WEIDMULLER-2576230000
| Part # | WEIDMULLER-2576230000 |
| Download | WEIDMULLER-2576230000 |
Data sheet
Weidmüller Interface GmbH & Co. KG
Klingenbergstraße 16
D-32758 Detmold
D-SERIES DRI
DRIKITP 24VAC 2CO LD/PB
Germany
Fon: +49 5231 14-0
Fax: +49 5231 14-292083
Product image
Similar to illustration
Our relay kits are particularly convenient to use. The kits
are delivered fully assembled and 100 % function-tested.
This saves assembly time and reduces the number of
parts required.
• Assembled kit consisting of relay, base and retaining
clip, incl. label
• 100% function-tested
• 100% control of the dielectric strength input – output
• Optional: test button with coloured control voltage
marking (AC coil: red / DC coil: blue) and mechanical
switch position indicator
• Bright status LED (AC coil: red / DC coil: green)
General ordering data
Type
DRIKITP 24VAC 2CO LD/PB
Order No.
Version
D-SERIES DRI, Relay module, No. of contacts: 2
CO contact with test button AgNi, Rated control
voltage: 24 V AC, Continuous current: 5 A, PUSH
IN with actuator
GTIN (EAN)
Qty.
4050118585995
10 pc(s).
Creation date January 18, 2019 5:44:15 PM CET
Catalogue status 04.01.2019 / We reserve the right to make technical changes.
1
Data sheet
Weidmüller Interface GmbH & Co. KG
Klingenbergstraße 16
D-32758 Detmold
D-SERIES DRI
DRIKITP 24VAC 2CO LD/PB
Germany
Fon: +49 5231 14-0
Fax: +49 5231 14-292083
Technical data
Dimensions and weights
Width
Height
Depth
15.9 mm
102.1 mm
63 mm
Width (inches)
Height (inches)
Depth (inches)
0.626 inch
4.02 inch
2.48 inch
Net weight
60.156 g
Temperatures
Humidity
35…85 % rel. humidity, no
condensation
Operating temperature, max.
55 °C
Operating temperature, min.
Storage temperature, min.
Storage temperature
-40 °C
-40 °C
-40 °C…85 °C
Storage temperature, max.
Operating temperature
85 °C
-40 °C…55 °C
Environmental Product Compliance
REACH SVHC
Lead 7439-92-1
Input
Rated control voltage
Power rating
Coil resistance
24 V AC
1.2 VA
240 Ω ± 10 %
Rated current AC
Pull-in/drop-out voltage, typ.
Status indicator
50 mA
19.2 V / 7.2 V AC
Red LED
Output
Rated switching voltage
Max. switching voltage, DC
250 V AC
250 V
Max. switching voltage, AC
Continuous current
250 V
5 A
AC switching capacity (resistive), max.
1250 VA
DC switching capacity (resistive), max.
150 W @ 24 V
Switch-on delay
≤ 15 ms
Switch-off delay
≤ 10 ms
Min. switching power
10 mA @ 12 V, 100 mA @
5 V
Max. switching frequency at rated load
0.1 Hz
Contact data
Contact type
2 CO contact with test
button (AgNi)
Mechanical service life
10 x 10
6
switching cycles
General data
Mounting rail
Mechanical switch position indicator
TS 35
Yes
Test button
Colour
yes (lockable)
Black
Insulation coordination
Rated voltage
Pollution severity
Protection degree
250 V
2
Surge voltage category
Insulating material group
Dielectric strength input – output
III
IIIb
5 kV
eff
/ 1min
IP20
Creepage and clearance distance input –
output
Impulse withstand voltage at
neighbouring contacts
Dielectric strength of neighbouring
contacts
Dielectric strength of open contact
1.5 kV
eff
/ 1 min.
1 kV
eff
/ 1 min
≥ 3 mm
4.8 kV (1.2/50 µs)
5 kV (1.2/50 µs)
Impulse withstand voltage
Creation date January 18, 2019 5:44:15 PM CET
Catalogue status 04.01.2019 / We reserve the right to make technical changes.
2
Data sheet
Weidmüller Interface GmbH & Co. KG
Klingenbergstraße 16
D-32758 Detmold
D-SERIES DRI
DRIKITP 24VAC 2CO LD/PB
Germany
Fon: +49 5231 14-0
Fax: +49 5231 14-292083
Technical data
Further details of approvals / standards
Standards
IEC 61810-1, EN
Certificate no. (cURus) relay
60664-1:2007, EN
61000-6-2:2005, EN
61000-6-4:2007 +
A1:2011
E312083
Certificate no. (cURus) base
E312083
Connection data
Wire connection method
Clamping range, rated connection
Clamping range, max.
PUSH IN with actuator
1.5 mm²
Stripping length, rated connection
Clamping range, min.
Wire connection cross section AWG,
min.
10 mm
0.14 mm²
1.5 mm²
AWG 16
1.5 mm²
AWG 26
Wire connection cross section AWG,
max.
Wire cross-section, solid, max.
Wire cross-section, solid, min.
0.14 mm²
0.14 mm²
Wire connection cross-section, finely
stranded, min.
Wire connection cross section, finely
stranded, max.
Wire connection cross-section, finely
stranded with wire-end ferrules DIN
46228/4, min.
1.5 mm²
0.14 mm²
Wire connection cross-section, finely
stranded with wire-end ferrules DIN
46228/4, max.
Conductor cross-section, flexible, AEH
(DIN 46228-1), min.
1 mm²
0.14 mm²
Conductor cross-section, flexible, AEH
(DIN 46228-1), max.
Blade size
1.5 mm²
0.4 x 2.5 mm
Classifications
ETIM 6.0
EC001437
eClass 6.2
27-37-16-01
eClass 9.1
27-37-16-01
Downloads
Approval/Certificate/Document of
Conformity
Engineering Data
Creation date January 18, 2019 5:44:15 PM CET
Catalogue status 04.01.2019 / We reserve the right to make technical changes.
3
Data sheet
Weidmüller Interface GmbH & Co. KG
Klingenbergstraße 16
D-32758 Detmold
D-SERIES DRI
DRIKITP 24VAC 2CO LD/PB
Germany
Fon: +49 5231 14-0
Fax: +49 5231 14-292083
Drawings
Wiring diagram
Graph
DC load limit curve
Resistive load
Graph
Graph
Electrical service life
AC operational voltage range
Dimensional drawing
Relay in combination with base
Creation date January 18, 2019 5:44:15 PM CET
Catalogue status 04.01.2019 / We reserve the right to make technical changes.
4
Data sheet
Weidmüller Interface GmbH & Co. KG
Klingenbergstraße 16
D-32758 Detmold
D-SERIES DRI
DRIKITP 24VAC 2CO LD/PB
Germany
Fon: +49 5231 14-0
Fax: +49 5231 14-292083
Drawings
Miscellaneous
Type codes
Creation date January 18, 2019 5:44:15 PM CET
Catalogue status 04.01.2019 / We reserve the right to make technical changes.
5