WEIDMULLER-8713910000

Part #WEIDMULLER-8713910000
Download 
WEIDMULLER-8713910000
Data sheet…  
Weidmüller Interface GmbH & Co. KG  
Klingenbergstraße 16  
D-32758 Detmold  
MCZ SERIES  
MCZ R 48…110Vdc 1CO TRAK  
Germany  
Fon: +49 5231 14-0  
Fax: +49 5231 14-292083  
The MCZ R relay couplers, with a width of only 6 mm, are  
the thinnest in their class.  
They are distinguished by the following features:  
• Tension clamp connection  
• Integrated cross-connection in input/output.  
Clampable conductor cross-section is 0.5 to 1.5 mm²  
General ordering data  
Order No.  
Type  
MCZ R 48…110Vdc 1CO TRAK  
Version  
MCZ SERIES, Relays, No. of contacts: 1, CO  
contact, AgSnO, Rated control voltage: 48 V…110  
V DC +25 % / -30 %, Continuous current: 6 A,  
Tension clamp connection  
GTIN (EAN)  
Qty.  
4032248390250  
10 pc(s).  
Creation date March 6, 2013 11:06:54 PM CET  
Catalogue status 20.12.2012 / We reserve the right to make technical changes.  
1

Data sheet…  
Weidmüller Interface GmbH & Co. KG  
Klingenbergstraße 16  
D-32758 Detmold  
MCZ SERIES  
MCZ R 48…110Vdc 1CO TRAK  
Germany  
Fon: +49 5231 14-0  
Fax: +49 5231 14-292083  
Technical data  
Ratings  
Conductor connection system  
Humidity  
95 % for 30 days, minimal  
condensation to EN  
50155  
Tension clamp connection  
right  
Open sides  
Dimensions and weights  
Width  
Depth  
6 mm  
63.2 mm  
Height  
Net weight  
91 mm  
28.3 g  
Temperatures  
Operating temperature  
Storage temperature  
-25 °C…+70 °C  
-40 °C…+85 °C  
Note: room temperature (service)  
+85 °C for 10 minutes  
Connection data  
Clamping range, rated connection  
1.5 mm²  
Clamping range, rated connection, min.
 
0.5 mm²  
Clamping range, rated connection, max.
 
2.5 mm²  
Stripping length, rated connection  
12 mm  
Input  
Rated control voltage  
Power rating  
48 V…110 V DC +25 % /  
-30 %  
Rated current DC  
< 3 mA  
Pull-in (sparkover) / drop-out voltage DC  
coil  
Max. reset time after voltage interruption10 ms  
< 300 mW  
Green LED  
> 25 V / < 6 V  
Status indicator  
Output  
Rated switching voltage  
Max. switching voltage, DC  
making current  
250 V AC  
250 V  
6 A  
Max. switching voltage, AC  
Continuous current  
Max. switching power  
250 V  
6 A  
1500 VA  
< 100 ms  
Switch-on delay  
< 4 ms  
Switch-off delay  
Min. switching power  
100 mA / 5 V, 10 V / 10  
mA, 24 V / 1 mA  
Max. switching frequency at rated load  
0.1 Hz  
Contact specifications  
No. of contacts  
Contact material  
1
Contact design  
Mechanical service life  
CO contact  
20 x 10

6

switching cycles  
AgSnO  
Insulation coordination  
Rated voltage  
Clearance and creepage distances for  
control side – load side  
300 V  
≥ 5.5 mm  
Dielectric strength for control side – load  
side  
Impulse withstand voltage  
Pollution severity  
Dielectric strength to mounting rail  
4 kV

eff

/ 1 s  
4 kV (1.2/50 µs)  
2
4 kV

eff

/ 1 min.  
Protection degree  
Surge voltage category  
IP 20  
III  
Other technical data  
Version  
Relay coupler  
Status indicator  
Green LED  
Creation date March 6, 2013 11:06:54 PM CET  
Catalogue status 20.12.2012 / We reserve the right to make technical changes.  
2

Data sheet…  
Weidmüller Interface GmbH & Co. KG  
Klingenbergstraße 16  
D-32758 Detmold  
MCZ SERIES  
MCZ R 48…110Vdc 1CO TRAK  
Germany  
Fon: +49 5231 14-0  
Fax: +49 5231 14-292083  
Technical data  
Further details of approvals / standards  
Standards  
DIN EN 50178, DIN EN  
50155  
Classifications  
ETIM 3.0  
EC001437  
eClass 6.0  
27-37-16-01  
eClass 7.0  
27-37-16-01  
Approvals  
Approvals  
Downloads  
Declaration of Conformity  
Creation date March 6, 2013 11:06:54 PM CET  
Catalogue status 20.12.2012 / We reserve the right to make technical changes.  
3

Data sheet…  
Weidmüller Interface GmbH & Co. KG  
Klingenbergstraße 16  
D-32758 Detmold  
MCZ SERIES  
MCZ R 48…110Vdc 1CO TRAK  
Germany  
Fon: +49 5231 14-0  
Fax: +49 5231 14-292083  
Drawings  
Electric symbol  
Creation date March 6, 2013 11:06:54 PM CET  
Catalogue status 20.12.2012 / We reserve the right to make technical changes.  
4