TE-Connectivity-SR4M4018

Part #TE-Connectivity-SR4M4018
Download 
TE-Connectivity-SR4M4018
General Purpose Relays  
Force Guided Relays  
SCHRACK  
Force Guided Relay SR4 D/M  
n
n
4 pole relay with force guided contacts according to EN EN61810-3  
(formerly EN50205)  
Compact design and space efficient  
Typical applications  
Emergency shut-off, press control, machine control, elevator and escalator  
control, safety relays  
F0244-C  
Z
Approvals  
Coil data  
VDE Cert. No. 40005334, UL E214025, TUV 968/EL 230,  
CCC 2020970303000303  
Coil voltage range  
5 to 110VDC  
T
e
chnical data of approved types on request  
Coil versions, DC-coil  
Coil  
code  
Rated  
voltage  
VDC  
5
6
9
12  
15  
18  
21  
24  
36  
40  
48  
60  
85  
110  
Operate  
voltage  
VDC  
3.8  
4.5  
6.8  
Release  
voltage  
VDC  
0.5  
0.6  
0.9  
1.2  
1.5  
1.8  
2.1  
2.4  
3.6  
4.0  
4.8  
6.0  
8.5  
11.0  
Coil  
resistance  
Ω 10ꢀ  
31  
Rated coil  
power  
mW  
806  
Contact Data  
Contact arrangement  
3 form A + 1 form B contacts  
3 NO + 1 NC  
2 form A + 2 form B contacts  
2 NO + 2 NC  
005  
006  
009  
012  
015  
018  
021  
024  
036  
040  
048  
060  
085  
110  
45  
101  
180  
281  
405  
551  
720  
1620  
2000  
2880  
4500  
9031  
15125  
800  
802  
800  
801  
800  
800  
800  
800  
800  
800  
800  
800  
Rated voltage  
Max. switching voltage  
Rated current  
Contact material  
Contact style  
250VAC  
400VAC  
8A  
AgSnO

2  

9.0  
11.3  
13.5  
16.0  
18.0  
27.0  
30.0  
36.0  
45.0  
63.8  
83.0  
single contact, force guided  
type A according to EN61810-3  
(formerly EN50205)  
5V/10mA  
Min. recommended contact load  
Initial contact resistance  
≤100mΩ at 1A, 24VDC  
≤20Ω at 10mA, 5VDC  
Frequency of operation, with/without load  
Contact ratings  
6/150min

-1  

800  
All figures are given for coil without pre-energization, at ambient temperature +23°C.  
T
y
pe  
Contact  
Load  
Cycles  
IEC 61810  
SR4  
SR4  
1xA (NO)  
1xB (NC)  
8A, 250VAC, cos
φ
=1, 70°C  
5A, 250VAC, cos
φ
=1, 70°C  
20×10

3  

20×10

3  

UL 508  
SR4  
A/B (NO/NC)
 
8A, 250VAC, general purpose, 70°C
 
6.000  
SR4  
SR4  
1xA (1xNO)
 
R300, B300  
1xB (1xNC)
 
R300  
6.000  
6.000  
EN60947-5-1  
SR4  
SR4  
1xA/1xB (1xNO/1xNC)
 
3A, 24VDC, DC13  
6.050  
6.050  
1xA (1xNO)  
3A, 250VAC AC-15  
More ratings and information see product specification 2158002  
Mechanical endurance  
10×10

6

operations  
1
10-2020, Rev. 1020  
Datasheets and product specification  
according to IEC 61810-1 and to be used  
only together with the ‘Definitions’ section.  
Datasheets and product data is subject to the  
terms of the disclaimer and all chapters of  
the ‘Definitions’ section, available at  
Datasheets, product data, ‘Definitions’ sec-  
tion, application notes and all specifications  
are subject to change.  
© 2015 Tyco Electronics Corporation,  
a TE Connectivity Ltd. company  

General Purpose Relays  
Force Guided Relays  
SCHRACK  
Force Guided Relay SR4 D/M
(Continued)  
Insulation Data  
PCB layout / terminal assignment  
Bottom view on solder pins  
Initial dielectric strength  
between open contacts  
between contact and coil  
between adjacent contacts  
Clearance/creepage  
1500Vrms  
4000Vrms  
2500Vrms  
between open contacts  
between contact and coil  
between adjacent contacts  
microdisconnection  
≥10/10mm  
≥3/3.5mm  
Insulation to EN 50178, type of insulation  
between contact and coil  
between adjacent contacts  
reinforced  
basic  
S0413-BC  
Other Data  
2 form A + 2 form B, 2 NO + 2 NC contacts  
Material compliance: EU RoHS/E
L
V,
C
hina RoHS, REACH, Halogen content  
refer to the Product Compliance Support Center at  
Ambient temperature  
Category of environmental Protection  
IEC 61 810  
-25 to 70°C  
RTIII  
30g  
Weight  
S0413-BB  
Resistance to soldering heat THT  
IEC 60068-2-20  
Packaging/unit  
260°C/5s  
tube/10 pcs.  
3 form A + 1 form B, 3 NO + 1 NC contacts  
For more detailed information see product specification 2158002  
Dimensions  
S0413-BA  
S0412-BH  
Product code structure  
T
y
pe  
T
y
pical product code
 
SR4  
D
4
012  
SR4
Relay with force guided contacts SR4  
Contact arrangement  
D
M
2 form A + 2 form B contacts (2 NO + 2 NC)  
3 form A + 1 form B contacts (3 NO + 1 NC)  
Contact material  
AgSnO

2  

4
Coil  
Coil code: please refer to coil versions table (e.g. 012=12VDC)  
Other types on request  
2
10-2020, Rev. 1020  
Datasheets and product specification  
according to IEC 61810-1 and to be used  
only together with the ‘Definitions’ section.  
Datasheets and product data is subject to the  
terms of the disclaimer and all chapters of  
the ‘Definitions’ section, available at  
Datasheets, product data, ‘Definitions’ sec-  
tion, application notes and all specifications  
are subject to change.  
© 2015 Tyco Electronics Corporation,  
a TE Connectivity Ltd. company  

General Purpose Relays  
Force Guided Relays  
SCHRACK  
Force Guided Relay SR4 D/M
(Continued)  
Product code  
SR4D4005  
SR4D4006  
SR4D4009  
SR4D4012  
SR4D4018  
SR4D4021  
SR4D4024  
SR4D4036  
SR4D4040  
SR4D4048  
SR4D4060  
SR4D4085  
SR4D4110  
SR4M4005  
SR4M4006  
SR4M4009  
SR4M4012  
SR4M4018  
SR4M4021  
SR4M4024  
SR4M4036  
SR4M4040  
SR4M4048  
SR4M4060  
SR4M4085  
SR4M4110  
T
y
pe  
4 pole  
Contact arrangement
 
Contact material  
Coil  
5VDC  
Part number  
7-1415054-1  
8-1415054-1  
9-1415054-1  
1415055-1  
2 form A + 2 form B,  
2 NO + 2 NC  
contacts  
AgSnO

2  

relay with  
6VDC  
force guided contacts  
9VDC  
12VDC  
18VDC  
21VDC  
24VDC  
36VDC  
40VDC  
48VDC  
60VDC  
85VDC  
110VDC  
5VDC  
1-1415055-1  
2-1415055-1  
3-1415055-1  
4-1415055-1  
5-1415055-1  
6-1415055-1  
7-1415055-1  
8-1415055-1  
9-1415055-1  
5-1415053-1  
6-1415053-1  
7-1415053-1  
8-1415053-1  
9-1415053-1  
1415054-1  
4-1415053-1  
1-1415054-1  
2-1415054-1  
3-1415054-1  
4-1415054-1  
5-1415054-1  
6-1415054-1  
3 form A + 1 form B,  
3 NO + 1 NC  
contacts  
6VDC  
9VDC  
12VDC  
18VDC  
21VDC  
24VDC  
36VDC  
40VDC  
48VDC  
60VDC  
85VDC  
110VDC  
3
10-2020, Rev. 1020  
Datasheets and product specification  
according to IEC 61810-1 and to be used  
only together with the ‘Definitions’ section.  
Datasheets and product data is subject to the  
terms of the disclaimer and all chapters of  
the ‘Definitions’ section, available at  
Datasheets, product data, ‘Definitions’ sec-  
tion, application notes and all specifications  
are subject to change.  
© 2015 Tyco Electronics Corporation,  
a TE Connectivity Ltd. company