
30A, 277VAC, ballast
15A, 277VAC, tungsten
102LRA, 17FLA, 240VAC
120LRA, 20FLA, 120VAC
1.5H
P
,
1
20VAC
100×10
3
6×10
3
6×10
3
30×10
3
30×10
3
30×10
3
30×10
3
Code G, AgCdO, 1 pole
30A, 277VAC, resistive
1.5H
P
,
1
20VAC
100×10
3
100×10
3
100×10
3
100×10
3
3H
P
,
2
40VAC
2H
P
,
2
50VAC
10A, 600VAC
Factory ratings
Models with box lugs for main terminals
Code R, Ag with magnetic blowout, 1 form X
60A, 28VDC, resistive
Code G, AgCdO, 2 pole
30A, 240VAC
100×10
3
100×10
3
100×10
3
100×10
3
100×10
3
100×10
3
100×10
3
20A, 277VAC
1.5H
P
,
1
20VAC
2H
P
,
2
50VAC
10A, 600VAC
30A, 125VDC
Mechanical endurance
DC Coil, 1×10
6
ops.; AC Coil 5×10
5
ops.
1) Any
PRD relay deviating electrically or physically from the standard models in the table is
not UL or CSA listed. All horsepower ratings are for single phase motors..
Auxiliary Snap-Action Switch Contact Data
Contact arrangement
Rating
1 form C (CO)
5A, 120VAC, 60Hz., 25°C
Ag
Contact material
1
11-2020, Rev. 1120
Catalog and product specification according
to IEC 61810-1 and to be used only together
with the ‘Definitions’ section.
Catalog and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
Catalog product data, ‘Definitions’ section,
application notes and all specifications are
subject to change.
© 2015 Tyco Electronics Corporation,
a TE Connectivity Ltd. company.
General Purpose
Panel/Plug-in Relays
Potter & Brumfield
PRD Series Power Relay
(Continued)
Coil Data
Insulation Data
Coil voltage range
6 to 110VDC
6 to 480VAC
Class B
Initial dielectric strength
between open contacts
between contact and coil
between adjacent contacts
Initial insulation resistance
between insulated elements
2000V
rms
2000V
rms
2000V
rms
Coil insulation system according UL
Coil versions, DC coil
Coil
code
Rated
voltage
VDC
6
12
24
Operate
voltage
VDC
4.5
9
18
Release
voltage
VDC
0.6
1.2
2.4
Coil
resistance
Ω 10ꢀ
18
71
288
1150
6050
Rated coil
power
100MΩ
W
2
2
2
2
6
Other Data
12
24
48
110
Material compliance: EU RoHS/E
L
V,
C
hina RoHS, REACH, Halogen content
refer to the Product Compliance Support Center at
Ambient temperature
48
110
36
82.5
4.8
11
2
All figures are given for coil without preenergization, at ambient temperature +23°C.
Other coil voltages on request.
AC coil: -55ºC to 45ºC
DC coil: -55°C to 80°C
Category of environmental protection
Coil versions, AC coil
IEC 61810
T
e
rminal type
Weight
RT0 – open relay
Screw, Quick connects, Box lugs
284g
Coil
Rated
voltage
VAC
6
Operate
voltage
VAC
Release
voltage
VAC
0.6
Coil
resistance
Ω 15ꢀ
0.86
Rated coil
power
VA
code
Packaging/unit
tray/20 pcs., box/40pcs.
6
5.1
9.8
12
24
120
240
480
12
24
120
240
480
10.2
20.4
102
204
408
1.2
2.4
12
24
3.2
12
290
1200
4500
9.8
9.8
9.8
9.8
Accessories
Product Code
Description
35D013
Metal dust cover
48
9.8
All figures are given for coil without preenergization, at ambient temperature +23°C.
Other coil voltages on request.
Dimensions
PRD/PRDA 1, 3, 5 and 7
PRD/PRDA 11
PRD-3_P and R
2 MTG. HOLES
DIA.
.187 + .005
– .003
2.5 MAX.
.875 MAX.
(22.23)
.875 MAX.
(22.23)
.31
(7.9)
3.375 MAX.
(85.73)
.31
(7.9)
.31
(7.9)
(63.3)
1.687
(42.85)
.81
(20.6)
4.75 + .13
(
)
– .08
4
3
2
COIL
1
4
3
2
2
6
5
6
5
6
5
8
7
2.51 MAX.
2.50
2.51 MAX.
(63.75)
(63.8)
(63.5)
COIL
1
BOX LUG
CONNECTOR
1.875
COIL
1.875
(47.63)
1.875
(47.63)
(47.63)
1
2 MTG. HOLES
DIA.
.81
(20.6)
2 MTG. HOLES
DIA.
.187 + .005
– .003
.59 MAX.
(15.0)
2.5 MAX.
(64)
.187 + .005
– .003
4.75 + .13
(
)
4.75 + .13
– .08
(
)
– .08
2.28 MAX.
(57.9)
2.50 MAX.
(63.5)
2.28 MAX.
(57.9)
2.50 MAX
.
O
N PRD7
(63.5)
.375
(9.53)
2.23
3.00
(56.6)
(76.2)
.375
(9.53)
.375
(9.53)
3.375
(85.73)
4.250 MAX.
(107.95)
3.375 MAX.
(85.73)
2.5 MAX.
(63.5)
W/O AUX SWITCH
W/O AUX SWITCH
2
11-2020, Rev. 1120
© 2015 Tyco Electronics Corporation,
a TE Connectivity Ltd. company.
Catalog and product specification according
to IEC 61810-1 and to be used only together
with the ‘Definitions’ section.
Catalog and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
Catalog product data, ‘Definitions’ section,
application notes and all specifications are
subject to change.
General Purpose
Panel/Plug-in Relays
Potter & Brumfield
PRD Series Power Relay
(Continued)
T
e
rminal assignment for models with magnetic blowout
PRD3 with blowout
PRD7 with blowout
PRD 11 with blowout
THIS SIDE OF MAGNET
ATTRACTS NORTH SEEKING
POLE OF COMPASS.
THIS SIDE OF MAGNET
ATTRACTS NORTH SEEKING
POLE OF COMPASS.
THIS SIDE OF MAGNET
ATTRACTS NORTH SEEKING
POLE OF COMPASS.
–
–
+
+
–
–
POLARITY
MARKING
POLARITY
MARKING
POLARITY
MARKING
Product code structure
T
y
pical product code
PRD
-7
A
Y
0
-120
T
y
pe
PRD
Open relay
PRDA
Open relay with aux. 1 form C (CO) snap-action switch
Main contact arrangement
1 form A (1 NO)
1 form C (1 CO)
7V
2 form A (2 NO) with 3mm contact gap
1)
1
5
3
7
1 form X (1 NO-DM)
2 form A (2 NO)
11
2 form C (2 CO)
1) Code 7V is only available as a UL Recognized model, not UL Listed
Coil input
A
AC, 50/60Hz
D
DC
Main contact material and type
Y
G
F
H
J
N
P
R
.312” (7.92mm) dia. Ag [25A max. rating]
.312” (7.92mm) dia. AgCdO [30A max. rating]
.312” (7.92mm) dia. AgCdO [50A max. rating]
Ag with magnetic blowout
[20A DC max. rating]
AgCdO with magnetic blowout
[20A DC max. rating]
2)
3)
4)
W stationary & AgCdO movable
[25A max. rating]
5)
Ag [50A max.
rating]
5)
Ag with magnetic blow out
[50A max. rating]
2) Available with Main contact arrangement code 1, 5, 7 or 11 only, and
T
e
rmination code 0 or A only.
3) Available with Main contact arrangement code 3, 7 or 11 only
4) Available with Main contact arrangement code 1, 5, 7 or 11 only.
5) Available with Main contact arrangement code 3 only, and
T
e
rmination code 4 only.
T
e
rmination
PRD types only
0
1
3
4
#8-32 screw term. for main contacts, #6-32 screw term. for coil.
.250” (6.35mm) QC for main contacts and coil
#8-32 screw term. for main contacts, .250” (6.35mm) QC for coil.
Box lug term. which accept #6 – #14 wire for main contacts, #6-32 screw term. for coil.
6)
6) Available with Main contact arrangement code 3 only, and Main contact material code P or R only.
PRDA (with aux. switch) types only
A
B
L
#8-32 screw term. for main contacts, #6-32 screw term. for coil, screw term. for aux. switch
.250” (6.35mm) QC for main contacts, coil and aux. switch
T
w
in .250” (6.35mm) QC for main contacts, .250” (6.35mm) QC for coil and aux. switch
Coil voltage
Coil code: please refer to coil versions table
3
11-2020, Rev. 1120
Catalog and product specification according
to IEC 61810-1 and to be used only together
with the ‘Definitions’ section.
Catalog and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
Catalog product data, ‘Definitions’ section,
application notes and all specifications are
subject to change.
© 2015 Tyco Electronics Corporation,
a TE Connectivity Ltd. company.
General Purpose
Panel/Plug-in Relays
Potter & Brumfield
PRD Series Power Relay
(Continued)
Product Code
PRD-3AY0-120
PRD-3AG0-120
PRD-3AJ0-120
PRD-3AJ3-24
PRD-3DH0-24
PRD-3DY0-12
PRD-3DY0-24
PRD-3DY0-110
PRD-5AY0-24
PRD-5AY0-120
PRD-5AY1-120
PRD-5AY0-240
PRD-5DF0-12
PRD-5DY0-12
PRD-5DY0-24
PRD-7AG0-120
PRD-7AY0-24
Arrangement
Material
Ag
AgCdO, 30A
AgCdO, mag blowout
Coil
T
e
rminals
Part Number
7-1393127-9
6-1393127-9
7-1393127-4
7-1393127-5
8-1393127-6
9-1393127-5
9-1393127-6
9-1393127-4
1393128-6
1393128-5
1-1393128-1
1393128-7
2-1423100-4
1-1393128-6
1-1393128-7
9-1393129-5
1393130-9
1 form X, 1 NO-DM
120VAC
Screw
24VAC
24VDC
12VDC
24VDC
110VDC
24VAC
120VAC
Screw / QC
Screw
Ag, mag blowout
Ag
1 form C, 1 CO
QC
Screw
240VAC
12VDC
AgCdO, 50A
Ag
24VDC
120VAC
24VAC
2 form A, 2 NO
AgCdO, 30A
Ag
PRD-7AY0-120
PRD-7AY0-240
PRD-7AY3-120
PRD-7DG0-24
PRD-7DH0-48
PRD-7DY0-12
PRD-7DY0-24
PRD-11AF0-240
PRD-11AG0-24
PRD-11AG0-120
PRD-11AG0-240
PRD-11AH0-120
PRD-11AY0-24
PRD-11AY0-120
PRD-11AY0-240
PRD-11AY0-480
PRD-11DF0-12
PRD-11DF0-110
PRD-11DG0-12
PRD-11DG0-24
PRD-11DH0-12
PRD-11DH0-24
PRD-11DH0-48
PRD-11DH0-110
PRD-11DJ0-24
PRD-11DY0-12
PRD-11DY0-24
PRD-11DY0-48
PRD-11DY0-110
PRDA-11AGA-120
PRDA-11AYA-120
120VAC
240VAC
120VAC
24VDC
48VAC
12VDC
24VDC
240VAC
24VAC
120VAC
240VAC
120VAC
24VAC
120VAC
240VAC
480VAC
12VDC
110VDC
12VDC
24VDC
12VDC
24VDC
48VDC
110 VDC
24 VDC
12 VDC
24 VDC
48 VAC
110 VDC
120 VAC
1393130-7
1-1393130-0
1-1393130-2
1-1393130-6
2-1393130-1
2-1393130-8
2-1393130-9
3-1423100-0
1-1393127-1
1393127-9
1-1393127-2
1-1393127-6
2-1393127-9
2-1393127-6
3-1393127-0
3-1393127-1
2-1423100-2
2-1423100-9
3-1393127-5
3-1393127-8
4-1393127-7
4-1393127-9
5-1393127-0
4-1393127-6
5-1393127-5
6-1393127-1
6-1393127-2
6-1393127-3
6-1393127-0
7-1393131-4
7-1393131-9
Screw / QC
Screw
AgCdO, 30A
Ag, mag blowout
Ag
2 form C, 2 CO
AgCdO, 50A
AgCdO, 30A
Ag, mag blowout
Ag
AgCdO, 50A
AgCdO, 30A
Ag, mag blowout
AgCdO, mag blowout
Ag
AgCdO, 30A
PRD accessory
Product Code
35D013
Description
Metal dust cover enclosure
Part Number
5-1393158-2
5.31 MAX.
(134.9)
3.13 MAX.
(79.5)
.97
(24.64)
35D013 Dust Cover
4.125
(104.77)
PRD dust cover has a steel base
with knockouts for 0.5” (12.7mm) dia.
conduit and a cover fitted with two
screws. Fits PRD relays, except with
auxiliary contacts. Finished in gray
baked enamel.
.687
(17.45)
.50
2.06
.093
(12.7)
(52.3)
(2.36)
1.50
(38.1)
1.875
(47.63)
1.625
(41.28)
3.38 MAX.
(85.9)
.75
(19.1)
Mounting:
.812
.937
Three No. 10 holes on
1.875” (47.63mm) x
4.125” (104.77mm)
(20.62)
(23.86)
2.56
(65.0)
.88 DIA.
(22.4)
.218 DIA.
(5.54)
3 MTG. HOLES
5.125
(130.18)
4
KNOCKOUT HOLES
centers.
4 HOLES TAPPED #8-32
Note: Additional unused holes may be present in dust cover base.
2 KNOCKOUT HOLES EACH END
4
11-2020, Rev. 1120
Catalog and product specification according
to IEC 61810-1 and to be used only together
with the ‘Definitions’ section.
Catalog and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
Catalog product data, ‘Definitions’ section,
application notes and all specifications are
subject to change.
© 2015 Tyco Electronics Corporation,
a TE Connectivity Ltd. company.