Wurth-Elektronik-810912001

Part #Wurth-Elektronik-810912001
Download 
Wurth-Elektronik-810912001
Dimensions: [mm]  
Recommended Screw Thread: [mm]  
Electrical Properties:  
Properties  
Test conditions  
Value  
Unit  
Tol.  
250 V (AC), 50/60 Hz  
250 V (DC)  
V
R  
Rated Voltage  
250  
V
max.  
M4  
I
R  
detail A  
Rated Current  
@ 40 °C/ ΔT< 60 K  
250 V (AC)/ 50 Hz  
@ 20 °C  
1.5  
0.173  
300  
20  
A
max.  
typ.  
I
Leak  
R
DC  
Leakage Current
1)  
DC Resistance  
mA  
mΩ  
max.  
Inductance  
L
10 kHz/ 0.1 mA  
1 kHz/ 1 V  
mH +50%/-30%  
5x 6,3 ±0,1  
C
X  
C
Y  
X2-Capacitance  
Y2-Capacitance  
Discharge Resistance  
0.22  
2.2  
µF  
nF  
kΩ  
10%  
20%  
10%  
63,0 ±1,0  
1 kHz/ 1 V  
R
@ 20 °C  
1000  
63,0  
Insulation Test Voltage  
L->PE  
V
T AC  
50 Hz/ 2 s/ 10 mA  
2 s/ 10 mA  
2000  
1075  
V (AC)  
V (DC)  
max.  
max.  
51,2 ±1,0  
9,0 min.  
Scale – 1:2,5  
8,0 min.  
19,8 ±1,0  
Insulation Test Voltage  
L->N  
V
T DC  
Schematic:  
1)
Leakage current is calculated according to IEC 60939-3. If the neutral line is interrupted, worst  
case leakage current could reach twice this level. There is no leakage current for DC applications.  
A
75,0 ±1,0  
General Information:  
L’  
L
Operating Temperature  
-25 up to +100 °C  
25/100/21  
40 °C  
C
Y
 
C
Y  
L

1  

L
2  
Climatic Category  
C
X  
C
X  
PE  
N
R
Rated Temperature  
| T
R  
Storage Conditions (in original  
packaging)  
< 40
 
°C ; <
 
75 %
 
RH  
N’  
Flammability Rating according to  
Moisture Sensitivity Level (MSL)  
UL94 V-0  
1
Altitude <=2000 m (above derating applies)  
Vibration resistance:
 
Do not exceed the vibration limits given by IEC60068-2-6.  
T
e
st conditions of Electrical Properties: +20 °C, 33 % RH if not specified differently  
Scale – 1:2,5  
L1 = L2 = L  
Mechanical Properties:  
Properties  
Value  
Unit Tol.  
CHECKED  
REVISION  
DATE (YYYY-MM-DD)  
GENERAL TOLERANCE  
PROJECTION  
METHOD  
Weight  
m
129  
g
typ.  
SBir  
001.001  
2023-07-17  
DIN ISO 2768-1m  
DESCRIPTION  
WE-CLFS Line Filter Single-Stage  
Advanced  
Würth Elektronik eiSos GmbH & Co. KG  
EMC & Inductive Solutions  
Max-Eyth-Str. 1  
74638 Waldenburg  
Germany  
T
e
l. +49 (0) 79 42 945 – 0  
ORDER CODE  
BUSINESS UNIT  
STATUS  
PAGE  
eiSos  
Valid  
1/6  
This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Würth Elektronik eiSos GmbH  
& Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation, transportation signal, disaster prevention, medical, public information network etc.. Würth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety must be performed on every electronic  
component which is used in electrical circuits that require high safety and reliability functions or performance.  

Certification:  
Typical Insertion Loss:  
RoHS Approval  
REACh Approval  
cURus Approval  
VDE Approval  
ENEC 10 Approval  
CE  
Compliant [2011/65/EU&2015/863]  
Conform or declared [(EC)1907/2006]  
90  
E502193 [UL 60939-3/ CSA C22.2 NO. 8-13]  
40048805 [IEC/EN 60939-2]  
80  
70  
60  
50  
40  
30  
20  
10  
0
40048805 [IEC/EN 60939-2]  
Yes [for further information please see: https://www.we-online.com/katalog/de/WE-CLFS]  
Yes [for further information please see: https://www.we-online.com/katalog/de/WE-CLFS]  
UKCA  
Mounting / Installation instructions:  
• While mounting and removing, the electronic component shall be operated in voltage-free condition pursuant to the five safety rules  
described in the standard EN 50110-1.  
•
T
o
e
stablish a low impedance path for parasitic currents the filter housing shall have a wide connection area to the ground plane. The  
ground plane shall be free of paint or other isolating materials.  
• The connection to the ground plane should be established with M4 screws. The tightening torque varies with the selected screw and  
should not exceed the limit of 5Nm.  
• The protective earth connection shall be the first to be connected while installing the filter and shall be the last to be disconnected. The  
protective earth connection must be prepared considering the leakage current.  
• The filter position is suggested to be close as possible to the application. If there are long distances between the filter and application, it  
is recommended to shield the cables, otherwise, the functionality might be affected.  
• Keep the connection to the PE as short as possible.  
•
T
o
m
inimize crosstalk do not place incoming and outgoing cables next to each other.  
• Use short cables to minimize the parasitic effects of the setup.  
-10  
0.01  
0.1  
1
10  
100  
Frequency [MHz]  
50/50
Ω
comm  
50/50
Ω
diff  
0.1/100
Ω
diff  
100/0.1
Ω
diff  
CHECKED  
REVISION  
DATE (YYYY-MM-DD)  
GENERAL TOLERANCE  
PROJECTION  
METHOD  
SBir  
001.001  
2023-07-17  
DIN ISO 2768-1m  
DESCRIPTION  
WE-CLFS Line Filter Single-Stage  
Advanced  
Würth Elektronik eiSos GmbH & Co. KG  
EMC & Inductive Solutions  
Max-Eyth-Str. 1  
74638 Waldenburg  
Germany  
T
e
l. +49 (0) 79 42 945 – 0  
ORDER CODE  
BUSINESS UNIT  
STATUS  
PAGE  
eiSos  
Valid  
2/6  
This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Würth Elektronik eiSos GmbH  
& Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation, transportation signal, disaster prevention, medical, public information network etc.. Würth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety must be performed on every electronic  
component which is used in electrical circuits that require high safety and reliability functions or performance.  

Test Setup:  
Derating Curve:  
120%  
100%  
80%  
60%  
40%  
20%  
According to CISPR 17  
1´ (GND)  
Port 1  
2´ (GND)  
Port 2  
L
L´  
1
2
DUT  
3
Port 3  
4
N
N´  
Port 4  
4´ (GND)  
3´ (GND)  
Network Analyzer: Keysight E5080A or equivalent  
0%  
0
20  
40  
60  
80  
100  
Temperature [°C]  
CHECKED  
REVISION  
DATE (YYYY-MM-DD)  
GENERAL TOLERANCE  
PROJECTION  
METHOD  
SBir  
001.001  
2023-07-17  
DIN ISO 2768-1m  
DESCRIPTION  
WE-CLFS Line Filter Single-Stage  
Advanced  
Würth Elektronik eiSos GmbH & Co. KG  
EMC & Inductive Solutions  
Max-Eyth-Str. 1  
74638 Waldenburg  
Germany  
T
e
l. +49 (0) 79 42 945 – 0  
ORDER CODE  
BUSINESS UNIT  
STATUS  
PAGE  
eiSos  
Valid  
3/6  
This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Würth Elektronik eiSos GmbH  
& Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation, transportation signal, disaster prevention, medical, public information network etc.. Würth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety must be performed on every electronic  
component which is used in electrical circuits that require high safety and reliability functions or performance.  

Packaging Specification – Tray and Carton: [mm]  
Cover  
EPE Foam  
Grid  
Box  
EPE Foam  
H
L2  
BOX  
BOX  
L1  
BOX  
L
BOX  
No. of  
box  
pcs.  
7
No. of  
Packaging  
L
C
(mm)  
W
C
(mm)  
H
C
(mm)  
Material  
EPE foam  
Unit  
pcs.  
56  
No. of  
Packaging  
Unit  
pcs.  
8
typ.  
320,00  
typ.  
240,00  
typ.  
310,00  
pcs.  
2
L
BOX
(mm)  
L1
BOX
(mm)  
L2
BOX
(mm)  
W
BOX
(mm)  
W1
BOX
(mm)  
H
BOX
(mm)  
Material  
EPE Foam  
Paper  
typ.  
310,00  
typ.  
174  
typ.  
58  
typ.  
230  
typ.  
81  
typ.  
29  
pcs.  
2
Paper  
CHECKED  
REVISION  
DATE (YYYY-MM-DD)  
GENERAL TOLERANCE  
PROJECTION  
METHOD  
SBir  
001.001  
2023-07-17  
DIN ISO 2768-1m  
DESCRIPTION  
WE-CLFS Line Filter Single-Stage  
Advanced  
Würth Elektronik eiSos GmbH & Co. KG  
EMC & Inductive Solutions  
Max-Eyth-Str. 1  
74638 Waldenburg  
Germany  
T
e
l. +49 (0) 79 42 945 – 0  
ORDER CODE  
BUSINESS UNIT  
STATUS  
PAGE  
eiSos  
Valid  
4/6  
This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Würth Elektronik eiSos GmbH  
& Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation, transportation signal, disaster prevention, medical, public information network etc.. Würth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety must be performed on every electronic  
component which is used in electrical circuits that require high safety and reliability functions or performance.  

Packaging:  
Cautions and Warnings:  
•
The packaging specifications apply only to purchase orders comprising whole packaging units. If the ordered quantity exceeds or is  
lower than the specified packaging unit, packaging in accordance with the packaging specifications cannot be ensured.  
The following conditions apply to all goods within the product series of
 
WE-CLFS of  
Würth Elektronik eiSos GmbH & Co. KG:  
Handling:  
General:  
•
•
Violation of the technical product specifications such as exceeding the nominal rated current will void the warranty.  
Only qualified personnel should work with the electronic component including, but not limited to, work such as planning, assembly,  
installation, operation, repair and maintenance considering the corresponding documentation.  
The filter includes components storing an electric charge and dangerous voltage may remain at the filter terminals even after the power  
source has been disconnected even after five minutes.  
In case temporary voltage is applied to the unassembled filter, the filter shall be discharged after the power source has been  
disconnected.  
Avoid any overload or conditions that are not specified in the datasheet.  
Do not exceed the specified temperature limits.  
To
m
aintain regular operation, the filters shall be protected within the application against inadmissible exceedance of the rated current.  
The filter leakage current specified in the data sheet merely serves as a user information. For security reasons, the maximum leakage  
current of the entire electrical application has to be limited. The permissible limits for your application must be acquired from the relative  
and applicable regulations, provisions and standards.  
•
•
This electronic component was designed and manufactured for use in general electronic equipment.  
Würth Elektronik must be asked for written approval (following the PPAP procedure) before incorporating the components into any  
equipment in fields such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control,  
ship control), transportation signal, disaster prevention, medical, public information network, etc. where higher safety and reliability are  
especially required and/or if there is the possibility of direct damage or human injury.  
•
•
•
•
Electronic components that will be used in safety-critical or high-reliability applications, should be pre-evaluated by the customer.  
The component is designed and manufactured to be used within the datasheet specified values. If the usage and operation conditions  
specified in the datasheet are not met, the wire insulation may be damaged or dissolved.  
•
•
•
•
•
•
Do not drop or impact the components, the component may be damaged.  
Würth Elektronik products are qualified according to international standards, which are listed in each product reliability report. Würth  
Elektronik does not guarantee any customer qualified product characteristics beyond Würth Elektroniks’ specifications, for its validity and  
sustainability over time.  
•
•
•
The current derating must be observed. Disregarding the current derating might result in overheating and in a fire hazard as a  
consequence thereof.  
Due to the heavy weight of the electronic component, strong forces and high accelerations might have the effect to damage the  
electrical connection and will void the warranty.  
The temperature rise of the component must be taken into consideration. The operating temperature is comprised of ambient  
temperature and temperature rise of the component.The operating temperature of the component shall not exceed the maximum  
temperature specified.  
•
The customer is responsible for the functionality of their own products. All technical specifications for standard products also apply to  
customer specific products.  
Product specific:  
Cleaning and Washing:  
•
Washing agents used during the production to clean the customer application might damage or change the characteristics of the  
component. Washing agent may have a negative effect on the long-term functionality of the product.  
These cautions and warnings comply with the state of the scientific and technical knowledge and are believed to be accurate and reliable.  
However, no responsibility is assumed for inaccuracies or incompleteness.  
Storage Conditions:  
•
A storage of Würth Electronik products for longer than 12 months is not recommended. Within other effects, the terminals may suffer  
degradation, resulting in bad solderability. Therefore, all products shall be used within the period of 12 months based on the day of  
shipment.  
•
•
•
Do not expose the components to direct sunlight.  
The storage conditions in the original packaging are defined according to DIN EN 61760-2.  
The storage conditions stated in the original packaging apply to the storage time and not to the transportation time of the components.  
CHECKED  
REVISION  
DATE (YYYY-MM-DD)  
GENERAL TOLERANCE  
PROJECTION  
METHOD  
SBir  
001.001  
2023-07-17  
DIN ISO 2768-1m  
DESCRIPTION  
WE-CLFS Line Filter Single-Stage  
Advanced  
Würth Elektronik eiSos GmbH & Co. KG  
EMC & Inductive Solutions  
Max-Eyth-Str. 1  
74638 Waldenburg  
Germany  
T
e
l. +49 (0) 79 42 945 – 0  
ORDER CODE  
BUSINESS UNIT  
STATUS  
PAGE  
eiSos  
Valid  
5/6  
This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Würth Elektronik eiSos GmbH  
& Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation, transportation signal, disaster prevention, medical, public information network etc.. Würth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety must be performed on every electronic  
component which is used in electrical circuits that require high safety and reliability functions or performance.  

6. Product Life Cycle  
Important Notes  
Due to technical progress and economical evaluation we also reserve the right to discontinue production and delivery of products. As a  
standard reporting procedure of the Product Termination Notification (PTN) according to the JEDEC-Standard we will inform at an early stage  
about inevitable product discontinuance. According to this we cannot guarantee that all products within our product range will always be  
available. Therefore it needs to be verified with the field sales engineer or the internal sales person in charge about the current product  
availability expectancy before or when the product for application design-in disposal is considered. The approach named above does not  
apply in the case of individual agreements deviating from the foregoing for customer-specific products.  
The following conditions apply to all goods within the product range of Würth Elektronik  
eiSos GmbH & Co. KG:  
1. General Customer Responsibility  
Some goods within the product range of Würth Elektronik eiSos GmbH & Co. KG contain statements regarding general suitability for certain  
application areas. These statements about suitability are based on our knowledge and experience of typical requirements concerning the  
areas, serve as general guidance and cannot be estimated as binding statements about the suitability for a customer application. The  
responsibility for the applicability and use in a particular customer design is always solely within the authority of the customer. Due to this  
fact it is up to the customer to evaluate, where appropriate to investigate and decide whether the device with the specific product  
characteristics described in the product specification is valid and suitable for the respective customer application or not.  
7. Property Rights  
All the rights for contractual products produced by Würth Elektronik eiSos GmbH & Co. KG on the basis of ideas, development contracts as  
well as models or templates that are subject to copyright, patent or commercial protection supplied to the customer will remain with Würth  
Elektronik eiSos GmbH & Co. KG. Würth Elektronik eiSos GmbH & Co. KG does not warrant or represent that any license, either expressed or  
implied, is granted under any patent right, copyright, mask work right, or other intellectual property right relating to any combination,  
application, or process in which Würth Elektronik eiSos GmbH & Co. KG components or services are used.  
2. Customer Responsibility related to Specific, in particular Safety-Relevant Applications  
8. General Terms and Conditions  
It has to be clearly pointed out that the possibility of a malfunction of electronic components or failure before the end of the usual lifetime  
cannot be completely eliminated in the current state of the art, even if the products are operated within the range of the specifications.  
In certain customer applications requiring a very high level of safety and especially in customer applications in which the malfunction or  
failure of an electronic component could endanger human life or health it must be ensured by most advanced technological aid of suitable  
design of the customer application that no injury or damage is caused to third parties in the event of malfunction or failure of an electronic  
component. Therefore, customer is cautioned to verify that data sheets are current before placing orders. The current data sheets can be  
Unless otherwise agreed in individual contracts, all orders are subject to the current version of the “General
T
e
rms and Conditions of Würth  
3. Best Care and Attention  
Any product-specific notes, cautions and warnings must be strictly observed. Any disregard will result in the loss of warranty.  
4. Customer Support for Product Specifications  
Some products within the product range may contain substances which are subject to restrictions in certain jurisdictions in order to serve  
specific technical requirements. Necessary information is available on request. In this case the field sales engineer or the internal sales  
person in charge should be contacted who will be happy to support in this matter.  
5. Product R&D  
Due to constant product improvement product specifications may change from time to time. As a standard reporting procedure of the  
Product Change Notification (PCN) according to the JEDEC-Standard inform about minor and major changes. In case of further queries  
regarding the PCN, the field sales engineer or the internal sales person in charge should be contacted. The basic responsibility of the  
customer as per Section 1 and 2 remains unaffected.  
CHECKED  
REVISION  
DATE (YYYY-MM-DD)  
GENERAL TOLERANCE  
PROJECTION  
METHOD  
SBir  
001.001  
2023-07-17  
DIN ISO 2768-1m  
DESCRIPTION  
WE-CLFS Line Filter Single-Stage  
Advanced  
Würth Elektronik eiSos GmbH & Co. KG  
EMC & Inductive Solutions  
Max-Eyth-Str. 1  
74638 Waldenburg  
Germany  
T
e
l. +49 (0) 79 42 945 – 0  
ORDER CODE  
BUSINESS UNIT  
STATUS  
PAGE  
eiSos  
Valid  
6/6  
This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Würth Elektronik eiSos GmbH  
& Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation, transportation signal, disaster prevention, medical, public information network etc.. Würth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety must be performed on every electronic  
component which is used in electrical circuits that require high safety and reliability functions or performance.