Zhejiang-HKE-HRS4H-S-DC24V-C

Part #Zhejiang-HKE-HRS4H-S-DC24V-C
Download 
Zhejiang-HKE-HRS4H-S-DC24V-C
Page 1
 
/ 3  
浙江汇港电器有限公司  
说 明 书  
型号
: HRS4H-S-DC24V
继电器(
C
型)  
1.
线圈参数  
1.1
额定电压  
1.2
线圈电阻  
1.3
额定电流  
1.4
吸合电压  
1.5
释放电压  
1.6
最大线圈电压  
1.7
额定功率  
24VDC  
1600
Ω±
10% at 23
℃  
15mA
±
10% at 23
℃  
16.8VDC Max at 23
℃  
2.4VDC Min at 23
℃  
31.2VDC(130%
额定电压
)  
360mW  
2
.
触点参数  
2.1
触点形式  
2.2
触点材料  
2.3
触点负载  
1 Form C  
Ag Alloy  
阻性:
NO
:
10A 250VAC/24VDC  
NC
:
6A 250VAC/24VDC  
30VDC/250VAC  
2.4
最大切换电压  
2.5
最大切换电流  
2.6
最大切换功率  
2.7
最小切换电流电压  
2.8
接触电阻
(
首次
)  
2.9
寿命  
15A  
2,500VA , 240W  
100mA 5VDC  
Max.100m
Ω
at 6VDC 1A  
(1)
电气寿命  
额定负载
下
100,000
次  
(360
次
/
小时
)  
(2)
机械寿命  
空载
下
10,000,000
次  
(18,000
次
/
小时
)  
3
.
性能  
3.1
绝缘电阻  
3.2
介质耐压
(
漏电流
: 1mA)  
(1)
触点间  
(2)
线圈与触点间  
3.3
吸合时间  
3.4
释放时间  
3.5
环境温度  
3.6
贮存温度  
Min.1,000M
Ω
at 500VDC  
750VAC, 1 min , 50/60Hz  
1,500VAC, 1 min , 50/60Hz  
Max. 10ms.  
Max. 5ms.  
-40 to +85
℃
 
-40 to +85
℃  

Page 2
 
/ 3  
浙江汇港电器有限公司  
3.7
温升  
3.7.1
线圈  
电阻法,触点施加额定电流
10A
,
110%
额定电压激  
励线圈,温升不超过
55k
。  
3.8
冲击  
3.8.1
强度  
1,000m/s

2

, 6ms, 3 shock (X,
Y
, Z
每个方向
)  
继电器结构无损坏。  
3.8.2
稳定性  
100m/s

2

, 11ms, 3 shock (X,
Y
, Z
每个方向
)  
继电器外观、性能无异常。  
3.9
振动  
3.9.1
强度  
双振
幅
1.5mm,
频
率
10
~
55Hz, 2hs
。  
继电器结构无损坏。  
3.9.2
稳定性  
3.10
端子强度  
3.11
寒冷  
双振
幅
1.5mm,
频
率
10
~
55Hz, 5min
。  
继电器外观、性能无异常  
1kg
力推拉继电器引出
端
10
秒。  
-40
±
2
℃
, 2
小时  
继电器结构及性能无异常。  
3.12
干热  
85
±
2
℃
, 16
小时  
继电器结构及性能无异常。  
3.13
湿热  
40
±
2
℃
, 90-95%, 48
小时  
继电器结构及性能无异常。  
绝缘电阻最
小
1,000M
Ω  
3.14
可焊性  
3.15
耐焊性  
焊锡应在浸渍表面完成。  
焊锡温
度
260
℃,时
间
5
秒  
当继电器引出端沉浸
在
260
℃(时
间
10
秒)  
或
350
℃( 时
间
3
秒)的锡温中继电器结构  
及性能无异常。  

Page 3
 
/ 3  
浙江汇港电器有限公司  
4
命名  
HRS4  
a
H –
 
S – DC24V  
b
c
a
:继电器系列型号  
b
:额定功率:  
H
:
360mW  
c
:线圈电压
DC24V  
5
印字  
具体见附
件
Y
–
HRS4-N13-02  
黑色  
5.
1
外壳颜色  
5.
2
印字位置  
5.3
印字类型  
外壳正上方  
激光印字  
6
外形尺寸  
7
认证  
请见附件
HKE4.523.022  
UL NO.E164730  
TUV NO.R50116136  
CSA NO.1063016
(
LR 109368
)  
CQC08002027614  

2 0
 
– 3
 
1 N
 
– 4 S R H
 
– Y  
H=1.4  
1.6 0.1  
H=2.3  
2
HRS4H-S-DC12V  
H=1.1  
HRS4H-S-DC12V  
10A 250V  
10A 120VAC  
~
H=1.1
50Hz COSO1
 
10A 24VDC  
10A 250V  
10A 120VAC  
10A 24VDC  
~
50Hz COSO1  
A
R.C.G  
5K3K  
R.C.G  
A
5K3K  
H=1.1  
H=1.1  
1
3
18.7 0.1  
HRS4H-S-DC12V  
HRS4H-S-DC12V  
6A 250V  
10A 120VAC  
10A 24VDC  
~
6A 250V  
10A 120VAC  
10A 24VDC  
~
50Hz COSO1  
50Hz COSO1  
R.C.G  
B
5K3K  
R.C.G  
B
5K3K  
HRS4H-S-DC12V  
HRS4H-S-DC12V  
NO:10A 250V  
NC: 6A
250V  
~
10A 120VAC  
10A 24VDC  
NO:10A 250V  
NC: 6A
250V  
~
10A 120VAC  
10A 24VDC  
~
~
R.C.G  
C
5K3K  
R.C.G  
C
C
5K3K  
1 1
:
1  
2 1.5:1  
1
R.C.G  
AgCdO  
2
DC12V  
S
H
HRS4  
DC3V DC5V DC6V  
DC9V DC12V DC24V  
DC48V  
Nil 0.45W  
H 0.36W  
3
5
K
3
K
A:JAN E:MAY I:SEP  
B:FEB F:JUN J:OCT  
C:MAR G:JUL
 
K:NOV  
D:APR H:AUG
 
L:DEC  
1:FIRST WEEK  
2:SECOND WEEK
 
MAKER  
3:THIRD WEEK  
4:FOURTH WEEK  
1.  
2.  
0.2,  
mm  
Y
–
HRS4-N13-02  
HRS4  
(
)
HRS4 Marking  
A4  

2 2 0
 
. 3
 
2 5
 
. 4
 
E K H  
1.75 0.2  
5-O1.3  
19.0max  
15.5max  
2.0  
3.4 0.2  
12.2  
0.9 0.1  
0.5 0.1  
0.5 0.1  
0.9 0.1  
4.0 0.3  
0.4 0.1  
2.0 0.2  
12.0 0.3  
12.2 0.3  
HRS4  
HRS4-C  
HRS4-C Relay  
Outline  
HKE4.523.022  
A4  

NRNT2.E164730 – Switches, Industrial Control – Component  
页码,1/2  
NRNT2.E164730  
Switches, Industrial Control – Component  
Page Bottom  
Switches, Industrial Control – Component  
See General Information for Switches, Industrial Control – Component  
ZHEJIANG HKE RELAY CO LTD  
28 JIA CUN INDUSTRY AREA  
E164730  
NINGBO, ZHEJIANG 315135 CHINA  
Relays
, Model(s) AC, followed by 3, followed by S, followed by DC, followed by 5V, 6V, 9V, 12V, 18V or 24V, followed by A  
Relays
, Model(s) CMP6-S or F6-S, followed by DC5V, 6V, 9V, 12V, or 24V, may be followed by P  
Relays
, Model(s) CMP7 or CMP8, followed by Nil or S, followed by DC5V, DC6V, DC24V, DC9V, DC12V, DC24V, DC48V,  
followed by A or C  
Relays
, Model(s) CMP8(AT)-S followed by DC5V, DC6V, DC9V, DC12V, DC24V or DC48V, followed by A  
Relays
, Model(s) HCP, followed by 1, 2 or 3, followed by blank or S, followed by DC, followed by 5V, 6V, 9V, 12V, 18V, 24V,  
36V, 48V, followed by A or C, HRA, may be followed by H, may be followed by S, HRB1-S, followed by DC3V, DC5V, DC6V,  
DC9V, DC12V or DC24V, HRM, may be followed by 1 or 2, may be followed by H, may be followed by S  
Relays
, Model(s) HRM, may be followed by 3, may be followed by H or L, may be followed by S, may be followed by DC3-  
DC48 , may be followed by T.  
Relays
, Model(s) HRM4, may be followed by H, may be followed by S, followed by DC3-DC24 incl  
Relays
, Model(s) HRM4, may be followed by H, may be followed by S, may be followed by DC3 – DC48, followed by SP, HRMF,  
followed by DC3V, DC5V, DC6V, DC9V, DC12V, DC18V, DC24V or DC48V  
Relays
, Model(s) HRS, may be followed by 3 or 4, may be followed by H, may be followed by A, may be followed by S, followed  
by DC3-D48 incl  
Relays
, Model(s) HRS1, may be followed by K, may be followed by B or H, may be followed by 3, may be followed by S,  
followed by DC, followed by XX, where XX is coil voltage, HRS2, may be followed by B or H, may be followed by S  
Relays
, Model(s) HRS2H, followed by S, followed by 3 VDC through 48 VDC, may be followed B, N or T  
Relays
, Model(s) HRS3, may be followed by N, may be followed by H, followed by S, followed by DC3V, DC5V, DC6V, DC9V,  
DC12V, or DC24V, may be followed by A or C  
Relays
, Model(s) HRS3-S, followed by DC3V, DC5V, DC6V, DC9V, DC12V or DC24V, followed by A or C  
Relays
, Model(s) HRS3T, may be followed by N, may be followed by H, followed by S, followed by DC, followed by 3V, 5V, 6V,  
9V, 12V or 24V, followed by A or C  
Relays
, Model(s) HRS4, may be followed by T, may be followed by F, may be followed by H, followed by S, followed by DC,  
followed by 3V, through 60V may be followed by a A  
Relays
, Model(s) HRS4E, followed by by Blank or H; followed by Blank or S; followed by DC3V, DC5V, DC6V, DC9V, DC12V,  
DC18V, DC24V or DC48V; followed by X or G  
Relays
, Model(s) L7, may be followed by S, followed by DC6V, DC12V, DC24V, DC48V, DC100V, DC110V, AC6V, AC12V,  
AC24V, AC48V, AC100V, AC120V, AC220V, AC240V, followed by 1A or 2A, followed by 2P or 2Q  

NRNT2.E164730 – Switches, Industrial Control – Component  
页码,2/2  
Relays
, Model(s) V6, may be followed by S, followed by DC3V, DC5V, DC6V, DC9V, DC12V, DC18V, DC24V or DC48V  
Relays, open type
, Model(s) AC5, may be followed by N, may be followed by S, followed by DC, followed by 5V, 6V, 9V, 12V,  
18V or 24V  
Relays, open type
, Model(s) F5, may be followed by H, followed by DC, followed by 3V, 5V, 6V, 9V, 12V, 18V, 24V or 48V,  
followed by P1,P2 or P3  
Relays, open type
, Model(s) HCP4, may be followed by S, followed by DC, followed by 5V, 6V, 9V, 12V, 18V, 24V, 36V, or  
48V, followed by A or C.  
Relays, open type, for use in industrial application
, Model(s) LH-DC12V-Q-2C  
Marking: Company name or tradename “E164730” or trademark  
Last Updated on 2010-01-10  
,
and model designation.  
Page Top  
Questions?  
Notice of Disclaimer  
Copyright ?2010 Underwriters Laboratories Inc.®  
The appearance of a company’s name or product in this database does not in itself assure that products so identified have been  
manufactured under UL’s Follow-Up Service. Only those products bearing the UL Mark should be considered to be Listed and  
covered under UL’s Follow-Up Service. Always look for the Mark on the product.  
UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1.  
The Guide Information, Designs and/or Listings (files) must be presented in their entirety and in a non-misleading manner,  
without any manipulation of the data (or drawings). 2. The statement “Reprinted from the Online Certifications Directory with  
permission from Underwriters Laboratories Inc.” must appear adjacent to the extracted material. In addition, the reprinted  
material must include a copyright notice in the following format: “Copyright © 2010 Underwriters Laboratories Inc.®”