TE-Connectivity-SR4M4018
| Part # | TE-Connectivity-SR4M4018 |
| Download | TE-Connectivity-SR4M4018 |
General Purpose Relays
Force Guided Relays
SCHRACK
Force Guided Relay SR4 D/M
n
n
4 pole relay with force guided contacts according to EN EN61810-3
(formerly EN50205)
Compact design and space efficient
Typical applications
Emergency shut-off, press control, machine control, elevator and escalator
control, safety relays
F0244-C
Z
Approvals
Coil data
VDE Cert. No. 40005334, UL E214025, TUV 968/EL 230,
CCC 2020970303000303
Coil voltage range
5 to 110VDC
T
e
chnical data of approved types on request
Coil versions, DC-coil
Coil
code
Rated
voltage
VDC
5
6
9
12
15
18
21
24
36
40
48
60
85
110
Operate
voltage
VDC
3.8
4.5
6.8
Release
voltage
VDC
0.5
0.6
0.9
1.2
1.5
1.8
2.1
2.4
3.6
4.0
4.8
6.0
8.5
11.0
Coil
resistance
Ω 10ꢀ
31
Rated coil
power
mW
806
Contact Data
Contact arrangement
3 form A + 1 form B contacts
3 NO + 1 NC
2 form A + 2 form B contacts
2 NO + 2 NC
005
006
009
012
015
018
021
024
036
040
048
060
085
110
45
101
180
281
405
551
720
1620
2000
2880
4500
9031
15125
800
802
800
801
800
800
800
800
800
800
800
800
Rated voltage
Max. switching voltage
Rated current
Contact material
Contact style
250VAC
400VAC
8A
AgSnO
2
9.0
11.3
13.5
16.0
18.0
27.0
30.0
36.0
45.0
63.8
83.0
single contact, force guided
type A according to EN61810-3
(formerly EN50205)
5V/10mA
Min. recommended contact load
Initial contact resistance
≤100mΩ at 1A, 24VDC
≤20Ω at 10mA, 5VDC
Frequency of operation, with/without load
Contact ratings
6/150min
-1
800
All figures are given for coil without pre-energization, at ambient temperature +23°C.
T
y
pe
Contact
Load
Cycles
IEC 61810
SR4
SR4
1xA (NO)
1xB (NC)
8A, 250VAC, cos
φ
=1, 70°C
5A, 250VAC, cos
φ
=1, 70°C
20×10
3
20×10
3
UL 508
SR4
A/B (NO/NC)
8A, 250VAC, general purpose, 70°C
6.000
SR4
SR4
1xA (1xNO)
R300, B300
1xB (1xNC)
R300
6.000
6.000
EN60947-5-1
SR4
SR4
1xA/1xB (1xNO/1xNC)
3A, 24VDC, DC13
6.050
6.050
1xA (1xNO)
3A, 250VAC AC-15
More ratings and information see product specification 2158002
Mechanical endurance
10×10
6
operations
1
10-2020, Rev. 1020
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
© 2015 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
General Purpose Relays
Force Guided Relays
SCHRACK
Force Guided Relay SR4 D/M
(Continued)
Insulation Data
PCB layout / terminal assignment
Bottom view on solder pins
Initial dielectric strength
between open contacts
between contact and coil
between adjacent contacts
Clearance/creepage
1500Vrms
4000Vrms
2500Vrms
between open contacts
between contact and coil
between adjacent contacts
microdisconnection
≥10/10mm
≥3/3.5mm
Insulation to EN 50178, type of insulation
between contact and coil
between adjacent contacts
reinforced
basic
S0413-BC
Other Data
2 form A + 2 form B, 2 NO + 2 NC contacts
Material compliance: EU RoHS/E
L
V,
C
hina RoHS, REACH, Halogen content
refer to the Product Compliance Support Center at
Ambient temperature
Category of environmental Protection
IEC 61 810
-25 to 70°C
RTIII
30g
Weight
S0413-BB
Resistance to soldering heat THT
IEC 60068-2-20
Packaging/unit
260°C/5s
tube/10 pcs.
3 form A + 1 form B, 3 NO + 1 NC contacts
For more detailed information see product specification 2158002
Dimensions
S0413-BA
S0412-BH
Product code structure
T
y
pe
T
y
pical product code
SR4
D
4
012
SR4
Relay with force guided contacts SR4
Contact arrangement
D
M
2 form A + 2 form B contacts (2 NO + 2 NC)
3 form A + 1 form B contacts (3 NO + 1 NC)
Contact material
AgSnO
2
4
Coil
Coil code: please refer to coil versions table (e.g. 012=12VDC)
Other types on request
2
10-2020, Rev. 1020
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
© 2015 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
General Purpose Relays
Force Guided Relays
SCHRACK
Force Guided Relay SR4 D/M
(Continued)
Product code
SR4D4005
SR4D4006
SR4D4009
SR4D4012
SR4D4018
SR4D4021
SR4D4024
SR4D4036
SR4D4040
SR4D4048
SR4D4060
SR4D4085
SR4D4110
SR4M4005
SR4M4006
SR4M4009
SR4M4012
SR4M4018
SR4M4021
SR4M4024
SR4M4036
SR4M4040
SR4M4048
SR4M4060
SR4M4085
SR4M4110
T
y
pe
4 pole
Contact arrangement
Contact material
Coil
5VDC
Part number
7-1415054-1
8-1415054-1
9-1415054-1
1415055-1
2 form A + 2 form B,
2 NO + 2 NC
contacts
AgSnO
2
relay with
6VDC
force guided contacts
9VDC
12VDC
18VDC
21VDC
24VDC
36VDC
40VDC
48VDC
60VDC
85VDC
110VDC
5VDC
1-1415055-1
2-1415055-1
3-1415055-1
4-1415055-1
5-1415055-1
6-1415055-1
7-1415055-1
8-1415055-1
9-1415055-1
5-1415053-1
6-1415053-1
7-1415053-1
8-1415053-1
9-1415053-1
1415054-1
4-1415053-1
1-1415054-1
2-1415054-1
3-1415054-1
4-1415054-1
5-1415054-1
6-1415054-1
3 form A + 1 form B,
3 NO + 1 NC
contacts
6VDC
9VDC
12VDC
18VDC
21VDC
24VDC
36VDC
40VDC
48VDC
60VDC
85VDC
110VDC
3
10-2020, Rev. 1020
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
© 2015 Tyco Electronics Corporation,
a TE Connectivity Ltd. company